- Rajesh Rathor(DFLT)
MUNICIPAL CORPORATION, RAIPUR
हीरापुर जरवाय ई-बस डिपों में सब स्टेशन (उपकेन्द्र) निर्माण कार्य बाबत्।
190883
NIT NO:75/RDUPSS/2026 RAIPUR DATED: 13.05.2026
RESTRICTED TENDER
WORKS
MIXED PERENTAGE ITEM RATE
MUNICIPAL CORPORATION
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
13 documents required · 13 mandatory
Urban Administration and Development Department (UADD)
WORKS
- Rajesh Rathor(DFLT)
RESTRICTED TENDER
MIXED PERENTAGE ITEM RATE
A B
MUNICIPAL CORPORATION, RAIPUR
TENDER SECTION
COMMISSINOR, MUNICIPAL CORPORATION, RAIPUR
120.00
No
1
190883
29 May, 2026 5:30:00 PM IST
3 Jun, 2026 12:30:00 PM IST
13 May, 2026 6:30:00 PM IST
NIT NO:75/RDUPSS/2026 RAIPUR DATED: 13.05.2026
हीरापुर जरवाय ई-बस डिपों में सब स्टेशन (उपकेन्द्र) निर्माण कार्य बाबत्।
143000.00 INR
Fixed Deposit Receipt (OFFLINE)
2
1 Jun, 2026 5:30:00 PM IST
28243599.27
AS PER NIT
AS PER NIT
AS PER NIT
12
0.00 INR
13 documents required · 8 mandatory · 5 optional
₹0
₹1.4 L
29 May 2026
13 May 2026
3 Jun 2026
13 May 2026
1 Jun 2026
Sr. No Items Approved Makes
1 Distribution Transformer TESLA/VIJAY/VOLT AMP/KIRLOSKAR/APPROVED VENDER OF CSPDCL
2 Timers L&T/SCHNEIDER/LEGRAND/SIEMENS
3 ACB L&T/SCHNEIDER/SIEMENS/ABB/C&S
4 CHANGE OVER SWITCH
i ON LOAD GE/L&T/C&S/ABB
II OFF LOAD STANDARD/C&S/ABB/L&T
5 VOLT METER,AMPERE METER
I ANALOG TYPE MECON/ESSVEE/AE
II DIGITAL TYPE MECON/ESSVEE/AE/C&S
6 CURRENT TRANSFORMER C&S/AE/KAPPA
7 SELECTOR SWITCH GE/L&T/C&S/ABB/SIEMENS
8 STATIC WATT HOUR METER L&T/SEMS/GENIUS/APPROVED VENDOR OF CSPDCL
9 STARTER/CONTACTORS GE/L&T/SCHNIEDER
10 RELAY SIEMENS/ABB/SCHNEIDER
11 MCCB L&T/ABB/SCHNEIDER/LEGRAND/C&S
12 CONNECTORS ELMEX/CONNECTWELL/RAYCHEM/
13 MCB/RCCB/DBs L&T/ABB/SCHNEIDER/LEGRAND/C&S
14 WIRES FINOLEX/POLYCAB/RR KABEL/GLOSTER/HAVELLS
15 LT CABLES FINOLEX/POLYCAB/GLOSTER/HAVELLS/RAVIN/CCI/ UNIVERSAL
16 BRASS GLAND COMET/METAL CRAFT INDUSTRIES/RAYCHAM
17 ALUMINIUM LUG DOWELLS/METAL CRAFT INDUSTRIES/RAYCHAM
18 HT CABLES UNIVERSAL/GLOSTER/CCI/POLYCAB/RAVIN
19 CABLE JOINTS DENSON/RAYCHEM/3-M
20 MS CABLE TRAY VENUS/PASCO/DOLPHIN/METALEM/ASIAN ANCILLARIES
21 COPPER BUS TRUNKING ARRANGEMENT L&T/SCHNEIDER/LEGRAND/L&S
22 RING MAIN UNIT CROMPTON/SIEMENS/ABB/SCHNEIDER/LUCY
OFFICE OF THE MUNCIPAL CORPORATION, RAIPUR(C.G.)
Name of Work :- Construction of 33 KVA/0.415 sub station with 3x 2000 KVA 33/0.415KV transformer for e-Bus seva at City Bus Depot JARWAY for 100 buses charging
As per SOR:Schedule of rates public works department Electrical & Mechanical 01.06.2020 -https://pwd.cg.nic.in/CurrentEvents/E&MSOR_01_06_2020.pdf
As per SOR:Schedule of rates DSR 2018
As per SOR:Schedule of rates CSPDCL 2024 https://cspdcl.co.in/cseb/Files/SOR/SoR%20for%20FY%202024-25/Schedule_A_of_SOR_2024-25__09May2024.xlsx
S. N. SOR Description of Items Qty. Unit Rate Amount
1 TRANSFORMER AND RMU:
1 NON SOR Miscellaneous charges for Electrical Permissions & form 68 fees 1 Job
Total Miscellaneous work
OFFICE OF THE MUNCIPAL CORPORATION, RAIPUR(C.G.)
Name of Work :- Construction of 33 KVA/0.415 sub station with 3x 2000 KVA 33/0.415KV transformer for e-Bus seva at City Bus Depot JARWAY for 100 buses charging
As per SOR:Schedule of rates public works department Electrical & Mechanical 01.06.2020 -https://pwd.cg.nic.in/CurrentEvents/E&MSOR_01_06_2020.pdf
As per SOR:Schedule of rates DSR 2018
As per SOR:Schedule of rates CSPDCL 2024 https://cspdcl.co.in/cseb/Files/SOR/SoR%20for%20FY%202024-25/Schedule_A_of_SOR_2024-25__09May2024.xlsx
S. N. SOR Description of Items Qty. Unit Rate Amount
1 TRANSFORMER AND RMU:
A PWD E SOR 2020, 21.2.7 Supplying and installation of outdoor type Transformer ONAN type with copper winding having following continuous KVA rating, 33 /0.415 KV 3 Phase 50 Hz Vector group DYn-11, (Online tap changer) tapings in steps of ± 2.5%, ± 5%, --7.5% with oil conservator, silica gel breather having connecting terminals on HV side suitable for bare conductor/HT cable connection, cable end box on medium voltage side suitable for 1.1 KV single / 3½ core cable(upto 300 sq mm)/bus ducting arrangment and confirming to IS:1180 Part-2 Level 3 on existing Brick /CC/RCC platform with all fittings, accessories, filled with filtered transformer oil including testing and commissioning etc. complete as per specification 2000 KVA 3 EACH
B PWD E SOR 2020, 8.12 Supply, installation, testing and commissioning of 33 KV ring mains unit with 2 LBS (load break switch) & 2 VCB 25 kA for 1 Sec. 630 A outdoor (IP 54); rated voltage 36 KV, safeplus safepro: 36 KV extensible outdoor safeplus manual. Metal enclosed switchgear: IEC 62271-200; general purpose switches : IEC 60265-1; disconnectors and earthing switches: IEC 62271-102; switch fuse combination: IEC 62271-105 common clauses : IEC 60694; pressure of SF6 gas : 1.4 bar at 20 deg C.; cable bushing outside cone; CENELEC IN 50181 interface C temp. class; -25 deg. C to ± 40 deg. C indoor; Degree of protection: - SF6 tank: IP 67 - Fusecanisters : IP 67 - Front Cover: IP 2X - Cable Cover: IP 3X - Enclosure : IP 54 Busbars : 306 sq mm copper; earthbar (external): 120 sq mm copper; bolt dimention: M10; thickness of stainless steel tank: 2.0 mm; Covers; - Front cover: RAL 7065; - Side and cable cover : RAL 7035 - Electrical data & dash; 36 KV - Each terminal voltage : 33 KV; rated frequency: 50 Hz; rated current for busbar : 630 A; 1 SET.
Rated current for cable switch disconnector : 630 A; short time with stand current (3 sec.) Cable switch disconnector : 20 kA rms; Rated current for Transformer T-off: 200/630 A; Short time with stand current (3 sec.) V-module vacuum circuit breaker 20 kA rms: Impluse With stand voltage. To earth and between phases: 170 KV insulation level : power frequency 1 min. : 70 KV, including all accessories, terminal kits etc. as complete required.
C PWD E SOR 2020, 8.11 Supply, installation, testing and commissioning of 33 KV ring mains unit with 2 LBS (load break switch) & 1 VCB 25 kA for 1 Sec. 630 A outdoor (IP 54); rated voltage 36 KV, safeplus safepro: 36 KV extensible outdoor safeplus manual. Metal enclosed switchgear: IEC 62271-200; general purpose switches : IEC 60265-1; disconnectors and earthing switches: IEC 62271-102; switch fuse combination: IEC 62271-105 common clauses : IEC 60694; pressure of SF6 gas : 1.4 bar at 20 deg C.; cable bushing outside cone; CENELEC IN 50181 interface C temp. class; -25 deg. C to ± 40 deg. C indoor; Degree of protection: - SF6 tank: IP 67 - Fusecanisters : IP 67 - Front Cover: IP 2X - Cable Cover: IP 3X - Enclosure : IP 54 Busbars : 306 sq mm copper; earthbar (external): 120 sq mm copper; bolt dimention: M10; thickness of stainless steel tank: 2.0 mm; Covers; - Front cover: RAL 7065; - Side and cable cover : RAL 7035 - Electrical data & dash; 36 KV - Each terminal voltage : 33 KV; rated frequency: 50 Hz; rated current for busbar : 630 A; 1 SET.
Rated current for cable switch disconnector : 630 A; short time with stand current (3 sec.) Cable switch disconnector : 20 kA rms; Rated current for Transformer T-off: 200/630 A; Short time with stand current (3 sec.) V-module vacuum circuit breaker 20 kA rms: Impluse With stand voltage. To earth and between phases: 170 KV insulation level : power frequency 1 min. : 70 KV, including all accessories, terminal kits etc. complete as required.
Total Transformer & RMU Electrical Work(1)
A PWD E SOR 2020, 17.1.8 Supplying and laying one number following sizes XLPE, steel armoured, aluminium conductor power cable of 33 KV grade direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as per specification and IS: 7098 (2011, Part 2).3 x 300 sq mm 150 Rmt.
B PWD E SOR 2020, 17.2.8 Supplying and laying following sizes additional one number XLPE, steel armoured, aluminium conductor power cable of 33 KV grade direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as per specification and IS: 7098 (2011, Part 2)..3 x 300 sq mm 150 Rmt.
C PWD E SOR 2020, 17.5.8 Supplying and laying following sizes one number, steel armoured, copper conductor XLPE power cable of 33 KV grade on surface/ existing cable tray with M.S flat clamp and steel dash fastener/ G.I. bolts and nuts as per specification and IS: 7098 (2011, Part 2)..3 x 300 sq mm 175 Rmt.
D PWD E SOR 2020, 17.11.8 Supplying and making INDOOR cable end jointing with heat shrinkable cable jointing kit including lugs and other jointing materials, for following size of 3 core, XLPE aluminum conductor cable of 33 KV grade as per specification. :300 sq. mm 7 Nos.
E PWD E SOR 2020, 17.12.8 Supplying and making OUTDOOR cable end jointing with heat shrinkable cable jointing kit including lugs and other jointing materials, for following size of 3 core, XLPE aluminum conductor cable of 33 KV grade as per specification. :300 sq. mm 11 Nos.
F PWD E SOR 2020, 8.9.10 Supplying, installing by suspension on ceiling, testing and commissioning of following capacity COMPACT SANDWICH TYPE BUS TRUNKING for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating (as per IS: 2147, and IS: 8623) after fixing the tap off boxes and all accessories, made of 2 mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium busbars having current density of 130 of A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as per specification:3200 amps 50KA SC for 1 sec 45 Rmt.
Total Cable Electrical Work (2)
A DSR 2018, 5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 6 SET
A DSR 2018, 5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 20 SET
B DSR 2018, 5.20 Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. 90 Meters
C DSR 2018, 5.15 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 400 Meters
Total Earthing Electrical Work (3)
4.1 MAIN LT PANEL WITH 3 NO 3200A ACB AS INCOMER ,2 NO 3200A ACB BUS COPLER WITH 5 NO VAF METER HAVING EACH TRANSFORMER 8 NO 630A MCCB + 8 NO AMP METER AS OUTGOING
A PWD E SOR 2020, 7.19.6 Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification.1200 mm deep 22 SQM
B PWD E SOR 2020, 7.20.13 Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) aluminium bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification.3200 amp (4X100x10mm) 22 Meters 572 600
C PWD E SOR 2020, 7.20.7 Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) aluminium bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification.800 amp (100x6mm) 24 Meters 28
D PWD E SOR 2020, 10.2.5 Providing and fixing approved make, Electrically Operated, draw out type, 415/500 volts, 4 pole air circuit breaker complete with all standard accessories as per manufacturers specifications including drilling holes on the board, connections, earthing the body, testing and commissioning etc. as per specification and Ics = Icu = Icw for 1 second, IS/IEC: 60898.3200 amps, 4 pole, 65 KA 3 Each 23.72881356 6.73 16.99881356
E PWD E SOR 2020, 10.1.11 Providing and fixing approved make, Manually Operated, draw out type, 415/500 volts, air circuit breaker complete with all standard accessories as per manufacturers specifications including drilling holes on the board, connections, earthing the body, testing and commissioning etc. as required, Ics = Icu = Icw for 1 second, IS/IEC: 60898.3200 amps, 4 pole, 65 KA 2 Each
F PWD E SOR 2020, 10.15 Providing and fixing following rating current transformer in existing cubical panel including, connections, testing and commissioning etc. as per specification. Each
10.15.8 800/5 amps 72 Each
G PWD E SOR 2020, 10.18 Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as per specification. 48 Each
H PWD E SOR 2020, 10.19 Providing and fixing penal mounting digital type ammeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification 24 Each
I PWD E SOR 2020, 10.23 Providing and fixing panel mounting digital type VAF (Volt-amp-frequency combined) Multi Function meter of size 100x100 (NS) in existing cubical panel including connection, testing and commissioning etc. as per specification. 5 Each
J PWD E SOR 2020, 9.1.52 Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu.4 pole MCCB, 630A, Adjustable Microprocessor Release, 50KA 24 Each
Total LT Panel Electrical Work (4)
5 CSPDCL SOR Double Pole Structure
New SAP Bin Code 33 KV Double POLE STRUCTURE ON H-BEAM POLE
1 7130601958 H-Beams 152 X 152 mm., 37.1 Kg/Mtr 13 Mtr. Long (482.3 Kg x 2 No = 964.6 Kgs) 964.6 Kg
2 7130810608 D.C.cross- arm of 100 X 50 X 6 mm. suitable for 5' centre DP 1 Set
3 7131930415 33 kV DO Fuse unit 3 Each
4 7130820248 33 KV Strain H.W. fitting 6 No
5 7130820013 33 KV Polymer Disc Insulator 6 No
6 7130830063 DOG ACSR Conductor (100 Sqmm, Al. Eq) with 3% sag 100 Mtr
7 7130820009 33 kV Polymeric Pin insulator with Pin 3 No.
8 7130810006 DC cross arm 3.8 Mtr. Channel of 100x50 mm 4 Set
9 7130810193 (i) Stay Clamp For PCC Pole 16 Pair
7130810692 Horizontal & cross bracing 5' centre with set of 4 back clamps (ii) Stay Clamp For "H" Beam 4 Pair
7130600032 (iii) M.S.Angle 65X65x6 mm 60 Kg
10 7130840021 33 kV Porcelain Lightning Arrestors 3 Each
11 7131930321 33 KV AB Switch 1 Each
12 7130860033 (i) Stay set 20 mm 6 No
7130810692 (iii) Stay Clamp for "H" Beam 6 Pair
7130860076 (iv) Stay Wire 7/8 SWG @ 8.5 kg Per Pole 51 Kg
13 7130200202 Concreting of supports @ 0.6 Cmt. Per pole for H-Beam and @ 0.05 Cmt per pole for base padding for H-Beam pole (1:3:6) 3.1 Cmt.
14 7130810624 Strain Plate (65x8 mm) for 33 Kv 6 No
15 7130870013 Earthing Set (Coil earth as per Drg. No. g/007) 2 No
16 7130211158 Red oxide paint 2 Ltr
17 7130210809 Aluminium paint 2 Ltr
18 7130610206 Barbed Wire (@ 2 Kg/Pole) 4 Kg
19 7130880041 Danger Board 1 No
20 7130810624 Strain Plate (65x8) mm 6 No
21 M.S.Nuts and Bolts Kg
22 SUB TOTAL-1 (Material cost including GST)
23 Material cost excluding GST (Sub Total-1/1.18)
24 Incidental Charges @ 7.5% on Serial no. 23 : -
25 Labour charges for concreting of H-Beam Pole 2.6 Cmt
26 Labour charges as per Schedule No.- AL-2(A)
27 Transportation charges of all line materials :-
(i) Upto 100 km @ 2% on Serial no. 22 0.02
28 Overhead Charges @ 12.5% [Market Fluctuation, Service Tax, Contractor's profit etc.] on Serial no. - 23, 24, 25, 26, 27(i)
29 Total Estimated Cost excluding GST [Serial No. 23, 24, 25, 26, 27(i), 28]
30 Total Estimated Cost excluding GST (Rounded off)
33 KV Double POLE STRUCTURE ON H-BEAM POLE WITH ALL ABOVE MATERIALS 2 SET
Total Double Pole Structure Electrical Work(5)
A PWD E SOR 2020, 30.13 Providing and laying Cast-in-situ cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm including mixing with mechanical mixer, compacting with vibrator, finishing and currying etc. complete but excluding form work. 32 Cum
B PWD E SOR 2020, 21.8 Supplying and erecting chain link mesh fencing for electric sub-station switch yard of 2.5 m approx. height from ground level using angle iron size 50 X 50 X 6 mm erected in C.C. foundation 15 X 15 X 40 cm deep at every 2 metre fitted with flat iron support of size 25 X 6 mm on top, bottom and mid way and chain link mesh 50 x 50 mm aparture and 4 mm dia G.I. hard wire securing and screwing with 2mm dia G.I. wire, G.I. staples, G.I.U-nails or steel pins to the angle iron at every distance of 30 cms, by iron studs complete duly painted with one coats of red oxide and two coats of approved colour paint. (Area of fencing i.e. height x length is to be measured) 1200 sqm
C PWD E SOR 2020, 21.9 Supplying and erecting MS gate of approx. size 3.0 m (W) x 2.0 m (H) in two laps for electric sub-station switch yard fencing frame made of angle iron size 50 X 50 X 6 mm on top bottom and sides fitted with flat iron support of size 25 X 6 mm on mid way horizontaly and square bar of size 8 mm at every 100mm vertically including 3 sets of heavy duty MS hinges and aldrop complete duly painted with one coats of red oxide and two coats of approved colour paint. 18 sqm
H PWD E SOR 2020, 15.30 Designing & Providing of suitable RCC trench in cement concrete 1:3:6 (1 Cement : 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) for laying of cable inground including execavation, steel reinforcement (minimum 35.75 kg per cum), 4" drain wall, drain cover, frame work, curing & refilling of excavated soil etc as per specification. 150 Cum
Total civil work ( 6)
boq_comp_chart.xls
BOQ Comparative Chart • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.10 MB
2017872557364201883_188828_Form B.pdf
NIT • 0.17 MB
4748242553211427517_188828_Affidavit format.pdf
NIT • 0.06 MB
5571573511460810365_188828_Niyam shart.docx
NIT • 0.02 MB
6641484958283162582_188828_FORM A.pdf
NIT • 0.19 MB
5177387111991073312_190883_NIT Details.doc
NIT • 0.08 MB
3187713739619619973_188828_E bus.xlsx
BOQ • 0.01 MB
3657137398931787045_188828_BOQ BUS DEPOT NON SOR.xlsx
BOQ • 0.14 MB
5146175909309461759_188828_BOQ BUS DEPOT SOR.xlsx
BOQ • 0.15 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .