Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.8 LAccepted-AOC B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹46.8 L+₹4.9 L (11.8%)Rejected-Finance FIRDOUS ABAD BATMALOO SRINAGAR PIN 190004 J K | SRINAGAR | SRINAGAR | J K | 190004 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹47.3 L+₹5.5 L (13.1%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹48.7 L+₹6.9 L (16.4%)Rejected-Finance GUDSATHU BUDGAM KASHMIR 191111 J K | BUDGAM | BUDGAM | JAMMU AND KASHMIR | 191111 | L4 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | QAZI SONS L3 | SATISH AND CO L1 | JK BUILDERS AND ENGINEERS L4 | VEDA INFRASTRUCTURE L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing and commissioning of highly efficient outdoor type oil immersed naturally cooled (ONAN) type transformer copper wound type of capacity 400 KVA as per latest IS code conforming to IS-1180(Part-1) : 2014 or latest edition of the IS standard, Level-II with off load tap changer on primary side to vary secondary voltage within limits as per IS tapping range (+) 5% to (-)10% in steps of 2.5% for variation of HV including standard fittings and first filling of transformer oil as per IS 335 of 1980 with cooling system. The transformer shall be provided with cable termination box to terminate outdoor type termination of suitable size on HT side 11 KV & LT outdoor installations and double wound core type with cold rolled grain oriented silicon shell insulated and clamped to minimize vibrations and noise. The winding shall be of copper and shall be designed for full load current and withstand the thermal and electro magnetic stresses arising due to the through fault currrent vector group shall be DYn 11 including supply of all standard fittings/ fixtures and comprising of the followings all as specified and directed :-
(a) HT cable termination Box.
(b) LT cable termination Box.
(c) Rating and diagram plate.
(d) Earthing terminals with earthing symbol
(e) Lifting lugs.
(f) Oil level indicator with minimum and maximum level marking.
(g) Thermometer pocket with cap.
(h) Conventional Conservator with oil filling hole with cap and drain cum sampling valve.
(j) Air release device.
(k) Silica Gel breather.
(l) Off circuit tap changer with locking provision.
(m) Unidirectional Rollers.
(n) Radiators/ Fins and all (Epoxy painted).
(o) Danger Notice Board.
(p) Inspection hole.
(q) Pressure relief device. | 2 | Each | 22,99,000 ₹45,98,000 | 19,95,000 ₹39,90,000 Lowest | 24,00,000 ₹48,00,000 | 22,99,000 ₹45,98,000 |
| 2.00 | Disconnecting all the electrical connections from HT and LT side of unserviceable transformer of capacity upto 300 KVA i.e. Jumpers/ Cable from the cable end box or bushings & earthing terminal of the transformers including taking down, loading, unloading of transformer and deposit to MES store yard & including reinstallation, commissioning and testing complete all as specified and directed. | 2 | Each Job | 10,000 ₹20,000 | 44,500 ₹89,000 | 4,000 ₹8,000 | 500 ₹1,000 Lowest |
| 3.00 | M&L replacement of unserviceable earthing complete with galvanised steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanised iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, 40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit in cement concrete 1:3:6 with pit cover of size 30x30cm made of RCC 1:3:6 with suitable handle, angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, removal of surplus soil and returning filling in all as required at site including test point terminal made of gun metal or phosphorus bronze 75x75x25mm, drilled and screwed including 3 Nos, 8mm dia 25mm long hex. head screw complete fixed to wall all as specified in plate No 03 of SSR Part-I including testing on completion all as specified and directed. | 4 | Each Set | 7,000 ₹28,000 | 4,500 ₹18,000 | 4,000 ₹16,000 Lowest | 4,000 ₹16,000 Lowest |
| 4.00 | M&L replacement of unserviceable earthing complete with copper plate electrode 60cmx60xcmx3.15mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below level) with top edge of the plate not less than 1.5m below normal ground level, connected to and including earth lead of copper strip 20x3mm by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and excavation and earth work in any type of strata, PCC 1:3:6 type C-1 in chamber, precast RCC cover 50mm cover 50mm thick in cement concrete 1:2:4 type B-1, reinforced with welded steel wire fabric or XPM (Weight not less than 5 Kgs/Sqm) with cast iron frame, funnel with wire mesh, 20mm bore GI pipe medium grade watering pipe, lugs, 40mm bore GI pipe light grade protection pipe upto 7.5m with funnel and wiremesh, PCC pit 1:3:6 with pit in cement concrete cover of size 30x30cm made of RCC 1:3:6 with suitable handle, angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, removal of surplus soil and returning filling in all as required at site including test point terminal made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 Nos, 8mm dia 25mm long hex. head screw complete fixed to wall complete all as specified in plate No 3 of SSR PART-I | 4 | Each Set | 22,000 ₹88,000 | 22,000 ₹88,000 | 12,000 ₹48,000 Lowest | 16,000 ₹64,000 |
| 5.00Notes :- An amount of Rs. 2,000.00 on account of Credit Schedule for Schedule 'A' Part-II shall be deducted from total quoted amount of BOQ to arrive at the contract sum. | |||||||
Tender Value
₹47.5 L
EMD Value
₹94,905
Closing Date
14 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Cdr, HQ 134 Wks Engrs
HQ 134 WE C/o 56 APO PIN-914134
Provn of 400KVA transformer with connected works at pattan under AGE (I) CIF (K)
2025_MES_721100_1
134 WE-43(T)/2025-26
Open Tender
Civil Works - Others
Item Rate
180 days
AGE (I) CIF (K)
As per tender documents
8 documents required · 8 mandatory
₹500
AGE (I) CIF (K)
₹94,905
12 Sept 2025
18 Jul 2025
16 Aug 2025
18 Jul 2025
14 Aug 2025
31 Jul 2025
18 Jul 2025 - 25 Jul 2025
Amount
Supply, installation, testing and commissioning of highly efficient outdoor type oil immersed naturally cooled (ONAN) type transformer copper wound type of capacity 400 KVA as per latest IS code conforming to IS-1180(Part-1) : 2014 or latest edition of the IS standard, Level-II with off load tap changer on primary side to vary secondary voltage within limits as per IS tapping range (+) 5% to (-)10% in steps of 2.5% for variation of HV including standard fittings and first filling of transformer oil as per IS 335 of 1980 with cooling system. The transformer shall be provided with cable termination box to terminate outdoor type termination of suitable size on HT side 11 KV & LT outdoor installations and double wound core type with cold rolled grain oriented silicon shell insulated and clamped to minimize vibrations and noise. The winding shall be of copper and shall be designed for full load current and withstand the thermal and electro magnetic stresses arising due to the through fault currrent vector group shall be DYn 11 including supply of all standard fittings/ fixtures and comprising of the followings all as specified and directed :- (a) HT cable termination Box. (b) LT cable termination Box. (c) Rating and diagram plate. (d) Earthing terminals with earthing symbol (e) Lifting lugs. (f) Oil level indicator with minimum and maximum level marking. (g) Thermometer pocket with cap. (h) Conventional Conservator with oil filling hole with cap and drain cum sampling valve. (j) Air release device. (k) Silica Gel breather. (l) Off circuit tap changer with locking provision. (m) Unidirectional Rollers. (n) Radiators/ Fins and all (Epoxy painted). (o) Danger Notice Board. (p) Inspection hole. (q) Pressure relief device.
Disconnecting all the electrical connections from HT and LT side of unserviceable transformer of capacity upto 300 KVA i.e. Jumpers/ Cable from the cable end box or bushings & earthing terminal of the transformers including taking down, loading, unloading of transformer and deposit to MES store yard & including reinstallation, commissioning and testing complete all as specified and directed.
M&L replacement of unserviceable earthing complete with galvanised steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanised iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, 40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit in cement concrete 1:3:6 with pit cover of size 30x30cm made of RCC 1:3:6 with suitable handle, angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, removal of surplus soil and returning filling in all as required at site including test point terminal made of gun metal or phosphorus bronze 75x75x25mm, drilled and screwed including 3 Nos, 8mm dia 25mm long hex. head screw complete fixed to wall all as specified in plate No 03 of SSR Part-I including testing on completion all as specified and directed.
M&L replacement of unserviceable earthing complete with copper plate electrode 60cmx60xcmx3.15mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below level) with top edge of the plate not less than 1.5m below normal ground level, connected to and including earth lead of copper strip 20x3mm by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and excavation and earth work in any type of strata, PCC 1:3:6 type C-1 in chamber, precast RCC cover 50mm cover 50mm thick in cement concrete 1:2:4 type B-1, reinforced with welded steel wire fabric or XPM (Weight not less than 5 Kgs/Sqm) with cast iron frame, funnel with wire mesh, 20mm bore GI pipe medium grade watering pipe, lugs, 40mm bore GI pipe light grade protection pipe upto 7.5m with funnel and wiremesh, PCC pit 1:3:6 with pit in cement concrete cover of size 30x30cm made of RCC 1:3:6 with suitable handle, angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, removal of surplus soil and returning filling in all as required at site including test point terminal made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 Nos, 8mm dia 25mm long hex. head screw complete fixed to wall complete all as specified in plate No 3 of SSR PART-I
Notes :- An amount of Rs. 2,000.00 on account of Credit Schedule for Schedule 'A' Part-II shall be deducted from total quoted amount of BOQ to arrive at the contract sum.
VEDA INFRASTRUCTURE (BID ID -3393881)
QAZI SONS (BID ID -3384725)
JK BUILDERS AND ENGINEERS (BID ID -3392878)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .