| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.4 LAccepted-AOC | ₹41.4 L Quoted ₹42.6 L | L1 | Accepted-AOC Accepted and Reasonable |
| 2 | L2₹44.5 LRejected-Finance 011 NAGAREWADI 612 NAGAREWADI POST PADALI TALUKA SHIRUR KASAR DISTRICT BEED 413249 BEED MAHARASHTRA 413249 UDYAM MH 05 0079863 | BEED | MAHARASHTRA | 413249 | ₹44.5 L | L2 | Rejected-Finance Being L2 |
| 3 | L3₹44.9 LRejected-Finance PULGAON | ₹44.9 L | L3 | Rejected-Finance Being L3 |
| 4 | L4₹45.3 LRejected-Finance | ₹45.3 L | L4 | Rejected-Finance Being L4 |
| 5 | L5₹48.1 LRejected-Finance 58 CHANDRALOK BUILDING MAYO HOSPITAL ROAD NAGPUR 440 018 | NAGPUR | MAHARASHTRA | 440018 | ₹48.1 L | L5 | Rejected-Finance Being L5 |
| Sl No | Description | Qty | Unit | RAJ ENTERPRISES L4 | MAHARASHTRA ENTERPRISES L2 | M/S Maa Durga Constructions,Pulgaon L3 | M/s MM TRADERS L8 | SHREE SIDDHIVINAYAK TRADERS L10 | Paragon Electrotechnics L5 | SHRI RANI SATI TRADERS L9 | SHUBHAM SALES L6 | M/S JAI BHAWANI CONSTRUCTIONS L7 | Chinmaya Enteprises L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully conceled/ casing caping point wiring copper / aluminium (light / fan / scoket) complete (with fittings such as switches ceiling rose, pendents, regulators sockets etc) and making good disturbed surface with exisitng specification all as specified and directed by Engr-in-Charge. | 1,949 | Per Point | 47 ₹91,603 | 45 ₹87,705 | 51 ₹99,399 | 53 ₹1.0 L | 54 ₹1.1 L | 53 ₹1.0 L | 52 ₹1.0 L | 51 ₹99,399 | 55 ₹1.1 L | 50 ₹97,450 |
| 2.00 | M&L for point wiring complete with 1.5 sqmm single core unsheathed PVC insulated FRLSH cable 1100 V grade multistranded copper conductor in different colour code ISI marked drawn through and including non metallic rigid PVC conduit of suitable size with accessories ISI marked concealed in wall / ceilling incuding PVC insulated copper cable for earth continuity conductor of same type and size and connected to earth dolly including provision of sunken cast iron / pressed steel terminal box of suitable size with for Modular Box,cover plate mounting switches / sockets and regulators etc complete all as specified and directed by Engr -in - Charge for theOne light point controlled by one switch one way
Note :- Cutting chases for laying of conduit and sunken boxes and making good to walls, floor etc will be included in the above quoted rates. | 60 | Per Point | 905 ₹54,300 | 900 ₹54,000 | 901 ₹54,060 | 953 ₹57,180 | 940 ₹56,400 | 915 ₹54,900 | 943 ₹56,580 | 935 ₹56,100 | 922 ₹55,320 | 750 ₹45,000 |
| 3.00 | All as per item No 2 above…. But for One bell point controlled by one switch one way. | 5 | Per Point | 905 ₹4,525 | 900 ₹4,500 | 901 ₹4,505 | 953 ₹4,765 | 940 ₹4,700 | 915 ₹4,575 | 943 ₹4,715 | 935 ₹4,675 | 922 ₹4,610 | 750 ₹3,750 |
| 4.00 | All as per item No 2 above…. But for One ceiling fan / exhaust fan / wall mounting fan point controlled by one switch one way | 12 | Per Point | 905 ₹10,860 | 900 ₹10,800 | 901 ₹10,812 | 953 ₹11,436 | 940 ₹11,280 | 915 ₹10,980 | 943 ₹11,316 | 930 ₹11,160 | 922 ₹11,064 | 700 ₹8,400 |
| 5.00 | All as per item No 2 above…. But for One socket outlet three pin 5/6 Amps controlled by one switch on the same board. | 40 | Per Point | 305 ₹12,200 | 300 ₹12,000 | 301 ₹12,040 | 353 ₹14,120 | 320 ₹12,800 | 311 ₹12,440 | 343 ₹13,720 | 300 ₹12,000 | 315 ₹12,600 | 250 ₹10,000 |
| 6.00 | All as per item No 2 above…. But for One switch socket outlet three pin 5 /6 Amps controlled by one switch on independent board. | 40 | Per Point | 905 ₹36,200 | 900 ₹36,000 | 901 ₹36,040 | 953 ₹38,120 | 940 ₹37,600 | 915 ₹36,600 | 943 ₹37,720 | 935 ₹37,400 | 922 ₹36,880 | 750 ₹30,000 |
| 7.00 | M&L point wiring complete with 1.5sqmm single core unsheathed PVC insulated FRLSH cable 1100 V grade multistranded copper conductor of different code of ISI marked drawn through and incl PVC casing caping of suitable size with accessories ISI marked incl PVC insulated copper cable for earth of same type and sized connected to earth dolly including metal box and provision of Modular Box,cover plate of suitable size for mounting switches / sockets and fan regulators etc complete all as specified and directed for the One light point controlled by one switch one way | 260 | Per Point | 905 ₹2.4 L | 900 ₹2.3 L | 851 ₹2.2 L | 953 ₹2.5 L | 940 ₹2.4 L | 915 ₹2.4 L | 943 ₹2.5 L | 935 ₹2.4 L | 922 ₹2.4 L | 725 ₹1.9 L |
| 8.00 | All as per item No 7 above…. But for One bell point controlled by one switch one way. | 13 | Per Point | 905 ₹11,765 | 900 ₹11,700 | 851 ₹11,063 | 953 ₹12,389 | 940 ₹12,220 | 915 ₹11,895 | 943 ₹12,259 | 940 ₹12,220 | 922 ₹11,986 | 725 ₹9,425 |
| 9.00 | All as per item No 7 above…. But for One ceiling fan / exhaust fan / wall mounting fan point controlled by one switch one way | 39 | Per Point | 905 ₹35,295 | 900 ₹35,100 | 851 ₹33,189 | 953 ₹37,167 | 940 ₹36,660 | 915 ₹35,685 | 943 ₹36,777 | 940 ₹36,660 | 922 ₹35,958 | 725 ₹28,275 |
| 10.00 | All as per item No 7 above…. But for One socket outlet three pin 5/6 Amps controlled by one switch on the same board. | 65 | Per Point | 305 ₹19,825 | 300 ₹19,500 | 301 ₹19,565 | 353 ₹22,945 | 328 ₹21,320 | 315 ₹20,475 | 343 ₹22,295 | 350 ₹22,750 | 315 ₹20,475 | 225 ₹14,625 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
30 Jan 2026, 6:00 pmClosed
GE PULGAON
GE PULGAON CAD PULGAON 442303
REPAIR REPLACEMENT OF INTERNAL ELECTRIC WIRING AND CONNECTED MISC ITEMS IN RA, CMPH, GUNJKHEDA AND BHIM LINE AT CAD PULGAON UNDER GE PULGAON
2026_MES_748051_1
8281/E8
Open Tender
Electrical and Maintenance Works
180 days
GE PULGAON
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE PULGAON
₹90,000
Yes
6 Mar 2026
10 Jan 2026
2 Feb 2026
10 Jan 2026
30 Jan 2026
24 Jan 2026
Taking down carefully conceled/ casing caping point wiring copper / aluminium (light / fan / scoket) complete (with fittings such as switches ceiling rose, pendents, regulators sockets etc) and making good disturbed surface with exisitng specification all as specified and directed by Engr-in-Charge.
All as per item No 2 above…. But for One bell point controlled by one switch one way.
All as per item No 2 above…. But for One ceiling fan / exhaust fan / wall mounting fan point controlled by one switch one way
All as per item No 2 above…. But for One socket outlet three pin 5/6 Amps controlled by one switch on the same board.
All as per item No 2 above…. But for One switch socket outlet three pin 5 /6 Amps controlled by one switch on independent board.
M&L point wiring complete with 1.5sqmm single core unsheathed PVC insulated FRLSH cable 1100 V grade multistranded copper conductor of different code of ISI marked drawn through and incl PVC casing caping of suitable size with accessories ISI marked incl PVC insulated copper cable for earth of same type and sized connected to earth dolly including metal box and provision of Modular Box,cover plate of suitable size for mounting switches / sockets and fan regulators etc complete all as specified and directed for the One light point controlled by one switch one way
All as per item No 7 above…. But for One bell point controlled by one switch one way.
All as per item No 7 above…. But for One ceiling fan / exhaust fan / wall mounting fan point controlled by one switch one way
All as per item No 7 above…. But for One socket outlet three pin 5/6 Amps controlled by one switch on the same board.
All as per item No 7 above…. But for One switch socket outlet three pin 5 /6 Amps controlled by one switch on independent board.
M&L for point wiring with stranded copper conductor 2.5 Sqmm (nominal area), single core, multistranded, FRLSH , PVC insulated and unsheathed cable 1100 volts grade, ISI marked drawn in and including heavy duty PVC concealed conduit with fittings ISI marked, terminated in junction box incl MS sunk terminal box including Modular Box,cover plate for mounting switches, socket and regulator including making good the disturbed surfaces complete all as specified and directed.
M&L for point wiring with stranded copper conductor 2.5 Sqmm (nominal area), single core, multistranded, FRLSH , PVC insulated and unsheathed cable 1100 volts grade, ISI marked drawn in and incl PVC casing caping of suitable size with accessories ISI marked incl PVC insulated copper cable for earth of same type and sized connected to earth dolly MS sunk terminal box including Modular Box,cover plate for mounting switches, socket and regulator complete all as specified and directed.
M&L for point wiring with stranded copper conductor 4 Sqmm (nominal area), single core, multistranded, FRLSH , PVC insulated and unsheathed cabel 1100 volts grade, ISI marked drawn in and incl PVC casing caping of suitable size with accessories ISI marked incl PVC insulated copper cable for earth of same type and sized connected to earth dolly MS sunk terminal box including Modular Box,cover plate for mounting switches, socket and regulator complete all as specified and directed.
M&L switch piano flush type single pole,one way, 5 Amps, 240 V complete all as specified and directed including taking down old U/S one.
S&F socket outlet 5/6 pin type,5 Amps, 240 V complete all as specified and directed including taking down old U/S one .
S&F switch socket combination 5/6 pin flush type (multipurpose type) 5 Amps, 240V complete all as specified and directed including taking down old U/S one. .
S&F switch socket combination flush type (multipurpose type) but 5A/16A, 5 in 1 15 Amps, 240V complete all as specified and directed including taking down old U/S one. .
S&F socket outlet Multipurpose type but 5A/15A flush type complete all as specified and directed including taking down old U/S one .
S&F Switch flush type 15/16A complete all as specified and directed including taking down old U/S one .
S&F bell switch piano flush type all as specified and directed
S&F Call bell ding dong electricaly operated all as specified and directed
S&F ceiling rose surface type with 3 terminals complete including taking down old U/S one .
S&F fan regulator electronic step type AC 240 Volts,50 Hz complete including taking down old U/S one .
S&F lamp holder,PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed including taking down old U/S one.
S&F in replacement LED tube light lamp ,220 V AC LED Tube Light Color Cool White Wattage 22/25 W Ultra Lumen 100-130 Lm/W Color Temperature 6500k Housing Material Extruded Aluminium with connecting up with 3 Core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make:- Jaquar Cat Part No LKBU4KVS35XC, Wipro Cat part No.-D532265 ,Phillips Cat part No.-919415920100 or Equivelent.
Supply and Fix in replacement to wall / pole of any height LED bldg security light 35 watt IP 65 including GI pipe suitable size bracket not less than 1 metre bend to shape with 2 clamps, nuts, bolts, washers and PVC 3 core ISI mark flexible wire from ceiling rose to fitting complete including taking down u/s lights all as specified and as directed.
Taking down carefully sub main wiring including batten/ conduit by unscrewing from wall, ceiling and making good surfaces to match with original status as specified and directed.
All as per item NO 29 above…. But for 2 run of 2.5sqmm copper cable and 1run of 2.5sqmmPVC FR copper cable for earth wire
All as per item NO 29 above…. But for 2 run of 4sqmm copper cable and 1run of 4 sqmmPVC FR copper cable for earth wire
All as per item NO 29 above…. But for 2 run of 6sqmm copper cable and 1run of 6 sqmmPVC FR copper cable for earth wire
M&L sub main wiring alongwith earth wire with the sizes of 2 run of 1.5sqmm copper cable and 1run of 1.5sqmm copper cable for earth wire FRLSH PVC insulated copper conductor, single core cable in PVC surface conduit 20mm complete all as sfecified and directed Note for sub main wiring :- 2 runs of wire and 1 run of earth wire will be measured as one unit i.e RM
All as per item No 33 above…. But for 2 run of 2.5sqmm copper cable and 1run of 2.5sqmm copper cable for earth wire
All as per item No 33 above…. But for 2 run of 4sqmm copper cable and 1run of 4 sqmm copper cable for earth wire
All as per item No 33 above…. But for 2 run of 6sqmm copper cable and 1run of 6 sqmm copper cable for earth wire
S&F in replacement of sheet steel enclosure with double door flush mounting ,MCB, DB, SPN, 4 ways,240 volt factory fitted rated bus bars,earth bar,neutral links complete incl. blanking plates as required & making good the disturbed surfaces.
S&F in replacement of sheet steel enclosure with double door flush mounting ,MCB, DB, SPN, 8 ways,240 volt factory fitted rated bus bars,earth bar,neutral links complete incl. blanking plates as required & making good the disturbed surfaces.
S&F in replacement of sheet steel enclosure with double door flush mounting ,MCB, DB, SPN, 12 ways,240 volt factory fitted rated bus bars,earth bar,neutral links complete incl. blanking plates as required & making good the disturbed surfaces.
S&F in replacement of sheet steel enclosure with Double door TPN 4 ways 440 volt factory fitted rated bus bars,earth bar,neutral links complete incl. blanking plates as required & making good the disturbed surfaces.
S&F in replacement of sheet steel enclosure with Double door TPN 8 ways 440 volt factory fitted rated bus bars,earth bar,neutral links complete incl. blanking plates as required & making good the disturbed surfaces.
S&F in replacement of MCB Protected Switch socket combination with box 4 pole MCB Protected Socket 4 Module, Short circuit breaking capacity, 3kA(MCBs) used for AC, Washing Machine, Oven, Geyser, etc., Mounting type: Either Concealed or Surface,Base material: Metal white color, cover plate white color with 16A 3 pin top, 20A SP MCB, 16A Socket and dummy complete all as specified and directed.
S and F in replacement of MCB TPN 63 Amps 415V ,50 Hz ,breaking capacity 10 KA," C " series all as directed.
S and F in replacement of MCB SPN 40 Amps 240V ,50 Hz, breaking capacity 10 KA," C " series all as directed.
S and F in replacement of MCB SPN 20 to 32Amps 240V ,50 Hz, breaking capacity 10 KA," C " series all as directed.
S&F MCB SP 6-32 Amps 240V ,50 Hz, breaking capacity 10 KA," C " series all as directed.
S&F modular metal box flush type 1/2 module including taking down U/S old complete all as specified and directed by EIC
S&F modular metal box flush type 3 moduleincluding taking down U/S old complete all as specified and directed by EIC
S&F modular metal box flush type 4 module including taking down U/S old complete all as specified and directed by EIC
S&F modular metal box flush type 6 module including taking down U/S old complete all as specified and directed by EIC
S&F modular metal box flush type 8 module including taking down U/S old complete all as specified and directed by EIC
S&F modular metal box flush type 12 module including taking down U/S old complete all as specified and directed by EIC
S&F modular cover plate with frame 2 moduleincluding taking down U/S old complete all as specified and directed by EIC
S&F modular cover plate with frame 3 module including taking down U/S old complete all as specified and directed by EIC
S&F modular cover plate with frame 4 module including taking down U/S old complete all as specified and directed by EIC
S&F modular cover plate with frame 6 module including taking down U/S old complete all as specified and directed by EIC
S&F modular cover plate with frame 8 module including taking down U/S old complete all as specified and directed by EIC
S&F modular cover plate with frame 12 module including taking down U/S old complete all as specified and directed by EIC
S&F Modular switch 1 way 6A, 1 module including taking down U/S old complete all as specified and directed by EIC
S& F Modular switch 1 way 16A, 1 module including taking down U/S old complete all as specified and directed by EIC
S&F Modular bell switch 6A, 1 module including taking down U/S old complete all as specified and directed by EIC
S& F Modular socket out let 3 pin 5 amp including taking down U/S old complete all as specified and directed by EIC
S& F Modular socket 6A / 16 Amp 2 / 3 pin including taking down U/S old complete all as specified and directed by EIC
S& F Modular fan step regulator 120W - 2 moudle including taking down U/S old complete all as specified and directed by EIC Note for Modular :- Colour of Box , plate , switch, socket, fan regulator will be approved before fixing.
Supply & fix with replace of LED recessed mounted 2'X2' 36 Watt light along with fixture including taking down U/S old complete all as specified and direceted by EIC.
Supply & fix LED recessed mounted 1'X1' 18 Watt light along with fixture including taking down U/S old complete all as specified and direceted by EIC.
Supply only electronic Driver suitable for LED reccessed mounted 2'x2' 35 watt complete all as specified and directed
Supply only electronic Driver suitable for LED reccessed mounted 1'x1' 18 watt complete all as specified and directed
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25M deep below ground level) with top edge of the plate not less than 1.5 M below ground level connected with galvanised earth wire 4 mm dia by means of bolts nuts check nuts and washers of galvanised iron to earth test point all as specified or indicated including necessary excavation and earth work any type of soil PCC (1:3:6) watering funnel, GI tubing 20 mm for watering all as specified and directed and all as shown in electrical plate No.5 of SSR part 1.
Supply and fixing multi strand three core 1.5 sqmm flexible copper conductor suitable for connection of ceiling fan from ceiling rose to ceiling fan complete.
Supply of Thermostat for Water Heater (Geyser) suitable to work up to 80' C, as per sample complete all as specified and directed.
Supply of Non-return valve 15 mm Brass for Geyser.
Supply of PVC connection pipe 15mm dia., 450mm long with chromium plated brass couplings on both ends suitable for 15 mm bore tubing for Geyser.
Supply of Heating element 2000 Watt for Geyser
Supply of Heating element 1500 Watt for Geyser
Supply of Water tank of capacity 25 Ltrs of suitable for existing water heater for Geyser.
Supply of Geyser bottom cover suitable for existing Geyser
Supply and fix LED decorative Post top/ Gate Light 40 watt IP 65 including suitable dia of base pipe not less than 1 feet inserted into ground/wall/gate piller for extra protection of light and 12mm Dia die steel bar caging for protaction opening on top fixed at gate with suitable size nuts, bolts washers etc in replacement all as specified and as directed.
Supply and fix LED Garden light 8 watt IP 66 made out of pressure die cast powder coated hoysing with PC diffuser including suitable dia of base pipe not less than 1 feet inserted into ground/wall/gate piller for extra protection of light and 12mm Dia die steel bar caging for protaction opening on top fixed at gate with suitable size nuts, bolts washers etc in replacement all as specified and as directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm all as specified and as directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 200mm all as specified and as directed.
Supply and fix exhaust fan made of sturdy Engineering Steel complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm all as specified and as directed.
Taking down the Solar water heater of the 250 Ltrs capacity from the site after disconnecting the water connection, electric connection, opening the Solar water heater assembly and descalling with hydrochloride solution fixing of Solar water heater assembly including repair of brass flange, ring nuts, bolts, washers and other connected works preparation of steel surface of water by rubbing with emery paper, filling of putty to match the existing surface , paintng the surface by spray painting with one coat of synthetic enamel paint of approved make without damaging other parts / wiring of the machine and refixing the same in its original position of electric back up with thermostat specified and making cold/hot waterconnection GI pipes as required to make the system functional and connecting up with hot concealed water pipe line complete all as specified and directed . Note :- Spares and accessories will be measured and paid seperately.
All as per item No 84 above…. But for 500 Ltrs capacity Solar water heater
Supply & fixing in repair of stop valve cast copper alloy screwed down high pressure with or without butterfly handle screwed down both end for iron pipe or for union 15mm dia ISI marked complete all as specified and directed.
Supply & fixing in repair of vent pipe made of GI pipe 15mm dia medium grade complete with all fitting ISI marked complete all as specified and directed.
Supply & fixing in repair GI tubing medium grade with all fittings and fixed to walls/ceiling/ floor or laid in trenches of 15 mm bore size for cold water pipe line complete all as specified and directed.
All as per Item No 88 but for 20mm bore size for hot water pipe line.
Supply & fixing in repair of hot water piping insulation with two layers of glass wool 25 MM thick covered with chicken wire mesh 24 Gauge and over all covering with aluminium sheet of 28 gauge all as specified and directed .
Supply & fixing in replacement insulated steel tank with inner protective coating for corosive resistance of 300 ltr capacity complete all as specified and directed
Supply & fixing in replacement insulated steel tank with inner protective coating for corosive resistance of 500 ltr capacity complete all as specified and directed
Supply & fixing in repair Flat plate collector consisting of transparent cover , riser tube, absober plate ,header tube with proper insulation steel tank complete all as specified and directed
Supply & fixing in repair of geyser element 4 KW with rubber ring round type complete with clamps, nuts and bolts washers etc for any make of geysers ISI marked complete as per sample complete all as specified and directed.
Supply and fix in replacement of 12 watt inverter LED Bulb retrofit type, 10 hrs Charging Time, 4 hrs Back-up Time Battery Capacity: 2200 mAh, rechargeable complete all as specified and directed.
Supply and Fix to ceiling 18 W Round Natural White 225 x 35 mm LED Panel Lights all as specified and as directed.
Supply and fixing ceiling fans complete with blades, down rods, clamp,and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) hanging complete all as specified and as directed.Havells Cat Part no. FHCEO5SWHT48 or equivenent Note:- Price includes taking out of OLD UNSV fan from site and deposite in E/M store as directed by Engr In charge.
Supply, installation, commisioning and testing factory made indoor type meter panel board conforming to IP 54/55 protection, of suitable size made of Robust steel sheet construction made from min 2 mm steel sheet totally enclosed dust proof duly painted with powder coated, fully wired up and ready to connect load & control lines housed with the following accessories:- INCOMING MCCB 160 A 25 KA 4 POLE THERMAL MAGNETIC - 01 Nos 2 OUTGOING MCCB 63 A 10 KA TP+N/L THERMAL MAGNETIC - 04 Nos 3 ENERGY METER 3 PHASE 0-60 A - 04 Nos 4 MCB 32 A 10 KA SPN - 05 Nos 5 ENERGY METER 1 PHASE 5-30 A - 05 Nos 6 INDICATING LIGHT RED 220V AC - 01 Nos 7 INDICATING LIGHT YELLOW 220V AC - 1 Nos 8 INDICATING LIGHT GREEN 220V AC - 1 Nos 9 PROTECTION MCB 6 A SP FOR INDICATING LIGHTS - 1 Nos 10 DANGER PLATE - 1 Nos 11 BUS BAR CHAMBER 250 A 4 STRIPS ALUMINIUM - 04 - Nos 12 ENCLOSURE OF SUITABLE SIZE
Please Enable Macros to View BoQ information
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BOQ_837719.xls
BOQ • 0.41 MB
TENDERDOCUMENTS8281.pdf
Tender Documents • 0.66 MB
Download all tender documents and submit your bid