P.S. to 01 No. 05 HP New Permanent Irrigation Pump Connection to Shri Tulsiram S/o Shri Ramcharan at Village Silari under Gurra D/c. of O and M Dn. Itarsi.
2020_MKVVC_75410_1
EE/STC/Works/19-20/47 Date 17.01.2020
Open Tender
Electrical Works
Turn-key
30 days
Itarsi
Please refer Tender documents.
11 documents required · 11 mandatory
₹112
R.A.O A.U. (O and M) MPMKVV Co.Ltd., Hoshangabad
₹2,500
Hoshangabad
7 Jul 2020
18 Jan 2020
29 Jan 2020
18 Jan 2020
28 Jan 2020
18 Jan 2020
25 Jan 2020
Erection, and Commissioning of DTR 25 KVA 11/.04 KV BIS Certified LEVEL-II
Stringing of AAAC Conductor Rabbit with 3% Sag with necessary clamps made of aluminium T-1f and necessay jointings sleeves, binding wires etc. complete in all respect.
Erection, and Commissioning of Three Phase Electronic Meter 10-40 amp with data downloading facility
Erection and Commissioning of 11 KV Polymer Pin Insulator
Supply, Erection and Commissioning of XLPE 1 core Unarmoured 35 sq. mm Aluminum Conductor 1100 volts
Supply and Erection of 11 KV D.O Fuse unit Polymer Type
Supply and erection of 11 KV Composite Polymer Disc Insulator
Supply and erection of 11 KV Strain H/w (T&C Type) fitting
Supply and Erection for Jointing sleeves suitable for Raccoon (80 Sq. mm Al. Eq.)
Supply and Erection for Aluminium binding wire and tape
Supply and Erection of 140 Kg. 8 Mtrs. Long PCC Poles
Supply and erection of DC Cross Arm made of 100x50x6 mm duly painted with double coat of Red Oxide and Al.Paint MS Chanel suitable for 8 feet centre D.P, suitable for H-Beam and DTR DP (Painting with Paint to be included in erection charge)
Supply, Erection, and Commissioning of Transformer Belting with 50x50x6mm angle with cross fixing channel duly painted with double coat of Red Oxide and Al.Paint, with all necessary clamps, MS.nuts & bolts etc.(Painting with Paint to be included in erection charge)
Supply, Erection, and Commissioning DO Mounting Channel 75x40x6 mm
Supply and erection of Transformer Mounting Channel made of 100x50x6 mm channel duly painted with double coat of Red Oxide and Al.Paint, with all necessary clamps, MS.nuts & bolts etc.(Painting with Paint to be included in erection charge)
Supply and erection of Stone Block/ Pre Cast Block for base padding (450x450x75 mm)
Supply and Erection of Back Clamp Suitable for 140 Kg. PCC Pole
Supply and Erection of Clamp for 140 Kg. PCC Pole MS Flat 50x6mm
Supply and Erection of 8' center DP Bracing support (2.4 Mtr.) angle of 65x65x6 mm duly painted with double coat of Red Oxide and Al.Paint for 33 KV and 11 KV sides(Painting with Paint to be included in erection charge)
Supply and Erection of 11 KV Polymer Lightening Arrester Station type
Supply and Erection for BI-Metalic Clamp Distribution transformer bushing
Supply and Erection for BI-Metalic Clamp suitable for 12mm dia stud and 80sqmm
Supply and erection of 11 KV V-Cross Arm made of MS Angle65x65x6 mm with back clamps 65x8 mm Flat duly painted with double coat of Red Oxide and Al.Paint, with all necessary clamps, MS.nuts & bolts etc.(Painting with Paint to be included in erection charge)
Supply and erection of 11 KV Top Clamp made of MS Angle 5x65x6 mm with back clamps 65x8 mm Flat duly painted with double coat of Red Oxide and Al.Paint, with all necessary clamps, MS.nuts & bolts etc.(Painting with Paint to be included in erection charge)
Supply and erection of Earthing Coil of 115 turns of 50 MM dia & 2.5 mm Lead of 4.0 mm GI wire
Supply and erection of Earthing Set ( DTR Earthing) as per Circular No. 1516 Dt. 17.03.08
Supply and Erection Back filling of poles with boulders
Supply and fixing of 11 KV Enameled Caution Board (Danger Board) as per specifications
Supply and erection of Anti-Climbing Devices 3.5 Kg Barbed wire for per Pole
Providing and erection of MS Nut Bolt of various sizes as per requirement
Supply and Erection of Concreting of Structure and Foundation (1:3:6) for base padding of pole @ 0.05 cmt per pole, 0.65 cmt per Pole, 0.65 cmt per Rail Pole, Pole RSJ,0 .3 cmt per stay for 20 mm and 0.2 cmt per stay16 mmas specified in technical specifications and as per requirement.
Supply and erection of Stay Insulator 90x65 mm
Supply and erection of LT Distribution box with Isolator & HRC fuse - 63 KVA DTR (200A & 6 SP of 60A)
Supply and erection of DLMS Compliant Category "C2" LT Three phase meter box,GSM,GPRS modem
Supply and erection of Earthing of PCC Pole 4.00 mm 8 SWG G.I. Wire 0.8 Kg. Per Pole
Supply and erection of Stay Set complete with 16mm dia. stay rod, A&B type anchor plate, thimble, turn buckles MS nuts & bolts and stay wire 7/ 3.15mm (5.5 Kg stay wire per stay set), Guy Insulator, clamps 65x8 mm Flat etc. by digging a suitable size pit in all types of soil/ rock and cement
Supply and erection of Stay Wire 7/3.15 mm.(7/10 SWG)
YATI TRADERS
SHRI MANGAL ELECTRICAL ENGINEERING
SURENDRA SINGH
SHEETAL KUMAR SHARMA
AGRAWAL ENGINEER AND CONTRACTORS
SHIVAM TRADERS
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .