Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAccepted-AOC | ₹27.7 L Quoted ₹27.9 L | L1 | Accepted-AOC BEING L1 AND REASONABLE |
| 2 | L2₹29.5 L+₹1.6 L (5.68%)Rejected-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | ₹29.5 L+₹1.6 L (5.68%) | L2 | Rejected-AOC NOT BEING L1 |
| 3 | L3₹31.9 L+₹4.0 L (14.3%)Rejected-AOC | ₹31.9 L+₹4.0 L (14.3%) | L3 | Rejected-AOC NOT BEING L1 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Documents not found in order |
Tender Value
₹31.3 L
EMD Value
₹62,600
Closing Date
28 Jan 2023, 6:00 pmClosed
GE E/M RR HOSPITAL
GE E/M RR HOSP DELHI CANTT-10
COMPREHENSIVE MAINTENANCE OF OT LIGHT, NURSE CALL SYSTEM AT AHRR AND UPS OF CTVS CENTRE AND ADC AND OTHER MISC WORKS UNDER GE E/M RR HOSP DELHI CANTT-10
2022_MES_565458_2
GE/H-32/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE E/M RR HOSP DELHI CANTT-10
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE E/M RR HOSPITAL
₹62,600
Yes
10 Mar 2023
7 Jan 2023
30 Jan 2023
7 Jan 2023
28 Jan 2023
14 Jan 2023
Amount
Comprehensive Maintenance of Wired/Wireless multi services Nurse Call System and patient call system installed at AHRR,of following location, employing 01 technician having qualification of ITI in electrical/electronics engineering with adequate experience in the general shift from 0900 hrs to 1700 hrs including Sunday and holiday to make the system functional in following wards :- (i) Main Bldg AHRR- 597 Nos bed unit and 24 Nos display (ii) CTVS Centre - 257 Nos bed unit and 12 Nos display (iii) ADC - 8 nos Display unit of patient call system Notes : (i) Preventive & routine repair/maintenance of Wireless Display and controlling units. (ii) Preventive & routine repair/maintenance of Wireless Bed Units (iii) Preventive & routine repair/maintenance of DC 12V batteries for Bed Units (iv) Preventive repair & Maintenance of all systems on monthly basis and upkeep of log book. (v) Attending to all complaints within 24 hours failling which penal recovery @ Rs 500.00 /complaint per day will be effected from contractor's dues (vi) Field Service Reports will be maintained and submitted to the concerned JE(MES) whenever required. (vii) All spares parts included in quoted rates excluding wireless bed unit and wireless display and controlling unit. (viii) The complete work is to be carried out through the OEM & MOU from the companies must be submitted before commencement of work.
Comprehensive.preventive and periodical maintenance and checking serviceability of on line UPS installed in various switch rooms/Wards/Dept of CTVS Centre and Army Dental Centre as per manufacturer's recommendation in reliable safe and efficient manner using latest technique & expert consultancy by regularly examining and adjusting the mechanical & electrical driving equipment including replacement of defective /spare parts/items as and when required by employing 01 technician having qualification of ITI or diploma in electrical/ electronics engineering with adequate experience in the general shift from 0900 hrs to 1700 hrs including Sunday and holiday complete all as directed to entire satisfction of Engineer-in-charge. (i) 20 KVA UPS -05 Nos (Sinetrac/ lebotek) (ii) 30 KVA UPS - 12 Nos ( Luminious) Notes : (i) The cost of all defective /userviceable spare parts/items required to be replaced is deemed to be included in the rate quoted by contractor excluding battery and Transformer. (ii) Cost of any item and extra manpower required to make the system functional is deemed to be included in the rate quoted by the contracor. (iii) The contractor shall attend the complaints of UPS on receipt at any time round the clock including Sunday and Holiday and the cost of the same is deemed to be included in the rates quoted. The penalty for non attending the complaints of UPS upto six hrs shall be Rs. Rs.1000/- per day. (iv) Maint/ repair as enumerated above shall be under taken by the manufacturer or their authorized dealer/ rep. (v) The dust cleaning shall be carried out of each UPS in a week. (vi) The elect connections shall be checked regularly for looseness / tightening the same. (vii) The fortnightly periodical maint shall be carried out in rotation apart from breakdown for each UPS and record of same to be maintained duly signed by contractor rep and MES rep. (viii) The complete work is to be carried out through the OEM & MOU from the companies must be submitted before commencement of work. (ix) Rate quoted by contractor for this item does not include replacement of battery and main transformer .
Comprehensive, preventive and periodical maintenance of OT Lights (21 Nos) of installed at OT Complex of main bldg of AHRR, CTVS Centre and Army Dental Centre as per manufacture recommendation, in reliable, safe and efficient manner using latest techniques & expertise consultancy by o1 technician having qualification of ITI in electrica//electronics in general shift from 0900h to 1700h including sunday and holiday, and adjusting the mechanical and electrical driving equipment incl replacement of minor defective / spares parts/items i.e. lamp including complete accessories likes driver, ballast etc and wire, lugs, nut, bolts, screws etc as and when required, complete all as directed to entire satisfaction of Engr-in-charge. (i) Main Bldg Hospital(P-100) - 09 Nos (Dragger, Philips) (ii) CTVS Centre - 07 Nos ( Philips) (iii) Army Dental Centre - 05 Nos (Phillips) Note : (i) The cost of all kind of minor spares parts/items i.e. nut, bolt, washer, fastner etc is deemed to be included in the quoted rates. (ii) The cost of transportation (to and fro), skilled manpoer and other necessary equipment shall be arranged / brought by contractor to complete the job at site only and no extra cost shall be paid to the contractor in this effect. (iii) The complete work is to be carried out through the OEM & MOU from the companies must be submitted before commencement of work. (v) The penalty for non attending the complaints upto six hrs shall be Rs. 500/-, per day.
Supply and installation including testing and commissioning of SMF Battery 12 Volts, 26 AH with battery copper terminals/thimples, battery inter-connection copper cable 16 Sqmm etc, complete all as directed. Note:- Minimum Replacement manufacture warranty for 2 years.
All as per srl item No 4 here-in- before but SMF battery 42 AH
All as per srl item No 4 here-in- before but SMF battery 65 AH
Supply and fix in replacement and testing commissioning of wireless mltiservice for three service call ( Nurse Calling, House Keeping and Code Blue) Bed unit and reset with wireless door indicator, with built-in RFAF, environment condition, operating temp 0 degree centigrade-50 degree centrigade( 32 degree F - 122 degree F) operating voltage humidity 10%-90% without congealment power requirement, operating voltage 12 Voltage battery opearing current -standby< 10 mA, working status < 10 mA packing contents wireless bed unit button with handset DC 12V battry screws and mounting plate including fixing accessories, complete all as directed.
Supply and fix in replacement and testing commissioning of wireless display unit with human voice address and built-in RFAF frequency attention filter , having the following specification complete all as directed :- (i) Capacity : Max 50 beds, 7 seg LED display max, 2 digit for one bed receiving 3 LED indicators ( Nurse Calling, House Keeping and Code Blue) (ii) Power reqirement : AC 230 V, 5Amps, 50 Hz (iii) Operating Temp : 0 to 50 degree ( 32 degree F - 122 dgreeF) (iv) Operating Humidity: 10%-90% without congealment (v) Operating Voltage : 05 volt DC-12 volt DC (vi) Operating current : 200mA, Standy<30mA, Full load<35mA (vii) Startup current : 600 mA (viii) Speaker : Full duplex (ix) Impedence : 8C + 15% (x) Max outout Power : 0.5 W (xi) Distribution Rate : 5% Max (xii) Max dB : 89 + 3dB (xiii) Frequency Range : 50 Hz to 10 KHz
Supply and fix in repair wired multi service Handset with 2 metre long for three service calling (Nurse Calling, House Keeping and Code Blue) and reset facility and door Indicator, complete all as specified and directed by Engineer-in-charge.
Supply and fix in repairs UPS transformer copper wound suitable for UPS for 20 KVA ( 3 phase input and 1 phase output) includidng testing complete all as specified and directed by Engineer-in-charge.
Supply and fix in repairs UPS transformer copper wound suitable for UPS for 30 KVA ( 3 phase input and 1 phase output) includidng testing complete all as specified and directed by Engineer-in-charge.
RUCHIKA ENGG.WORKS
ACR ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .