Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.7 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest | |
| 2 | L2₹39.6 L+₹1.7 L (4.50%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than lowest | |
| 3 | L3₹40.8 L+₹2.8 L (7.50%)Rejected-Finance VEENA SADAN PLOT NO 63 VARANGAON ROAD SUNDAR NAGAR BHUSAWAL 425201 | BHUSAWAL | JALGAON | MAHARASHTRA | 425201 | L3 | Rejected-Finance Rejected being other than lowest |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
8 Feb 2020, 6:00 pmClosed
Shri Ravinder Kumar AGE CONTRACTS
GE (S) Ahmednagar, Military Engineer Services, Ahmednagar- 414002
Provn of toilet blocks for 27 Mech Inf, static tank at amn dump and certain minor works at Bhusawal under GE (S) Ahmednagar
2020_MES_313946_1
8674/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Bhusawal
Class D cat a(i)
7 documents required · 7 mandatory
₹500
Garrison Engineer (South) Ahmednagar
₹78,000
Yes
27 Feb 2020
11 Jan 2020
10 Feb 2020
11 Jan 2020
8 Feb 2020
25 Jan 2020
11 Jan 2020 - 17 Jan 2020
Amount
B&R Works:-
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes, cables etc not exc. 10 Sqm on plan and not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
All as per item No. 1.01 here in before but depth exc 1.5 m and n. exc 3.0 m deep.
Excavation over areas not exc 1.5 m deep and getting out in hard / dense soil complete all as specified and directed.
PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in bed to drain pipe including packing under and haunching against the sides of pipes after they are laid and tested complete for 150 mm bore pipes complete all as specified and directed.
Hard core of broken stone or boulders of gauge not exc 63mm deposited, spread & levelled in layers not exc 15cm thick, including watering and ramming to a true surface complete all as specified and directed. Note:- Volume of hard core after consolidation will be measured and paid.
Moorum/red bajri filling in floors or pavings, hard standing and in foundation laid in layers not exc 15cm thick, spread, levelled and rammed including watering complete all as specified and directed.
Cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
Reinforced cement concrete M-25 design mix (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies deck slabs, and in shelves and the like complete all as specified and directed.
Mild steel TMT bars 10 mm dia and over cut to length, bent to shapes required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per item No 1.09 here-in-before but 6mm to 8mm dia
All as per item No 1.09 here-in-before but 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders.
Use & waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landing horizontal or slopping similar work not. exc 200mm thick, and flat fair finished surfaces complete all as specified and directed.
Use & waste of form work to edges of concrete flats, treads etc thickness exc. 10cm but n.exc 20 cm and sides of RCC / PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide for flat fair finished surface complete all as specified and directed.
Cement concrete 1:2:4,type B1 (using 20 mm graded stone aggregate) as in manhole covers etc complete all as specified and directed including use of form work.
Brick work with fly ash old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
Brick work with fly ash old size bricks, straight or curved on plan to any redious in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
Rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and fair complete all as specified and directed.
Rendering 15 mm thick in CM 1:6 on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Rendering 5 mm thick in CM 1:3 on concrete surface of ceiling, finished even and smooth without using extra cement complete all as specified and directed.
15 mm thick screed bed over roof surfaces in CM 1:4 finished even and smooth without using extra cement using water proofing liquid @200 ml/ 50 kg of cement complete all as specified and directed. Note:- Water proofing liquid will be measured & paid separately.
Supply only liquid integral water proofing admixture of make pidilite or its equivalent complete all as specified and directed.
Use & waste of form work to sides of concrete foundation, footings, bases of columns raft and raft beams, side and soffits (if any) of foundation and plinth beams, and similar work vertical or to batter for flat rough finished surfaces complete all as specified and directed.
Use & waste of form work to sides of pillars, posts, struts, pears, columns and stanchion square or rectangle or polygonal for fair finished surfaces complete all as specified and directed.
Use & waste of form work to sides and soffits of floor or roof beam, beams hunching, girders, bressummers, lintels, cantilevers, shelves supports, over hang etc also splays between floor and beams etc flat fair finished surfaces complete all as specified and directed.
Use & waste of form work to chullah hoods, chajjas, throughs and similar items including edges, flat fair finished surfaces complete all as specified and directed.
Preparation of newly plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed.
Preparation of newly plastered surfaces and applying three coats of white wash on walls complete all as specified and directed.
Preparation of newly plastered walls surfaces and applying two coats of cement base paint over a coat of white wash complete all as specified and directed.
Solid PVC door frame of sixe 50mm x 47mm made out 5mm thick PVC sheet prelaminated on single side and plain on other side reinforced with MS square tube including painting of edges to match with prelaminated sheet, fixed in opening as per specification stipulated in SSR Part-II (2004) complete all as specified and directed.
Factory made solid paneled PVC door shutter 30mm thick (Style) consisting of frame made out MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain cover PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for style and plain PVC sheet plain colour PVC sheet for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail paneling of both side prelaminated solid PVC sheet to be fitted on the MS frame welded/sealed to the stiles, rails with suitable PVC sheet beading and jointed together with solvent cement, stiles and rails feathered at edges including fixing in the frame at site as per specification stipulated in SSR Part-II (2004) complete all as specified and directed.
125 mm long aluminium anodized barrel tower bolt of extruded section complete all as specified and directed.
300 mm long aluminum alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts or extruded section or cast aluminum alloy and fix complete all as specified and directed.
Coloured glazed ceramic tiles 350 x 250 x 7mm thick, on vertical surfaces such as skirting, dados and risers to steps etc set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles over and including 15mm thick cement screed bed in CM 1:4 complete all as specified and directed.
100 mm thick Cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base to floors finished fair and even complete all as specified and directed.
40 mm thick cement concrete 1:2:4, type B-0, (using 12.5 mm graded stone aggregate) as in sub base to floor finish fair and even complete all as specified and directed.
Non skid ceramic coloured tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles over & including 15mm thick cement screed in CM 1:4 complete all as specified and directed.
100 mm long aluminium butt hinges, extruded aluminium alloy with galvanized Mild steel hinge pin, anodized type B-22 complete all as specified and directed.
Preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and as directed.
4 mm thick figured glass pin head type and glazing with oil putty in squares not exc. 0.5 Sqm in Each pane complete all specified and as directed.
1000 Ltr Capacity rotational moulded double layer polyethylene water storage tank (cylindrical vertical with closed top) ISI marked, hoisted and fixed in position all as specified in SSR Part-I complete all as specified and directed.
15 mm bore stop valve of PTMT any colour high pressure screwed for iron pipe and fixed with long shank and cup (concealed type) (minimum weight 110 gms) complete all as specified and directed.
Gun metal, globe or gate valves 25 mm, with iron sheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 455gms) complete all as specified and directed.
Grating doom 100 mm dia of PTMT (minimum weight 25 gms) complete all as specified and directed.
PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
PVC (SWR) 75mm bore pipes single socketed in any length with rubber ring joints laid on floors complete all as specified and directed.
PVC (SWR) 110mm bore pipes single socketed in any length with rubber ring joints fixed to floor complete all as specified and directed.
PVC (SWR) 110mm bore pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
PVC (SWR) 75mm bore bends any radius complete all as specified and directed.
Galvanised iron tubes,15 mm bore, medium grade with all fittings, laid in trenches complete all as specified and directed.
All as per item No. 1.50 here in before but 20 mm bore pipe.
All as per item No. 1.50 here in before but 25 mm bore pipe.
75 mm bore outlet cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete 1:2:4,type B-1 complete all as specified and directed.
Factory made steel ventilator with top hung shutter including hinges peg stay to receive glazing or gauzing and fixing of hold fast size 25 x 5 mm of flat iron including one shop coat of Red Oxide Zinc chromate primer complete all as specified and directed. Note:- Glass shall be measured and paid for separately.
15 mm bore bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed (minimum weight 90 gms) complete all as specified and directed.
Brass chromium plated shower rose 150mm dia with or without swivel joint including fixing to steel pipe or union complete all as specified and directed.
Towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/ plastic clits (minimum weight 190gm) complete all as specified and directed.
Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300 gms) complete all as specified and directed.
Vitreous China squatting pan, Orissa pattern, size 580mm x 440mm white with integral foot rests (excluding flushing cistern and flush pipe etc) including making good to floor complete all as specified and directed.
Flush pipe of polythene of low or high density 32 mm PVC for low level flushing cistern complete all as specified and directed.
10 litre capacity PVC valveless syphonic action type flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed.
100 mm bore cast iron 'P' or 'S' trap, fixed in position complete all as specified and directed.
PVC (SWR) 75 mm bore vent cowl, fixed in position complete all as specified and directed.
PVC (SWR) 110 mm bore bends any radius jointed with solvent cement complete all as specified and directed.
PVC (SWR) 75 mm bore pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
Vitreous china wash basin, white, flat back, size 630 x 450 mm excluding taps,chain and plug and porcelain stopper complete but including chromium plated waste coupling, waste pipe and brackets complete all as specified and directed.
15 mm bore pillar taps of PTMT, any colour, fancy type (minimum weight 120gms), screwed for iron pipe complete all as specified and directed.
Mild steel screw bolts (machine made), 5 to10mm dia with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washer and one hexagonal or square nut exc 5cm but not exc 10cm long complete all as specified and directed.
All as per item No 1.69 above but length of bolt exc 22.5 cm and not exc 30 cm and dia of neck 16 to 20mm.
PVC gully trap 125 mm x 110 mm, setting and jointing with solvent cement complete all as specified and as directed.
PVC (SWR) 75 mm bore branch piece, single (Single Y) equal or unequal jointed with solvent cement complete all as specified and directed.
PVC (SWR) 110 mm bore branch piece, single (Single Y) equal or unequal, jointed with solvent cement complete all as specified and directed.
PVC (SWR) 75mm bore branch piece, double (Double Y) equal or unequal, jointed with solvent cement complete all as specified and directed.
PVC (SWR) 110mm bore branch piece, double (Double Y) equal or unequal, jointed with solvent cement complete all as specified and directed.
Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Sand filling under floor or in foundation including watering and consolidation complete all as specified and directed.
Reinforced cement concrete M-25 Design Mix (using 20mm graded stone aggregate) in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc basement slabs, under reamed piles and mass concrete complete all as specified and directed.
Reinforced cement concrete M-25 Design Mix (using 20mm graded stone aggregate) as in columns, pillars, piers, posts & struts etc complete all as specified and directed.
Reinforced cement concrete M-25 Design Mix (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintel over 1.5 m clear span complete all as specified and directed.
Reinforced cement concrete M-25 Design Mix (using 20mm graded stone aggregate) as in chajjas etc complete all as specified and directed.
75 mm thick cement concrete1:3:6 type C-1 (using 20 mm graded stone aggregate) as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 3.0 mtr in length surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed.
Removing excavated soil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above starting point complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25cm in soft / loose soil complete all as specified and directed.
Brick work with fly ash old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and directed.
150 mm internal dia reinforced cement concrete pipes of approved make , class NP2, laid and jointed in cement mortar with collars (PCC shall be measured and paid for seperately under respective item) complete all as specified & directed.
PCC 1:4:8 type D-2, using 40 mm graded stone aggregate as in concrete bed to drain pipes, any type, of 150 mm internal dia including packing under and hunching against the sides of the pipes after they are laid & tested complete all as specified and directed.
Cement concrete factory made interlocking tiles of concrete conforming to IS: 15658 - 2006, grade not less than M-40, minimum thickness 80 mm, machine pressed of pattern as approved by Engineer-in-Charge laid over and including a layer of stone dust not less than 30 mm thick, set and jointed with stone dust complete all as specified and directed.
Cement concrete 1:3:6, type C1 (using 20 mm graded stone aggregate) as in edges of interlocking paver blocks including necessary form work weathering, slightly rounded or chamfered angles & throating complete all as specified and directed.
Reinforced cement concrete M-30 Design Mix (using 20mm graded stone aggregate) as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc basement slabs, under reamed piles and mass concrete complete all as specified and directed.
Cement concreteM-30 Design Mix (using 20mm graded stone aggregate) in walls, retaining walls any thickness, size or shape above top of footings, including pilasters, buttresses complete all as specified and directed.
Septic tank including inlet & outlet chambers for 50 users, brick construction (with top of slab at ground level) including necessary excavation and earth work in any type of soil and disposal of surplus soil to a distance not exceeding 50 m, brick work in sub class 'B' bricks built in CM (1:4), RCC as in slab including RCC manhole covers factory made ISI marked conforming to IS 12592 with angle iron frame 100 mm bore cast iron sand cast vent pipes with cast iron cowls complete all as specified and shown in drawing No. CEPZ/88/TD/17M dated 01 Oct 88, sheet 1/4 to 4/4.
Soakage well 1.20 m dia and 3.00 m deep below inlet pipe level (depth from inlet pipe to ground level 45 cm) including excavation and earth work in any type of soil filled with brick bats, RCC slab with RCC manhole cover factory made ISI marked conforming to IS 12592 fixed in angle iron frame, SWG single junction inlet filling around slab in slopes and disposal of surplus soils to a distance exceeding 50 m but not exceeding 100m complete all as specified and shown in drawing no.CEPZ/2004/TD/8 Sheet No. 1/1, dated 30 Jun 2004
Internal and External Electrification
Point wiring with 1100 volts grade single core FR PVC insulated and unsheathed cable with standard copper conductor 1.50 sqmm drawn in and including electrical grade PVC conduit 20 mm bore, IS 9537(Part-III) 1983 marking medium grade concealed in wall/ceiling including PVC insulated unsheathed earth wire with copper conductor of size 1.50 sqmm, concealed metal boxes sunk on wall for mounting of switches switch sockets fan regulator etc complete all as specified for one light point or fan point controlled by one switch complete all as specified and directed. Note: - The rate quoted shall be deemed to have included for cutting chasing and plastering as required etc and making good for concealed wiring. (Switches, sockets & regulator etc. shall be measured & paid for seprately.)
Switch piano flush button single pole one way 5 amps,230 volts, fixed complete all as specified and directed.
Ceiling rose surface bakelite 65 x 50 mm, 2 to 3 terminals, polycarbonate / PVC / isolated body, fixed complete all as specified and directed.
Lamp holder angular type insulated body backlite with back plate for angular/battern holder complete all as specified and as directed.
LED 1x10W, 230V, bulk head luminaire with lamp holder etc complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
Non retrofit LED lamp two pin suitable for 10 W batten fitting complete all as specified and as directed.Make Phillips/Crompton/Havells
LED fitting, 1x24 W, 230V, energy efficient, T5, box type, epoxy powder coated, CRCA sheet housing with reflector cover channel, electronic ballast, bipin holders, connector block etc complete with accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.
Sheet metal enclosure MCB-DB, SPN, for 240V, 6 ways with 200 Amp rated copper bus bar, flush /surface mounting, double door type complete all as specified and as directed.
MCB, SPN, 240 volt, 6 to 32 amps, 10 KA breaking capacity 'B' series complete all as specified and as directed.
MCB, SP, 240 volt, 6 to 32 amps, 10 KA breaking capacity 'C' series complete all as specified and as directed.
Sand cushioning to under ground cable with a layer of fine sand 8 cms thick before laying of cables and 15 cms thick after laying of cable in trenches complete all as specified and directed.(For payment prooned down thickness of 18 cm shall be considered)
Brick protection with fly ash bricks laid flate in trenches over the cable with length of brick perpendicular to the direction of the cable, adjacent/abutting each other, laid dry complete all as specified and diercted.
LT XLPE insulated screened PVC bedded galvanised steel strip or wire armoured underground heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 10 Sqmm 2 core laid in trenches, under floor/roads/hard standing along poles etc including testing & commissioning as in repairs, complete all as specified and directed. Note:- Excavation and earth work, sand cushioning, pipe / cable protection shall be measured and paid separetely.
All as per item No 2.13 hereinbefore but of size 3.5 core 70 Sqmm
All as per item No 2.13 hereinbefore but 16 Sqmm, 4 core
HT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power multistranded heavy duty cable of size 3 core, 95 Sqmm with aluminium conductor, 11000 volt grade, laid in trenches or passing through pipes/ducts etc. complete all as specified and directed.
Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm including testing complete all as specified and directed.
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm including testing complete all as specified and directed.
Galvanised iron tubes, 100 mm bore, light grade with all fittings for cable protection passing under road / floor or for fixing to pole / wall complete all as specified and directed.
Galvanised iron tubes, 50mm bore, light grade with all fittings for cable protection passing under road / floor or for fixing to pole / wall complete all as specified and directed.
All as per item No 2.20 hereinbefore but 40 mm bore
Solar LED standalone street light system( 2 days backup) having 30 Watt solar SLS, luminaire 30 watt, solar panel-75 Wp, 12 V battery, 40 Ah including LED street light & HDG tubular pole 6 mtr long including excavation, returning filling & removal and PCC 1:2:4, type B1, using 20 mm graded stone aggregate complete all as specified and directed. Make : X-ERA RTECH or equivalent as approved by GE
Solar LED standalone street light system( 2 days backup) having 40 Watt solar SLS, luminaire 40 watt, solar panel-100 Wp, 12 V battery, 50 Ah including LED street light & HDG tubular pole 6 mtr long including excavation, returning filling & removal and PCC 1:2:4, type B1, using 20 mm graded stone aggregate complete all as specified and directed. Make : X-ERA RTECH or equivalent as approved by GE
Earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 x 6 mm thick burried directly in ground (earth plate not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less then 1.50 mtr below the normal ground level connected to galvanised earth strip of 32 x 6 mm dia by means of bolts nuts check nuts & washer of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified and testing on completion including the material and labour for :- (a) Excavation and earth work or drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 Type B-1 (c) Pre cast RCC cover with suitable handle 40mm thick in PCC 1:2:4 reinforced with welded steel wire fabric weighting not less than 1.87 Kg/sqmm (d) Funnel with watering pipe of GI 20mm nominal bore medium grade and copper lugs etc all as specified. (e) 15mm nominal bore meduim grade GI protec-tion pipe upto 7.50 metre long for protection of earthing lead. (f) Requisite quantity of charcoal and common salt (g) Connection to earthing test point and testing on completion.
Desert cooler (steel body) ISI marked with Zinc coating electric driven (single phase), having nominal air flow capacity of 4000 cum per hour (or nearest size) including following items/ work including and installation & testing completed all as specified and directed :- (i) All internal surfaces painted with water resistant paint to IS-9862. (ii) Steel sheet of sump tank to be 1.00 mm thickness, GI sheet of body thickness of 0.8mm (iii) Fan size 300-500mm sweep and Fan motor 1400 RPM (iv) Submersible pump to be IS : 11951 (v) Stand for mounted of desert cooler (sutable size) (vi) GI Air Diverter grill 2" size to be provided. (vii) Condenser 4MFD, 230 V AC to be provided. (viii) Best quality of wood wool to be provided and GI wire mesh 15x15mm aperture of suitable gauge also to be provided. Make : Bluestar/Usha/ Bajaj
Junction box of size 30cmx25cm on the pole or wall fabricated out of 3 mm thick MS sheet and angle iron (50x50x6mm) frame complete with openable shutters having proper locking arrangement and bolted, spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer including copper bus bar (4 Nos) of size 25x3 mm of suitable length mounted on suitable insulators including one No of MCB SPN 10 Amps complete all as specified and directed.
Feeder pillar box factory made of suitable size weather/verming proof outdoor type from CPRI approved panel Board made out of 3 mm thick CRCA sheet duly powder coated paint with inner shutter & outer double door with locking arrangement both side openable on 30mmx30mmx3mm MS angle iron frame fixed 45cm high from ground level & 30cm below the ground grounted in & incl PCC 1:3:6 type C1 (using 20mm graded stone agg) including necessay outgoing cable connections, cable glands, lugs & cable termination connector strip, name plate and consisting the following accessories. Make :- L&T/Indioasian/C&S/Hevells. a) Outgoing MCCB 100 Amps 4 poles 415 Volt -01 Nos breaking cap 25 KA with copper busbar capacity 150A rated (RYB and neutral colour coding) all as specified and directed.
HDPE Double Wall Corrugated pipe 3" dia for LT Cable protection fixed, complete all as specified and directed.
HDPE Double Wall Corrugated pipe 2" dia for LT Cable protection fixed, complete all as specified and directed.
Dismantling of unserviceable ACSR conductor any size including binding with copper / aluminium binding wire to overhead conductor and removing from site complete all as specified and directed.
Taking down GI guarding cradle complete all as specified and directed.
Dismantling of unserviceable existing cross arms of MS channel or angle sections etc from 2 pole structure / 4 pole structure of any size complete all as specified and directed.
Dismantling of existing pin /shackle / loop / disc / HT/LT insulator etc from Single/ 2 pole structure of any size complete all as specified and directed.
Dismantling and removing existing damaged/ unserviceable PCC of poles any size including excavation and earth work, demolition of PCC and removing from site complete all as specified and directed.
JANARDHANANDSONS
M/S H.N.ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .