Tender Value
₹65 L
EMD Value
₹1.2 L
Closing Date
22 Dec 2022, 6:00 pmClosed
Col Sharath Ravindran CWE
HQ CWE (AF) Chakeri Pin-208008
SPECIAL REPAIR TO DOORS AND PLENUM AIR-CIRCULATION SYSTEM OF PAINTING BAY (H NO 18) OF AFS KANPUR
2022_MES_542872_5
CA NO.CWE(AF)/CHK/EM/T-19 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) E/M Chakeri
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (AF) E/M Chakeri
₹1.2 L
12 Jan 2023
6 Dec 2022
24 Dec 2022
6 Dec 2022
22 Dec 2022
8 Dec 2022
Amount
(A) AIR CIRCULATION SYSTEM M&L dismantling and disconnecting of old galvanized steel filter mounting net and unserviceable wood pads from existing location to replace by another fabricated filter mountings and unserviceable filter complete as directed & specified by Engineer-in-charge.
M&L in repair for fabrication of MS angle iron frame structure of size 6M x2.6M with equal angle of size 25x25x3mm welded in frame structure partitions of size 1.0Mx0.45M to hold pre filter & secondary filter of 20 micron to facilitate fixing & removing during cleaning & whenever required. The frame structure shall be mounted carefully at the suction window/ side of paint shop by mean of grouting on walls complete all as specified & directed by Engineer-in-charge.
M&L in repair for fabrication of MS angle iron frame structure of size 11.6Mx2.1M with equal angle of size 50x50x3mm welded in frame structure partitions of size 0.95Mx 0.65M to hold pre filter of 10 micron to facilitate fixing & removing during cleaning & whenever required. The frame structure shall be mounted carefully at the suction window/ side of paint shop by mean of grouting on roof complete all as specified & directed by Engineer-in-charge.
S&F in repair for 50 mm thick washable type pre-filters of size 1.0m x 0.45m with filter element made out of synthetic non-woven media supported by HDPE mesh on both side including stitching in diamond pattern complete including frame, suitable for efficiency 90% down to 10 micron EU-3 Type complete with mounting frame work complete all as specified & directed by Engineer-in-charge.
S&F in repair for 50 mm thick washable type pre-filters of size 0.95 x 0.65m with filter element made out of synthetic non-woven media supported by HDPE mesh on both side including stitching in diamond pattern complete including frame, suitable for efficiency 90% down to 10 micron EU-3 Type complete with mounting frame work complete all as specified & directed by Engineer-in-charge.
S&F in repair for secondary dry type cleanable and easily maintainable air filter supported by GI wire and folder to form accordion plate having an efficiency of 99% down to 5 micron EU-5 type complete with mounting frame works complete all as specified & directed by Engineer-in-charge.
M & L for wood wool pads 15mm thick made out of chicken wire mesh filled with fine quality wood wool & stitched with GI wire for evaporative plant complete all as specified & directed by Engineer-in-charge.
S&F in repair for 4mm dia galvanized steel wire mesh of size 150x100mm, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling complete all as specified & directed by Engineer-in-charge.
Dismantling of existing air washer system of paint shop, removing the existing header nozzle, air filter and all connected items and cleaning of UG sump of capacity 1000 Gallons, removing sludge/sand/dirt by means of manual/sludge, cleaning the sump with bleached water and washing with sodium Hypo chloride liquid, drying and applying one coat of lime wash internally including testing complete all as specified and as directed.
(B) SPRINKLER SYSTEM M&L in repair for 300 mm dia M S ERW pipes 'heavy grade' suitable for spray system in double layer with all fittings laid in floors or fixed to walls and ceilings etc and to accommodate 48 Nos brass nozzle to sprink the water primer and applying one coat synthetic enamel blue shade paint over a coat of red oxide all as specified and directed. (Note: Brass nozzle shall be paid seperately and repective items).
Supply only factory made brass nozzle of dia 20mm fixed with header section including all fittings and fixture complete as per sample & as directed by Engineer-in-charge.
M&L drilling, machining, threading holes 48 Nos at header section of MS pipe 300 mm dia to accommodate/screw the nozzle on the entire section of header including fixing of nozzle complete with all accessories, fitting & fixture complete all as directed by Engr-in-charge.
M&L in repair for fabrication of frame structure of size 4.5x2.4m consisted of MS angle iron of size 50mmx50mmx5mm thick for housing GI sheet 1.5mm thick louvers duly V shaped and welded with frame notch at both ends to protect splashing of sprinkled water on blowers and applying two coat of synthetic enamel blue shade paint over a coat of red oxide primer on exposed surfaces complete all as specified and directed.
Supply, installation, testing & commissioning of centrifugal pump sets factory assembled & tested for rated efficiency complete with motor & common base frame, coupling guard etc. for re-circulation of condensed water from under ground sump to water spray system. The pumps shall be suitable for operation on 415 ± 10% Volts, 50 Hz, 3 Phase AC power supply all as specified and directed Note: Old unserviceable pump retrieved shall be department property & deposited to MES yard. The pump characteristic shall be as follows: (a) Water quantity - 523 US GPM (b) Static Head - 22 metre (c) Impeller - Cast iron type (d) RPM - 1500
Supply, installation, test & commissioning of centrifugal pump sets factory assembled & tested for rated efficiency complete with motor & common base frame, coupling guard etc. for re-circulation of condensed water from under ground sump to water spray system. The pumps shall be suitable for operation on 210 ± 10% Volts, 50 Hz, single Phase AC power supply all as specified and directed Note: Old unserviceable pump retrieved shall be department property & deposited to MES yard. The pump characteristic shall be as follows: (a) Water quantity - 150 US GPM (b) Static Head - 10 metre (c) Impeller - Cast iron type (d) RPM - 1500 (Note for item No 15 & 16: (i) Warranty/ guarantee of centrifugal pumps set for 05 years shall be kept on record before making payment to contractor) (ii) Old U/S pumps retrieved shall be kept on record/ ledger book and necessary RV attached along with payment of RAR/ Final bill).
Supply, laying, testing and commissioning of GI 'heavy grade ' water pipe of size 50 mm dia (Bore) with complete fittings such as bends, tees, elbows, reducers, flanges, special fittings, etc. including taking down old one complete all as specified and directed (Make :-TATA / Jindal / Prakash /Zenith or equivalent as approved by GE).
All as per srl item No 16.00 above but of size 40mm dia (Bore) complete all as specified and as directed
All as per srl item No 16.00 above but of size 25mm dia (Bore) complete all as specified and as directed
Supply and laying of MS Pipes of sizes 100mm dia (Bore) heavy grade with all fittings laid in floors or fixed to walls and ceilings etc including taking down old one complete all as specified and directed
Supply and laying of MS Pipes of sizes 150mm dia (Bore) heavy grade with all fittings laid in floors or fixed to walls and ceilings etc including taking down old one complete all as specified and directed
S&F in repair for Y- Strainers Cast Iron body & Rating of PN-1.0 of size 150mm dia complete all as specified and directed. (Make: Trishul/ Leader/ Emerald or equivalent as approved by GE)
S&F in repair for Cast Iron body 'Non return valve' of Rating PN -1.6 of size 150mm dia complete all as specified and directed. (Make :-Advance/Castle / Intervalve /SAAPL or equivalent as approved by GE).
S&F in repair for Butterfly valves Cast Iron body, Wafer type integrally moulded close end body construction with Hand liver operated and rating of PN-1.6 of size 150mm dia complete all as specified and directed. (Make :-Advance/Castle / Intervalve /SAAPL or equivalent as approved by GE)
S&F in repair for Burden Type Pressure Gauges 4" Dia 0-14 kgs rating stainless steel or CP brass stem complete with Globe valves confirming to IS - 3624 complete all as specified and directed. (Make :- Feibig/Waree/ H- Guru or equivalent as approved by GE)
S&F in repair for siphon (as per sample) in water line including cutting and welding of new socket/adopter complete all as specified and as directed.
S&F in repair for V belt C-156 suitable for blower complete all as specified and directed. (Make :- Micro/Navyug/Omfa rubbers Pvt Ltd/FENNER or equivalent as approved by GE)
S&F in repair for V belt C-180 suitable for blower complete all as specified and directed. (Make :- Micro/Navyug/Omfa rubbers Pvt Ltd/FENNER or equivalent as approved by GE)
S&F in repair for Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe of size 50mm complete all as specified and directed.
S&F in repair for Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe of size 40mm complete all as specified and directed.
S&F in repair for Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe of size 25mm complete all as specified and directed.
S&F in repair for 25 mm bore PTMT PVC float valve high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed. (Make :-Leader/Bombay metal and alloy Co
Supply, assembly and erection of GI sheet of thickness 18 Gauge with TDF flange rectangular/square duct made out of 'L' shaped hollow profile, duly factory boxed, incl all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc including taking down old sheet complete all as specified and directed.
All as per item No 32.00 above but of size 20 gauge thickness.
Supply and laying of thermal insulation of duct with 19 mm thick nitrile rubber sheet insulation having density 50 kg/cum and fixing with adhesive as per the recommendation of the manufacturer complete all as specified and directed.
S&F in repair for mild steel frame work of GI duct including MS rod as fastener, MS angle iron nut bolts and washers including welding and grouting work etc fastener & MS angle iron cut to requires shape & size for necessary support complete all as specified and as directed by Engineer in charge.
S&F in repair for air grills with vertical and horizontal adjustable louvers and volume control multi louvers dampers that shall be key operated from the front of the grill. Grill shall be MS construction of duly enamel painted complete with nut, bolts, gasket ete as per site requirement and as directed.
S&F of flexible canvass Connection for duct including zip superior quality complete all as specified and directed
M&L for matching alignment of blower shaft/pully to avoid fluctuation & vibration during rotation by checking properly and rectifying the cause of misalignment all specified and directed by Engr-in-Charge (Note: The cost of shaft bearing and transporting of shaft/fully to civil workshop and machining of shaft/pully if required for alignment to be included in quoted rate.)
Disconnecting electric motor, transporting to workshop and M&L for opening of motor, cutting/removing old burnt winding coils, cleaning filling the stator slots and rewinding of electric Induction motor upto 30 HP including of any make & or blower motor with suitable gauge of super enameled copper conductor with fiber cloth/PVC insulated winding paper, superior quality varnishing, servicing of ball bearings replacing connection terminal plate of motor and applying two coats of synthetic enamel spray paint to exterior surface of electric motor , suitable main connections from coil to terminal box, necessary mechanical works for shaft/bearing housing, preparing and inserting coils running/starting winding, interconnecting, fixing, soldering, jointing, heating, drying up coils, connection at site, after reinstallation to and fro transportation, testing at site, complete all specified and as directed. (Make of winding wire:- Veer Industries/ Devilal/ICC or equivalent as approved by GE)
All as per srl item No 39.00 above but 40 HP electric motor induction complete all as specified and as directed
All as per srl item No 39.00 above but 60 HP electric motor induction complete all as specified and as directed
S&F in repair for factory manufactured powder coated force draught ventilation axial flow type diffuser with axial flow fan with blades having aerofoil shape mounted on hub and connected to GI insulated duct complete with all accessories, fitting & fixture all as specified and directed.
Excavation in trenches not exceeding 1.50 m wide and not exceeding 1.50 m in depth and getting out in soft/loose soil for laying of cable , pole foundation, stay, laying of pipe etc complete all as specified and directed.
M&L PCC 1:3:6 type C-2 ( using 40mm graded crushed stone aggregate) as in foundation of poles/coping, stay etc complete all as specified and directed.
Returning filling in, including spreading ,leveling ,watering and well ramming in layers not exc 25 cm complete all as specified.
Supply and fixing of sand (free from vegetation and dust) for cushioning to under ground cables with a layer of 8 cm before laying the cable and 15 cm after laying the cable complete all as specified. (Note: Punned thickness of sand will be measured and paid).
M&L for brick protection with brick length equal to length of brick as mechanical protection to cable with well brunt sub class 'B' bricks laid complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.50 m above the starting point complete all as specified and directed.
Supply, laying and testing of LT XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) of 1100 Volts grade with stranded aluminum conductor of size 400 sq mm 3½ core including taking down old cable complete all as specified & directed.
Supply, laying and testing of LT XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) of 1100 Volts grade with stranded aluminum conductor of size 10 sq mm 4 core including taking down old cable complete all as specified & directed.
Supply, laying and testing of LT XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) of 1100 Volts grade with stranded aluminum conductor of size 16 sq mm 4 core including taking down old cable complete all as specified & directed.
Supply, laying and testing of XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) of 1100 Volts grade with stranded aluminum conductor of size 25 sq mm 3½ core including taking down old cable complete all as specified & directed.
Supply, laying and testing of LT XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) of 1100 Volts grade with stranded aluminum conductor of size 35 sq mm 3½ core including taking down old cable complete all as specified & directed.
Supply, laying and testing of LT XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminum conductor of size 70 sq mm 3½ core including taking down old cable complete all as specified & directed. (Note for item No 50 to 55: (i) Excavation and earth work, sand cushioning, brick protection etc shall be measured and under respective item. (ii) Cost of lugs and connecting plate, roof indicator, danger notice plate etc shall be deemed included in quoted unit rate.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminum conductor served with an inner sheathing of PVC tape overall PVC sheathed 4 sq. mm 3 core nominal cross section in for motor pump of 2 HP including taking down old cable complete all as specified & directed.
APFC Panel Dismantling/taking down old APFC panel and Supply, installation, testing and commissioning of APFC panel of cap 125 KVAR manufactured with following feature on highly precise modern amada CNC machine (a) 11 tank process for corrosion proof powder coating (b) Ergonomic, compact and robust design (c) Designed with Fully copper conductor (d) Super Heavy Duty capacitor power capacitor for long life (e) Advance C-MOS technology based micro processor relay for intelligent power factor control (f) Air core reactor for extra safety from inrush current (High currents) (g) Provision of top and bottom cable entry (h) Automatic temp. control through fans and louvers in panel (j) Double side earthing connection (k) Ref. Standard: IEC 61921/ IS 8623 / IS 16636 /IEC 61439 or latest revision available. Principle Operation (a) To continuously sense and monitor the load conditions by the use of the external CT (whose output is fed to the control relay). (b) To automatically switch ON and switch OFF relevant capacitor steps to ensure consistent power factor. (c) To ensure easy user interface for enabling reliable understanding of system operation, such as display of real time power factor, number of switching operations carried out etc. (d) To protect against any electrical faults in a manner that will ensure safe isolation of the power factor correction equipment.
S&F in repair for GI slotted cable tray 150 x 50MM width , 1.6 mm thickness width including necessary supports and frame work complete all as specified and as directed by Engineer-in-charge.
S&F in repair for GI slotted cable tray 300 x 50mm width , 1.6 mm thickness including necessary supports and frame work complete all as specified and as directed by Engineer-in-charge.
M & L in repair for earthing complete with Galvanized steel earth plate 600 x 600 x 6.0 mm buried directly in ground (earth pit not less then 2.25 Mtr deep below ground level) with top edge of the plate not less then 1.5 Mtr below normal ground level connected to GI strip of size 32x6 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel including excavation and earth work, GI pipe light grade 40 mm bore for protection of GI wire /strip from earth electrode to and including the earth test point of gun metal or phosphorus bronze size of size 75 X 75 X 75mm drilled and screwed including, 3 Nos, 8mm dia 25mm long hexagonal head screw, supplying and laying charcoal dust, common salt, PCC 1:3:6 type CI (using 20 mm graded stone aggregate) as in chamber and MS angle iron frame 40 x 40 x 3mm and RCC cover 40 mm thick 1:2:4 type B1 (using 20 mm graded stone aggregate) reinforced with 8 mm dia. TMT bars @ 75mm c/c both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified and directed. (Note: Excavation earth work shall be deemed included in quoted unit rate. (ii) Length of GI strip upto 7.5RM from test point shall be deemed included in quoted unit rate. Earthing strip beyond 7.5RM shall be measured and paid seperately under respective items).
M & L in repair for earthing complete with Galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of the plate not less then 1.5 Mtr below normal ground level connected to GI earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel incl excavation and earth work,PCC 1:3:6 type C-1 chamber with RCC cover 1:2:4 type B0 40mm thick, reinforced with 8 mm dia TMT bar, 3 Nos both way,15mm dia light grade GI protection pipe, funnel with wire mesh watering GI pipe of 20mm dia light grade and lugs including charcoal dust, common salt, and testing etc. all as shown in electrical plate No. 3 of SSR Part I complete all as specified & directed. (Note: (i) Earthing lead and protection pipe upto 7.5 meter length shall be deemed to be included in the quoted unit rate . Earthing lead beyond 7.5 meter shall be measured and paid separately. (ii) Excavation and earth work shall be deemed included in quoted unit rate).
M&L in repair for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI strip 32x6mm complete all as specified.
M&L in repair for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI wire 4mm dia complete all as specifie.
S & F in reapir for rotational moulded polyethylene water storage tanks of cap 2000 Ltr (cylindrical vertical with closed top) triple layered including lid cover, hoisted and fixed in position complete all as specified.
Electrical Main LT Panel Disconnecting, taking down old panel and Supply, installation, testing and commissioning of the following Indoor type LT panel suitable to be mounted on the floor/ cable duct/ wall as per site requirement using MS channel frame work, with cable entry from bottom/ top as per drawing coordination by GE with removable gland plates with required knock-outs for incoming and outgoing cables. Panel shall be fabricated out of CRCA sheet 2 mm thick steel folded and braced as necessary to provide a rigid support for all components, totally enclosed and degree of protection shall not be less than IP-54, multi-tier cubicle type formation with front hinged lockable doors for the individual feeders/ compartments, preparation of surface and treatment by seven tank process, powder coated with approved colour for not less than 50 microns and all doors and covers shall be fully gasket using good quality EPDM gasket and /or rubber strips, and to provide good quality locking arrangement, durable door opening & closing mechanism and digital volt & Amp meter and all as per approved from CPRI including providing danger notice plate with significance of 'Skull & boons marked with phosphorus paint etc and following accessories:-
(a) Copper bus bars for three phases and neutral, bus bar insulators, heat shrinkable PVC sleeves etc., with necessary interconnections as specified in Technical specifications for electrical & mechanical works, comprising of following switchgear and accessories complete in all respects.
(ii) 02 Nos (Panel No 2 & 4 200 Amp, 25KA, 415V TP+NL MCCB with adjustable thermal settings, overload and short circuit release including door interlocking device, front operating handle , ON and OFF indication of LED module, bus bar extension for connecting cables etc. complete in all respects complete complete. (iii) 01 Nos for panel No 3 250 Amp., 25KA, 415V TP+NL MCCB with adjustable thermal settings, overload and short circuit release including door interlocking device, front operating handle , ON and OFF indication of LED module, bus bar extension for connecting cables etc. complete in all respects. complete.
Disconnecting, taking down old panel and Supply, installation, testing and commissioning factory made Indoor type LT panel No 1 for blower C 1 & 2 suitable to be mounted on the wall as per site requirement using M.S channel frame work, with cable entry from bottom/top as per drawing coordination by EIC with removable gland plates with required knock-outs for incoming and outgoing cables. Panel shall be fabricated out of CRCA sheet 1.6 mm thick steel folded and braced as necessary to provide a rigid support for all components, totally enclosed and degree of protection shall not be less than IP-54, multi-tier cubicle type formation with front hinged lockable doors for the individual feeders/compartments, preparation of surface and treatment by seven tank process, powder coated with approved colour for not less than 50 microns and all doors and covers shall be fully gasket using good quality EPDM gasket and /or rubber strips, and to provide good quality locking arrangement, durable door opening & closing mechanism, aluminum bus bars of 1.6 times capacity of main for three phases and neutral, bus bar insulators, heat shrinkable PVC sleeves and including providing of danger notice plate with significance of 'Skull & boones' marked with phosphorus paint etc, with necessary interconnections as specified and directed by Engr-in-charge including comprising of following switchgear and accessories complete in all respects:-
Outgoing :(i) MCCB four pole 63 Amps 415 Volts, 16K breaking capacity with fixed thermal setting for Evaporative blower C 1& 2 - 02 Nos (ii) The star delta starter AC , 3 phase, 415 V suitable for blower motor of cap 40 HP , shall be with single phase preventer, electronic timer, with sufficient auxiliary contacts for remote ON/OFF indication lamps, bi-metallic thermal overload relay of suitable size current rating, ON/OFF push buttons suitably wired and interconnected with 6.0 Sq.mm single stranded PVC copper wire, etc, complete in all respects.
(iii) MCB TPN 6 amps 415 Volts, 10K breaking capacity for water circulation pump - 02 Nos. (iv) The DOL delta starter AC , 3 phase, 415 V suitable for water circulation monoblock pump of cap 2 HP, shall be with single phase preventer, electronic timer, with sufficient auxiliary contacts for remote ON/OFF indication lamps, bi-metallic thermal overload relay of suitable size current rating, ON/OFF push buttons suitably wired and interconnected with 6.0 Sq.mm single stranded PVC copper wire, etc, complete in all respects complete all as specified & directed.
Disconnecting, taking down old panel and Supply, installation, testing and commissioning of factory made Indoor type LT panel No 2 for blower C 5 suitable to be mounted on the wall as per site requirement using M.S channel frame work, with cable entry from bottom/top as per drawing coordination by EIC with removable gland plates with required knock-outs for incoming and outgoing cables. Panel shall be fabricated out of CRCA sheet 1.6 mm thick steel folded and braced as necessary to provide a rigid support for all components, totally enclosed and degree of protection shall not be less than IP-54, multi-tier cubicle type formation with front hinged lockable doors for the individual feeders/compartments, preparation of surface and treatment by seven tank process, powder coated with approved colour for not less than 50 microns and all doors and covers shall be fully gasket using good quality EPDM gasket and /or rubber strips, and to provide good quality locking arrangement, durable door opening & closing mechanism, aluminum bus bars of 1.6 times capacity of main for three phases and neutral, bus bar insulators, heat shrinkable PVC sleeves and including providing of danger notice plate with significance of 'Skull & boones' marked with phosphorus paint etc, with necessary interconnections as specified and directed by Engr-in-charge including comprising of following switchgear and accessories complete in all respects:-
Outgoing :(i) MCCB four pole 100 Amps 415 Volts, 16K breaking capacity with fixed thermal setting for Evaporative blower C 5 - 01 Nos (ii) The star delta starter AC , 3 phase, 415 V suitable for blower motor of cap 40 HP , shall be with single phase preventer, electronic timer, with sufficient auxiliary contacts for remote ON/OFF indication lamps, bi-metallic thermal overload relay of suitable size current rating, ON/OFF push buttons suitably wired and interconnected with 6.0 Sq.mm single stranded PVC copper wire, etc, complete in all respects.
Outgoing :(iii) MCCB four pole 63 amps 415 Volts, 16K breaking capacity for water circulation pump - 02 Nos (iv) The DOL star delta starter AC , 3 phase, 415 V suitable for water circulation monoblock pump of cap 20 HP, shall be with single phase preventer, electronic timer, with sufficient auxiliary contacts for remote ON/OFF indication lamps, bi-metallic thermal overload relay of suitable size current rating, ON/OFF push buttons suitably wired and interconnected with 6.0 Sq.mm single stranded PVC copper wire, etc, complete in all respects complete all as specified.
Disconnecting, taking down old panel and Supply, installation, testing and commissioning of factory made Indoor type LT panel No 3 for blower C 3 & 4 suitable to be mounted on the wall as per site requirement using M.S channel frame work, with cable entry from bottom/top as per drawing coordination by EIC with removable gland plates with required knock-outs for incoming and outgoing cables. Panel shall be fabricated out of CRCA sheet 1.6 mm thick steel folded and braced as necessary to provide a rigid support for all components, totally enclosed and degree of protection shall not be less than IP-54, multi-tier cubicle type formation with front hinged lockable doors for the individual feeders/compartments, preparation of surface and treatment by seven tank process, powder coated with approved colour for not less than 50 microns and all doors and covers shall be fully gasket using good quality EPDM gasket and /or rubber strips, and to provide good quality locking arrangement, durable door opening & closing mechanism, aluminum bus bars of 1.6 times capacity of main for three phases and neutral, bus bar insulators, heat shrinkable PVC sleeves and including providing of danger notice plate with significance of 'Skull & boones' marked with phosphorus paint etc, with necessary interconnections as specified and directed by Engr-in-charge including comprising of following switchgear and accessories complete in all respects:-
Outgoing :(i) MCCB four pole 63 Amps 415 Volts, 16K breaking capacity with fixed thermal setting for Evaporative blower C 3 & 4 - 02 Nos (ii) The star delta starter AC , 3 phase, 415 V suitable for blower motor of cap 60 HP , shall be with single phase preventer, electronic timer, with sufficient auxiliary contacts for remote ON/OFF indication lamps, bi-metallic thermal overload relay of suitable size current rating, ON/OFF push buttons suitably wired and interconnected with 6.0 Sq.mm single stranded PVC copper wire, etc, complete in all respects.
(iii) MCCB four pole 63 Amps 415 Volts, 16K breaking capacity with fixed thermal setting for water circulation pump - 02 Nos (iv) The DOL star delta starter AC , 3 phase, 415 V suitable for blower motor of cap 60 HP , shall be with single phase preventer, electronic timer, with sufficient auxiliary contacts for remote ON/OFF indication lamps, bi-metallic thermal overload relay of suitable size current rating, ON/OFF push buttons suitably wired and interconnected with 6.0 Sq.mm single stranded PVC copper wire, etc, complete in all respects complete all as specified & directed.
Disconnecting, taking down old panel and Supply, installation, testing and commissioning of factory made Indoor type LT panel No 5 for blower C 7 & 8 suitable to be mounted on the wall as per site requirement using M.S channel frame work, with cable entry from bottom/top as per drawing coordination by EIC with removable gland plates with required knock-outs for incoming and outgoing cables. Panel shall be fabricated out of CRCA sheet 1.6 mm thick steel folded and braced as necessary to provide a rigid support for all components, totally enclosed and degree of protection shall not be less than IP-54, multi-tier cubicle type formation with front hinged lockable doors for the individual feeders/compartments, preparation of surface and treatment by seven tank process, powder coated with approved colour for not less than 50 microns and all doors and covers shall be fully gasket using good quality EPDM gasket and /or rubber strips, and to provide good quality locking arrangement, durable door opening & closing mechanism, aluminum bus bars of 1.6 times capacity of main for three phases and neutral, bus bar insulators, heat shrinkable PVC sleeves and including providing of danger notice plate with significance of 'Skull & boones' marked with phosphorus paint etc, with necessary interconnections as specified and directed by Engr-in-charge including comprising of following switchgear and accessories complete in all respects:-
Outgoing :(i) MCCB four pole 63 Amps 415 Volts, 16K breaking capacity with fixed thermal setting for Evaporative blower C 7 & 8 - 02 Nos (ii) The star delta starter AC , 3 phase, 415 V suitable for blower motor of cap 60 HP , shall be with single phase preventer, electronic timer, with sufficient auxiliary contacts for remote ON/OFF indication lamps, bi-metallic thermal overload relay of suitable size current rating, ON/OFF push buttons suitably wired and interconnected with 6.0 Sq.mm single stranded PVC copper wire, etc, complete in all respects complete all as specified and directed.
S&F in reapir for LED light fighting of 30 W environmental friendly, energy saving long life corrosion resistant, vertical surface mounting pressure die-cast aluminum housing and control gear compartment well glass luminaries with high power LED as light source. (Make Havells cat part No STUPEWGP30WLED757SSYMTOPCGRY or equivalent make as per list of make Appx 'B' duly approved by GE).
S&F in repair for decorative ultra slim aluminum 36W LED lighting fixture with high lumen output, environmental friendly, energy efficient ready to use pack . Make Havells Ref cat part No LHEXACP7IN1W036 or equivalent make as per list of make Appx 'B' duly approved by GE).
(C) B&R Work Taking down Chowkats or frames, exc. 1.50 sqm but not exc. 4.00 sqm each (without taking off shutters from the frames), complete all as specified and as directed. (Note: The quoted unit rate deemed included cost of making good dismantled portion of wall (takes place during taking down to existing door/window) in cement mortar 1:3 or cement concrete 1:2:4 type B0-) as required at site).
S&F frame work as in doors or gates of angle or other section with gusset plates, braces, etc, complete, drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hignes or steel hanging door fittings (exclusive of steel sheeeting or other covring, running rails and guides) and hanging also fastening and fixing complete all as specified.
S&F frame work such as grill, grating, etc with ends of bars shoulderered and or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters walk says railings framework of water tanks and similar work conforming to Fe.290 Gde-E-165 complete all as specified.
S&F 1.60 mm Mild steel, plain, black sheet in wall cladding, steel gtes and similar work, cut to size, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angle etc as required complete all as specified.
M&L preparation of steel surfaces of any description exc 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, devetailedor welded complete all as specified and directed. .
M&L Brick work with old size of bricks subclass 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
M&L rendering 15mm thick in CM (1:4) on fair faces of bick work or concrete srfaces, finished even & smooth without using extra cement, complete all as specified and directed.
M&L preparation of new undecorated surfaces of walls and applying two coat of Oil Bound Distemper over a coat of primer with chalk whiting, complete all as specified and directed.
M&L for preparation of new undecorated surfaces of walls and applying two coat of cement based paint over a coat of primer, complete all as specified and directed.
M&L making funcational of existing hanger slioil shutter of any thickness by replacing ball bearing top and bottom completely, roller correcting /straitening of guide rail etc with and including necessary repairing mild steel sheet cladding and greasing for easing side guide rails (Area of shutter n.exc 6.60m x 8.30 = 55.28 Sqm each) complete all as specified and directed.
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F 4.8 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5Sqm in each pane complete all as specified and directed.
M/S MALHOTRA ENGINEERING WORKS
Bharat Sales Corporation
M/s R.V. Constructions
SAXENA BANDHU
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .