Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC 254 GOVT HOUSING COLONY CHANNAPORA SRINAGAR 190015 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190015 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹20.7 L+₹1.8 L (9.67%)Rejected-Finance | L2 | Rejected-Finance Not being L1 |
Tender Value
₹19.1 L
EMD Value
₹38,285
Closing Date
6 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 133 WORKS ENGRS
HQ 133 WORKS ENGRS
PROVN OF ELECTRIC SUPPLY CONNECTION WITH TRANSFORMER 315 KVA ALONGWITH CONNECTING ACCESSORIES FOR CT SCAN MACHINE CAP UNDER GE 864 EWS
2023_MES_621419_1
CWEK-32/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 864 EWS
Class E Category b ii
6 documents required · 6 mandatory
₹500
GE 864 EWS
₹38,285
HQ 133 WORKS ENGRS
28 Dec 2023
3 Oct 2023
14 Nov 2023
3 Oct 2023
6 Nov 2023
18 Oct 2023
3 Oct 2023 - 10 Oct 2023
11 Oct 2023
Amount
Excavation in trenches, n exc 1.5m wide and n. exc 1.5m in depth; for laying of cables ,poles stays , foundation, etc.and getting out.in hard/dense soil complete all as specified and directed.
All as per srl item No 1 but exceeding 1.5 metr in depth and not exceeding 3.0 metre, complete all as specified and directed
Returning, filling in includidng spreading leveling watering and well ramming in layers not exc 25cm.thick complete all as specified and directed.
Removing excavated material from site n exc. 50 m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and directed.
Supply and laying Unreinforced precast concrete cable coveron the cable in the trench , class HV, Type-I, flat size 300mm X180mmX40mm (for 11KV HT cable) .
M&L for Sand cushing to under ground cable, provided with 8 cms thick layer before laying the cable and 15 cm thick after laying and streching the cable complete well ramming/compressed the sand upto 18 cm all as specified and directed. Note: Punned thickness of sand will be measured and paid.
S&F cable jointing kit outdoor termination heat shinkable type joint for 11 KV (Earthed) grade cable complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm.
Supply and laying / fixing , GI pipe light grade 150mm dia bore for cable protection fixed to pole/wall or laid under floor/road/pavement, including taking out old & removal, complete all as specified and directed.
M&L for Cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concrete for repair of existing structure of transfoermers/panels/poles etc complete all as specified.
M&L for Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concrete for repair of existing structure of transfoermers/panels/poles etc complete all as specified.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 in pit, angle iron 25X25X3mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways abd 12mm dia MS fabricated handle for pit of 400 x 400 x 350mm inner size with CI cover complete all as specified and directed.
M&L for Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in benching, coping around poles (aove GL) etc ifor repair of existing structure of transfoermers/panels/poles etc complete including necessary form work complete all as specified.
Supply & fixing lightning arrestor, expulsion type complete with all fittings, transmission class, discharge capacity 11 kilo volts 65KA complete all as specified and directed
Supplying, transporting, erecting and fixing steel tubular swaged poles type 410 SP-55, 11.00 meter long, complete with cast iron base plate, final taper plug, bolts, nuts and screws as specified including painting with two coats of aluminium paint heat resistant type over one coat of red oxide primer and making 06 Nos bands/straps with white and black colour (30 cm wide each) synthetic enamel paint at a distance 30 cm from plinth block and numbering of poles with black bitumenous synthetic enamel paint in 2.5 cm height including tarring one coat on steel surface embedded in concerete foundation complete all as per specified and directed
M& L for cross arms, bracings, suppots, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
Supply and fix Switch air break gang opertated tripple pole mechanically operated from ground level mounted on 12 insulators outdoor type suitable for vertical instatllation single break provided with locking arrangement for operating handle including seven levers "Navtal" lock consisting of mild steel channel HT post top insulator copper alloy high pressure assembly with drop out expulsion fuses for phases, operating rod of 25 mm dia medium grade G.I. pipe complete conforming to IS-1018 of 1972 with continuous current rating 200 Amps 11KV grade complete all as specified.
Supply, laying, jointing, testing and commissioning of High Tension (HT) XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty, earthed electric power cable, cross sectional area 95 Sqmm 3.0 core aluminum conductor 11000volts grade under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed.
Supplying, installation, commissioning and testing of transformer step down (Level 2) 11/0.433KV capacity 315 KVA, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping + 2.5%, 5%, 7.5%, 10% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and terminal plate, plain breather device with silica gel to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- Transformer oil shall be conforming to requirements of IS-335-1993 rev -2005 specification for new insulating oil for transformers. The transformer shall be IS-1180 (Part-I) 2014 with maximum total loses as per energy efficiency level-2 of IS:1180 (Part-I 2014)
Supply and laying/fixing galvanised tubing light grade 80 mm bore laid in trenches or fix to wall/hole with fitting as required for cable protection complete with necessary fittings/fixtures all as specified and directed.
Constructruction of platform for single transformer of size 2.50m X 2.50mX1.20 m high from natural ground level with brick walling including steps, XPM fencing fixed on angle iron posts upto 1.2 M height with gate and locking arrangement, painting including top shed of CGI sheet for protection from rain and snow falling ducts for incoming & outgoing cables as per drawing No CESZ TD-1110/2011, complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, screened, stranded aluminum conductor 1100 Volts grade under ground cable of size 300 sqmm 3.5 core including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through roads etc, complete all as specified and as directed.
Earthing complete with copper earth plate electrode 60cm x 60 cm x 3.15 mm thick burried directly in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to and including copperI strip 20 x 3 mm thick thick as earthing lead by means of GI bolts,nuts, check nuts and washers test points made of copper strip 20 x 3 mm, 10 cm long ,PCC 1:2:4 type B-1 in pit, angle iron 25X25X3mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways abd 12mm dia MS fabricated handle, medium grade GI watering pipe 20mm bore with funnel, wire mess and light grade GI protection pipe 40mm bore upto 5m length for drawing in earth lead ,salt,charcol etc. including excavation and earth work in any type of soil , removal of surplus soil to a distance not exceeding 50m complete all as shown in electrical plate No. 3 of MES schedule 2009 part-I and connected complete all as specified including testing on completion.
Earthing complete with galvanised steel earth plate electrode 600mm X 600 mm X 6 mm thick burried directly in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to and including GI strip 25 x 4 mm thick thick as earthing lead by means of steel bolts,nuts, check nuts and washers test points made of GI strip 25 x 4 mm, 10 cm long ,PCC 1:2:4 type B-1 in pit, angle iron 25X25X3mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways abd 12mm dia MS fabricated handle, medium grade GI watering pipe 20mm bore with funnel, wire mess and light grade GI protection pipe 40mm bore upto 5m length for drawing in earth lead ,salt,charcol etc. including excavation and earth work in any type of soil , removal of surplus soil to a distance not exceeding 50m complete all as shown in electrical plate No. 3 of MES schedule 2009 part-I and connected complete all as specified including testing on completion. Note for item No 23 & 24 :- 1. The rates however do not include the following which shall be measured and paid separately under appropriate items/sections. (a) Excavation and earth work. (b) P.C.C. pit and C.I. cover. (e) Test point and extra length of main earthing lead beyond 7.5 metres.
M/S Khan Hussain & Co.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .