Loading…
Loading…
Tender Value
₹20.5 Cr
EMD Value
₹20.5 L
Closing Date
9 Jun 2026, 11:00 am3d left
Construction of Phase-B (Bal.) work at Jawahar Navodaya Vidyalaya (JNV) in the districts of Bargarh, Gajapati, Sonepur and Malkangiri in Odisha.
NBCC/SBG/ODISHA/NIT/26-27/10
NBCC/SBG/ODISHA/NIT/26-27/10
Open Tender-Domestic
Civil Works - Buildings
Malkangiri, Odisha
₹11,800
₹20.5 L
26 May 2026
26 May 2026
9 Jun 2026
9 Jun 2026
ABSTRACT OF COST OF PACKAGE-1 (BARGARH,GAJAPATI,SONEPUR,MALKANGIRI-II)
AMOUNT BASED ON COST (IN LACS)
S.NO DESCRIPTION OF WORK
Schedule Amount Non Schedule Amount
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati,
Sonepur,Malkangiri-II in the state of Odisha.
TOTAL(A) 1797.39
SUB-TOTAL 1797.39
B DEVELOPMENT WORKS
PATHWAYS 18.52
EXTERNAL WATER SUPPLY SYSTEM 27.75
EXTERNAL SEWERAGE SYSTEM 39.91
APRON DRAIN - 45.32
SEPTIC TANK 40.04
HUME PIPE 5.84
RAIN WATER HARVESTING 34.72
EXTERNAL ELECTRIFICATION WORKS 36.00
SUB-TOTAL(C) 248.10
GRAND TOTAL 2045.49
GRAND TOTAL 2045.49
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST OF PACKAGE-1 (BARGARH,GAJAPATI,SONEPUR,MALKANGIRI-II)
S.N. DESCRIPTION OF ITEM DSR- QUANTITY UNIT RATES AMOUNT AMOUNT
2023 DSR ITEM [M.R. ITEM]
1 .Earth work in excavation by mechanical means (Hydraulic
excavator) / manual means in foundation trenches or drains
(not exceeding 1.5 m in width or 10 sqm on plan), including
dressing of sides and ramming of bottoms, lift upto 1.5 m,
including getting out the excavated soil and disposal of surplus
excavated soil as directed, within a lead of 50 m. All kinds of
2 Filling available excavated earth (excluding rock) in trenches,
plinth, sides of foundations etc. in layers not exceeding 20cm in
depth,consolidating each deposited layer by ramming and
watering, lead upto 50 m and lift upto 1.5 m.
3 Supplying and filling in plinth with sand under floors, including
watering, ramming,consolidating and dressing complete.
4 Excavating, supplying, stacking and filling of local earth
(including royalty)
by mechanical transport upto a lead of 5km also including
and watering of the earth in layers not exceeding 20 cm in
trenches, plinth, sides of foundation etc. complete for all lift.
B Concrete Work
5 Providing and laying in position cement concrete of specified
grade excluding the cost of centering and shuttering - All work
up to plinth level :1:4:8 (1 cement : 4 coarse sand
(zoneIII)derived from natural sources : 8 graded stone
aggregate 40 mm nominal size derived from natural sources)
6 Providing and laying damp-proof course 40mm thick with
cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III)
derived from natural sources : 4 graded stone aggregate
12.5mm nominal size derived from natural sources)
7 Providing & applying a coat of residual petroleum bitumen of
grade of VG-10 of approved quality using 1.7kg per square
metre on damp proof course after cleaning the surface with
brushes and finally with a piece of cloth lightly soaked in
8 Making plinth protection 50mm thick of cement concrete 1:3:6
(1 cement : 3 coarse sand (zone-III) derived from natural
sources : 6 graded stone aggregate 20 mm nominal size
derived from natural sources) over 75mm thick bed of dry brick
ballast 40 mm nominal size, well rammed and consolidated and
grouted with fine sand,including necessary excavation,levelling
& dressing & finishing the top smooth.
9 Brick edging in full brick width and half brick depth including
excavation, refilling and disposal of surplus earth lead upto 50
metres. With common burnt clay F.P.S. (non modular) bricks
of class designation 7.5 16.7.1 2111.72 RM 194.30 4,10,308.06
C Reinforced Cement Concrete
10 Centering and shuttering including strutting, propping etc. and
removal of form for all heights :
(a) Foundations, footings, bases of columns, etc. for mass
(b) Suspended floors, roofs, landings, balconies and access
(c) Lintels, beams, plinth beams, girders, bressumers 5.9.5 6131.90 SQM 736.40 45,15,531.47
(d) Columns,Pillars, Piers, Abutments, Posts and Struts. 5.9.6 4353.26 SQM 961.30 41,84,790.63
(e) Edges of slabs and breaks in floors and walls Under 20 cm
11 Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all complete
upto plinth level. Thermo-Mechanically Treated bars of grade
12 Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all complete
above plinth level. Thermo-Mechanically Treated bars of
13 Add for plaster drip course/ groove in plastered surface or
moulding to R.C.C. projections.
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST OF PACKAGE-1 (BARGARH,GAJAPATI,SONEPUR,MALKANGIRI-II)
S.N. DESCRIPTION OF ITEM DSR- QUANTITY UNIT RATES AMOUNT AMOUNT
2023 DSR ITEM [M.R. ITEM]
14 Providing and laying in position ready mixed or site batched
design mix cement concrete for reinforced cement concrete
work; using coarse aggregate and fine aggregate derived from
natural sources, Portland Pozzolana / Ordinary Portland
/Portland Slag cement, admixtures in recommended
proportions as per IS: 9103 to accelerate / retard setting of
concrete, to improve durability and workability without impairing
strength; including pumping of concrete to site of laying, curing,
carriage for all leads; but excluding the cost of centering,
shuttering, finishing and reinforcement as per direction of the
engineer-in-charge; for the following grades of concrete.
Note: Extra cement up to 10% of the minimum specified
cement content in design mix shall be payable separately. In
case the cement content in design mix is more than 110% of
the specified minimum cement content, the contractor shall
have discretion to either re-design the mix or bear the cost of
(I) All works upto plinth level 5.33.1
Concrete of M25 grade with minimum cement
content of 330 kg /cum 5.33.1.1
(iii) R.C.C. work in Columns 5.33.1.1 100.63 CUM 9504.75 9,56,464.77
(II) All works above plinth level upto floor V level 5.33.2
Concrete of M25 grade with minimum cement
content of 330 kg /cum 5.33.2.1
D Masonry Work
15 Half brick masonry with common burnt clay F.P.S. (non
modular) bricks of class designation 7.5 in superstructure
above plinth level up to floor V level.Cement mortar 1:4 (1
16 Extra for providing and placing in position 2 Nos 6mm dia. M.S.
bars at every third course of half brick masonry. 6.15 1168.32 SQM 104.80 1,22,439.57
17 Brick work with common burnt clay F.P.S. (non modular) bricks
of class designation 7.5 in superstructure above plinth level up
to floor V level in all shapes and sizes in : : Cement mortar 1:6
18 Brick work with non modular fly ash bricks conforming to
IS:12894, class designation 10 average compressive strength
in foundation and plinth in : Cement mortar 1:6 (1 cement : 6
E Cladding Work
Providing and fixing 18 mm thick gang saw cut, mirror polished,
premoulded and prepolished, machine cut for kitchen
platforms, vanity counters, window sills , facias and similar
locations of required size, approved shade, colour and texture
laid over 20 mm thick base cement mortar 1:4 (1 cement : 4
coarse sand), joints treated with white cement, mixed with
matching pigment, epoxy touch ups, including rubbing, curing,
moulding and polishing to edges to give high gloss finish etc.
complete at all levels.
Granite stone slab colour black, Cherry/Ruby red 8.2.2
21 Providing edge moulding to 18mm thick marble stone counters,
Vanities etc. including machine polishing to edge to give high
gloss finish etc. complete as per design approved by Engineer-
in-Charge. 8.3
22 Extra for fixing marble /granite stone over and above
corresponding basic item, in facia and drops of width upto 150
mm with epoxy resin based adhesive including cleaning etc.
23 Extra for providing opening of required size & shape for wash
basins/ kitchen sink in kitchen platform, vanity counters and
similar location in marble/Granite/stone work including
necessary holes for pillar taps etc. including moulding, rubbing
and polishing of cut edges etc. complete.
24 Providing and fixing Ist quality ceramic glazed wall tiles
conforming to IS: 15622 (thickness to be specified by the
manufacturer), of approved make, in all colours, shades except
burgundy, bottle green, black of any size as approved by
Engineer-in-Charge, in skirting, risers of steps and dados, over
12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse
sand) and jointing with grey cement slurry @ 3.3kg per sqm,
including pointing in white cement mixed with pigment of
matching shade complete.
F Wood and PVC Work
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST OF PACKAGE-1 (BARGARH,GAJAPATI,SONEPUR,MALKANGIRI-II)
S.N. DESCRIPTION OF ITEM DSR- QUANTITY UNIT RATES AMOUNT AMOUNT
2023 DSR ITEM [M.R. ITEM]
25 Providing and fixing ISI marked flush door shutters conforming
to IS : 2202 (Part I) non-decorative type, core of block board
construction with frame of 1st class hard wood and well
matched commercial 3 ply veneering with vertical grains or
cross bands and face veneers on both faces of shutters:35 mm
thick including ISI marked Stainless Steel butt hinges with
necessary screws 9.21.1 245.79 SQM 2392.65 5,88,087.60
26 Extra for providing lipping with 2nd class teak wood battens 25
mm minimum depth on all edges of flush door shutters (over all
area of door shutter to be measured).
27 Extra for cutting rebate in flush door shutters (Total area of the
shutter to be measured). 9.26 245.79 SQM 106.70 26,225.71
28 Providing and fixing M.S. grills of required pattern in frames of
windows etc. with M.S. flats, square or round bars etc. including
priming coat with approved steel primer all complete. Fixed to
steel windows by welding. 9.48.1 947.22 KG 219.10 2,07,535.85
29 Providing and fixing aluminium hanging floor door stopper ISI
marked anodised (anodic coating not less than grade AC 10 as
per IS : 1868) transparent or dyed to required colour or shade
with necessary screws etc. complete. Twin rubber stopper
30 Providing and fixing factory made 30 mm thick door shutter
made of solid PVC foam profile. The styles & rails shall be of
size 75 mm x 30 mm having wall thickness 5 mm. The styles,
top & bottom rails shall have one side wal thickness of 15 mm
integrally extruded on the hingeside of the profile for better
screw holding power. The styles and rails shall be reinforced
with M.S. tubes of size 33 mm x 17 mmx 1 mm, painted with
primer , all four corners of reinforcement to be welded or
sealed. Solid PVC extruded bidding (push fit type) will be set
inside the styles and the rails with a cavity, to receive single
piece extruded 5mm PVC sheet as panel. The styles and rails
will be mitred cut and joint with the help of PVC solvent cement
& self driven self tapping screws. Single piece extruded solid
PVC lock rail of size 100 mm x 30 mm with wall thickness 5 mm
& 15 mm integrally extruded in the middle of the lock rail &
fixed with styles with the help of PVC solvent cement & self
driven self tapping screws of size 100mm x 8 mm complete as
per manufacturer's specifications and direction of Engineer-in-
Non decorative finish
31 Providing and fixing stainless steel (SS-304 grade) friction
hinges to the side/top hung uPVC windows, of approved
quality, with necessary stainless steel screws etc. as per
direction of Engineer-in-charge. 200
32 Providing and fixing wire gauge shutters using stainless steel
grade 304 wire gauge with wire of dia 0.5 mm and average
width of aperture 1.4 mm in both directions for doors, windows
and clerestory windows with necessary screws : 30 mm thick
shutters With ISI marked stainless steel butt hinges of required
size Kiln seasoned and chemically treated hollock wood
33 Providing and fixing fly proof stainless steel grade 304 wire
gauge, to windows and clerestory windows using wire gauge
with average width of aperture 1.4 mm in both directions with
wire of dia. 0.50 mm all complete.With 12 mm mild steel U
beading 9.135.2 SQM 1228.00 -
34 Providing and fixing bright /matt finished Stainless Steel
handles of approved quality & make with necessary screws etc
35 Providing & fixing Stainless steel sliding door bolts ISI marked
anodised (anodic coating not less than grade AC 10 as per IS :
1868) transparent or dyed to required colour or shade with nuts
and screws etc complete. (a) 250mm x 16mm .
36 Providing and fixing stainless steel towerbolts (barrel type) with
necessary screws etc. complete.
37 Providing and fixing M.S. Tubular frames for doors, windows,
ventilators and cupboard with rectangular/ L-Type sections,
made of 1.60 mm thick M.S. Sheet, joints mitred, welded and
grinded finish, with profiles of required size, including fixing of
necessary butt hinges and screws and applying a priming coat
of approved steel primer. Fixing with 15x3 mm lugs 10 cm
long embedded in cement concrete block 15x10x10 cm of C.C.
1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20
mm nominal size)
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST OF PACKAGE-1 (BARGARH,GAJAPATI,SONEPUR,MALKANGIRI-II)
S.N. DESCRIPTION OF ITEM DSR- QUANTITY UNIT RATES AMOUNT AMOUNT
2023 DSR ITEM [M.R. ITEM]
38 Providing and fixing stainless steel ( Grade 304) railing made of
Hollow tubes, channels, plates etc., including welding, grinding,
buffing, polishing and making curvature (wherever required)
and fitting the same with necessary stainless steel nuts and
bolts complete, i/c fixing the railing with necessary accessories
& stainless steel dash fasteners , stainless steel bolts etc., of
required size, on the top of the floor or the side of waist slab
with suitable arrangement as per approval of Engineer-in-
39 Providing & fixing glass panes with putty and glazing clips in
steel doors, windows, clerestory windows, all complete with :
4.0 mm thick glass panes. 10.30.1 36.23 SQM 1064.65 38,568.93
Supply & fixing of Aluminium 3 Track Sliding windows as per
design & specifications with outer frame 86.5mm X 48mm,
Shutter section 65mm X 29mm, Mesh Shutter 66.7mm X
29mm, Powder coated (any RAL Colour), 6mm Clear tuffened
glass, Wire Mesh, Handle, EPDM Gasket, Silicon sealant with
complete hardware of reputed brand, MR 472.46 SQM 22278.00 1,05,25,435.49
41 Providing and fixing aluminium work for doors, windows,
ventilators and partitions with extruded built up standard
tubular sections/ appropriate Z sections and other
sections of approved make conforming to IS: 733 and IS:
1285, fixing with dash fasteners of required dia and size,
including necessary filling up the gaps at junctions, i.e. at
top, bottom and sides with required EPDM rubber/
neoprene gasket etc. Aluminium sections shall be smooth,
rust free, straight, mitred and jointed mechanically
wherever required including cleat angle, Aluminium snap
beading for glazing / paneling, C.P. brass / stainless steel
screws, all complete as per architectural drawings and the
directions of Engineer-in-charge. (Glazing, paneling and
dash fasteners to be paid for separately) :
For fixed portion 21.1.1
Powder coated aluminium (minimum thickness of powder
42 For shutters of doors, windows & ventilators including
providing and fixing hinges/ pivots and making provision
for fixing of fittings wherever required including the cost of
EPDM rubber / neoprene gasket required (Fittings shall be
paid for separately) 21.1.2
Powder coated aluminium (minimum thickness of powder
43 Providing and fixing glazing in aluminium door, window,
ventilator shutters and partitions etc. with EPDM rubber /
neoprene gasket etc. complete as per the architectural
drawings and the directions of engineer-in-charge . (Cost
of aluminium snap beading shall be paid in basic item):
With float glass panes of 8 mm thickness (weight not
44 Providing and fixing double action hydraulic floor spring of
approved brand and manufacture conforming to IS : 6315,
having brand logo embossed on the body / plate with
double spring mechanism and door weight upto 125 kg,
for doors, including cost of cutting floors, embedding in
floors as required and making good the same matching to
the existing floor finishing and cover plates with brass
pivot and single piece M.S. sheet outer box with slide
plate etc. complete as per the direction of Engineer-in-
With stainless steel cover plate minimum 1.25 mm
45 Filling the gap in between aluminium frame & adjacent
RCC/ Brick/ Stone work by providing weather silicon
sealant over backer rod of approved quality as per
architectural drawings and direction of Engineer-in-charge
complete. 21.8
Upto 5mm depth and 5 mm width 21.8.1 161.76 RM 96.75 15,650.57
46 Providing and fixing anodised aluminium grill (anodised
transparent or dyed to required shade according to IS:
1868 with minimum anodic coating of grade AC 15) of
approved design/pattern, with approved standard section
and fixed to the existing window frame with C.P.
brass/stainless steel screws @ 200 mm centre to centre,
including cutting the grill to proper opening size for fixing
and operation of handles and fixing approved anodised
aluminium standard section around the opening, all
complete as per requirement and direction of Engineer-
incharge.(Only weight of grill to be measured for
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST OF PACKAGE-1 (BARGARH,GAJAPATI,SONEPUR,MALKANGIRI-II)
S.N. DESCRIPTION OF ITEM DSR- QUANTITY UNIT RATES AMOUNT AMOUNT
2023 DSR ITEM [M.R. ITEM]
47 Chequerred precast cement concrete tiles 22 mm thick in
footpath & courtyard, jointed with neat cement slurry mixed with
pigment to match the shade of tiles, including rubbing and
cleaning etc. complete, on 20 mm thick bed of cement mortar
1:4 (1 cement: 4 coarse sand). Medium shade pigment using
50% white cement 50% Grey cement
48 Kota stone slab flooring over 20 mm (average) thick base laid
over and jointed with grey cement slurry mixed with pigment to
match the shade of the slab, including rubbing and polishing
complete with base of cement mortar 1 : 4 (1 cement : 4 coarse
49 Kota stone slabs 20 mm thick in risers of steps, skirting, dado
and pillars laid on 12 mm (average) thick cement mortar 1:3 (1
cement: 3 coarse sand) and jointed with grey cement slurry
mixed with pigment to match the shade of the slabs, including
rubbing and polishing complete.
50 Providing and laying Vitrified tiles in floor in different sizes
(thickness to be specified by the manufacturer) with water
absorption less than 0.08% and conforming to IS:15622, of
approved brand & manufacturer, in all colours and shade, laid
on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)
jointing with grey cement slurry @3.3 kg/sqm including grouting
the joints with white cement and matching pigments etc. The
tiles must be cut with the zero chipping diamond cutter only .
Laying of tiles will be done with the notch trowel, plier, wedge,
clips of required thickness, leveling system and rubber mallet
for placing the tiles gently and easily.Glazed Vitrified tiles
Matt/Antiskid finish of size
Size of Tile 600 x 600 mm
51 Providing and laying vitrified floor tiles in different sizes
(thickness to be specified by the manufacturer) with water
absorption less than 0.08% and conforming to IS: 15622, of
approved make, in all colours and shades, laid on 20mm thick
cement mortar 1:4 (1 cement : 4 coarse sand), jointing with
grey cement slurry @ 3.3kg/sqm including grouting the joints
with white cement and matching pigments etc., complete. Size
of Tile 600x600 mm
52 Providing and laying Vitrified tiles in different sizes (thickness to
be specified by manufacturer), with water absorption less than
0.08 % and conforming to I.S. 15622, of approved make, in all
colours & shade, in skirting, riser of steps, over 12 mm thick
bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing
with grey cement slurry @ 3.3kg/sqm including grouting the
joint with white cement & matching pigments etc. complete.
Size of Tile 600x600 mm
53 Providing and laying flamed finish Granite stone flooring in
required design and patterns, in linear as well a curvilinear
portions of the building all complete as per the architectural
drawings with 18 mm thick stone slab over 20 mm (average)
thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid
and jointed with cement slurry and pointing with white cement
slurry admixed with pigment of matching shade including
rubbing, curing and polishing etc. all complete as specified and
as directed by the Engineer-in-Charge :
Flamed finish granite stone slab Jet Black, Cherry Red, Elite
Brown, Cat Eye or equivalent.
54 Providing and laying Polished Granite stone flooring in required
design and patterns, in linear as well as curvilinear portions of
the building all complete as per the architectural drawings with
18 mm thick stone slab over 20 mm (average) thick base of
cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed
with cement slurry and pointing with white cement slurry
admixed with pigment of matching shade including rubbing,
curing and polishing etc. all complete as specified and as
directed by the Engineer-in-Charge.
Polished Granite stone slab of colour Black, Cherry/Ruby Red
55 Providing and laying 60mm thick faciory made cement concrete
interlocking paver block of M -30 grade made by block making
machine with strong vibratory compaction, of approved size,
design & shape, laid in required colour and pattern over and
including 50mm thick compacted bed of coarse sand, filling the
joints with line sand etc. all complete as per the direction of
Engineer-in-charge.
55 Providing and fixing 18 mm thick gang saw cut, mirror
polished, premoulded and prepolished, machine cut for
kitchen platforms, vanity counters, window sills, facias
and similar locations of required size, approved shade,
colour and texture laid over 20 mm thick base cement
mortar 1:4 (1 cement : 4 coarse sand), joints treated with 8.2
white cement, mixed with matching pigment, epoxy touch
ups, including rubbing, curing, moulding and polishing of
edges to give high gloss finish etc. complete at all levels
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST OF PACKAGE-1 (BARGARH,GAJAPATI,SONEPUR,MALKANGIRI-II)
S.N. DESCRIPTION OF ITEM DSR- QUANTITY UNIT RATES AMOUNT AMOUNT
2023 DSR ITEM [M.R. ITEM]
Granite stone slab of colour black, Cherry/Ruby red Area
of slab over 0.50 sqm 8.2.2 SQM
56 Providing and fixing tiled false ceiling of specified materials of
size 595x595 mm in true horizontal level, suspended on inter
locking metal grid of hot dipped galvanized steel sections (
galvanized @120 grams/ sqm, both side inclusive) consisting of
main "T" runner with suitably spaced joints to get required
length and of size 24x38
mm made from 0.30 mm thick (minimum) sheet, spaced at
1200mm center to center and cross "T" of size 24x25 mm
made of 0.30mm thick (minimum) sheet, 1200 mm long spaced
between main"T" at 600 mm center to center to form a grid of
1200x600 mm and secondary cross "T" of length 600 mm and
size 24x25 mm made of
0.30 mm thick (minimum) sheet to be interlocked at middle of
the1200x600 mm panel to form grids of 600x600 mm and wall
angle of size 24x24x0.3 mm and laying false ceiling tiles of
approved texture in the grid including, required cutting/making,
opening for services like diffusers, grills, light fittings, fixtures,
smoke detectors etc. Main
"T" runners to be suspended from ceiling using GI slotted cleats
of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia
and 50 mm long dash fasteners, 4 mm GI adjustable rods with
galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced
at 1200 mm center to center along main T, bottom exposed
width of 24 mm of all
T-sections shall be pre-painted with polyester paint, all
complete for all heights as per specifications, drawings and as
directed by Engineer-in-charge.
12.5 mm thick square edge PVC Laminated Gypsum
Tile of size 595x595 mm, made of Gypsum plasterboard,
manufactured from natural gypsum as per IS 2095 part I
and laminated with white 0.16mm thick fire retardant
PVC film on the face side and 12micron metalized
polyester on the back side with all edges sealed with the face
side PVC film which goes around and wraps
the edges and is bonded to the edges and the back side
metalized polyester film so as to make the tile a
completely sealed unit.
57 Providing & fixing at all heights, levels and locations Mill finish
Aluminium alloy roofing sheets of alloy IS designation 31500,
temper Hx8 conforming to IS 737 and dimensions as per IS
code 2676 with characteristics of good formability and
corrosion resistance. The profile sheets shall be fixed to truss
members in slope or required pitch or curvature with Hex cap
headed self drilling/tapping Stainless steel screws M6, 50 mm
long with 3 mm EPDM seal washer etc. all inclusive of labour,
scaffolding, T&P and sundries etc. complete as per directions
of the Engineer-In-Charge. (Cost of truss/frame work shall be
paid separately). 0.56 mm, Aluminium
troughed profile with center to center pitch of 200 mm, depth of
32 mm, overall profile width 1092 mm, cover width 1000 mm.
Providing and fixing of Pre-coated colour or mill finish
Aluminium Roofing Accessories in 0.71 mm thickness ,Alloy
31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO
designation)]. For colour, coating shall be 5-7 microns epoxy
primer on both sides of the sheet and polyester top coat 15-18
microns, using self drilling/tapping SS screws of size 6 x 50 mm
with 3 mm thick EPDM seal and SS plain washer complete :
58 Precoated/mill finish aluminium Ridges plain (500- 600mm)
59 Precoated/mill finish aluminium Flashings/ Aprons (Upto 600
60 Precoated/mill finish aluminium Gutter (600 mm over all girth)
61 Steel work in built up tubular (round, square or rectangular
hollow tubes etc.) trusses etc., including cutting, hoisting, fixing
in position and applying a priming coat of approved steel
primer, including welding and bolted with special shaped
62 Painting top of roofs with bitumen of approved quality @
17kg per 10 sqm impregnated with a coat of coarse sand
at 60 cudm per 10 sqm, including cleaning the slab
surface with brushes and finally with a piece of cloth lightly
soaked in kerosene oil complete :
With residual type petroleum bitumen of grade VG -10
63 Finishing with Epoxy paint (two or more coats) at all
locations prepared and applied as per manufacturer's
specifications including appropriate priming coat,
preparation of surface, etc. complete. On steel work. 13.52.1 5841.58 SQM 241.75 14,12,202.53
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST OF PACKAGE-1 (BARGARH,GAJAPATI,SONEPUR,MALKANGIRI-II)
S.N. DESCRIPTION OF ITEM DSR- QUANTITY UNIT RATES AMOUNT AMOUNT
2023 DSR ITEM [M.R. ITEM]
64 External Plaster in CM 1:4 with18mm thick in Two coats
comprising of first layer 12mm thick cement plaster finished
with a top layer 6mm thick cement plaster cement: 4 coarse
Rate for First layer 12mm thick cement plaster DSR item No. 13.4.1=Rs.
Rate for top layer 6mm thick cement plaster cement DSR item No. 13.4.1=Rs.
Total Rate For 18mm Thick Plaster=357.35+178.68=536.03
65 Extra for providing and mixing water proofing material in per bag of
cement of plaster work in proportion recommended by the . 50kg
manufacturers. cement
66 12mm cement plaster in single coat on fair side of single or half
brick wall for exterior plastering up to floor two level including
internal rounded angles chamfers, and/or rounded angles not
exceeding 80mm in girth and finished even and smooth no
extra for mixing any additive. 1:6 (1 cement: 6 coarse sand)
67 6 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand)
68 Wall painting with premium acrylic emulsion paint of interior
grade, having VOC (Volatile Organic Compound ) content less
than 50 grams/ litre of approved brand and manufacture,
including applying additional coats wherever required to
achieve even shade and colour.Two coats
69 Finishing walls with 100% Premium acrylic emulsion paint
having VOC less than 50 gm/litre and UV resistance as per IS
15489:2004, Alkali & fungal resistance, dirt resistance exterior
paint of required shade (Company Depot Tinted) with silicon
New work (Two or more coats applied @ 1.43 litre/ 10
sqm. Over and including priming coat of exterior primer
Steel Painting:Applying priming coat:
70 With ready mixed aluminium primer of approved brand and
manufacture on resinous wood and plywood
71 With ready mixed red oxide zink chromate primer of approved
brand and manufacture on steel galvanised iron/steel works.
72 Painting with synthetic enamel paint of approved brand and
manufacture to give an even shade: Two or more coats on
73 Providing and applying white cement based putty of average
thickness 1 mm, of approved brand and manufacturer, over the
plastered wall surface to prepare the surface even and smooth
Providing and laying APP (Atactic Polypropylene
Polymer) modified prefabricated five layer, 3 mm thick
water proofing membrane, black finished reinforced
with glass fibre matt consisting of a coat of bitumen
primer for bitumen membrane @ 0.40 litre/sqm by the
samemembrane manufactured of density at 25°C, 0.87 -
0.89 kg/litre and viscocity 70 - 160 cps. Over the primer
coat the layer of membrane shall be laid using butane
torch and sealing all joints etc., and preparing the 14.90.1 2727.69 SQM 537.45 14,65,995.88
surface complete. The vital physical and chemical
parameters of the membrane shall be as under : Joint
strength in longitudinal and transverse direction at 23°C
as 350/300 N/5 cm. Tear strength in longitudinal and
transverse direction as 60/80N. Softening point of
membrane not less than 150°C. Cold flexibility shall be
upto -2°C when tested in accordance with ASTM, D -
5147. The laying of membrane shall be got done through
the authorised applicator of the manufacturer of
membrane : 3 mm thick
Say in lacs 1,511.85 111.93
Sub Head – I Sanitary Installation
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST OF PACKAGE-1 (BARGARH,GAJAPATI,SONEPUR,MALKANGIRI-II)
S.N. DESCRIPTION OF ITEM DSR- QUANTITY UNIT RATES AMOUNT AMOUNT
2023 DSR ITEM [M.R. ITEM]
1.1 Providing and fixing water closet squatting pan (Indian
type W.C. pan ) with 100 mm sand cast Iron P or S trap,
10 litre low level white P.V.C. flushing cistern, including
flush pipe, with manually controlled device (handle lever)
conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and
floors wherever required:. 17.1 0.00
White Vitreous china Orissa pattern W.C. pan of size
580x440 mm with integral type foot rests. 17.1.1 41.00 each 6767.4 2,77,463.40
1.15 Providing and fixing soil, waste and vent pipes : 17.35 -
Hubless centrifugally cast (spun) iron pipes epoxy coated
1.16 Providing and fixing bend of required degree with access
door, insertion rubber washer 3 mm thick, bolts and nuts
complete. 17.38 -
Hubless centrifugally cast (spun) iron epoxy coated inside
1.17 Providing and fixing plain bend of required degree. 17.39 -
Hubless centrifugally cast (spun) iron pipe epoxy inside &
1.18 Providing and fixing heel rest sanitary bend 17.40 -
Sand cast iron S&S as per IS - 3989 17.40.1.2 80.00 each 548.7 43,896.00
1.19 Providing and fixing double equal plain junction of required
degree 17.42 -
Hubless centrifugally cast (spun) iron pipe epoxy inside &
1.20 Providing and fixing single equal plain junction of required
degree with access door, insertion rubber washer 3 mm
thick, bolts and nuts complete. 17.43 -
sand cast Iron S&S as per IS: 3989 17.43.1.2 80.00 each 925.7 74,056.00
1.21 Providing and fixing single equal plain junction of required
degree 17.44 -
Hubless centrifugally cast (spun) iron pipe epoxy inside &
1.22 Providing and fixing terminal guard: 17.56 -
Hubless centrifugally cast (spun) iron pipe epoxy inside &
1.23 Providing and fixing shielded coupling for Hubless
centrifugally cast iron pipes 17.57A -
S S 304 grade coupling with EPDM rubber gasket 17.57A.1.1 179.00 each 432.1 77,336.95
1.24 Providing and fixing M.S. stays and clamps for sand cast
iron/centrifugally cast (spun) iron pipes of diameter :
1.25 Painting sand cast iron/ centrifugally cast (spun) iron soil,
waste vent pipes and fittings with two coats of synthetic
enamel paint of any colour such as chocolate grey, or buff
etc. over a coat of primer (of approved quality) for new
100 mm diameter pipe 17.65.1 324.00 meter 82.8 26,827.09
1.26 Providing and fixing M.S. holder-bat clamps of approved
design to Sand Cast iron/cast iron (spun) pipe embedded
in and including cement concrete blocks 10x10x10cm of
1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone
aggregate 20mm nominal size) including cost of cutting
holes and making good the walls etc. :
1.27 Providing and fixing G.I. soil / waste pipes complete with
G.I. fittings and clamps, i/c cutting and making good the
walls etc. 18.10 -
32 mm dia. nominal bore 18.10.4 324.00 metre 667.0 2,16,107.14
40 mm dia. nominal bore 18.10.5 324.00 metre 811.9 2,63,054.55
50 mm dia. nominal bore 18.10.6 324.00 metre 1048.4 3,39,664.04
1.28 Providing and fixing trap of self cleansing design with
screwed down or hinged grating with or without vent arm
complete, including cost of cutting and making good the
walls and floors : 17.60 -
100 mm inlet and 100 mm outlet 17.60.1 -
Hubless centrifugally cast (spun) iron epoxy
coated inside & outside as per IS:15905 17.60.1.3 80.00 each 854.6 68,364.00
1.29 Cutting holes up to 15 x 15 cm in R.C.C. floors and roofs
for passing drain pipe etc. and repairing the hole after
insertion of drain pipe etc. with cement concrete 1:2:4 ( 1
Cement : 2 course sand : 4 graded stone aggregate 20
mm nominal size ) , including finishing complete so as to
make it leak proof. 18.77 80.00 each 452.0 36,160.00
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST OF PACKAGE-1 (BARGARH,GAJAPATI,SONEPUR,MALKANGIRI-II)
S.N. DESCRIPTION OF ITEM DSR- QUANTITY UNIT RATES AMOUNT AMOUNT
2023 DSR ITEM [M.R. ITEM]
1.30 Providing & fixing in position GI 100x50 elbow floor drain
including cost of cutting and making good the walls and
floors wherever required. NSI-4 80.00 each 1541.0 1,23,280.00
1.31 Providing and fixing 125 mm dia S/S grating (with or
without hole)for floor or Nahani trap. NSI-5 179.00 each 620.0 1,10,980.00
1.32 Providing and fixing soap dish holder from wall of
standard shape with fittings of approved quality NSI-6 80.00 each 1159.0 92,720.00
1.34 Providing & fixing 600 mm towel rail long stanless steel
from wall face with concealed fittings arrangement of
approved quality with all complete. NSI-8 80.00 each 2025.0 1,62,000.00
1.35 Providing and fixing PTMT soap Dish Holder having
length of 138mm, breadth 102mm, height of 75mm with
concealed fitting arrangements, weighing not less than
136 Providing and fixing PTMT towel rail complete with
brackets fixed to wooden cleats with CP brass screws
with concealed fittings arrangement of approved quality
and colour. 17.73 -
600 mm long towel rail with total length of 645 mm, width
78 mm and effective height of 88 mm, weighing not less
1.37 Making khurras 45x45 cm with average minimum
thickness of 5 cm cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate of 20 mm
nominal size) over P.V.C. sheet 1 m x1 m x 400 micron,
finished with 12 mm cement plaster 1:3 (1 cement : 3
coarse sand) and a coat of neat cement, rounding the
edges and making and finishing the outlet complete.
1.38 Providing and fixing on wall face unplasticised Rigid PVC
rain water pipes conforming to IS : 13592 Type A,
including jointing with seal ring conforming to IS : 5382,
leaving 10 mm gap for thermal expansion,
(i) Single socketed pipes. 12.41.2 324.00 metre 377.4 1,22,277.11
1.39 Providing and fixing on wall face unplasticised - PVC
moulded fittings/ accessories for unplasticised Rigid PVC
rain water pipes conforming to IS : 13592 Type A,
including jointing with seal ring conforming to IS : 5382,
leaving 10 mm gap for thermal expansion. 12.42 -
Coupler 12.42.1 -
Single tee with door 12.42.3 0.00 -
Shoe (Plain) 12.42.6 0.00 -
1.40 Providing and fixing unplasticised -PVC pipe clips of
approved design to unplasticised - PVC rain water pipes
by means of 50x50x50 mm hard wood plugs, screwed
with M.S. screws of required length, including cutting brick
work and fixing in cement mortar 1:4 (1 cement : 4 coarse
sand) and making good the wall etc. complete.
1.41 Supplying and fixing of HDPE pipe (PE grade 63 - PN-8 )
confirming to IS 14333-1996 chemical waste pipes jointed
with rubber ring with good quality lubricant with fittings
inclussive of all necessary specials like bends, tees,
offsets,junctions etc laid under floor/under ceiling/on walls
with suitable clamps and specials curing, necessary
chasing, jointing and restoring to original conditions,
testing etc. including all other incidental charges etc.
complete for successful completion of work as per
specifications, and as directed by Engineer -in- Charge.
50 mm outer dia b) metre 558.0 -
1.42 Providing & fixing in position upvc P"or S" trap of self
cleaning design of following sizes for the embedded
areas Making proper connection with chemical sealent
joint , cutting chase / hole in floors /slabs and bringing the
same in proper condition in cement concrete 1:2:4 mix
complete as required. including cost of cutting and making
good the walls and floors wherever required.
1.43 Providing & Fixing water cooler wth stainless steel having
storage capacity of 80 liter & cooling capacity 60 liter /
hour with Reverse osmosis system & ultra voilet
membrane TDS reduction 90% having automatic back
wash system with filteration unit & all other required
accessories complete in all respect as per direction of the
engineer in charge . NSI-11 each 65604.0 -
Sub Head – II Water Supply
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST OF PACKAGE-1 (BARGARH,GAJAPATI,SONEPUR,MALKANGIRI-II)
S.N. DESCRIPTION OF ITEM DSR- QUANTITY UNIT RATES AMOUNT AMOUNT
2023 DSR ITEM [M.R. ITEM]
2.1 Providing and fixing G.I. pipes complete with G.I. fittings
and clamps, i/c cutting and making good the walls etc.
Internal work – Exposed on wall.
20 mm nominal outer dia Pipes 18.10.2 516.87 metre 437.3 2,26,028.66
25 mm nominal outer dia Pipes 18.10.3 516.87 metre 551.7 2,85,158.96
32 mm nominal outer dia Pipes 18.10.4 metre 667.0 -
40 mm nominal outer dia Pipes 18.10.5 metre 811.9 -
50 mm nominal outer dia Pipes 18.10.6 metre 1048.4 -
2.2 Providing and fixing Chlorinated Polyvinyl Chloride
(CPVC) pipes, having thermal stability for hot & cold water
supply, including all CPVC plain & brass threaded fittings,
i/c fixing the pipe with clamps at 1.00 m spacing.This
includes jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per
direction of Engineer in Charge.
Concealed including cutting chases and making good the
15 mm nominal outer dia Pipes 18.8.2 516.87 metre 497.8 2,57,299.49
20 mm nominal outer dia Pipes 18.8.3 243.95 metre 537.6 1,31,148.58
25 mm nominal outer dia Pipes 18.8.4 243.95 metre 627.3 1,53,018.87
2.3 Providing and fixing gun metal gate valve with C.I. wheel
of approved quality (screwed end) : 18.17 -
20 mm dia. nominal bore 18.17.1A 129.00 each 540.0 69,653.55
25 mm dia. nominal bore 18.17.1 80.00 each 622.4 49,792.00
32 mm dia. nominal bore 18.17.2 179.00 each 689.6 1,23,438.40
40 mm dia. nominal bore 18.17.3 0.00 each 826.1 -
50 mm dia. nominal bore 18.17.4 0.00 each 1026.7 -
2.4 Providing and fixing ball valve (brass) of approved quality,
High or low pressure, with plastic floats complete :
2.7 Providing and placing on terrace (at all floor levels)
polyethylene water storage tank, IS : 12701 marked, with
cover and suitable locking arrangement and making
necessary holes for inlet, outlet and overflow pipes but
without fittings and the base support for tank
2.8 Providing and fixing C.P. brass long nose bib cock of
approved quality conforming to IS standards and weighing
not less than 810 gms. 18.51 -
2.9 Providing and fixing C.P. brass stop cock (concealed) of
standard design and of approved make conforming to
2.11 Providing and fixing uplasticised PVC connection pipe
with brass unions : 18.21 -
45 cm length 18.21.2 -
SUBHEAD – III Drainage
3.1 Supply and fixing HDPE double wall corrugated ( DWC )
I.S 16098 ( Part - 2 ) 3013 for soil / waste pipe under
ground drainage system with jointed with rubber ring with
good quality lubricant for fittings, inclusive of all necessary
specials like bends, tees, offsets, junctions, re excavtion
and refillig etc complete.
150 mm diameter a metre 1024.0 -
3.2 Providing and fixing square-mouth S.W. gully trap class
SP-1 complete with C.I. grating brick masonry chamber
with water tight C.I. cover with frame of 300 x300 mm size
(inside) the weight of cover to be not lessthan 4.50 kg and
frame to be not less than 2.70 kg as per standard design :
180x150 mm size P type 19.4.3
With fly ash bricks (non modular) bricks of class
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST OF PACKAGE-1 (BARGARH,GAJAPATI,SONEPUR,MALKANGIRI-II)
S.N. DESCRIPTION OF ITEM DSR- QUANTITY UNIT RATES AMOUNT AMOUNT
2023 DSR ITEM [M.R. ITEM]
3.4 Constructing brick masonry manhole in cement mortar
1:4 (1 cement :4 coarse sand) with RCC top slab with
1:2:4 mix ( 1 cement : 2 coarse sand : 4 stone aggregate
20 mm nominal size ) , foundation concrete 1:4:8 mix (1
cement : 4 coarse sand : 8 stone aggregate 40 mm
nominal size ) inside plastering 12 mm thick with cement
mortar 1:3 (1 cement : 3 coarse sand) finished with a
floating coat of neat cement, foundation cocreate 1:3:6
mix (1 cement :3 coarse sand : 6 graded stone aggregate
40 mm norminal size),and making necessary channel in
cement concrete 1:2:4 (1 cement :2 coarse sand :4
graded stone aggregate 20 mm norminal size) finished
with a floating coat of neat cement complete as per
standard design .
inside size 90x80 cms and 45 cms deep including CI
cover with frame ( light duty ) 455x610 mm internal
dimensions total weight of cover & frame to be not less
than 38 kg (weight of cover 23 kg & weight of frame 15 kg
with common brunt clay FPS ( non modular ) bricks of
class designation 7.5 19.7.1.1 32.00 Each 12770.6 4,08,657.60
3.5 Extra depth for manhole 90x80 cm 19.8 -
With FPS bricks class designation 7.5 19.8.1.1 19.77 Metre 8825.4 1,74,458.15
3.6 Providing orange colour safety foot rest of minimum 6 mm
thick plastic encapsulated as per IS : 10910, on 12 mm
dia steel bar conforming to IS:1786, having minimum
cross section as 23 mmx25 mm and over all minimum
length 263 mm and width as 165 mm with minimum 112
mm space between protruded legs having 2 mm tread on
top surface by ribbing or chequering esides necessary
and adequate anchoring projections on tail length on 138
mm as per standard drawing and suitable to with stand
the bend test and chemical resistance test as per
pecifications and having manufacture’s permanent
identification mark to be visible even after fixing,including
fixing in manholes with 30x20x15 cm cement concrete
block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone
aggregate 20 mm nominal size) complete as per design.
3.7 Constructing brick masonry road gully chamber 50x45x60
cm with bricks in cement mortar 1:4 (1 cement : 4 coarse
sand) including 500x450 mm pre-cast R.C.C. horizontal
grating with frame complete as per standard design :
With common burnt clay F.P.S. (non modular) bricks of
class designation 7.5 19.27.1 80.00 Each 5957.9 4,76,632.00
Say in lacs 55.18 15.13
ELECTRICAL WORK
SUB HEAD - I: CIRCUIT CUM POINT WIRING
SWITCH CONTROL LIGHT POINTS
Wiring for light point/ fan point/ exhaust fan point/ call bell
point with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable in surface / recessed medium
1 class PVC conduit, with modular switch, modular plate, DSR 1.10
suitable GI box and earthing the point with 1.5 sq.mm
FRLS PVC insulated copper conductor single core cable
etc. as required.
Wiring for group controlled (looped) light point/fan
point/exhaust fan point/ call bell point ( without
Independent switch etc.) with 1.5 sq. mm FRLS PVC
2 insulated copper conductor single core cable in
surface/ recessed PVC conduit, and earthing the point
with 1.5 sq. mm FRLS PVC insulated copper conductor
single core cable etc as required. (Switch Control
Secondary Points)
2.1 Group C DSR-1.55.3
MCB CONTROL LIGHT POINTS
Wiring for light point/ fan point/ exhaust fan point/ call
bell point with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable in surface / recessed steel
5 conduit, with modular switch, modular plate, suitable NSI-1
GI box and earthing the point with 1.5 sq.mm FRLS
PVC insulated copper conductor single core cable etc.
as required. (Switch Control Primary Points)
5.1 Primary point controlled by one MCB. NSI-1.1 70.00 Point 1523.13 1,06,618.79
Same as item above but Secondary point. i.e. Points to
5.2 be looped with Primary point with 2.5 sqmm wire and NSI-1.2
Point wiring 70.00 Point 1354.89 94,842.52
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST OF PACKAGE-1 (BARGARH,GAJAPATI,SONEPUR,MALKANGIRI-II)
S.N. DESCRIPTION OF ITEM DSR- QUANTITY UNIT RATES AMOUNT AMOUNT
2023 DSR ITEM [M.R. ITEM]
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC
insulated copper conductor single core cable in surface/
6 recessed steel conduit alongwith 1 No. 4 sq. mm FRLS DSR 1.5
PVC insulated copper conductor single core cable for loop
earthing as required. 2241.31 Metre 433.00 9,70,486.67
Wiring for circuit/ submain wiring alongwith earth wire with
the following sizes of FRLS PVC insulated copper
conductor, single core cable in surface/ recessed steel
conduit as required. -
7.3 2 X 6 sq. mm + 1 X 6 sq. mm earth wire DSR 1.7.4 960.56 Metre 589.00 5,65,770.35
7.4 2 x 10 sq. mm + 1 x 10 sq.mm earth wire DSR 1.7.5 0.00 Metre 710.00 -
Supplying and fixing suitable size GI box with modular
plate and cover in front on surface or in recess including
8 providing and fixing 3 pin 5/6 Amp modular socket outlet DSR 1.31
and 5/6 A modular switch, connection etc. as required.
Supply and Wiring for 250 volts single phase and neutral
2 Nos 6 amps socket outlate with control by 1 No
switched with 2.5 sq.mm PVC insulated copper
conductor 1100 volts grade stranded flexible FRLS wires
in concealed or surface mounted 25 mm dia 2mm thick
PVC conduit including providing and fixing of 6 amps 3 pin
9 switch socket outlet of aprpoved make and design in 2 NSI-2
mm thick GI box with grid plate and earthing of third pin
of the socket with 2.5 Sq. mm PVC insulated copper
conductor stranded flexible FRLS wire.(maximum four
no. of switches socket shall be connected on one
Supplying and fixing suitable size GI box with modular
plate and cover in front on surface or in recess, including
10 providing and fixing 6 pin 5/6 & 15/16 A modular socket DSR 1.32
outlet and 15/16 A modular switch, connections etc. as
Supplying and fixing 3 pin, 5 A ceiling rose on the
13 existing junction box/ wooden block including connections DSR-1.33
etc. as required. 384.00 Each 87.00 33,408.00
Supplying & fixing suitable size GI box wih modular plate
and cover in front on surface or in recess i/c providing and
fixing 25 amp modular socket outlet and 25 Amps modular
SP MCB, “C” curve including connection, painting etc. as
required. (AC's & Gysers)
Supplying and fixing of following sizes of medium class
PVC conduit along with accessories in surface/recess
18 including cutting the wall and making good the same in DSR 1.21
case of recessed conduit as required.
TOTAL CARRIED TO SUMMARY FOR SUBHEAD - I
SUBHEAD -II - FITTINGS & FIXTURES
Supply, Installation, Testing and Commissioning of 10 W
Bulk head Light. 64.00 Each 1158.20 74,124.49
Supply, Installation, Testing and Commissioning of 5W
Mirror Light. 64.00 Each 445.46 28,509.42
Supply, Installation, Testing and Commissioning of 18W
3 Surface/Recessed Mounted LED circular Downlighter. NSI-3
Supply, Installation, Testing and Commissioning of
18/20W Wall/Surface mouted 4 ft. LED 384.00 Each 1336.38 5,13,169.56
Supply, Installation, Testing and Commissioning of 15W
Surface mounted LED Square Downlighter. 64.00 Each 1380.93 88,379.20
Supply, Installation, Testing and Commissioning of 9W
(Nominal) Wall Bracket Light 128.00 Each 222.73 28,509.42
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST OF PACKAGE-1 (BARGARH,GAJAPATI,SONEPUR,MALKANGIRI-II)
S.N. DESCRIPTION OF ITEM DSR- QUANTITY UNIT RATES AMOUNT AMOUNT
2023 DSR ITEM [M.R. ITEM]
Supply, Installation, Testing and Commissioning of 1200
mm sweep, BEE 5 star rated, ceiling fan with Brush Less
Direct Current (BLDC) Motor, class of insulation: B, 3 nos.
blades, 30 cm long down rod, 2nos. canopies, shackle kit,
safety rope, copper winding, Power Factor not less than
0.9, Service Value (CM/M/W) minimum 6.00, Air delivery
minimum 210 Cum/Min , 350 RPM (tolerance as per IS :
9 374-2019),THD less than 10%, remote or electronic DSR 1.21
regulator unit for speed control and all remaining
accessories including safety pin, nut bolts, washers,
temperature rise=75 degree C (max.), insulation
resistance more than 2 mega ohm, suitable for 230 V, 50
Hz, single phase AC Supply, earthing etc. complete as
Supply Installation, Testing and Commissioning of 250
mm dia Domestic Exhaust Fan 128.00 Each 2260.41 2,89,332.60
TOTAL CARRIED TO SUMMARY FOR SUBHEAD - II
SUBHEAD - III - DISTRIBUTION BOARDS
Supplying and fixing following way, three pole and neutral,
sheet steel, MCB distribution board, 415 volts, on surface/
recess complete with tinned copper busbar, neutral
2 busbar, earth bar, din bar, detachable gland plate, DSR 2.4
interconnections, phosphatized and powder painted
including earthing etc. as required. (But without MCB/
RCCB/ Isolator)
2.1 4 way (4 + 12), Double door DSR 2.4.1 Each 4091.00 -
Supplying and fixing of following ways surface/ recess
mounting, vertical type, 415 V, TPN MCB distribution
board of sheet steel, dust protected, duly powder painted,
inclusive of 200 A tinned copper bus bar, common neutral
3 link, earth bar, din bar for mounting MCBs (but without DSR 2.5
MCBs and incomer) as required . (Note :Vertical type
MCB TPDB is normally used where 3 phase outlets are
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA,
"C" curve, miniature circuit breaker suitable for inductive
4 load of following poles in the existing MCB DB complete DSR 2.10
with connections, testing and commissioning etc. as
Supplying and fixing following rating, double pole, (single
phase and neutral), 240 V, residual current circuit breaker
(RCCB), having a sensitivity current 30 mA in the existing
MCB DB complete with connections, testing and
commissioning etc. as required.
Supplying and fixing single pole blanking plate in the
existing MCB DB complete etc. as required. 60.00 Each 13.00 780.00
TOTAL CARRIED TO SUMMARY FOR SUBHEAD - III
IV SUB HEAD-IV , LIGHTNING CONDUCTOR -
LIGHTNING CONDUCTOR -
1 Providing and fixing of lightning conductor finial, made of 6.2
25 mm dia 300 mm long, G.I. tube, having single prong at
top, with 85 mm dia 6 mm thick G.I. base plate including
holes etc. complete as required. 64.00 Each 518.00 33,152.00
2 Fixing of lightning conductor finial (single prong) with base 6.3
plate including holes etc. complete as required. 64.00 Each 360.00 23,040.00
3 Jointing copper / G.I. tape (with another copper/ G I tape, 6.4
base of the finial or any other metallic object) by riveting /
nut bolting/ sweating and soldering etc as required.
4 Providing and fixing G.I. tape 20 mm X 3 mm thick on 6.7
parapet or surface of wall for lightning conductor complete
as required.(For horizontal run) 1440.84 Metre 126.00 1,81,546.00
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST OF PACKAGE-1 (BARGARH,GAJAPATI,SONEPUR,MALKANGIRI-II)
S.N. DESCRIPTION OF ITEM DSR- QUANTITY UNIT RATES AMOUNT AMOUNT
2023 DSR ITEM [M.R. ITEM]
5 Providing and fixing G.I. tape 20 mm X 3 mm thick on 6.8
parapet or surface of wall for lightning conductor complete
as required.(For vertical run) 960.56 Metre 197.00 1,89,230.49
6 Fixing of copper/ G.I. tape 20 mm X 3 mm thick on 6.10
parapet or surface of wall for lightning conductor complete
as required.(For vertical run) 480.28 Metre 162.00 77,805.43
7 Providing and fixing testing joint, made of 20 mm X 3 mm 6.12
thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts,
nuts, chuck nuts and spring washers etc. complete as
8 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm 5.4
thick including accessories, and providing masonry
enclosure with cover plate having locking arrangement
and watering pipe of 2.7 metre long etc. with charcoal/
coke and salt as required. Details of cost for one Set
9 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm 5.11
dia G.I. pipe from earth electrode including connection
with G.I. nut, bolt, spring, washer excavation and re-filling
etc. as required. 165.82 Metre 706.00 1,17,068.92
TOTAL CARRIED TO SUMMARY FOR SUBHEAD - IV
SUB TOTAL(I+II+III+IV) 88,97,965.35 14,31,604.77
Say in lacs 88.98 14.32
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
PATHWAYS 2.00 MT. WIDE
Sl. RATE AMOUNT On DSR AMOUNT OF M.R
DESCRIPTION OF ITEM DSR-2023 QTY UNIT
No. (In Rs.) ( In Rs.) ITEM ( In Rs.)
1. Earth work in excavation by mechanical means (Hydraulic
excavator)/ manual means over areas (exceeding 30 cm in
depth, 1.5 m in width as well as 10 sqm on plan) including
getting out and disposal of excavated earth lead upto 50 m
and lift upto 1.5 m, as directed by Engineer-incharge
All kinds of soil 2.6.1 66.15 Cum 177.50 11742.35
2 Providing and laying in position cement concrete of specified
grade excluding the cost of centering and shuttering. All
work upto plinth level.
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from
natural sources : 8 graded stone aggregate 40 mm nominal
size derived from natural sources)
3 Providing and laying 60mm thick faciory made cement
concrete interlocking paver block of M -30 grade made by
block making machine with strong vibratory compaction, of
approved size, design & shape, laid in required colour and
pattern over and including 50mm thick compacted bed of
coarse sand, filling the joints with line sand
etc. all complete as per the direction of Engineer-in-charge.
4 Providing and laying at or near ground level factory made
kerb stone of M-25 grade cement concrete in position to the
required line, level and curvature, jointed with cement mortar
1:3 (1 cement: 3 coarse sand), ncluding making joints with
or without grooves (thickness of joints except at sharp curve
shall not to more than 5mm), including making drainage
opening wherever required complete etc. as per direction of 16.69 35.58 Cum 10117.60 359984.21
Engineer-in-charge (length of finished kerb edging shall be
measured for payment). (Precast C.C. kerb stone shall be
approved by Engineer-in-charge).
5 Painting with synthetic enamel paint of approved brand and
manufacture of required colour to give an even shade :
Two or more coats on new work over an under coat of
suitable shade with ordinary paint of approved brand and 13.62.1 105.01 Sqm 226.25 23757.71
6 Supplying and stacking at site. 16.3
7 Filling available excavated earth (excluding rock) in
trenches, plinth, sides of oundations etc. in layers not
exceeding 20cm in depth, consolidating each deposited
layer by ramming and watering, lead up to 50 m and lift upto
8 Centering and shuttering including strutting, propping etc.
and removal of form for all heights :
a Foundations, footings, bases of columns, etc. for mass
SAY IN LACS 18.52 -
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST
08 NOS RAIN WATER HARVESTING
Sl. RATE AMOUNT On DSR AMOUNT OF M.R
DESCRIPTION OF ITEM DSR-2023 QTY UNIT
No. (In Rs.) ( In Rs.) ITEM ( In Rs.)
Recharge Pit (2000x2000)
1 Earth work in excavation by mechanical means (Hydraulic
excavatior)/manual means over areas(exceeding 30cm in
depth. 1.5m in width as well as 10sqm on plan) including
disposal of excavated earth, lead upto 50m and lift upto
1.5m, disposed earth to be levelled and neatly dressed.
a upto 1.5m depth
b In all kind of soil upto 1.5m to 3.0m. depth -
all kinds soil 2.8.1+
c In all kind of soil upto 3.0m to 4.5m. depth -
all kinds soil 2.9.1+
d In all kind of soil upto 3.0m to 4.5m. depth -
all kinds soil 2.9.1+
2 Providing and laying in position cement concrete of
specified grade excluding the cost of centering and
shuttering -All work up to plinth level: 1:5:10 (1 cement : 5
coarse sand (zone-III) derived from natural sources : 10
graded stone aggregate 40 mm nominal size derived
from natural sources) 4.1 -
3 Brick work with common burnt clay F.P.S. (non modular)
bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1:6 (1 cement : 6 coarse sand) 6.1.2 105.12 Cum 7132.25 7,49,742.12
4 Reinforced cement concrete work inbeams, suspended
floors, roofs having slope up to 15º landings, balconies,
shelves, chajjas, intels, bands plain window sills,
staircases and spiral stair cases up to floor five level
excluding the cost of centering, shuttering, finishing and
reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand :3
graded stone aggregate 20mm nominal size)
5 Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in position and
binding all complete upto plinth level.
Mild steel and Medium Tnsile steel bars. 5.22.1 105.12 Kg 107.10 11,258.35
6 Centring and shuttering including struting , proping etc
and removal of form for :
Suspended floors, roofs, landings, balconies and access
platform. 5.9.3 Sqm 927.25 -
7 Edges of slabs and breaks in floors and walls
8 12 mm cement plaster on rough side of single or half 13.4
9 Providing and fixing in position precast RCC manhole
cover and frame of required shape and approved quality.
HD-20- Circular shape 560mm internal diameter 19.19.3.1 16 No. 1675.70 26,811.20
10 Boring/drilling bore well of required dia for casing/ strainer
pipe, by suitable method prescribed in IS: 2800 (part I),
including collecting samples from different strata,
preparing and submitting strata chart/bore log, including
hire & running charges of all equipments, tools, plants &
machineries required for the job, all complete as per
direction of Engineer-incharge, upto 90 metre depth
below ground level. 23.1
Rockey strata including Boulders (300 mm dia 23.1.1.1 160 M 707.75 1,13,240.00
11 Supplying, assembling, lowering and fixing in vertical
position in bore well unplasticized PVC medium well
screen (RMS) pipes with ribs, conforming to IS: 12818,
including hire & labour charges, fittings & accessories
etc. all complete, for all depths, as per direction of
Engineer-in-charge. 23.4
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST
08 NOS RAIN WATER HARVESTING
Sl. RATE AMOUNT On DSR AMOUNT OF M.R
DESCRIPTION OF ITEM DSR-2023 QTY UNIT
No. (In Rs.) ( In Rs.) ITEM ( In Rs.)
12 Supplying, filling, spreading & leveling stone boulders of
size range 5 cm to 20cm, in recharge pit, in the required
thickness, for all leads & lifts, all complete as per
direction of Engineer-in-charge. 23.5 12.56 cum 1,509.80 18,963.09
13 Supplying, filling, spreading & leveling gravels of size
range 5 mm to 10mm, in the recharge pit, over the
existing layer of boulders, in required thickness, for all
leads & lifts, all complete as per direction of Engineer-in-
14 Supplying, filling, spreading & leveling coarse sand of
size range 1.5 mm to 2 mm in recharge
pit, in required thickness over gravel layer, for all leads &
lifts, all complete as per direction of
Engineer -in-charge. 23.7 12.56 cum 1538.25 19,320.42
15 Gravel packing in tubewell construction in accordance
with IS: 4097, including providing gravel
fine/medium/coarse, in required grading & size as per
actual requirement, all complete as per direction of
Engineer-in-charge. 23.8 8 Cum 2024.50 16,196.00
Disilting Chamber (4000x2000x2000 )
1 Earth work in excavation by mechanical means (Hydraulic
excavatior)/manual means over areas(exceeding 30cm in
depth. 1.5m in width as well as 10sqm on plan) including
disposal of excavated earth, lead upto 50m and lift upto
1.5m, disposed earth to be levelled and neatly dressed.
a upto 1.5m depth
b upto 1.5m to 3.0m. depth -
c upto 3.0m to 4.5m. depth -
all kinds soil 2.8.1+2.26.1*
2 Providing and laying in position cement concrete of
specified grade excluding the cost of centering and
shuttering -All work up to plinth level: 1:5:10 (1 cement : 5
coarse sand (zone-III) derived from natural sources : 10
graded stone aggregate 40 mm nominal size derived
from natural sources) 4.1 -
3 Brick work with common burnt clay F.P.S. (non modular)
bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1:6 (1 cement : 6coarse sand) 6.1.2 96.48 Cum 7132.25 6,88,119.48
4 Reinforced cement concrete work inbeams, suspended
floors, roofs having slope up to 15º landings, balconies,
shelves, chajjas, intels, bands plain window sills,
staircases and spiral stair cases up to floor five level
excluding the cost of centering, shuttering, finishing and
reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand :3
graded stone aggregate 20mm nominal size)
5 Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in position and
binding all complete upto plinth level.
Mild steel and Medium Tnsile steel bars. 5.22.1 912 Kg 107.10 97,675.20
6 Centring and shuttering including struting , proping etc
and removal of form for :
Suspended floors, roofs, landings, balconies and access
7 Edges of slabs and breaks in floors and walls
8 12 mm cement plaster on rough side of single or half
brick wall mix 13.4
9 Providing M.S. foot rests including fixing in manoholes
with 20x20x10 cm cement concrete blocks 1:3:6
(1cement : 3 coarse sand : 6 graded stone aggregate
20mm nominal size) as per standard design:
With 20x20mm square bar 19.15.1 160 Nos. 544.70 87,152.00
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST
08 NOS RAIN WATER HARVESTING
Sl. RATE AMOUNT On DSR AMOUNT OF M.R
DESCRIPTION OF ITEM DSR-2023 QTY UNIT
No. (In Rs.) ( In Rs.) ITEM ( In Rs.)
10 Providing and fixing in position precast RCC manhole
cover and frame of required shape and approved quality.
LD-2.5 Rectangular shape 600x450mm internal
Earth work in excavation by mechanical means (Hydraulic
excavator) / manual means in
foundation trenches or drains (not exceeding 1.5 m in
width or 10 sqm on plan), including
dressing of sides and ramming of bottoms, for all lift,
including getting out the excavated soil
and disposal of surplus excavated soil as directed, within
a lead of 50 m. 2.8
All kinds of soil. 2.8.1 8.024 Cum 260.30 2,088.65
Providing and laying in position cement concrete of
2.0 specified grade excluding the cost of
centering and shuttering - All work up to plinth level : 4.1 -
1:5:10 (1 cement : 5 coarse sand (zone-iii) derived from
natural sources : 10 graded stone
aggregate 40 mm nominal size derived from natural
3.0 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from
natural sources : 4 graded stone
aggregate 20 mm nominal size derived from natural
4.0 12 mm cement plaster of mix : 13.4 -
5.0 Brick work with common burnt clay F.P.S. (non modular)
bricks of class designation 7.5 in
foundation and plinth in: 6.1 -
Cement mortar 1:6 (1 cement : 6 coarse sand) 6.1.2 3.352 Cum 7132.25 23,907.30
6.0 Reinforced cement concrete work in beams, suspended
floors, roofs having slope up to 15°
landings, balconies, shelves, chajjas, lintels, bands, plain
window sills, staircases and spiral
stair cases above plinth level up to floor five level,
excluding the cost of centering, shuttering,
finishing and reinforcement with 1:1.5:3 (1 cement : 1.5
coarse sand(zone-III) derived from
natural sources : 3 graded stone aggregate 20 mm
nominal size derived from natural sources). 5.3 0.8 Cum 11505.50 9,204.40
7.0 Steel reinforcement for r.c.c. work including straightening,
cutting, bending, placing in
position and binding all complete upto plinth level. 5.22 -
cold twisted bars 5.22.3 44 Kg 107.85 4,745.40
8.0 Supplying and fixing C.I. cover without frame for
manholes 19.18 -
455x610 mm rectangular C.I. cover (light duty) the weight Details of
of the cover to be not less than 23 cost for
TOTAL [C] 67,687.77
TOTAL -PART(A)+PART(B)+PART(C) 34,72,494.62
SAY IN LACS 34.72 -
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST
EXTERNAL WATER SUPPLY
AMOUNT On DSR AMOUNT OF M.R
S.NO DESCRIPTION OF ITEM DSR-2023 QUANTITY UNIT RATES
( In Rs.) ITEM ( In Rs.)
EXTERNAL WATER SUPPLY PIPES AND FITTINGS
DISTRIBUTION NETWORK FOR FRESH WATER SUPPLY
1 Providing and fixing G.I. pipes complete with G.I. fittings 18.12
including trenching and refilling etc.
20 mm dia nominal bore 18.12.2 49.17 metre 368.60 18124.64
25 mm dia nominal bore 18.12.3 40.40 metre 467.75 18899.23
32 mm dia nominal bore 18.12.4 61.75 metre 540.30 33363.71
40 mm dia nominal bore 18.12.5 960.18 metre 617.05 592479.07
50 mm dia nominal bore 18.12.6 0.00 metre 762.15 0.00
65 mm dia nominal bore 18.12.7 35.45 metre 896.60 31783.82
80 mm dia nominal bore 18.12.8 0.00 metre 1,041.70
2 Painting G.I. pipes and fittings with two coats of anti- 18.40
corrosive bitumastic paint of approved quality :
20 mm diameter pipe 18.40.2 49.17 metre 12.00 590.06
25 mm diameter pipe 18.40.3 40.40 metre 15.25 616.17
32 mm diameter pipe 18.40.4 61.75 metre 18.40 1136.21
40 mm diameter pipe 18.40.5 960.18 metre 20.95 20115.77
50 mm diameter pipe 18.40.6 0.00 metre 25.25 0.00
65 mm diameter pipe 18.40.7 35.45 metre 31.30 1109.56
80 mm diameter pipe 18.40.8 0.00 metre 36.40
3 Providing and filling sand of grading zone V or coarser grade 18.41
alround the GI pipes in external work.
20mm dia nominal bore 18.41.2 49.17 metre 156.55 7697.81
25mm dia nominal bore 18.41.3 40.40 metre 160.70 6493.01
32mm dia nominal bore 18.41.4 61.75 metre 164.90 10182.63
40mm dia nominal bore 18.41.5 960.18 metre 167.00 160350.06
50 mm diameter pipe 18.41.6 0.00 metre 173.25 0.00
65 mm diameter pipe 18.41.7 35.83 metre 273.45 9797.84
80 mm diameter pipe 18.41.8 0.00 metre 281.80
4 Providing and fixing C.I. double acting air valve of 18.59
approved quality with bolts, nuts, rubber insertions etc.
complete (The tail pieces, tapers etc if required will be paid
5 Providing and fixing gun metal gate valve with C.I. wheel of 18.17
approved quality (screwed end) :
20 mm nominal bore 18.17.1A 125.00 Each 539.95 67493.75
80 mm nominal bore 18.17.6 0.00 Each 2,604.55
6 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from
natural sources : 4 graded stone aggregate 20 mm nominal 4.1.3 52.62 Cum 7,878.50 414566.67
size derived from natural sources)
7 Providing and fixing G.I. Union in GI pipe including cutting 18.46
and threading the pipe and making long screws etc.
complete(New work)
80 mm nominal bore 18.46.8 0.00 Each 1207.95
8 Providing and fixing in position pre-cast R.C.C. manhole 19.19
cover and frame of required shape and approved quality
Rectangular shape 600*450 mm internal dimensions 19.19.1.1 113.00 Each 1437.65 162454.45
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST
EXTERNAL WATER SUPPLY
AMOUNT On DSR AMOUNT OF M.R
S.NO DESCRIPTION OF ITEM DSR-2023 QUANTITY UNIT RATES
( In Rs.) ITEM ( In Rs.)
9 Constructing masonry gate valve Chamber 30x30x50 cm 18.32
inside, in brick work in cement mortar 1:4 (1 cement :4
coarse sand) for stop cock, with C. I. surface box 100x100
x75 mm (inside) with hinged cover fixed in cement concrete
slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size), i/c necessary excavation,
foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10
graded stone aggregate 40mm nominal size ) and inside
plastering with cement mortar 1:3 (1 cement : 3 coarse sand)
12mm thick, finished with a floating coat of neat cement
complete as per standard design :
With common burnt clay F.P.S.(non modular) bricks of class 18.32.1
designation 7.5
10 Constructing masonry Chamber 60x45x50 cm inside, in 18.33
brick work in cement mortar 1:4 (1 cement : 4 coarse sand)
for water meter complete with C.I. double flap surface box
400x200x200 mm (inside) with locking arrangement and
RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded
stone aggregate 20 mm nominal size) , i/c necessary
excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine
sand:10 graded stone aggregate 40 mm nominal size) and
inside plastering with cement mortar 1:3 (1 cement : 3
coarse sand) 12 mm thick, finished with a floating coat of
neat cement complete as per standard design :
with common burnt clay F.P.S.(non module) brick of class 18.33.1
designation 7.5
SAY IN LACS 27.75 -
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST
EXTERNAL SEWER SYSTEM
Rate AMOUNT On DSR AMOUNT OF M.R ITEM
S. No DESCRIPTION DSR-2023 QTY Unit
EXTERNAL SEWARAGE SYSTEM
Excavating trenches of required width for pipes, cables, etc
including excavation for sockets, and dressing of sides, ramming
of bottoms, depth upto 1.5 m, including getting out the excavated
soil, and then returning the soil as required, in layers not
exceeding 20 cm in depth, including consolidating each deposited
layer by ramming, watering, etc. and
disposing of surplus excavated soil as directed, within a lead of 50
All kinds of soil 2.10.1
Pipes, cables etc. exceeding 80 mm dia but not exceeding 300
Supply and fixing HDPE double I.S 16098 ( Part - 2 ) 3013 for soil
/ waste pipe under ground drainage system with jointed with
rubber ring with good quality lubricant for fittings, inclusive of all
necessary specials like bends, tees, offsets, junctions, re
excavtion and refillig etc complete.
Providing and laying in position cement concrete of specified
grade excluding the cost of centering and shttering - All work up to
3 plinth level 1:5:10 (1 cement : 5 coarse sand (zone-III): 10
graded stone aggregate 40 mm nominal size).
Constructing brick masonry manhole in cement mortar 1 : 4 (1
cement : 4 coarse sand) with RCC top slab with 1 : 2 : 4 mix (1
cement : 2 coarse sand : 4 grade stone aggregate 20mm nominal
size); foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8
graded stone aggregate 40 mm nominal size) inside plastering
12 mm thick with cement mortar 1:3 (1cement 3 coarse sand )
finished with a floating coat of neat cement and making channels
in cement concrete 1:2:4 (1cement : 2 coarse sand: 4 graded
stone aggregate 20 mm nominal size) finishd with a floating coat of
neat cement complete as per standard design
Inside size 90 x 80 cm & 45 cm deep including CI cover with
frame (light duty) 455 x 610mm internal dimensions, total weight of
cover & frame to be not less than 38 kg (weight of cover 23 kg
and weight of frame 15 kg)
With common burnt clay F.P.S.(non modular) bricks of classic
5 Extra for depth for manholes: 19.8 -
size 90 X 80 cm
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
Constructing Brick Masonry circular type manhole 0.91 m internal
dia at bottom and 0.56m dia at top with FPS bricks class
designation 75 in cement mortar 1:4 (1 cement : 4 Coarse sand),
inside cement plaster 12mm thick with cement mortar 1:3 ( 1
cement : 3 coarse sand) finished with a floating coat of of neat
cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand
: 6 graded stone aggregate 40mm nominal size) and making
necessary channel in Cement Concrete 1:2:4 ( 1 Cement : 2
Coarse Sand : 4 Graded Stone Aggregate 20mm nominal size)
finished with a floating coat of neat cement complete as per
standard design.
0.91m deep with SFRC cover and frame (heavy duty HD-20 grade
designation) 560mm internal diameter conforming to I.S:12592,
total weight of cover and frame to be not less than 182Kg. fixed in
cement concrete 1:2:4 mix (1cement: 2 coarse sand: 4 graded
stone aggregate 20mm nominal size) including centering,
shuttering all complete.(Excavation foot rests and 12mm thick
cement plaster at the external surface shall be paid for separately)
with common burnt clay F.P.S.(non module) brick of class
Extra depth for circuler type manholes 0.91 m internal dia ( at
bottom ) beyond 0.91m to 1.67 m .
with common burnt clay F.P.S.(non module) brick of class
designation 7.5 19.10.1
Providing and fixing square mouth S. W. Gully trap class SP-1
complete with C.I. grating brick masonry chamber with water
8 tight CI cover with frame of 300 x 300 mm size (inside) the weight
of cover to be not less than 4.50 kg and frame to be not less than
2.70 kg as per standard design 19.4 -
180 x 150 mm. size P type 19.4.3 -
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST
EXTERNAL SEWER SYSTEM
Rate AMOUNT On DSR AMOUNT OF M.R ITEM
S. No DESCRIPTION DSR-2023 QTY Unit
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
Providing M.S. foot rests including fixing in manholes with
20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse
sand : 6 graded stone aggregate 20 mm nominal size) as per
standard design : 19.15 -
With 20 mm dia round bar 19.15.1 79.00 each 496.50 39,223.50
Say in lacs 39.91
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST
AMOUNT On DSR AMOUNT OF M.R
S.NO DESCRIPTION OF ITEM DSR-2023 QUANTITY UNIT RATES
( In Rs.) ITEM ( In Rs.)
A APPRON DRAIN (250 X300MM)-1482.64 Mtr
1 Earth work in excavation by mechanical means (Hydraulic
excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m
in width as well as 10 sqm on plan) including getting out and disposal of
excavated earth lead upto 50 m and lift upto 1.5 m, as directed by
Engineer-in-charge.
all kinds of soil 2.6.1 556.80 cum 177.50 98831.49
2 Filling available excavated earth (excluding rock) in trenches, plinth,
sides of foundations etc. in layers not exceeding 20cm in depth:
consolidating each deposited layer by ramming and watering, lead up to
Qty. = 25% of them no 1
3 Providing and laying in position cement concrete of specified grade
excluding the cost of centering and shttering - All work up to plinth level
1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate
40 mm nominal size). 4.1.10 215.56 cum
4 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate) finished with a floating coat of neat cement, including
cement slurry, but excluding the cost of nosing of steps etc. complete
40 mm thick with 20 mm nominal size stone aggregate
5 Providing and laying damp-proof course 40mm thick with cement
concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded 410.85
stoneaggregate 12.5mm nominal size) 4.10 718.43 sqm 295168.30
6 Centering and shuttering including strutting, propping etc. and removal
of form for all heights :
Foundations, footings, bases of columns, etc. for mass concrete 5.9.1 412.25 Sqm 392.15 161663.84
7 Brick work with F.P.S. bricks of class designation 75 in foundation and
Cement mortar 1:6 (1 cement : 6 coarse sand) 6.1.2 231.56 Cum 7132.25 1651543.81
8 12 mm cement plaster finished with a floating coat of neat cement of
SAY IN LACS 45.32 -
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST
Sl. Description of Item DSR-2023 QTY Unit Rate AMOUNT On DSR AMOUNT OF M.R
No. (In Rs.) ( In Rs.) ITEM ( In Rs.)
A Spectic Tank for 50 Users
Size of Tank = 5.00 X 2.00 X 1.24 Mtr
Excavation work by mechanical means (Hydraulic
excavator)/ manual means in foundation trenches or drains
(not exceeding 1.5m in width or 10 sqm on plan), including
1.0 dressing of sides and ramming of bottoms, lift upto 1.5 m,
including getting out the excavated soil and disposal of
surplus excavated soils as directed, within a lead of 50 m.
2.0 Extra for every additional lift of 1.5 m or part thereof in excavation /
banking excavated or stacked materials.
All kinds of soil
Filling available excavated earth (excluding rock) in trenches,
plinth, sides of foundations etc. in layers not exceeding 20cm
3.0 in depth, consolidating each deposited layer by ramming and 10,717.28
watering, lead up to 50 m and lift up to 1.5 m.
Providing and laying in position cement concrete of specified
4.0 grade excluding the cost of centering and shuttering - All work up -
to plinth level
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone
aggregate 40 mm nominal size) 4.1 8.5 CUM 6518.60 55,408.10
Providing and laying in position machine batched and machine
mixed design mix M-25 grade cement concrete for reinforced
cement concrete work, using cement content as per approved
design mix, including pumping of concrete to site of laying but
excluding the cost of centering, shuttering, finishing and
5.0 reinforcement, including admixtures in recommended proportions -
as per IS: 9103 to accelerate, retard setting
of concrete, improve workability without impairing strength and
durability as per direction of
Engineer-in-charge.
(Note :- Cement content considered in this item is @ 330 kg/cum.
Excess/less cementused as per design mix is payable/recoverable -
All works upto plinth level 5.33.1 40.68 CUM 9504.75 3,86,653.23
6.0 Centering and shuttering including strutting, propping etc.
and removal of form for:
Foundations, footings, bases of columns, etc. for mass
concrete. 23.48 Sqm 392.15
7.0 Walls (any thickness) including attached pilasters,
plinth and string courses etc. 5.9.2 193 Sqm 842.50 1,62,602.50
Lintels, beams, plinth beams, girders, bressumers and
cantilevers with waterproof ply 12mm thick 5.9.21 12 SQM 841.95
Suspended floors, roofs, landings, balconies and access
platform with waterproof ply 12mm thick 5.9.20 40 SQM 1028.40 41,136.00
10.0 Edges of slabs and breaks in floors and walls. 5.9.16
11.00 Providing and fixing tie bolt, spring coil and plastic cone in
wall shuttering complete as per the direction of Engineer-in-
Steel reinforcement for R.C.C. work including straightening,
12.0 cutting, bending, placing inposition and binding all complete
upto plinth level. 5.22
Thermo-Mechanically Treated bars TMTC-500-8mm dia. 5.22.6 5126 Kg 107.85 5,52,839.10
6 mm cement plaster on rough side of single or half brick
wall of mix: 13.16 -
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST
Sl. Description of Item DSR-2023 QTY Unit Rate AMOUNT On DSR AMOUNT OF M.R
No. (In Rs.) ( In Rs.) ITEM ( In Rs.)
Providing and fixing in position pre-cast R.C.C. manhole
cover and frame of required shape and approved quality -
Circular shape 560 mm internal diameter 19.19.3.1 8 Nos 1675.70 13,405.60
Providing orange colour safety foot rest of minimum 6 mm
thick plastic encapsulated as per IS : 10910 on 12mm dia
steel bar conforming to IS : 1786 having minimum cross
section as 23 mmx25mm and over all minimum length 263
mm and width as 165mm with minimum 112 mm space
between protruded legs having 2 mm tread on top surface
by ribbing or chequering besides necessary and adequate
anchoring projections on tail length on 138 mm as per
standard drawing and suitable to with stand the bend test
and chemical resistance test as per specifications and
having manufacture’s permanent identification mark to be
visible even after fixing, including fixing in manholes with
30x20x15 cm cement concrete block 1:3:6 (1 cement : 3
coarse sand : 6 graded stone aggregate 20 mm nominal
size) complete as per design.
17.0 Providing and fixing soil, waste and vent pipes 17.35 -
Centrifugally cast (spun) iron socketed pipe as per IS: 3989.
18.0 Providing and fixing terminal guard : -
Sand cast iron S&S as per IS - 3989 17.56.1.2 4 Nos 506.00 2,024.00
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45
cm dry brick honey comb shaft with bricks of class
designation 75 and S.W. drain pipe 100 mm diameter, 1.8m
long complete as per standard design.With F.P.S. bricks 19.32.1 4 Nos 26861.90 1,07,447.60
SAY IN LACS 17.12 -
B Spectic Tank for 100 Users
Size of Tank = 5.70 X 2.10 X 1.70 Mtr
Excavation work by mechanical means (Hydraulic
excavator)/ manual means in foundation trenches or drains
(not exceeding 1.5m in width or 10 sqm on plan), including
1.0 dressing of sides and ramming of bottoms, lift upto 1.5 m,
including getting out the excavated soil and disposal of
surplus excavated soils as directed, within a lead of 50 m.
2.0 Extra for every additional lift of 1.5 m or part thereof in excavation /
banking excavated or stacked materials.
All kinds of soil 2.8.1
ordinary rock 2.9.1
Filling available excavated earth (excluding rock) in trenches,
plinth, sides of foundations etc. in layers not exceeding 20cm in
3.0 depth, consolidating each deposited layer by ramming and
watering, lead up to 50 m and lift up to 1.5 m.
Providing and laying in position cement concrete of specified
4.0 grade excluding the cost of centering and shuttering - All work up
to plinth level :
1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone
aggregate 40 mm nominal size). 4.1.10 10.08 Cum 6518.60 65707.49
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST
Sl. Description of Item DSR-2023 QTY Unit Rate AMOUNT On DSR AMOUNT OF M.R
No. (In Rs.) ( In Rs.) ITEM ( In Rs.)
Providing and laying in position machine batched and machine
mixed design mix M-25 grade cement concrete for reinforced
cement concrete work, using cement content as per approved
design mix, including pumping of concrete to site of laying but
excluding the cost of centering, shuttering, finishing and
5.0 reinforcement, including admixtures in recommended proportions
as per IS: 9103 to accelerate, retard setting
of concrete, improve workability without impairing strength and
durability as per direction of
Engineer-in-charge.
(Note :- Cement content considered in this item is @ 330 kg/cum.
Excess/less cementused as per design mix is payable/recoverable
All works upto plinth level 5.33.1 61.8 Cum 9504.75 587393.55
6.0 Centering and shuttering including strutting, propping etc.
and removal of form for:
Foundations, footings, bases of columns, etc. for mass
7.0 Walls (any thickness) including attached pilasters,
plinth and string courses etc. 5.9.2 350.92 Sqm 842.50 295650.10
Lintels, beams, plinth beams, girders, bressumers and
cantilevers with waterproof ply 12mm thick 5.9.21 21.68 Sqm 841.95 18253.48
Suspended floors, roofs, landings, balconies and access
platform with waterproof ply 12mm thick 5.9.20 47.88 SQM 1028.40 49239.79
10.0 Edges of slabs and breaks in floors and walls. 5.9.16
11.00 Providing and fixing tie bolt, spring coil and plastic cone in
wall shuttering complete as per the direction of Engineer-in-
Steel reinforcement for R.C.C. work including straightening,
12.0 cutting, bending, placing inposition and binding all complete
upto plinth level. 5.22
Thermo-Mechanically Treated bars TMTC-500-8mm dia. 5.22.6 5251 Kg 107.85 566320.35
52 mm thick cement concrete flooring with concrete
hardener topping under layer 50 mm thick cement concrete
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate
20mm nominal size) and top layer 12mm thick cement
hardener consisting of mix 1:2 (1 cement hardener mix : 2
graded stone aggregate 6mm nominal size) by volume.
Hardening compound is mixed @ 2 litre per 50kg of cement
or as per manufactures specifications. This includes cost of
cement slurry, but excluding the cost of nosing of steps etc.
6 mm cement plaster on rough side of single or half brick
wall of mix: 13.16
Providing and fixing in position pre-cast R.C.C. manhole
cover and frame of required shape and approved quality
Circular shape 560 mm internal diameter 19.19.3.1 8 Nos 1675.70 13405.60
Providing orange colour safety foot rest of minimum 6 mm
thick plastic encapsulated as per IS : 10910 on 12mm dia
steel bar conforming to IS : 1786 having minimum cross
section as 23 mmx25mm and over all minimum length 263
mm and width as 165mm with minimum 112 mm space
between protruded legs having 2 mm tread on top surface
by ribbing or chequering besides necessary and adequate
anchoring projections on tail length on 138 mm as per
standard drawing and suitable to with stand the bend test
and chemical resistance test as per specifications and
having manufacture’s permanent identification mark to be
visible even after fixing, including fixing in manholes with
30x20x15 cm cement concrete block 1:3:6 (1 cement : 3
coarse sand : 6 graded stone aggregate 20 mm nominal
size) complete as per design.
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST
Sl. Description of Item DSR-2023 QTY Unit Rate AMOUNT On DSR AMOUNT OF M.R
No. (In Rs.) ( In Rs.) ITEM ( In Rs.)
17.0 Providing and fixing soil, waste and vent pipes 17.35
Centrifugally cast (spun) iron socketed pipe as per IS: 3989.
18.0 Providing and fixing terminal guard :
Sand cast iron S&S as per IS - 3989 17.56.1.2 4 Nos 506.00 2024.00
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45
cm dry brick honey comb shaft with bricks of class
designation 75 and S.W. drain pipe 100 mm diameter, 1.8m
long complete as per standard design.With F.P.S. bricks 19.32.1 4 Nos 26861.90 107447.60
SAY IN LACS 22.92 -
TOTAL -PART(A)+PART(B) 40,03,800.55
SAY IN LACS 40.04 -
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST
QTY Unit Rate AMOUNT On DSR AMOUNT OF M.R ITEM (
S. No DESCRIPTION DSR-2023
1 Excavating trenches of required width for pipes, cables, etc including 2.10
excavation for sockets, and dressing of sides, ramming of bottoms, depth
upto 1.5 m, including getting out the excavated soil, and then returning the
soil as required, in layers not exceeding 20 cm in depth, including
consolidating each deposited layer by ramming, watering, etc. and disposing
of surplus excavated soil as directed, within a lead of 50 m :
All kinds of soil 2.10.1
Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm 2.10.1.3 115.12 metre 549.75 63,287.22
2 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with 19.6
collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1
cement : 2 fine sand) including testing of joints etc. complete :
3 Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 coarse
sand : 10 gradded stone aggregate 40 mm nominal size) alround S.W.
Pipes including bed concrete as per standard design. 4.1.10 51.26 cum 6518.60 3,34,143.44
Say in lacs 5.84
Digitally signed by JAYA
Construction of Phase-B (bal.) Work at at JNV's Bargarh, Gajpati, Sonepur,Malkangiri-II in the state of Odisha.
ABSTRACT OF COST
EXTERNAL ELECTRIFICATION WORKS
Rate AMOUNT On DSR AMOUNT OF M.R
S. No DESCRIPTION NSI QTY Unit
(In Rs.) ( In Rs.) ITEM ( In Rs.)
1 Design, Manufacturing, supplying, fixing in position, testing and
commissioning of the following front operated front access 2mm
thick CRCA steel enclosure free standing, water, dust and
vermin proof outdoor type Feeder pillars with IP-55 protection
or aboved hinged and lockable doors complete with
interconnections copper crimping lugs, brass glands bonding to
earth and painting, suitable for use at 415 volts, 3 phase 4 wire
50 Hz system . The panels fault withstanding capacity shall be
of 25 MVA at 415 volts. All live accessories part shall be
shrouded and all equipment shall be finger touch proof. The bus
bars shall be of colure coded with Heat shrinkable PVC
insulated sleeves.
FEEDER PILLAR-1:
1 No.200A, 415V, Ics=25kA, 4P MCCB with thermal magnetic
1 No. Digital multifunction meter (V+A+Hz) with a set of cast
resin CTs 160/5A.
1 Set of Phase indicating lamp with MCB
250A TPN bus bars of aluminium alloy.
For emergency supply
1 No. 63A, 415V, Ics=25kA, 4P MCCB with thermal magnetic
1 Set of On indicating lamp with MCB
100A TPN bus bars of aluminium alloy.
OUT GOING BUS-I :
8 Nos. 63A 415V, 4P MCCB of 15kA .
1 No. MCB Space.
OUT GOING BUS-II :
5 Nos. 63A 415V, 4P MCB of 10kA .
1 No. 40A 415V, 4P MCB of 10kA with 40A 4P Contactor &
2 Nos. 25A 415V, 4P MCB of 10kA .
Supply of following sizes of XLPE insulated Aluminum
conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV
2 grade cables conforming to relevant IS-7098 Code and
technical specifications
Say in lacs - 36.00
Digitally signed by JAYA
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT.pdf
Tender Document
GCC_2026.pdf
Tender Document
SCC.pdf
Tender Document
Integrity Pact.pdf
Tender Document
BoQ.pdf
Tender Document
Technical Specification.pdf
Tender Document
List of Approved Makes.pdf
Tender Document
TECHNICAL CIRCULAR.pdf
Tender Document
Milestone.pdf
Tender Document
Scope of work.pdf
Tender Document
Download all tender documents and submit your bid