Loading…
Loading…
Tender Value
₹2.0 Cr
EMD Value
₹2.5 L
Closing Date
20 Mar 2026, 11:00 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of [V/N or 'V' whichever is less; where V = Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Tenderer must have to submit valid Electrical Contractor license as per Indian Electricity Rules for the respective category of works issued by Government Electrical License Board on or before the closing date of tender. Copy of the electrical contractor license should be submitted along with the tender offer, otherwise, the tender will be summarily rejected.
The Similar nature of works for this instant tender shall be "Supply, installation, testing and commissioning of any LT/HT electrical work." The tenderer should have executed the similar nature of works in Central /State Government department or PSUs of Central /State Government."
50 conditions · 4 needing a document upload
Whether the cost of earnest money deposited
Migration to GST regime - Special Tender Conditions: The rates should clearly indicate the rate of applicable duties and taxes included in the prices quoted by them. Any variation in tax structure/ rate due to introduction of GST, shall be dealt with under Statutory Variation Clause. It should be ensure that bidders/tenderers are GST compliant and quoted tax structure/rates are as per GST Law.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor should submit the GSTIN number and same should be mentioned in the bills along with a copy of GSTIN registration certificate while submitting the bills to accounts for audit and payment, As GST is scheduled to implemented wef 01.07.2017. Without GSTN, no bill will be accepted w.e.f. 01.07.2017
From 01.07.2017 GST has been implemented but the detail guideline is still not clear. Hence, new tax structure on materials and labour will be applicable to both Railway & contractor after getting proper notification
Payment of Earnest Money deposit (EMD) , in respect of e- tendering,should be accepted through net banking or online payment gateway only
AT NGC: Electrical work in connection with augmentation of existing facilities for conversion into inspection bays for Electric Locomotives at New Guwahati Loco Shed.
EL-LM-25-26-42
EL-LM-25-26-42
Open
Works - General
120 Days
Hojai, Assam
₹0
₹2.5 L
20 Mar 2026
20 Feb 2026
6 Mar 2026
301 items across 9 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 80,21,333.09 | ||
| — | 35.00 | — | — | ||
| Supply, fitting, fixing and testing of integral industrial type high power 150W LED high bay light fittings with pressure die-cast aluminium housing with IP 65 protection complete with allaccessories. Lumens output should be of 130 Lumens/watt,LED driver's efficiency should be more than 85%, Power factorof complete fitting should be greater than 0.95, Inputoperating voltage: 140V to 277V AC. | — | — | — | 2,54,793.7 | |
| — | 80.00 | — | — | ||
| Supply,Installation,Testing & commissioning of 60W LED Street light fitting with hanging arrangement | — | — | — | 47,120 | |
| — | 150.00 | — | — | ||
| Supply, fixing, laying of 4x10 sq. mm copper flexible cable through shackle insulator hanging on GI angle as per requirement and as per direction of site Engineer in - charge of Railway. | — | — | — | 47,376 | |
| — | 600.00 | — | — | ||
| Supply, erection, testing &commissioning of GI perforated cable tray cover of size (100 x 25)mm of 16 SWG thickness with necessary GI coupler plate & hardware etc. as required in siteas per direction of site engineer of railway | — | — | — | 1,54,110 | |
| — | 1000.00 | — | — | ||
| Supply, erection of 40x6 mm GI strip for earth mat as per direction of site Engineer in-charge of Railway | — | — | — | 81,410 | |
| — | 60.00 | — | — | ||
| Supply, erection, commissioning of high speed air circulating wall bracket fan 600 mm sweep suitable for single phase 230 volt AC supply including fixing arrangement by allied engineering works( for supply of wall fan should be approved by Engineer at site before commissioning). | — | — | — | 2,23,836.6 | |
| — | 20.00 | — | — | ||
| Earthing complete with 50mm dia, 3.65mm thick , 4 mtr long GI pipe to be erected inside an earth pit of height 3.75 mtr& diameter 30 cm to be filled by alternate layers of salt (2) & charcoal (3) of width 50 cm each from the bottom and the rest by earth. Perforated holes of dia 12 mm each to be made in the pipe by drilling and a gap of 30 cm is to be maintained between the holes up to a height of 2.5 mtr from bottom. A second layer of perforated holes of same dimension are also to be made at an angle of 90o with the earlier layer of holes by keeping a vertical distance of 15 cm. A cement concrete chamber of size 30x30x30 cm and thickness 6 cm in ratio 1:3:6 by cement sand & 19mm and down stone chips is to be made around the pipe. The size of CC top cover is 24cmx24cmx4cm with provision of metallic folding handle is to be made. The cover to be provided on the 3mm top groove of earth pit (flash) as per direction of Railway Engineer. Earth continuity by 25x 5mm GI strip through alkathene pipe.75x16 mm GI nut, bolt and spring/flat washer has to be provided as per instruction of Railway Engineer. The connection of earth continuity wire with earth electrode to be made by GI soldering terminal socket of suitable size. The distance of earth electrode form building/other earthing system to be maintained by observing IE rules. GI pipe Make - TATA, BANSAL, JINDAL. This will supersedes the earlier drawing no. PCEE/ELG/DRG/2024/1 dated 30.09.24 & As Per Drg No: PCEE/ELG/DRG/2024/1/Rev-1 Dated 28.07.2025. | — | — | — | 32,196 | |
| — | 1000.00 | — | — | ||
| Dismantling of existing old Cable & wiring and otheraccessories without damage from the work site and handingover to concerned SSE office as per instruction of siteEngineer. | — | — | — | 8,280 | |
| — | 80.00 | — | — | ||
| Supply, installation, testing & commissioning of 32 A 4P MCB with industrial plug & socket of 32 A 5 Pin | — | — | — | 2,44,800 | |
| — | 50.00 | — | — | ||
| DESIGN SUPPLY AND COMMISSIONING OF OUTDOOR TYPE PRECOOLING PANEL MADE OUT OF 16SWG CRCA SHEET STEEL VERMIN AND DUST PROOF SIEMENS GREY POWDER COATED PAINT SUITABLE FOR WET LOCATIONS ENTRY FOR 120SQMM 4CORE LTUG CABLE LOCKING ARRANGEMENTS RYB INDICATION LAMPS(LED TYPE) SET ,SUITABLE COPPER BUS BARS COMPRISING OF 125A FP ADJUSTABLE THERMAL AND FIXED MAGNETIC SETTING MCCB 25KA 1 NO. AS INCOMER AND INDUSTRIAL TYPE 125A CAPACITY 3P+N+E SOCKET OF IP65 /67 RATED AS OUTGOING WITH PROPER FIXING AND LOCKING ARRANGEMENTS FOR CONNECTING PLUG INCLUDING PROPER GLANDS, LUGS, SLEEVES, TERMINALS AND PVC TROUGHS & ALL ACCESSORIES AS PER SITE CONDITION. NECESSARY FIXING ARRANGEMENTS ON THE WALL/ POLE/PILLAR AS PER SITE CONDITION COMPLETE. | — | — | — | 24,95,700 | |
| — | 78.00 | — | — | ||
| Supply and erection testing and commissioning of pole / under the Catwalks/ iron trust mounted Emergency feed terminal (EFT) including box with FRP base forbattery charging of 110V Train coaches with hinges type GI Box inpole clamped with nut & bolts etcas per RDSO's drawing No. SKEL3929 (110V) with latest amendments and as per direction at site Engineer | — | — | — | 31,086.9 | |
| — | 20.00 | — | — | ||
| "SUPPLY OF MATERIAL, INSTALLATION, TESTING & COMMISSIONING OF MULTICOLOR LED BASE NAME BOARD :(Technical specification / salient features for LED name board ) :- 1. Power supply System:- It should be as under. Input: 230 Volt single phase A.C ± 5% Output : 12 Volt D.C. 2. a) Letters for name board shall be made in three languages i.e. English, Hindi & REGIONAL LANGUAGE. . b) Substrate material used for the front portion of channel letter shall be 3 mm thick Acrylic sheet frosted or milk white (0/40). c) letter size should be as per board area and width of letter should be in proportionate to the height d) Depth of each letter should not be less than 3" e) Back of letter should be of sunpack sheet or 28 SWG powder coated sheet. f) Front & Back of letters should be assembled in such a fashion that it remains water tight, Dust proof. g) Front & Back of letters should be jointed / tighten with steel screw and washers, so that it may be opened in case of failure or for maintenance. h) All letters of each location should b fitted suitably on 3mm thick ALUMINUM PANEL Sheet and background shall be dark blue, if Required and this sheet to be fixed suitably on above M.S. Structure. i) Complete name board should be fixed on a M.S. Iron frame structure suitable size to withstand the atmospheric weather wind pressure etc. j)M.S. Structure should be grouted wel with appropriated cement, concrete mixture at given Location. | — | — | — | 22,812.8 | |
| — | 200.00 | — | — | ||
| Supply, fitting, fixing of 30Watt , LED flood light luminaries complete for pit lighting suitable for 110V DC input voltage. Fixture shall be made from pressure die cast aluminum housing with toughened glass cover, secured properly with Teflon gasket to ensure IP: 65 protections. System wattage shall be 30W max with system lumen output of 3000 lumens. LEDs shall be of SMD type (Cree/Nichia/Osram/Seoul). Luminaries and ballast shall be of same make. The LED fittings should be warranted for 5 years. | — | — | — | 6,72,288 | |
| — | 40.00 | — | — | ||
| Supply, installation, testing & commssioniong of 125 A 4P MCCB, 25KA Ics=100%Icu with adjustable thermal magnetic setting confirming to IEC 60947-2 with enclosure. | — | — | — | 7,35,000 | |
| — | 2050.00 | — | — | ||
| Supply and wiring of sub- main line concealed by 2x4 sq.mm. PVC insulated unsheathed and multi stranded FRLSCopper Cable confirming to IS 694/1990 through suitablesize of PVC conduit pipe with 1sq. mm unsheathed coppercable as earth continuity wire. | — | — | — | 1,57,891 | |
| — | 120.00 | — | — | ||
| Supply , laying and fixing of IP65 Loop in Loop out junction box with metric knockouts for cableentry, poly carbonate/thermoplastic junction box of size(155x210x92) mm suitable for16sq mm Aluminum wire along with proper arrangement for clamp, nut & bolts throughwall/ground/pole etc as per direction of site Engineer. | — | — | — | 2,91,759.6 | |
| — | 1.00 | — | — | ||
| Design, fabrication, supply, installation, testing and commissioning of LT control panel outdoor type of double door construction, FORM-3b as per IEC 60439-1 standards with IP 54/55 and 415 V 3phase &4 wire system, rear access type. The panel colour shall be RAL 7035 structured finish. cable entry incoming=bottom,outgoing=bottom.Horizontal busbar will be running at the top throughout the panel Enclosure shall be of CRCA steel sheet type. load bearing parts shall have 2mm thickness & non-loading parts shall have 1.6mm thickness. Gland plate shall be 3mm of GI type. the busbar system shall have heat shrinkable colored PVC sleeve. main busbar (power bus) is TPN electrolytic copper busbar size (50x6)mm. Doors and covers shall be gasketed by Neoprene gaskets. Control wires shall be 1.1KV grade Copper Flexible conductors. Panel should have short circuit strength at 100KA for 1 seconds as per IS:8623 part-I and temperature rise test at 6300 A as per IS:8623 part-1.The panel shall also consist of multifunction digital meter, CT, LED indicating lamps, auxiliary contractors, selector switches, cam switches etc as per manufacturer specification /recommendation & Cable alley also. the panel shall be provided with 3nos bus bar for phases made of electrolytic grade of copper bar of each (50x6) mm. the incoming switches shall beconnected with bus bar by crimping sockets on bus bar of panel side. the bar shall be connected by on either side by porcelain insulator and sufficient clearance shall be maintained inside the bus bar doe easy maintenance. Drawing would be submitted by the contractor and approved by competent authority. the panel has to built & inspected in OEM factory. inspection has to be carried out in presence of Rly's authorized representative. the control panel should be designed and manufactured by the CPRI and ISI.ISO approved manufacturer. The panel shall be fabricated from 2 mm thick consisting of (i) 630 A, 4P, 50 kA microprocessor based ACB , MDO version internal connection should be stranded suitable copper strip to be provided = 1 no. (ii) MCCB 400 Amps 4pole 50KA = 3 nos.(iii) MCCB 250 Amps 4pole 50KA Ics=100%Icu= 3 nos.. with adjustable thermal magnetic setting confirming to IEC 60947-2. | — | — | — | 6,82,775 | |
| — | 1.00 | — | — | ||
| Fabrication, design, supply, erection. testing & commissioning of floor mounted LT Main Control panel 8 way outdoor type MCCB consisting of (I) 400 AMP 4 pole MCCB, 50KA Ics = 01 no. II) 250 AMP 4 pole MCCB, 50KA Ics=100%Icu= 4 nos., III) 125 AMP 4 pole MCCB, 36 KA Ics=100%Icu = 4 nos. etc. - The panel shall fabricated from 2 mm thick sheet steel, powder coated, dust and vermin proof duly wired with PVC insulated copper wire confirming to IS: 694. The panel shall also comprise of suitable size & quantity of MCCB door interlocks, spreader link terminals, Aux contact, CT reverse current relay, led indicating lamps, 6A control MCB. The busbar shall be of electrolytic grade copper of size (50 x6) mm for 3 phase neutral. The panel to be manufactured by any CPRI approved. | — | — | — | 4,32,725 | |
| — | 2.00 | — | — | ||
| Supply installation testing &commissioning of constant voltage type battery charger having input 415 V (AC),output 110 - 155 V (DC),capacity 1x200 Amps (singlecircuit), Provided with Input/Output switches, DC & ACprotection fuses, Voltmeter,Ammeter, Fine-course voltage selection switches,Input MCCB, protection provision for short circuit,over voltage, high current,thermal failure, charge, trip indicator, reset switch withLED indications ofprotections & input R,V,Bphase etc. provided andenclosed in powder coatedsheet metal Box with wheelsfor easy movement. This should be got approved from the officer in charge beforeexecution. as per direction ofEngineer In Charge at site.The work to be executed asper direction of the engineerin charge at the site. If anyother items have be enomitted but are required forefficient working of thebattery charger it would bethe responsibility of the contractor to supply andprovide such items. However the quoted rate shall be inclusive of those items. | — | — | — | 4,53,282.78 | |
| — | 60.00 | — | — | ||
| Supply and wiring of 15/16 amp, 6 pin plug point for wiring of industrial fan through good quality hard PVC casing with associated accessories for surface type wiring by 4 mm sq single core PVC insulatedflexible copper cable with earth continuity by16 SWG bare copper wire and flush type15/16 amp controlling switch to be provided on hard plastic moulded board. Casing shallbe fixed on the wall / ceiling by MS (6x40mm) screw at an interval not more than300mm . | — | — | — | 17,932.8 | |
| — | 120.00 | — | — | ||
| Supply erection of reinforced cement concrete Cable Trench made of Cement Bricks with Cement plaster and the RCC Cover. The Cable trench should be in ratio 1:3:6 by cement,Sand and Ships of size 19 mm.including digging of pit to 500mm and MS rod of Suitable size asper instruction of Engineer incharge at site. | — | — | — | 1,20,464.4 | |
| — | 120.00 | — | — | ||
| Supply, laying, fitting, fixing of CI pipe 200 mm diameter heavy duty for protection of cable under track crossing/under the road etc . | — | — | — | 1,53,739.2 | |
| — | 300.00 | — | — | ||
| — | 300.00 | — | — | ||
| — | 100.00 | — | — | ||
| — | — | — | 41,200 | ||
| — | 300.00 | — | — | ||
| — | — | — | 1,04,097 | ||
| — | 500.00 | — | — | ||
| — | 20.00 | — | — | ||
| — | — | — | 32,455.8 | ||
| — | 3.00 | — | — | ||
| — | — | — | 2,628.51 | ||
| — | 100.00 | — | — | ||
| — | — | — | 12,179 | ||
| — | 1000.00 | — | — | ||
| Laying, commissioning of LT/HT cable XLPEinsulated power cables with armoured aluminum conductors of different sizes (4core 95 sqmm) partly along the pole andpartly through ground in cable trench.Loading, unloading & carrying of cable toactual work site by contractor own arrangement as per instruction of Engineer incharge at site. (Cable will be supplied by Railway.) | — | — | — | 40,930 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
EL-LM-25-26-42.pdf
ATTACHMENT
ModelsubstationguidelinesandRevisedearthingdrawing_compressed_compressed.pdf cege letter
ATTACHMENT
ModelsubstationguidelinesandRevisedearthingdrawing_compressed_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .