11 Sept 2023
Dismantling old plaster raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Demolishing R.C.C./PCC work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars.
Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead.
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
Barricading : Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube posts/horizontal members/bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. The work shall be executed as per drawing /direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineerin- Charge. (Note :- One time payment for brought/fabricated barricading at site shall be made , from start of work till completion of work i/c multiple shifting. The barricading provided shall remain to be the property of the contractor on completion of the work).
Bamboo's scaffolding: Providing and fixing bamboo scaffolding for repair works etc: all complete as directed.
Chipping the RCC surface and cleaning the rusted reinforcement and exposed surface by wire brush mechanical device or any other established method and applying rust removing solution of approved make and quality with cotton waste swab to reinforcement and allowing to dry the same for 24 hours, brushing of loose particle and applying first coat of Rust preventive coating of polymker and cement slurry in 1:1:5 proportion with soft brush without adding water including applying another coat of Rust preventing after 4 hours allowing air curing for 48 hours etc including scaffolding etc complete.
Providing and applying Bonding coat between concrete members like RCC slabs, columns, beams, Chajjas, pardis etc and cement mortar plaster using HACK AID PLAST of M/s. Sunanda Speciality Coatings Pvt. Ltd. or equivalent as per the instructions of manufacturer or Engineer Incharge; including cleaning the concrete surface thoroughly to remove dust, dirt, grime, deshuttering oils and rub down to a clean surface at all heights/ levels and locations and as directed by Engineer Incharge
Polymer Modified Morter ready mix including cleaning of surface with air mixed with water under pressure, and subsequent layer upto 10mm after hardening curing; all complete.(Polymer manufactured by Dr. Fixit, sunanda, pidilite, fosroc, acro- chem, build core or equivalent) Mortar shall be filled to bring to level with existing surface.
Providing and applying dash coat of Cement mortor (CM) 1:3 on the wall surface of average 20mm thick so as to keep the wall surface in line and level with adjacent RCC members including curing at all heights and locations etc. complete and as directed by Engineer Incharge.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Shuttering: Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Lintels, Piers, walls, Abutments, Posts and Struts
RCC/PCC 1:1.5:3 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Plaster: 20 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 8 mm thick cement plaster 1:4 (1 cement : 4 fine sand).
Granite cladding : 8mm to 12mm Granite stone of any colour and shade, tile work for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade. (mirror polished and machine cut edge). The rates are inclusive of niche, grooves, moulding as per design. payment shall be made on plan area irrespective of niche, grooves, moulding. Complete.
Granite coping : Providing and laying gang saw cut 30 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, wall coping and similar locations, laid over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge.
Vitrified wall tiles: Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, dado, walls, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 500x500 mm
External Waterproofing Paint :Providing and applying External Raincoat painting with crack filling Pidilite Company Product Dr.Fixit Rain Coat acrylic polymer based chemical compound coatig to the extrnal surface of walls to prevent water seepage in the masonry walls during monsoon added with required shade steiner to give required shade to the surface in two coats.Including providing three coats of priming of Dr.Fixit prime seal polymer base primer including preparing surface scrapping the existing loose old paint , removing loose particles of sand on the surface opening and cleaning the crack developed in the external plaster, removing loose partuicles by chiseling, filling cracks by chemical compound of Dr.fixit crack - X with proper penetration etc. Coating of Raincoat with the help of brush and as per instruction and specification given by pedilite and with instruction from Engineer in charge. Work shall be executed by certified applicator only covering guarantee of 3 years on court stamp paper of Rs 500 /-and necessary testing etc complete.
Zinc cromate primer: Applying priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works, to give an even shade one or more coats.
Synthetic enamal paint : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats.
Signage : Supply & Installation of Signage Boards like No Parking board, Prohibited place etc on MDL compound wall
MDL logo on Granite : Supply, engraving in Black Granite with golden colour finish and fixing on wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade. (mirror polished and machine cut edge engraving). Complete as directed and approved by EIC. Payment to be made on actual granite stone fixed on wall.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses, railing, walls etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes. The rates are inclusive of sharp points edges.
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Digital wall tiles : Providing and fixing Ist quality digital printed ceramic glazed wall tiles of approved MDL products like ships/Submarine/off shore platforms etc. conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Vertical Garden: Supply and installation of vertical garden including tree pots, pot tree, with irrigarion system on wall. Complete as directed by EIC.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved and Carriage of debris /Excavated materials from MDL Dockyard Premises to Navi Mumbai Municiple Dumping Ground
Supplying & erecting 12W LED (IP 65/IP 66) Waterproof Spike Light by making necessary arrangement/recess in wall to make it flush with surface Or as pre site requirement. Note: 1) System efficacy shall not be less than 90 lumens/watt. 2) CRI shall be more than 70. 3) Total harmonic distortion voltage and current shall be less than 10% 4) Operating voltage range shall be in range of 160V to 270V 5) Power Factor of Luminaire shall be more than 0.95 6) Luminaire shall conform to respective IS. 7) Luminaire shall withstand surge protection upto 3 kV. 8) Luminaire shall carry minimum three years warrantee. 9) Correlated Color Temperature (CCT) shall be required between 2700K-6500K. 10) There shall be provision for termination of earth connection
Supply and erecting Outdoor waterproof (IP65/IP66) Wall Washer Wall Light, Up/Down Beam Light 20W, (5 Up+5 Down) or similar as approved by the Customer. Making necessary arrangement/recess in wall to make it flush with surface Or as pre site requirement. Note: 1) System efficacy shall not be less than 90 lumens/watt. 2) CRI shall be more than 70. 3) Total harmonic distortion voltage and current shall be less than 10% 4) Operating voltage range shall be in range of 160V to 270V 5) Power Factor of Luminaire shall be more than 0.95 6) Luminaire shall conform to respective IS. 7) Luminaire shall withstand surge protection upto 3 kV. 8) Luminaire shall carry minimum three years warrantee. 9) Correlated Color Temperature (CCT) shall be required between 2700K-6500K. 10) There shall be provision for termination of earth connection
Supplying, erecting & marking DPMCB 6 A to 32 A B- series (for lighting) in provided distribution board as per specification no. SW-SWR/MCB Note:1)For lighting load 'B' series MCBs are to be provided and for motive power load 'C' series MCB s are to be provided 2)For heavy duty motors, welding transformers and machines having heavy surge current MCB of 'D' type series should be provided for which rates are to be taken by increasing 10% on the material cost of rates of 'C' series
Supplying, erecting & terminating XLPE armoured cable 2 core 2.5 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 3 core 4 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no.CB-LT/CU
Supplying and erecting triple pole and neutral distribution board (TPNDB) surface/ flush mounted suitable for SPMCB of 12 ways on iron / GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB Note:- 1) All MCB's shall have breaking capacity not less than 10 kA. 2) Above rates are applicable only to factory made enclosures. 3) Reduce overall rates by 5% if angle iron frame is not required. 4) MCB's (double pole, four pole or triple pole & neutral) & isolators for single phase circuits shall not be incorporated for outgoing circuits of three phase distribution board. 5) For more than 2 kW load RCCB shall invariably be provided & erected preferably on the same distribution board. (RCCB+MCB) or (RCCB+MCCB etc,) separate box for RCCB/ELCB is not permissible. 6) Above rates are for branded DB's with provision of same brand interior switchgears 7) The MCBDB is exclusive of incoming MCB/MCCB and outgoing SP/TP MCB's and the same should be preferably of the same make 8) ROHS compliant MCB's, MCCB's, RCCB's, RCBO's and Distribution Boards shall be preferred. 9) DB,s with IEC 61439 part 1 &3 and minimum IK 08 shall be preferred.
Supplying and erecting metal clad distribution board 240V, 8 way, 16A per way & neutral bar connector complete erected on iron / GI frame as per specification no. SW-SWR/MDB
Supplying, erecting & marking TPMCB 40A to 63A in provided distribution board as per specification No. SW-SWR/MCB Note:1)For lighting load 'B' series MCBs are to be provided and for motive power load 'C' series MCB s are to be provided 2)For heavy duty motors, welding transformers and machines having heavy surge current MCB of 'D' type series should be provided for which rates are to be taken by increasing 10% on the material cost of rates of 'C' series
Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification No. SW-SWR/MCB Note:1)For lighting load 'B' series MCBs are to be provided and for motive power load 'C' series MCB s are to be provided 2)For heavy duty motors, welding transformers and machines having heavy surge current MCB of 'D' type series should be provided for which rates are to be taken by increasing 10% on the material cost of rates of 'C' series
Providing and fixing sheet metal work in CRCA sheet with fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, rivetting etc. treated with anti-rust treament and duly power coated or painted with one coat of red lead paint and 2 coats of enamel paint as directed. Note:- For the purpose of panel boards above rates shall be inclusive of work along with angle iron work.
Providing & erecting Hot deeped Galvanised Perforated type Cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner. Note:- 1) Standard accessories shall typically include : a) 'Z' section support -30 x 35 mm in size - 312 mm in length - 6 nos. support for one piece ladder of 2.5 m in length each. b) Anchor fastner & nut bolts of adequate size - 16 nos.( 2 nos. per each support) c) Coupler plates with hardware - 70 x 200 x 3 mm thick - 2 nos. for each piece of 2.5 m Ladder complete with neccesory accessories such as Reducer, Horizontal Elbow & Tee, Up & Down Vertical Elbow & bend, Cross Piece complete erected in approved manner. 2) Provision for resting arrangement or support for perforated type Cable tray shall be made separetly as per iron work Item 3) Provision of cover for perforated type Cable tray shall be made only where it is absolutely necessary and make sure for locking arrangement. 4) Both type of cable tray shall be earthed properly.
Supplying & erecting H.M.S. P.V.C. conduit 20 mm. dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying & erecting water tight terminal box of cast iron of size 150 x 100 x 100 mm complete on pole as per specification no. CBSB
Supplying and erecting UPVC reinforced flexible conduit 20 mm in dia. conforming to I.S. and approved make with required number of couplings, PVC bushes, check nuts etc. complete.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx