Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 879 SHAHBAD BHOOR BAREILLY BHOOR BAREILLY BAREILLY BAREILLY UTTAR PRADESH 243001 | BAREILLY | UTTAR PRADESH | 243001 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical 402 STERLING APTS 5 4 33 DISTILLARY ROAD RANIGUNG SECUNDERABAD 500003 TELANGANA | SECUNDERABAD | SECUNDERABAD | TELANGANA | 500003 | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹2,000
Closing Date
13 Jun 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC BAREILLY
Superintending Engineer Electy. Transmission Circle Transmission Campus Near L.I.C. Office Rampur Garden, Bareilly
Providing and Fixing of Temperature Indicator and Oil Temperature Indicator for 40MVA Transformer alongwith other associated works at 132KV SAS Substation Ujhani under Electricity Transmission Division Budaun
2024_UPTCL_926095_1
E-Tender No. 01/ETC(B)/2024-25
Open Tender
Electrical Works
Item Wise
30 days
Budaun
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
SE ETC BAREILLY
₹2,000
12 Jul 2024
4 Jun 2024
14 Jun 2024
4 Jun 2024
13 Jun 2024
4 Jun 2024
Amount
Providing & Fixing of Temperature Indicator and Oil Temperature Indicator for 40MVA Transformer alongwith other associated works at 132KV SAS Substation Ujhani under Electricity Transmission Division Budaun, with all cost of men, misc. consumables, normal & special t&ps etc required to be arranged by agency for satisfactory completion of the Supply, with all due care of safety & precautions as per technical specifications and direction of the supervising engineer, as per details below :
Replacement of Oil Temperature Indicator alongwith its Repeater Dial Indicator as per sample provided (existing specifications : 02 Micro Switches, 10 Meter long Capillary Tube, Temperature Range 0DegC - 150DegC, Model No. 1002, Serial No : 07-2740/3 of Precimeasure Controls) installed on 40 MVA T/F I while ensuring the compatibility of replaced OTI during its replacement . The work includes providing and fixing of Oil Temperature Indicator for replacement with following specifications or any other equivalent : Model 1007H with 2 micro switches (Option 2, Contact rating 15A @ 250V AC, 5A @ 250V DC), 25 meters capillary length with builtin RTD Sensor, CCU and External Remote Indicator Model 2245H-T2 with 2 No's of 4-20mA DC output, Range 0-150 deg C, Auxiliary supply 90-260V AC/DC, Union 1/2" BSP Male. Remote Indicator Drg No. 8000-17/R2, As per O.A Drg No.3352/R1, Wiring Drg No.3336-P1, Sensing bulb Drg No. 1088/R1, Scheme Drg No. 6700-417/R2 of Precimeasure make or any other equivalent make while ensuring the adherance to above mentioned ratings and specifications set by the equivalent make company.
Replacement of Winding Temperature Indicator alongwith its Repeater Dial Indicator as per sample provided (existing specifications : 04 Micro Switches, 10 Meter long Capillary Tube, Temperature Range 0DegC - 150DegC, Model No. 1002, Serial No : 07-2741/1 of Precimeasure Controls) installed on 40 MVA T/F I while ensuring the compatibility of replaced WTI during its replacement . The work includes providing and fixing of Winding Temperature Indicator for replacement with following specifications or any other equivalent : Model 1007H with 4 micro switches (Option 2, Contact rating 15A @ 250V AC, 5A @ 250V DC), 25 meters capillary length with builtin RTD Sensor, CCU and External Remote Indicator Model 2245H-T2 with 2 No's of 4-20mA DC output, Range 0-150 deg C, Auxiliary supply 90-260V AC/DC, Union 1/2" BSP Male. Gradient 2A, 15 deg C. Remote Indicator Drg No. 8000-17/R2, As per O.A Drg No.3352/R1, Wiring Drg No.3336-P6, Sensing bulb Drg No. 1088/R1, Scheme Drg No. 6700-417/R2 of Precimeasure make or any other equivalent make while ensuring the adherance to above mentioned ratings and specifications set by the equivalent make company.
Work of removal of old and damaged Winding Temperature Indicator alongwith its Repeater Dial from Transformer Panel and RTCC panel by opening the nut of capillary tube and keeping all the other connections safe followed by installation of new Winding Temperature Indicator alongwith its External remote Indicator with all manpower, material, ferrules, lugs of any kind, cable glands and T&C etc required to be provided by the contractor at his own cost. The work to be carried out by the authorised sevice/commissioning engineer of the company whose OTI & WTI has been provided.
Work of removal of old and damaged Oil Temperature Indicator alongwith its Repeater Dial from Transformer Panel and RTCC panel by opening the nut of capillary tube and keeping all the other connections safe followed by installation of new Oil Temperature Indicator alongwith its External remote Indicator with all manpower , material, ferrules, lugs of any kind, cable glands and T&C etc required to be provided by the contractor at his own cost.The work to be carried out by the authorised sevice/commissioning engineer of the company whose OTI & WTI has been provided.
M/S INDRA ENTERPRISES
M/s. ADITYA TRADING CO., KM-383, RAIDOPUR OFFICERS COLONY, AZAMGARH, U.P.-276001.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .