Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC 3 4 JEEVAN DEEP BUILDING 10 PARLIAMENT STREET NEW DELHI 1 PH 011 43573493 9899713006 | ₹1.2 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹1.2 Cr+₹2 L (1.66%)Rejected-Finance 221 BISARIYA COMPLEX ZONE II M P NAGAR BHOPAL MADHYA PRADESH 462011 | BHOPAL | MADHYA PRADESH | 462011 | ₹1.2 Cr+₹2 L (1.66%) | L2 | Rejected-Finance NOT THE LOWEST BIDDER |
| 3 | L3₹1.3 Cr+₹10 L (8.32%)Rejected-Finance | ₹1.3 Cr+₹10 L (8.32%) | L3 | Rejected-Finance NOT THE LOWEST BIDDER |
| 4 | L4₹1.8 Cr+₹56 L (46.6%)Rejected-Finance | ₹1.8 Cr+₹56 L (46.6%) | L4 | Rejected-Finance NOT THE LOWEST BIDDER |
| 5 | L5₹2.2 Cr+₹98.0 L (81.5%)Rejected-Finance 53 VAISHAILI ENCLAVE SECTOR 9 INDIRA NAGAR LUCKNOW | LUCKNOW | ₹2.2 Cr+₹98.0 L (81.5%) | L5 | Rejected-Finance NOT THE LOWEST BIDDER |
Tender Value
₹2.2 Cr
EMD Value
₹4.4 L
Closing Date
1 Jun 2020, 6:00 pmClosed
AGM (EE)-II-IMU, RGB, New Delhi
AGM (EE)-II-IMU, C-Block, Room No.-148 AAI, RGB, New Delhi
Upgradation of Indoor Air Quality for safe operation of Central Air-Conditioning System during Spread of COVID-19 at Rajiv Gandhi Bhawan, Safdarjung Airport, Delhi
2020_AAI_48597_1
AAI/IMU/AGME(E)ENIT01/2020-21
Open Tender
Electrical Works
Tender cum Auction
30 days
Rajiv Gandhi Bhawan, New Delhi
Please refer Tender documents.
13 documents required · 13 mandatory
₹1,120
Airports Authority of India
₹4.4 L
22 Jul 2020
21 May 2020
5 Jun 2020
22 May 2020
1 Jun 2020
22 May 2020
22 May 2020 - 28 May 2020
Amount
Supply, Installation, Testing & commissioning of hybrid air purification system with central air cleaner to achieve the IAQ parmaters by reducing harmful pollutants i.e. particulate matter (PMx), PM 2.5, allergens, pollen, smoke, bacteria, pathogens virus, VOC's, odor etc. based on trap & kill technology. The unit shall be in a powder coated steel casing and self contained. Unit shall be BMS compatible. It should be a customized product as per the filter dimensions of AHUs. Unit shall be monobloc structured type specifically designed for integration in Return Air path to centrally capture and kill germs. It shall be three working principles. Unit shall be suitable for the air quantity similar to AHUs. It should have pre-filter, polarizer grid, e-filter, run hour meter, clogging indicator light for filters. CAC shall be suitable for operation on 220±10 % volts, 50 Hz,1 phase AC power supply. Pressure drop should not be more than 5mmWG. The e-filter/collector should be washable type . In filter assembly Activated carbon filters (Minimum 1 Carbon filter per 1000 CFM) to be provided for removal of TVOCs & CO. Pressure drop should not be more than 3mmWG. Job also includes dismantling of existing filters and transporting the same to AAI store within the quoted cost. Agency has to study local ambient air data and quality of air before proposing & finalizing air cleaner. Unit should be suitable to meet all IAQ parameters i.e. PM 2.5, PM-10 etc. as per ASHRAE/ANSI/ NEA & OSHA etc.
For 9500 CFM AHU
For 12,500 CFM AHU
For 10,500 CFM AHU
For 10,800 CFM AHU
For 13,500 CFM AHU
For 12,000 CFM AHU
For 7330 CFM AHU
For 13000 CFM AHU
For 12,300 CFM AHU
For 19294 CFM AHU
For 14,000 CFM AHU
For 17,000 CFM AHU
For 6,117 CFM Ceiling Suspended AHU
For 7059 CFM AHU
For 14,716 CFM AHU
For 10511 CFM AHU
For 16,000 CFM AHU
For 3000 CFM Ceiling Suspended AHU
For 1.5 TR Fan Coil Units
For 2.0 TR Fan Coil Units
For 2.5 TR Fan Coil Units
For 3.0 TR Fan Coil Units
For 2000 CFM Inline Fan
For 1000 CFM Inline Fan
Supply, installation , testing & Commissioning of AHU coil mounted UV system for maintaining Indoor Air Quality through coil microbe disinfection & cleaning without the need for regular chemical cleaning. UV modules should factory fabricated support. UV system supplied must be in strict conformity with the specifications.( tenderers are requested to see the technical specifications before quoting the rate)
For 9500 CFM AHU
For 12500 CFM AHU
For 10500 CFM AHU
For 10800 CFM AHU
For 13500 CFM AHU
For 12000 CFM AHU
For 7330 CFM AHU
For 13000 CFM AHU
For Ceiling Suspended AHU 3000 CFM
For 12300 CFM AHU
For 19294 CFM AHU
For 14000 CFM AHU
For 17000 CFM AHU
For Ceiling Suspended AHU 6117 CFM
For 7059 CFM AHU
For 14716 CFM AHU
For 10511 CFM AHU
For 16000 CFM AHU
For 1.5 TR Fan Coil Units
For 2.0 TR Fan Coil Units
For 2.5 TR Fan Coil Units
For 3.0 TR Fan Coil Units
Supply, Installation, Testing & Commissioning of circular/rectangular inline fans with EC Motor , complete with sheet metal casing, direct driven centrifugal fan, motor with proper protection and inspection door as per the specifications. Fan should be suitable for operation on 415±10% volts, 50 Hz, three phase OR 240 ±10 %, 50 Hz, single phase AC power supply as required.
Supply of 2x1.5 sqmm armoured copper conductor control cable conforming to IS 7098 (Pt-1) 1988 for control wiring between UV lamps and Inline fans etc. as required.
SITC of GI Mixing Box suitable for above AHUs to install ESP filters as per site requirement and as per drawing approved by EIC.
Supply, installation, balancing and commissioning of fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. (NOTE:- Pre-fabricated duct may also be accept, nothing extra shall be payble).
SITC of Fabricated GSS Sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm Thick
SITC of Fabricated GSS Sheet metal rectangular ducting as per IS 655-2006 for 0.8 mm Thick
Supply , Installation,Testing and Commissioning of thermal insulated flexible duct of 200 mm dia duly supported at regular interval as per site requirement etc. complete as required as per specifications.
Supplying and fixing of 19 mm thickness duly laminated aluminum foil of mat finish closed sell Nitrile rubber (Class"O") insulation on existing duct after applying suitable adhesive ofr Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhsive Nitrile rubber tape insulation complete as per specifications and as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of following size in the existing open surface/ RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
SITC of Carbon Filters for Inline fans as per specification enclosed complete etc. as required.
Bidder Name
Amount in Words
SNOWMEX ENGINEERS LIMITED
Airef Engineers Pvt Ltd
Weartech Engineers Pvt Ltd
KRISHNA REFRIGERATION
VOLTAS LIMITED
VISION CONTROL PRODUCTS PVT LTD
Aircon Engineers Pvt Ltd
KRISHNA REFRIGERATION
Aircon Engineers Pvt Ltd
SNOWMEX ENGINEERS LIMITED
Airef Engineers Pvt Ltd
VOLTAS LIMITED
Weartech Engineers Pvt Ltd
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .