Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.9 LAccepted-AOC 1542 URBAN ESTATE II HISAR 125 005 HARYANA | HISAR | HARYANA | 125005 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹38.0 L+₹1.3 L (3.55%)Rejected-Finance HOUSE NO 44 MASTER COLONY SATROD KHAS HISAR HARYANA 125044 | HISAR | HISAR | HARYANA | 125044 | L2 | Rejected-Finance being L2 |
Tender Value
₹38.4 L
EMD Value
₹76,800
Closing Date
28 Sept 2021, 6:00 pmClosed
GE WEST HISAR
Hisar Military Station Hisar - 125006
GE(W)/HSR-15/2021-22 SPECIAL REPAIR TO BLDG NO P-235 OF 21 MECH INF AT HISAR MIL STN UNDER GE (WEST) HISAR
2021_MES_462979_2
GE(W)/HSR-15/2021-22
Open Tender
Civil Works
Item Rate
180 days
Hisar Military Station
As per tender documents
9 documents required · 9 mandatory
₹500
GE WEST HISAR
₹76,800
29 Oct 2021
8 Sept 2021
30 Sept 2021
8 Sept 2021
28 Sept 2021
14 Sept 2021
Amount
Taking down cement plaster on brick / stone wall, ceiling etc incl. raking outs joints hacking for key scrubbing with water including removing rubbish off the premises complete all as specified and directed.
Demolition cast in situ terrazo/tiles on walls including cement mortar bedding and including removing rubbish off the premises complete all as specified and directed.
Demolition of RCC in floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work, including removing rubbish off the premises complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings not exc 15cm thickness (below or above ground level), including removing off the premises complete all as specified and directed.
M&L for rendering 10 mm thick on brick masonry surfaces in CM(1:6) finished even and fair without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick on other face of brickwork wall surfaces in CM 1:4 surface finished even and fair without using extra cement complete all as specified and directed.
M&L for rendering 10 mm thick on ceiling surface in CM(1:3) finished even and fair without using extra cement complete all as specified and directed.
M&L for joint free Non Skid ceramic tiles(coloured) 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set over and incl 15mm thick screed in CM 1:6 and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for Glazed ceramic coloured tiles ( 450 x 300 mm) x 7 mm thick, on vertical surfaces such as skirting, dado and risers to steps ,wall etc set over 10 mm thick cement plaster in CM 1:4 and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Taking up or down steel tubing and connection,15 mm bore including removing from site complete all as specified and directed.
S&F GI tubing medium grade with all fitting 15 mm bore fixed to wall or concealed or fitted to ceiling or laid under floor complete all as specified and directed.
S&F 20mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
S&F brass threaded CPVC Elbow complete all as specified and directed for CPVC pipe outer dia 20mm.
S&F brass threaded CPVC Tee complete all as specified and directed for CPVC pipe outer dia 20mm complete all as specified and directed.
S&F Male/Female Brass Threaded Adaptor (MTA/ MBTA) complete all as specified and directed for CPVC pipe outer dia 20mm.
Taking up or down steel tubing and connection, including cleaning 20 mm bore including removing from site complete all as specified and directed.
S&F GI tubing medium grade with all fitting 20 mm bore fixed to wall or concealed or fitted to ceiling or laid under floor complete all as specified and directed.
S&F in repair fancy type Chromium plated stop valves (consealed type) cast copper alloy screwed down high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions in 15 mm bore complete all as specified and directed.
S&F in repair bib tap fancy type chromium plated 15mm dia cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule over and including extension piece and CP cap complete all as specified and directed.
S&F in repair angle valve, cast copper alloy screwed down high presure, with crutch of butterfly handle, screwed both ends fancy type chromium plated with long shank and cup , 15 mm complete all as specified and directed.
S& F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F in repair Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule20mm complete all as specified and directed.
S&F in repair rotational moulded polyethylene water storage tanks of capacity 1000 Litre (cylindrical vertical with closed top three layers, white colour ISI mark) hoisted and fixed in position complete all as specified and directed.
S&F in repair Vitreous China squatting pan, `Orrisa' pattern, size 580 x440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete all as specified and directed.
S&F in repair Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe ( including waste pipe) complete all as specified and directed.
S&F in repair cromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union ,125mm size complete all as specified and directed.
M&L for cement concrete type F-2 1:7:12 ( 40 mm graded aggregates ) filling and mass concrete in suken portion complete all as specified and directed.
Supply only Integral water proofing compound complete all as specified and directed.
S&F band straps supports or stays for rainwater, ventilating pipes incl bolts if required, clamps, hold fasts and similar articles confirming to Fe 1900 Gde E-165 complete all as specified and directed.
S&F in repair PVC (SWR) floor trap plain with grating including jointing with solvent cement diameter of outlet 75 mm complete all as specified and directed.
Taking down chowkats or frames with shutters not exc 1.50 Sqm each (without taking off shutters from the frames) including removing from site complete all as specified and directed.
Taking down frame sutters exc 1.5 sqm but not exc 4.00 sqm each (without taking off shutters from the frames) including removing from site complete all as specified and directed.
Taking down sutters exc 1.0 sqm but not exc 2.00 sqm each including removing from site complete all as specified and directed.
S&F for pressed steel frames of size 125 X 60 mm with one or more rebates including necessary fixing lugs, butt hinges, locks strike plate etc(thickness of sheet shall be 1.25mm) and making good the plaster of wall in CM 1:6 complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20mm Graded Stone Aggregate) as in filling of Chowkhats complete all as specified and directed.
S&F factory made Steel windows, ISI marked, (Box Type) with side hung shutters including mild steel butt hinges, tower bolts, handles etc complete with glazing bars dovetailed or welded including one shop coat of Zinc chrome primer including taking down old existing window and making good disturbed surfaces of walls,complete all as specified and directed. Notes:- (i) The rate quoted by the contractor are deemed to be included for one shop coat of red oxide zinc chrome primer on steel windows. Nothing shall extra paid on this account. (ii) Details of box type window shall be given on HQ CEJZ drawing No TD/2013/01 sheet 1/3, 2/3, 3/3. (iii) Glass pane/wire gauze shall be measured and paid separately.
S&F factory made Steel windows, ISI marked, (Box Type) with side hung shutters including mild steel butt hinges, tower bolts, handles etc complete without glazing bars dovetailed or welded including one shop coat of Zinc chrome primer including taking down old existing window and making good disturbed surfaces of walls, complete all as specified and directed. Notes:- (i) The rate quoted by the contractor are deemed to be included for one shop coat of red oxide zinc chrome primer on steel windows. Nothing shall extra paid on this account. (ii) Details of box type window shall be given on HQ CEJZ drawing No TD/2013/01 sheet 1/3, 2/3, 3/3. (iii) Glass pane/wire gauze shall be measured and paid separately.
S&F factory made box type Steel ventilator with top hung shutter including hinges, steel peg stay, taking down old existing ventilator and complete all as specified and directed.
M&L for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, chajja, cooler stand and similar work conforming toFe-290(Gde E-165) complete all as specified and directed.
S&F Sheet glass ordinary quality and glazingwith oil puttyin square n.exc 0.50 sqm in each pane in 3 mm thickness complete all as specified and directed.
Hacking out old broken glass any thickness, size, quality from steel frames glazed with putty complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S&F Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F 35mm thick factory made plain, framed, paneled door shutters kiln seasoned and chemically pressure treated second class, hardwood (two panels) with lock rail and panel of 9mm thick BWP commercial marine grade ply wood bonded with high quality liquid phenol formal dehyde synthetic resin adhesive confirming to IS-710. The size of rails and style shall be as per IS-1003 complete all as specified and directed.
S&F 35mm thick factory made second class hardwood glazed and skelton door shutter kiln seasoned and chemically treated, open rebated and prepared to receive glass/ gauge etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc complete. The size of members of shutters shall be as specified in MES SSR Part-I complete all as specified and directed.
S&F Aluminium anodised barrel tower bolts of extruded section and fixed 150 mm complete all as specified and directed.
S&F aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clip of sheet,cast or extruded section, bolt not less than 16 mm dia, 300 mm long complete all as specified and directed.
S&F Butt hinges, medium weight, cold rolled mild steel, and fixed 100 mm complete all as specified and directed.
S&F aluminium handles extruded fabricated type anodized of size 125mm complete all as specified and directed.
S&F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F in repair Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
M&L for preparation of new plastered wall surfaces and applying two coat of oil emulsion distemper of any tint over a coat of wall care putty minimum 1.5mm thick complete all as specified and directed.
M&L for removal of existing tretment of plastered wall surfaces and applying two coat of oil emulsion distemper of any tint over a coat of over a coat of wall care putty minimum 1.5mm thick complete all as specified and directed.
M&L for preparing new plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed.
M&L for preparing old plastered surfaces and applying two coats of white wash on ceiling complete all as specified and directed.
M&L for preparing old wooden surfaces of any description exc 10cm width or girth and applying one coat of synthetic enamel paint of any tint complete all as specified and directed.
M&L for preparing new wooden surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint of any tint over a coat of pink primer complete all as specified and directed.
M&L for preparing old steel surfaces of any description exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparing new steel surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint of any tint over a coat of red oxide complete all as specified and directed.
M&L for preparing new steel surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint of any tint over existing primed surface complete all as specified and directed.
M&L for preparing new plastered surfaces and applying two coats of cement base paint over one coat of primer on wall complete all as specified and directed.
M&L for preparation of old decorated plastered or unplastered surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soots, moulds, moss and efflorescent salts and trading oil & greasy spots including cornices etc and applying one coat of cement base paint, white or tinted complete all as specified and directed.
M&L for 50mm thick, cement concrete 1:3:6 type C1 using 20mm graded crushed stone aggregate as in plinth protection, finished even and smooth without using extra cement, including making joints 12mm wide to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete all as specified and directed. .
S&F in reapair PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors dia of pipe 110mm complete all as specified and directed.
S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors dia of pipe 75 mm complete all as specified and directed.
S&F in repair PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls dia of pipe 110mm complete all as specified and directed.
S&F in repair PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wallsdia of pipe 75mm complete all as specified and directed.
S&F in repair PVC Bends 110mm bore, with oval access doors complete all as specified and directed.
S&F in repair PVC (SWR) junction single,(Single T) equal or unequal 110 mm bore complete all as specified and directed.
S&F in repair PVC Bends 75 mm bore, with oval access doors complete all as specified and directed.
S&F PVC (SWR) vent cowl 110mm complete all as specified and directed.
M&L for Brickwork with old size flyash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles including removing rubbishh off the premises complete all as specified and directed.
S&F in repair PVC syphonic action type flushing cistern, low level of capacity 10 litre white with inlet ball valve float and handle including brackets complete all as specified and directed.
M&L for machine cut Kota stone slab flooring 20-25 mm thick over 15 mm thick cement screed base laid in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. Note : For staircase treads and window cill etc kota stone shall be laid in one peice upto 1.50m length.
M&L for Kota Stone Slab 20-25 mm thick in riser of steps , skirting , dado and pillar laid over 15 mm thick cement plaster in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. Note : For staircase treads and window cill etc kota stone shall be laid in one peice upto 1.50m length.
Demolition Mud in roofs, any thickness,including plastering and leeping (whether full thickness or only a part thereof) including removing off the premises complete all as specified and directed.
Demolitin of Brick tiles or terracing tiles, single layer on roofs including removing off the premises complete all as specified and directed.
M&L for cement concrete 1:2:4 mix type B-1 (20 mm graded stone aggregate) in padding over roof complete all as specified and directed.
M&L for applying roof treatment on top of roof with APP based polymeric membrane (not less than 3mm thick , weight not less than 3.5Kg per Sqm, reinforced with polyster non-woven fabric ( weigthing not less than 150 gm/ Sqm ) laid by torch application method with side overlap 75mm and on end 100mm as per manufacture's instructions over a coat of hot paving bitumen of grade 30/40 conforming to IS 73 @ 1.2 Kg/ Sqm over a coat of bituminous primer conforming to IS -1984 @ 0.40 Kg /Sqm and applying two coats of aluminium paint over APP membrane over and incl 15mm thick plaster in cm 1:4 using liquid WPC as per manufacture instruction over RCC roof complete all as specified and directed
S&F in repair gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed for 15mm dia pipe complete all as specified and directed.
S&F in repair gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed for 20mm dia pipe complete all as specified and directed.
S&F 300mm ordinary helical door springs incl roller & roller plate of mild steel complete all as specified and directed.
S&F in repair salt glazed stone ware gully traps in repairs square or rounded mouthed type P or S of size 150 x 150cm incl excavation earth work conc in Beds, surrounds kerbs etc complete all as specified and directed.
Demolition and breaking up drain pipes (salt glazed stoneware, AC or reinforced concrete pipes) 150mm internal dia set in cement mortar including removing from site complete all as specified and directed.
S&F salt glazed stoneware drain pipes grade A, 150mm dia laid in trenches and jointed in cement complete all as specified and directed.
M&L for concrete bed in PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) to drain pipes of 150 mm bore including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire 0.9 mm dia complete all as specified and directed.
Ditto as per item No 89 above but 6 to 8mm dia -ditto-.
Ditto as per item No 89 above but for 5mm dia and over upto and incl 10mm dia in stirrups, spacers and binders.6 to 8mm dia -ditto-.
M&L for form work to chullah hoods, chajjas, troughs and similar items including edges finish with rough finish flat surface complete all as specified and directed.
M&L for RCC M-25 (Design mix) (using 20mm graded stone aggregates) as in as in Chajjas complete all as specified and directed.
M&L for providing precast cement concrete type B-I 1:2:4 (using 20mm graded stone aggregates) in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs,mangers, shelves and similar articles with plain face set in cement mortar 1:4 complete all as specified and directed.
Cutting holes into or through brick walls built in cement mortar and making good in cement concrete 1:2:4 type B-l as required superficial area exc 150 Sqcm and n.exc 400 Sqcm complete all as specified and directed.complete all as specified and directed.
Chipping of loose/ damaged / cracked / previously repaired/ delaminated or weak concrete by chieseling to expose the sound core concrete where ever required and to expose rusted reinforcement upto depth n.exc 50mm and disposal of rubbish off the premises to a distance not exc 50 mtrs including cleaning of reinforced concrete surface by air compressor complete all as specified and directed.
Supply and apply of rust remover cum passivator to remove rust from existing reinforcement by using Product : Rustoff-100 of Sika or equivalent make in Fosroc / Thermax as approved by GE, with density : 1.01 Kg/ltr at 30°C and consumption : 0.2 kg/Sqm/coat complete all as specified and directed. Note : The material to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar complete all as specified and directed.
M&L for cement based polymer modified rebar corrosion protection system to existing reinforcement using cement based polymer modified rebar corrosion protection system with consumption : 3.75 kg/Sqm for two coats and product requirements: carbonation resistance : 2 mm of SikaTop Armatec®-108 of Sika or equivalent make in Fosroc / Thermax as approved by GE corresponds to 20 mm of normal mortar; bond strength > 1N/Sqmm according to ASTM C 882-78 complete all as specified and directed. Note : The material to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar complete all as specified and directed.
M&L for providing, mixing & applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacturer’s specification including prepartaion of surface throughly and cleaning complete where ever required with using Product : Sikadur®-32 LP of Sika or equivalent in Fosroc /Thermax as approved by GE with consumption : 0.4 kg/Sqm and Product requirements : Comp with ASTM C 881-78, Type II Grade 2 Class B+C complete all as specified and directed.
M&L for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122F of Sika or equivalent make in Fosroc / Thermax as approved by GE at an average thickness exceeding 10mm and upto 25mm to the prepared concrete substrate in soffit of slabs, beam, columns, parapets, fins and facias at any height, including finishing of applied Polymer mortar as per the technical specifications and manufacturer's instructions complete all as specified and directed.
M&L for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122F of Sika or equivalent make in Fosroc / Thermax as approved by GE at an average thickness of upto 10mm to the prepared concrete substrate in soffit of slabs, beam, columns, parapets, fins and facias at any height including finishing of applied Polymer mortar as per the technical specifications and manufacturer's instructionscomplete all as specified and directed.
M&L for providing, fixing shear connector of 10 mm dia TOR steel upto 160 mm length with Sika anchorfix @ -2+ Tropical or equivalent make in Fosroc / Thermax as approved by GE, epoxy resin to RCC member including power drilling, cleaning of holes, insertion of epoxy, placing shear connector in position to ensure the bond as per manufacturer’s instructions complete all as specified and directed.
M&L for cutting V groove (15mmx10mm) along the crack line and cleaning the same with high pressure water jet and sealing with fast setting high strength Epoxy putty, solvent free, three component compound based on epoxy resins, graded fillers and thixotropic agents using Sikadur 31 of Sika or equivalent make in Fosroc / Thermax as approved by GE as per the technical specifications and manufacturer's instructions complete all asspecified and directed.
M&L for providing and fixing 12-16mm dia injection ports non returnable nozzle by drilling cleaning and sealing holes 50-75 mm deep at 200mm c/c with fast setting high strength Epoxy putty, solvent free, three component compound based on epoxy resins, graded fillers and thixotropic agents using Sikadur 31 of Sika or equivalent make in Fosroc / Thermax as approved by GE as in beams, columns and parapets as per the technical specifications and manufacturer's instructions complete all as specified and directed.
M&L for grouting of nozzles with low viscous moisture insensitive, High strength, epoxy resin grout with Sikadur 52 LP (IN) of Sika or equivalent make in Fosroc / Thermax as approved by GE with pressure not exceeding 2-3 kgf/Sqcm till the nozzle refuses to take further grout including cutting extra length of the nozzle after the grout hardens and finishes as per the technical specifications and manufacturer's instructions complete all as specified and directed.
M&L for applying a ready to use non shrink, cementitious free flow microconcrete (<100 mm) using Product : SikaRep® Microcrete-4 + adequate coarse aggregate, Yield: approx. 17 ltr/bag (30kg) (depending on the size and quantity of coarse aggregate added), Product : SikaRep® Microcrete-4 or equivalent make in Fosroc / Thermax as approved by GE, Product requirements: compressive strength > 60 N/Sqmm (28 days) according to ASTM C 1107-99 complete all as specified and directed.
M&L for providing and application of one coat of Water based concrete curing compound with low viscosity wax emulsion using Sika Antisol E - WP of Sika or equivalent make in Fosroc / Thermax as approved by GE, as concrete curing membrane over the applied polymer mortar as temporary curing membrane as per the technical specifications and manufacturer's instructions complete all as specified and directed.
Providing and erecting hydraulic & manual steel props upto full height, braced at centre, resting on wedge and block to support the structure provisionally during repair work and maintaining them in position till required and as directed. Note : Hydraulic & manual steel props will be provided, erected and maintain the interval distance of steel props c/c at site on the basis of site reqmt complete all as specified and directed.
M&L for weld-mesh of size 75x75x3mm to be wrapped on the exposed surface of rib of beam & on the slab bottom and tack welding to the exposed reinforcement at close intervals and gunite with cement mortar 1:3 mixed with admixture SIKA Plasto creat plus or equivalent make in Fosroc / Thermax as approved by GE around rib of beam or roof slab of thickness n.exc 40mm to be applied under an operating pressure. the gunited surface to be cured properly for a min of 7 days all in complete as per the technical specifications and manufacturer's instructions complete all as specified and directed.
M&L for providing and fixing water tight centering and shuttering including bolting, strutting, propping etc. including removal of form work from column, beam etc. complete as per site requirement complete all as specified and directed.
M&L for treatment of sunken floor slab comprising of the following specifications complete all as specified and directed :-
(i) Cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. Provision of 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding conc to achieve proper slope including cutting holes in bricks or RCC wall for spout.
(ii)Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with and including integral water proofing compound Sika Plastocreat plus or equivalent make in Fosroc / Thermax as approved by GE @ 0.2% by wt of cement consumed including filling it with water to check dampness and seepage and where dampness / seepage is noticed, nozzles shall be fixed and grouting carried out.
(iii)All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy puty Sikagard 694 F (I) or equivalent make in Fosroc / Thermax as approve by GE.
(iv) After drying putty, wash the slab and sides of sunken portion with water andmake it clear and clean.
(v) Applying two coats of polymer modified cementious water proof coating with Sika Topseal 107 or equivalent make in Fosroc / Thermax as approved by GE in two coats @ 3kg/sqm to sandwiched with glass fibre reinforcement : Sika® Fab-1 or equivalent make in Forsro / Thermax as approved by GE over base coat as per manufacturs instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion.
(vi) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound SIKA plastocreat Plus or equivalent make in Fosroc / Thermax as approve by GE @ 0.2% by wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout.( WPC shall be measured & paid separately)
(vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint (Black Japan shall be paid separetely).
NOTE : Item No 96 to 111.07 shall be executed by authorized applicator of manufacturer as approved by accepting officer)
Taking down carefully copper/aluminum point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduit with switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed.
M&L for Point wiring with 1.5 sqmm(22/.3mm) PVC insulated and unsheathed FRLS single core multistranded copper conductor for one light/fan/bell point in and including PVC rigid non metallic concealed conduit 19/20 mm dia, medium duty, ISI Marked to be terminated in and including pressed steel terminal boxes with 3 mm thick bakelite sheet top cover including 1.5 sqmm (22/.3 mm ) PVC insulated and unsheathed FRLS single core multistranded copper earth continuity conductor to common earth and connecing to earth dolly for one light/ ceiling fan /bell point controlled by one one switch including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment complete all as specified and directed. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).
All as per item No. 113 above but for one 5 Pin 5 Amp socket outlet on the same board controlled by one number one way switch on same board.
All as per item No. 113 above but for one 5 pin 5 Amp socket outlet on independent board controlled by one number one way switch on independent board.
All as per item No. 113 above but for 15 Amp socket out let by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi strand on independent board including provn of 2.50 Sqmm unsheathed, multi stranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed.
Taking down carefully copper/aluminium Submain wiring from battan /conduit from DBs,MCBs, etc) and making good to disturbed surfaces of walls, floor etc. all as specified and directed
S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 6 sqmm, 1100 votls grade drawing through and including PVC casing and caping with acessories and including PVC insulated 6 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly complete all as specified and directed. (Note:- Two lengths of 6 Sqmm cable, one length of 6 Sqmm cable and one length of PVC casing and caping will be measured as one length).
S&F switch bell push modular flush type, single pole, one way, 5 Amp, 230/240 Volts complete all as specified and directed.
S&F LED bulb of capacity 9 watts complete all as specified and directed.
S&F in replacement LED tube rod only having aluminimum extrusion 18/20W, 4 ft existing tubelight fitting complete all as specified and directed.
S&F modular socket outlet multipurpose 3&6 Pin, 16 Amp 230 volts AC complete all as specified and directed.
S&F modular socket outlet multipurpose 2&3 Pin, 5/6 Amp 230 volts AC complete all as specified and directed.
S&F modular socket outlet multipurpose 2&3 Pin, 6/16 Amp 230 volts AC complete all as specified and directed.
S&F modular Lamp holder angular facing insulated body, batten/angle type complete all as specified and directed.
S&F modular fan reglator step type 2 module 230 volt complete all as specified and directed.
S&F modular ceiling rose surface bakelite, 3 terminals with back plate etc complete all as specified and directed.
S&F in replacement only LED batten CRCA sheet box type fixture 4 feet, long single side connection suitable for 18/20w LED tube light rod with G13 lamp holders complete all as specified and directed.
S&F MCB SPN, 32 to 40 Amps 240 Volts , type 'B' curve, 10 KA, for fixing in DB including taking down old u/s MCB complete all as specified and directed.
S&F MCB SP, 5 to 32 Amps 240 Volts , type 'B' curve, 10 KA, fixing in DB including taking down old u/s MCB complete all as specified and directed.
S&F in repairs sheet metal enclosures for DBs when MCBs to be used Single pole and neutral, 240 Volts with 200 Amps rated busbar 8 way double door complete all as specified and directed.
S&F in repairs Sheet metal enclosures for MCCB DBs when MCCB, MCBs used VTPN 415 Volts with 200 Amps rated busbar 4way double door complete and all as specified and directed
S&F MCCB 63 Amps 3 pole , breaking capacity 16 KA complete all as specified and directed.
Taking down carefully ceiling fans any make of 1200mm sweep for re-fixing cleaning, greasing, oiling and servicing and making connections completed all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/ equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore upto 7.50 metre long GI pipe light grade for earth wire protection fixed with poles/wall with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing.
Supplying laying, jointing, testing and commissioning of LT UG XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade of size 50 sqmm 3.5 core including taking down old U/S cable complete all as specified and directed. (Note :- cable may be laid in trenches, under road, across the nallah, along poles/walls and in ducts etc . Eexcavation, earhtwork, sand cushioing, cable cover, pipe for cable protection to be measured and paid for separtely) complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out and getting out in soft/ loose complete all as specified and directed.
Returning filling with earth obtained from excavation including spreading, consolidation in layers not exceeding 15 cms thick, complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50m & depositing at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for Sand filling in trenches with clean dry fine sand unwashed 8cm thick below cable and 15 Cm thick after laid thincluding gently punning around cables complete all as specified and directed Note : 18cm punned thickness shall be measured and paid
M&L for bricks covering to under ground cable using sub class B bricks laid dry, flat, perpendicular to the direction of the cable complete all as specified and directed.
S&F in replacement LED street light luminaries of cap 30 watt, SPD 10 KV internal with lense, 240 volt, pressure dia cast aluminium housing frame, heat resistant toughtened clear glass with frame complete with accessories , IP 66 protection, pre wired up to a terminal block and mounting/attachment of GI pipe 40mm dia light grade bend to required shape for fixing of light of length 1.2 mtr including MS clamps nuts bolts & washer duly required with PCC in wall complete all as specified and directed.
M&L for replacement of 50 mm bore GI pipe light grade laid in trenches or fixed to wall/pole for protection of cable/earthing strip etc complete all as specified and directed.
m/s AR Construction co
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .