| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-AOC 1C SELIMPUR ROAD KOLKATA 700031 | KOLKATA | WEST BENGAL | 700031 | ₹2.4 L | L1 | Accepted-AOC Accept |
| 2 | L2₹2.6 L+₹20,803 (8.53%)Rejected-Finance 90 E BECHARAM CHATTERJEE ROAD KOLKATA 700034 | KOLKATA | KOLKATA | WEST BENGAL | 700034 | ₹2.6 L+₹20,803 (8.53%) | L2 | Rejected-Finance 2nd Lowest |
| 3 | L3₹2.7 L+₹26,833 (11.0%)Rejected-Finance MOSAT HARIPUR RD VILL P O HARIPUR DIST HOOGHLY PIN 712701 | HARIPUR | HOOGHLY | WEST BENGAL | 712701 | ₹2.7 L+₹26,833 (11.0%) | L3 | Rejected-Finance 3rd Lowest |
| Sl No | Description | Qty | Unit | SIMPSON AND FERRIS PVT LTD L2 | GHANASHYAM ELECTRIC STORES L3 | TECHNO ENGINEERS AND SERVICES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply & delivery of Hi- wall Split Air conditioner having following specification:
Minimum Cooling Capacity(Kcal/Hr)- 4500 K.Cal/hr Or 5000W
ISEER Rating - 3.8-4.39 /2022-2024 as per BEE/BIS
IS Compliance- IS 1391
Refrigerant- R410A/R32
Compressor - Rotary/ Scroll
Evaporator & Condenser Coil: Copper
LCD Remote and All other accessories
operating outdoor Temperature - 50°C
Power supply - 240 V,50Hz(+ Tolerrance as per applicable standard)
Make:- O-General/ Mitsubishi Electric/ Daikin/ Hitachi | 4 | Nos. | 47,500 ₹1,90,000 | 48,225 ₹1,92,900 | 45,999 ₹1,83,996 Lowest |
| 2.00 | Installation Testing & commissioning of the above Said Split Acs incl. Supply & fixing required Angle iron structure on wall for placing outdoor unit and mending Good the damages as per direction of EIC | 4 | Job | 2,500 ₹10,000 Lowest | 3,000 ₹12,000 | 2,599 ₹10,396 |
| 3.00 | S & Installation of Extra Add-on Items- HVAC grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle, screws, insulation tape, fasner etc for above AC machines as per direction of EIC. | 32 | Mtr | 1,100 ₹35,200 | 1,110 ₹35,520 | 979 ₹31,328 Lowest |
| 4.00 | Supply & Laying 1.1KV grade 3 core 2.5 sqmm flexible copper cable with screw, saddle drill machine nut bolt etc all necy. items needed for connection.(from starter to AC outdoor connection)(Make: Havells/KEI/Polycab/Fenolex as per approved by EIC) | 32 | Mtr | 250 ₹8,000 | 275 ₹8,800 | 229 ₹7,328 Lowest |
| 5.00 | Supply & Laying 20mm hard PVC pipe(heavy type) for water discharge(Make: supreme ) | 40 | Mtr | 80 ₹3,200 | 85 ₹3,400 | 69 ₹2,760 Lowest |
| 6.00 | Dismentling the existing Acs from existing location Part by part outdoor as well as indoor and shifing this machins to the departmental store as per direction of EIC | 4 | Each | 1,500 ₹6,000 | 1,500 ₹6,000 | 999 ₹3,996 Lowest |
| 7.00Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved RR/ havells/ Polycab) in 20/25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required | ||||||
| 7.10 | 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC for AC | 15 | Mtr | 208 ₹3,120 | 160 ₹2,400 Lowest | 199 ₹2,985 |
| 8.00Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. | ||||||
| 8.10 | 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC for AC | 1 | Set | 30 ₹30 | 10 ₹10 Lowest | 49 ₹49 |
Tender Value
Refer Docs
EMD Value
₹4,880
Closing Date
29 Nov 2025, 2:00 pmClosed
AEWBESDPWD
Block I First Floor Writers Buildings Kolkata 700001
Replacement of more than 10 years old split AC machines and SITC new Split Type Air-conditioned Machines at PA room and adjacent room of HMIC correctional services, 1st floor, Jessop Building under Writers Building Electrical Sub-Division, PWD.
2025_WBPWD_926349_1
WBPWD/AE/WBESD/eNIQ-22 of 2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
14 days
Jessop Building
Please refer Tender documents.
6 documents required · 6 mandatory
₹4,880
15 Sept 2026
16 Oct 2025
1 Dec 2025
16 Oct 2025
29 Nov 2025
21 Oct 2025
Amount
Supply & delivery of Hi- wall Split Air conditioner having following specification: Minimum Cooling Capacity(Kcal/Hr)- 4500 K.Cal/hr Or 5000W ISEER Rating - 3.8-4.39 /2022-2024 as per BEE/BIS IS Compliance- IS 1391 Refrigerant- R410A/R32 Compressor - Rotary/ Scroll Evaporator & Condenser Coil: Copper LCD Remote and All other accessories operating outdoor Temperature - 50°C Power supply - 240 V,50Hz(+ Tolerrance as per applicable standard) Make:- O-General/ Mitsubishi Electric/ Daikin/ Hitachi
Installation Testing & commissioning of the above Said Split Acs incl. Supply & fixing required Angle iron structure on wall for placing outdoor unit and mending Good the damages as per direction of EIC
S & Installation of Extra Add-on Items- HVAC grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle, screws, insulation tape, fasner etc for above AC machines as per direction of EIC.
Supply & Laying 1.1KV grade 3 core 2.5 sqmm flexible copper cable with screw, saddle drill machine nut bolt etc all necy. items needed for connection.(from starter to AC outdoor connection)(Make: Havells/KEI/Polycab/Fenolex as per approved by EIC)
Supply & Laying 20mm hard PVC pipe(heavy type) for water discharge(Make: supreme )
Dismentling the existing Acs from existing location Part by part outdoor as well as indoor and shifing this machins to the departmental store as per direction of EIC
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved RR/ havells/ Polycab) in 20/25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC for AC
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC for AC
S & F 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 25A Plug top with indicator & making necy. connections (Make:Havells/anchor/Legrand)
S & F 240V, 21A Digital OLP Aircondition Starter having under voltage and overvoltage protection With 2 module GI modular type switch board with top cover plate flushed in wall & making necy. Connections with PVC cu wire & earth continuity wire .Make(Electron)
SIMPSON AND FERRIS PVT LTD (BID ID -7465992)
GHANASHYAM ELECTRIC STORES (BID ID -7450560)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .