| 1 | L1₹42.3 LAccepted-AOC DOOR NO 43 2 BESIDES VIZAG DEFENCE ACADEMY 104 AREA KAPPARADA VISAKHAPATNAM 530013 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530013 | L1 | Accepted-AOC L1 | |
| 2 | L2₹45.4 L+₹1.5 L (3.51%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹50.0 L+₹6.2 L (14.1%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹51.6 L+₹7.7 L (17.5%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
12 Jul 2021, 6:00 pmClosed
GE (AF) Hakimpet
GE (AF) Hakimpet, Secunderabad-14
SPECIAL REPAIRS TO INTERNAL WIRING OF P-65, 66, 72 AND 73 AT OMQs ALONGWITH CONSIDERING OF MAP AUTHORISATION AND SECURITY LIGHT INFRASTRUCTURE FROM ISKARA GAE TO DUTY CREW ROOM AND PROVN OF EXHAUST FANS FOR CERTAIN OTM BUILDIGS IN TECH AREA AT AFS
2021_MES_451400_1
8310/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
HAKIMPET
As per NIT
6 documents required · 6 mandatory
₹500
GE (AF) HAKIMPET
₹96,000
Yes
9 Sept 2021
14 Jun 2021
14 Jul 2021
14 Jun 2021
12 Jul 2021
28 Jun 2021
Amount
Disconnecting the elcetric supply, dismantling and taking down the distribution board any type alongwith all inner components like MCBs/ Isolators of any capacity and making good the disturbed surfaces complete all as specified and directed.
Supply and fix MCB distribution board single door type, SPN 12 way, 240 Volts sheet steel powder painted IP 43 protection with bus bar, neutral link & earth bar etc. for incoming RCBO and outgoing MCBs complete all as specified and directed.
Supply and fix MCB distribution board single door type, SPN 8 way, 240 Volts sheet steel powder painted IP 43 protection with bus bar, neutral link & earth bar etc. Complete all as specified and directed
Supply and fixing MCB SPN Ç'curve 240/415 volts ISI marked tested at CPRI breaking capacity of 10 KA , 63 Amps capacity, complete all as specified and directed.
Supply and fixing MCB SPN Ç'curve 240/415 volts ISI marked tested at CPRI breaking capacity of 10 KA , 40 Amps capacity, complete all as specified and directed.
Supply and fix MCB, SP, 'C' curve, 6 - 32 Amps, 10 kA ISI marked suitable for 415/240 volts operation, tested at CPRI , complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
M&L for point wiring with single core PVC insulated FRLS unsheathed, 1100 volt grade cable with multi strand copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic PVC casing & caping , medium grade, as directed/ ground requirement, ISI marked of suitable size, surface on wall, ceiling with GI screws, rawl plugs with all fittings including Tee, Junction boxes and provision of pressed steel terminal box powder coated or PVC Box of suitable size with 3 mm thick laminated or PVC sheet cover for mounting switch sockets and regulators and drawing continuous earth wire of PVC insulated FRLS unsheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) complete all as specified and directed. Note :-Making good the disturbed surface and matching with the existing surface with the help of Distempering and other items. Rate of the cost of making goods deemed to be included in the unit quoted rate.
One light /exhaust fan/bell point /Ceiling fan controlled by one way switch.
One 3 pin 5 Amps socket point controlled by one switch on same board.
One 3 pin 5 Amps socket point controlled by one switch on independent board.
M&L for point wiring with 1.5 sq.mm FRLS insulated multistranded copper conductor ,1100 volts grade single core PVC insulated and unsheathed cable drawn through existing concealed PVC conduit all as per site requirement including FRLS,PVC insulated and unsheathed cable with copper conductor cable of size 1.50 sqmm as earth conductor as per proper colour coding and pressed steel terminal boxes made out of 1.6 mm thick MS sheet box, 60mm deep covered with 3mm thick laminated hylam sheet fixed with cadmium plated screws for mounting switches,sockets,fan regulator, etc including making good the disturbed surfaces of walls and paint tuch up to match with the existing surfaces as per site requirement complete all as specified and directed by Engineer-in-Charge. Note :-Making good the disturbed surface and matching with the existing surface with the help of distempering and other items. Rate of the cost of making goods deemed to be included in the unit quoted rate.
One light /bell /Exhaust fan/Fan Point controlled by one switch
One 3 pin 6 Amps socket point controlled by one switch on same board
One 3 pin 6 Amps socket point controlled by one switch on independent board
All as per ser item No. 9 here-in-before but for one 15/16 Amps switch socket combination on independent board with 2.5 sqmm cables for phase and neutral and 2.5 sqmm cable green in colour as earth continuity conductor. complete all as specified and directed.
Supply and fix switch piano flush type 5 Amps, one way complete all as specified and directed.
S&F bell push,flush type, 6 Amps ,240 Volts ISI marked complete all as specified and directed.
Supply and fix Switch socket combination 2 in 1, 3 pin, 5 Amps flush type universal complete all as specified and directed.
Supply & Fix stepped type electronic fan regulator flush type complete all as specified and directed.
Supply and fixing of Bell multi music type complete all as specified and directed.
Supply and fix Lamp holder, PVC/Polycarbonate type with back plate suitable for LED batten fittings complete all as specified and directed.
Supply and fix Ceiling rose, 3 terminal, PVC/ polycarbonate insulated body complete all as specified and directed.
Supply and fix Switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type universal complete all as specified and directed.
Supply and fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps.complete all as specified and directed.
Supply and fix LED lamp LED GLO 15 watt complete all as specified and directed.
Supply & fixing wall mounted LED batten, with extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver for 10W LED (2ft) complete with all accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge. Make:-Havells /Philips/CG.
Supply & fixing wall mounted LED batten fittings with extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver for 22W/20W/18W LED (4ft) complete with all accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge. Make:-Havells / Philips/CG.
Refixing the 20 watt and 10 watt LED fittings and fixtures the same after rewiring on the place with necessary wire all as specified and directed by Engr - In - Charge.
Supply and fixing LED security light fittings 25 watt capacity as building light with and including complete accessories for fixing the light to the building complete.Complete all as specified and directed.
M&L in replacement of GI Pipe Bracket made out of Galvanised Iron Tubing 40mm bore (dia), light grade, 1.50 Metre long bent to shape as per specified for fixing Security Light Fitting including suitable size of clamps and applying Two coats of Aluminium Paint over a coat of Aluminium Primer including taking down old unserviceable GI Pipe Bracket with clamps, complete all as specified and as directed.
S&F LED light fitting,10 watt bulk head luminaries complete with all accessories and including connecting up with twin core twisted gflexible copper conductor cable of suitable size complete all as specified and as directed.Make :- Havells Cat No HEXAFT10WLED857SSYMBOPC or equivalent in Phillips/CG.
Taking down ceiling fan, sealing cable end, dismantling blades and shifting to AGE E/M store and Painting of ceiling fans complete with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc and writing MES No and Hanging in its original position and connecting up including provision of cable from ceiling rose to connector of fan complete all as specified and directed by Engr-In-Charge.
Supply and fix exhaust fan with metal body, 230mm sweep, single phase, 230 volts, 50 Hz. Including making necessary arrangement of fixing with clamp on window and require size of window net all specified and directed by engr in charge.
Taking down exhaust fan, sealing cable end dismantling louvers and shifted to AGE E/M store and painting of motor , louvers with synthetic enamel paint by spraying including filling cavities with filter and changing of old UNSV parts and cleaning of dust, writing MES No and fixing in its original position complete all as specified and directed.
M&L for sub main wiring with two single core 6 sqmm PVC insulated and unsheathed copper conductor, multistranded 1100 volts grade through and including exisitng/new non metalic rigid PVC concealed conduit of suitable size including running up to 6 sqmm copper conductor multistranded PVC insulated and unsheathed wire as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing U/S sub main wiring and making good the disturbed surface to match with the existing all as specified and directed. ( Note :- Two run of 6 sqmm cable and one run of earth wire and one run of non metalic conduit shall be measured and paid as 01 RM.
Supply and fixing in Weather proof flat twin core cable size 6 Sq mm aluminium conductor PVC insulated.complete all as specified and directed.
Supply and Fixing Electronic Meter temper proof LCD Display, accuracy class-I confirming to IS 13779 of 1999. IEC 1036 and paid CBIP technical report 1988, three phase, 4 wire, 240 volts (+) 20% (-) 40% of capacity 10 to 60 Amps, 50 Hz with burden greater than 2.5 VA per phase in voltage circuit and 2 KW/10 VA per phase in voltage circuit, Class-I accuracy, anti temper proof features as specified including necessary connections with suitable size of PVC insulated copper as specified including necessary connections with suitable size of PVC insulated copper conductor cable multi stranded with appropriate size of copper lugs including Engineering plastic pilfer proof meter box to house single phase electronic energy meters. The meter box comply with IS : 5153 (Part-II) and class of protection shall not be less than IP 51, dust and vermin proof, shock proof of suitable size to house the meter freely. The door of meter box shall accommodate 9 pin D type male connector of the cable used for interface between meter and CMRI and two push buttons are to be provided on the cover of meter box so that data can be accessed without opening the cover of meter box complete fixing arrangement all as specified and directed . Make of meter box : SECURE / L&T / HPL / HAVELLS / CROMPTON GREAVES / HENSEL.
M&L for sub main wiring with two single core 4 sqmm PVC insulated and unsheathed copper conductor, multistranded 1100 volts grade through and including exisitng/new non metalic rigid PVC concealed conduit of suitable size including running up to 4 sqmm copper conductor multistranded PVC insulated and unsheathed wire as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing U/S sub main wiring and making good the disturbed surface to match with the existing all as specified and directed. ( Note :- Two run of 4 sqmm cable and one run of earth wire and one run of non metalic conduit shall be measured and paid as 01 RM.
Dismantling & taking out old RCC/ rusted steel pole 9/11 mtr long carefully from foundation complete all as specified and directed by Engineer-in-Charge.
Dismantling & taking out of aACSR conductor of any size from RCC/ rusted steel pole 9/11 mtr long carefully complete all as specified and directed by Engineer-in-Charge.
Dismantling & taking out of insulators any size from RCC/rusted steel pole 9/11 mtr long carefully complete all as specified and directed by Engineer-in-Charge.
Dismantling & taking out of cross arms, chanels, bolt nuts from RCC/ rusted steel pole 9/11 mtr long carefully complete all as specified and directed by Engineer-in-Charge.
S&L in replacement XLPE insulated, screened, PVC bedded, galvanised steen strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts sgrade, cross sectional area 10 Sqmm, 2 core laid in trenches complete all as specified and directed by Engineer-in-Charge.
S&L in replacement XLPE insulated, screened, PVC bedded, galvanised steen strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts sgrade, cross sectional area 16 Sqmm, 2 core laid in trenches complete all as specified and directed by Engineer-in-Charge.
S&L XLPE in replacement insulated, screened, PVC bedded, galvanised steen strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts sgrade, cross sectional area 25 Sqmm, 4 core laid in trenches complete all as specified and directed by Engineer-in-Charge.
M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and incl galvanized strip 25x4mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 1991 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed
S & F GI pipe light grade 50 mm dia in trenchesfor cable protection/on pole/on wall complete all as specified and diretced.
Supply and laying (in replacement) of 40mm bore dia GI tubing (light grade) with all fittings laid in trenches for cable protection complete all as specified and as directed.
M&L for boring under road horizontely of size 40/50 mm bore using GI pipe for passing of cable in road/path in hard/soft/ loose soil complete all as specified and directed.
S&F( in replacement) MS box three phase of size 297x 250 x 130 mm made out of 2 mm MS sheet factory made with inbuilt locking arrangement, out door type , fix to pole with suitable MS clamp comprising of alluminium busbar 16 Amp 04 Nos fixe on epoxy insulated pole complete all as specified and directed.
S & F in replacement of 2 runs of PVC insulated 1.5 sqmm single core multistranded copper conductor cable and one run of 1.5 sqmm copper wire as earth continuity conductor drawn through and incl rigid non metalic conduit 20 mm external dia fixed on poles & connecting up all as specified and as directed. Note: Two runs of cable and one run of earth wire and one run of conduit shall be measured as one length.
Supply and fix steel tubular swaged poles type 410SP-37(9.5 meteric long) Swan Neck Type complete with CI base plate and finial and single swan neck, Including foundation and coping complete all as specified and as directed. Make : Shubham Poles type 410 SP-37 or equivalent Bajaj / Crompton Greaves.
Supply and fix steel tubular swaged poles Type 410SP-37(9.5 meter long) Swan Neck Type complete with CI base plate and finial and double swan neck, Including foundation and coping complete all as specified and as directed. Make : Shubham Poles type 410 SP-37 or equivalent Bajaj/ Crompton Greaves Note for Item No 47 & 48 :- (a) Pole shall be made of Ms-Erw tubes confirming IS 1161 / YST 240 Gr, 410 MO A-UTS (b) Pole shall be swaged & welded as per IS 2713 / 1980 Part-II with latest amendment (c) Poles shall be tested for deflection test permanenet set test & drop test as per IS 2713 (d) Under ground portion shall be painted with black bituminous painst (e) Cast Iron Base plate shall be provided as per IS 2713
Supply and fix LED street light fitting 90 watts with high efficiency long life LEDs In-built replaceable electronic driver complete housed in pressure die-cast aluminium alloy covered with polycarbonate cover with IP66 degree of protection and fixing on existing bracket duly removing existing unserviceable street light fitting complete with service connection as specified and directed by Engineer-in-Charge. Make: Havells Cat No. ENDURAPEARLPLUSSL90WLED757PASYTOPCASTHO or equivalent in Philips/ Wipro
Supply and fix LED flood light fitting of 180 Watts with driver inside a pressure die cast aluminium housing with toughened front glass cover, IP66 degree of protection includig taking down of existig unserviceable flood light fitting of any description complete all as specified and directed by Engineer-in-Charge. Make: Havells Cat No. JETAVALOURFL180WLED757MODNBLTG or equivalent in CG/ Wipro
Supply & fixing of automatic street light switch using infrared sensor based on nature switch for automatic switching of street lights. Nature switch operation should be based on nature light lux level. Required illumination level for switching ON is <30 lux and for switching OFF >10 lux.The nature switch along with suitable power contactors , incoming and outgoing MCBs should be enclosed in a pole/ wall mountable enclosure make of rust proof , electric shock proof and FR grade SMC junction box confirming to IP 54 complete all as specified for the following: - (a) Suitable of three phase load of 5 kw with contactors (single phase 3Nos), incoming& Outgoing MCB SP (6 Nos),rating of 20-25 Amp & circuit wiring of min 10 sqmm. Make -Swadeep Cat No. swadeep -02EC 5kw3P or equivalent in siemens /Indoasian
M & L excavation in trenches in hard/dense soil not exceeding 1.5 m wide and not exceeding 1.5 mtr in depth for laying of cables/errection of pole etc complete all as specified and as directed.
All as per item No. 52, above but exceeding 1.5 m and not exceeding 3 mtr in depth complete all as specified and as directed.
M & L for returning, filling in trenches incl spreading leveling watering and well ramming in layers with hard/dense soil not exc 25 cm thick in each layer complete as specified and as directed
M & L for removing excavated soil to a distance not exceeding 1.5 m above the starting point complete all as specified and as directed
M & L for sand cushioning with a layer of river sand 23 cm thick under and above the cable complete all as specified and as directed
S & L sub class'B' burnt bricks for cable protection complete as specified as directed
M & L for PCC 1:4:8 type D2 with 40mm graded stone aggregate in foundation of poles all as specified and as directed
M & L for PCC 1:3:6 type C1 with 20mm graded stone aggregate in foundation of poles/stays incl necessary form work all as specified and as directed
M & L for PCC (1:2:4) type B1, using 20 mm graded stone aggregate as in roof kerbs / coping / bed plate and the like including weathering slightly or chamfered angle with necessary form work complete all as specified and directed.
S&F heavy duty exhaust fan with metal body, metal frame & metal blades of size 230 mm sweep, suitable for working on single phase, 230 volts, 50Hz AC supply complete including suitable nuts & bolts and connecting cable ceiling rose to exhaust fan. Make Havells Model No. Ventil Air-DSP or equivalent in Bajaj/Philips
M&L for cutting holes in stone wall (upto 60cm thick) built with cement mortar or cement lime mortar including making good using necessary brick work and plastering 1:4 to making the smooth circular hole for fixing of 230mm sweep exhaust fan and applying two coats of white wash for fair leaks and match to the existing wall including cleaning of dismantled wall material etc complete all as specified and directed
M&L for cutting hole in 45cm thick brick wall built with cement and sand including making good using necessary brick work and plastering 1:4 to making the smooth circular hole for fixing of 230mm sweep exhaust fan and applying two coats of white wash for fair leaks and match to the existing wall including cleaning of dismantled wall material etc complete all as specified and directed
K LAKSHMAN SINGH AND CO
V K ENGINEERS
Saiansh Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .