Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAdmitted-Finance HOUSE NO 190 WARD NO 08 HAMIRPUR | ₹1.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.2 Cr+₹2.8 L (2.40%)Admitted-Finance | ₹1.2 Cr+₹2.8 L (2.40%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Disqualified |
| 4 | Rejected-Technical | - | - | Rejected-Technical Disqualified |
| 5 | Rejected-Technical 313 MENAMKULAM THUMBA KAZHAKUTTAM THIRUVANANTHAPURAM KERALA 695586 | THIRUVANANTHAPURAM | KERALA | 695586 | - | - | Rejected-Technical Disqualified |
| Sl No | Description | Qty | Unit | MSC Roads and Bridges Pvt Ltd L1 | PRIDE EXCLUSIVE L2 |
|---|---|---|---|---|---|
| 0.00CIVIL WORKS | |||||
| 1.00DISMANTLING AND DEMOLISHING | |||||
| 1.01 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below | 5 | Each | 150 ₹750 Lowest | 250 ₹1,250 |
| 1.02 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar | 6 | Cum | 200 ₹1,200 Lowest | 1,250 ₹7,500 |
| 1.03 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead | 25 | kg | 4 ₹100 Lowest | 200 ₹5,000 |
| 1.04 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm | 272 | Sqm | 30 ₹8,160 Lowest | 200 ₹54,400 |
| 1.05 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. | 10 | Sqm | 65 ₹650 Lowest | 200 ₹2,000 |
| 1.06 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : Of sectional area below 40 square centimetres | 25 | m | 9 ₹225 Lowest | 200 ₹5,000 |
| 1.07PLAIN CEMENT CONCRETE | |||||
| 1.08 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work above plinth level up to floor five level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) | 0.4 | Cum | 4,100 ₹1,640 Lowest | 8,000 ₹3,200 |
Tender Value
₹1.2 Cr
EMD Value
₹3.1 L
Closing Date
31 May 2025, 3:00 pmClosed
ASSOCIATE VICE PRESIDENT
HLL Lifecare Limited, HLL Bhavan, No26/4, Tambaram-Velachery Main Road, Pallikaranai, Chennai 600 100, Tamilnadu
Setting up of District Integrated Public Health Laboratory at Pandit Jawaharlal Nehru Govt. Medical College in Chamba District, Himachal Pradesh
2025_HLL_236290_1
HLL/CMO/HCD/DIPHL/CBA/25-26
Open Tender
Civil Works - Buildings
Item Rate
240 days
Govt. Medical College in Chamba District, Himachal
Please refer Tender documents.
17 documents required · 17 mandatory
₹1,770
Yes
Payable To
₹3.1 L
Yes
10 Jun 2025
23 May 2025
2 Jun 2025
23 May 2025
31 May 2025
23 May 2025
Amount
CIVIL WORKS
DISMANTLING AND DEMOLISHING
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : Of sectional area below 40 square centimetres
PLAIN CEMENT CONCRETE
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work above plinth level up to floor five level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
RCC WORK
"Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level.Concrete of M25 grade with minimum cement content of 330 kg /cum"
Providing and laying in position machine batched and machine mixed design mix M25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
FORM WORK
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for :Edges of slabs and breaks in floors and walls Under 20 cm wide
MASONRY WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand)
Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry with 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
PLASTERING
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand)
DOORS & WINDOWS
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). in salwood
Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)Decorative plywood one side decorative veneer and commercial veneer on other face (Type 1) conforming to IS 1328 BWR Type
Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured).
Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing to existing door frames24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge( For W.C. and bathroom door shutter).
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 48x40 m
Providing and fixing of vertical/roller blinds width 100 mm regular quantity made from 100 % polyster/Fibre yarn coated with fade resistant polymer to ensure complete opaquety with zero light transmittance, having suitable coating on exterior, including all fixtures and fittings complete in all respect as per design and instruction of Engineer in-charge and as per site conditions. The colour will be approved by the competent authority.<br> and inclusive of all labour charges.
Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm
Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in- charge.
Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames with rawl plugs screws etc.
Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge (Door handle, lock and stopper etc. to be paid separately)
Providing and fixing of glass door SS Patch Lock with out handle in toughened glass door including all necessary screws etc. complete.
Providing and fixing Steel S.S- 304 (D) Door Pull Both Side Handle of 12 inch, one Set (2 Handles) ( best make of approved quality ) for Glass, Wooden or similar doors including necessary cutting and making good etc. complete
TILE WORK
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately)
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joint treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. Area of slab over 0.50 sqm
Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/ Granite/ stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
FALSE CEILING & CLADDING
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum moisture resistant board
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 1GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
PAINTING
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
STEEL WORKS
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
Providing and fixing plain Multipurpose Cement board (High Pressure steam cured) as per IS : 14862, with suitable screws for fibre cement board as false ceiling, side covering, work slab support etc. complete (frame work to be paid separately) :6 mm thick cement board
Providing at all heights, levels and locations Aluminium profile industrial troughed sheet of Alloy 31500/31000/40800, conforming to IS 1254, IS 737, IS 2676. The sheet shall be fixed using self drilling/ self tapping SS screws of size 5.5x65 mm with EPDM seal complete upto required pitch in horizontal, vertical or curved surfaces i/c cutting to size and shape where required as per specifications, detail drawings and direction of Engineer-in-Charge. The rate shall be inclusive of all screws, seal, ridge, labour, scaffolding, machinery for fixing and approved sealent where required etc. but excluding the cost of purlins, rafters and trusses 0.71 mm thick, the profile detail width 1044/920 mm, cover width 1000/875 mm.
ALUMINIUM WORKS
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separatelyPowder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer in-charge.Pre-laminated particle board with decorative lamination on both side
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and fixing glazing in door, window, ventilator shutters and partitions etc. with EPDM rubber /neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): toughened glass of 6 mm thickness.
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 75mm
Providing and Fixing Aluminium Double U channel of required size for sliding doors
PASS BOX
Pass Box shall be provided at required locations for transfer of samples, chemicals and materials into the laboratory Pass box with UV to be provided. The Pass Box shall be constructed in 18 swg SS 304. The corners inside the Pass Box chamber shall be coved for easy cleaning. The pass box chamber dimension shall be approximately 610 mm x 610 mm x 610 mm. The unit shall be complete with HEPA filters, blower, motor, door electromagnets, door interlock, UV Lamp with timer, necessary wiring, controls and all other accessories. Etc. complete.
GLAZING WORKS
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin- Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub-head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Sl No Specification No Length Width Depth Cf Quantity Structural glazing system Tests to be conducted in the NBL Certified laboratories 1. Performance Laboratory Test for Air Leakage Test (-50pa to ? 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr? 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.? 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testing method for a range upto 2000 ml? 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm? 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test? Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml?
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units ofProviding and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account)
PUF WORKS
Supply Installation Testing & Commissioning (SITC) of Wall panels made up of GI powder coated of 0.8 mm thick sheet on both sides, with 100/80 mm thick class 'O' PUF of min.38kg/m3 density sandwitched in between. The GI sheet shall have 80 micron thick powder coating by hot dip galvanizing with zinc coating not less than 180gm/sqm both side of the panel. Scope includes bottom runner, inter connecting profiles, fixing arrangements, silicon sealant application and all other accessories required to complete the work as per site requirement. Colour: Powder coated, complete with all necessary hardware, accessories, fittings and fixtures, as per description in individual items, technical specifications, drawings and instructions of the Engineer-Incharge Self-supporting wall provided in modular units consisting of external skin in PCGI/ PCGI which will be 0.8mm thick ,with protective film to prevent surface damage during shipping and installation. Movable Wall Includes a) Puff Instulation 40kg/m³ b) GI frame work c) Silicon Sealant (Clear/White/Winsil Gray)
Supply installation testing & commissioning (SITC) of the Modular False Ceiling System shall comprise of ceiling panels of double skin type 50mm thick, sandwiched with selfextinguishing quality PUF of density not less than 38kg / cum the inner and outer skin shall be of powder coated steel sheet, the thickness of inner skin and outer skin of the panel shall not less than 0.8mm the powder coated steel sheet shall be hot dip galvanized with zinc coating not less than 180gm/sqm both side of the GI sheet used. The false ceiling system shall also include ceiling grid system consisting of T-grid of extruded aluminum anodized surface, wall angle, suspender rod, turnbuckle, nuts, bolts, anchor fasteners etc., as required for fixing the panels, & HEPA filter frame, ceiling grid configuration length and width shall be suitable for fixing ceiling blanks, HEPA module, light fixtures etc. All the suspended material shall be galvanized finish. The ceiling grid system shall be suitable for walkable type false ceiling.the vertical panels to be from false ceiling till the true concrete ceiling. Fire rating - class O and colored approved by HLL. IMPORTANT NOTE: The contractor to take utmost care for tranport,shifting and erecting complete with all necessary hardware, accessories, fittings and fixtures, as per description in individual items, technical specifications, drawings and instructions of the Engineer-Incharge.Note:Necessary cutopens to be made for service outlets and finished after passing the service outlets.
Supply, Installation, Testing & Commissioning (SITC) of modular sandwiched doors of width 0.8m to 1m width and 2.1m to 2.3m height both side GI powder coated sheet of 0.4mm thickness duly flushed with the walls, with 45 mm thick PUF, sandwiched between GI sheets, with seal door, including flushed hinges, view panels (as per the site requirement), SS 304 handle/ push plates and hydraulic door closers. Including Stainless steel hinges, Stainless Steel ; type handles on pull side, Stainless steel push plates on push side, Dorma make standard arm door closure (TS-68), View panel along with self-adhesive tape and silicon sealant, both side key operated locking arrangement, Door seal at the bottom & Sides, Stainless Steel kick plates, Filler material: Puff Insulation, Rock wool. Door complete with all necessary hardware, accessories, fittings and fixtures, as per description in individual items, technical specifications, Colour, drawings and instructions of the Engineer-In charge.
PLUMBING & SANITARY FITTINGS
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lidProviding and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid
Supplying and fixing CP Health Faucet superior quality (Jagur or equvalent make) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. weighing not less than 105 gms.
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed on wall
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 :15mm nominal bore
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
Providing and fixing Polypropylene laboratory sink with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 20.9 x15.3 x 11.1 inches; 2.26 Kg.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe 40 mm dia
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:15 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:20 mm nominal bore
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690gms. 15 mm nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the wall 32 mm nominal dia Pipes
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes, float valve but without the base support for tank. Make:sintex, aqua tech ,kelachandra or equivalent
Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.20 mm nominal bore, weighing not less than 40 gms
Providing and fixing PTMT grating of approved quality and colour. Circular type 100 mm nominal dia
Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 38mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighing not less than 263gms.
Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore
Electrical
Point wiring in PVC conduit with modular type switch.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring through PVC conduit
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2X1.5 sq.mm + 1X1.5 sq.mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2X2.5 sq.mm + 1 X2.5 sq mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2X4 sq.mm + 1X4 sq.mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 4X16 sq.mm + 2X6 sq.mm earth wire
Modular type blanking plate:
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Modular boxes, bases & cover plate:
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 2 module
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 3 module
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 6 module
Modular type switch/socket:
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 5/6 Amps switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 3 pin 5/6 Amp socket outlet
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 15/16 Amps switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 6pin 15/16 Amps (universal) socket outlet
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. Telephone socket outlet
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
DB, Enclosure
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator) 4 way (4 + 12), Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator) 6 way (4 + 18), Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator) 8 way (4 + 24), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required. Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A(TPN DB incomer)
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A(TPN DB incomer, AHU)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 12 way (12+36) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 12 way (12 + 36), Double door
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 100mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 100mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Supplying and fixing FP sheet steel enclosure on surface/ recess along with 63 amps 415 volts ,FP Isolator complete with connections, testing and commissioning etc. as required.
EARTHING
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
CABLE LAYING
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
LT CABLE TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 185 sq. mm (57mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm (32mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 25 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 6 sq. mm (19mm)
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
CABLE TRAYS
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray(Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness
LIGHT FITTINGS & FANS
Supply of recess mounted, CRCA with powder coated housing, frosted PMMA / PC diffuser, 33-36W LED light fixture (2x2 feet), p.f 0.9, THD < 10%, 3.0kV surge protection, CCT 6500K, Efficacy 80 Lm/W, CRI 80 etc with all required accessories, including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required. (Recommending Havells PLANO2X2PLR34WLED840S).
Supply of surface mounted, extruded aluminium with powder coated housing, frosted PMMA / PC diffuser, 20-24 W LED light fixture (4 feet), p.f 0.9, THD < 15%, 2.5kV surge protection, CCT 6500K, Efficacy 100 Lm/W, CRI 80 etc with all required accessories, including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.
SITC of 2 feet surface mounted batten type luminaire with a power consumption not more than 10 W, luminaire lumen output of 1200 lumens, luminaire efficacy > 120 lm/W with an operating voltage range from 140 V - 270 V. The luminaire shall have a white CRCA housing with a poly carbonate diffuser to provide uniform light and a sleek design with width not more than . The luminaire shall have a CCT of 4000K ,6500 K , CRI > 80, power factor >0.95, SDCM < 5, THD <10% and 50,000 burning hours as per L70B50 criteria. The luminaire shall have flicker content <5% and shall have high and low cut off with auto restart feature. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 kV. The luminaire shall have Class - 1 Electrical Insulation, Class - B Serviceability (The driver can be replaced at site level). The luminaire and driver shall be BIS approved and test certificates of LM79 and LM80 reports from NABL accredited labs.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supply of wall fan 400 mm sweep, 230V, 1Ph, plastic body and blades, pull cord for speed regulation, complete with all accessories as required, including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.. (Crompton High Flo LG / Khaitan Dezire / Havells Mozel)
SITC of recess mounted LED downlighter with a circular form factor with a power consumption of 18 W and a system level lumen output of 2000 lumens and a system level luminous efficacy 110 lm /W. The luminaire shall have a pressure die cast aluminum housing, a polycarbonate diffuser and a sleek design of product height not more than 40 mm. The luminaire shall have a CCT of 6500 K , CRI>80, power factor>0.9 and THD <10 %. The luminaire shall have a non integral LED driver with 50,000 burning hours as per L70B50 criteria, 2.5 kV surge protection. The luminaire shall be EMI/ EMC compliant and should have a Class B serviceability (The driver can be replaced at site level).The luminaire and driver shall be BIS approved and test certificates of LM79 and LM80 reports shall be submitted
SITC of EXHAUST FAN,SHUTTER TYPE white colour, 9" or 10"-5star rated as per BEE complete with its all accessories including mounting accessories and connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.
SUPPLY OF LT CABLES
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3½ X 185 sq. mm (Incomer)
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3½ X 35 sq. mm (for ODU )
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 4 X 25 sq. mm (for UPS )
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 4 X 16 sq. mm (for DB, AHU )
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 4X10sqmm(for DB )
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 2X10sqmm(for EXHAUST)
ELECTRICAL MISCELLANEOUS ITEMS
Providing & fixing in position 1000 mm wide , Electrical Insulating Mats as per IS 15652:2006, 2.0mm thick, suitable for 1.1 KV , fire retardant,no effect of acids, alkalies and transformer oils, moisture proof, high tensile strength and texture finish / cloth impression (Anti slip , marking on top) .
Supply and fixing of Shock treatment chart duly mounted on a wooden frame with glass on front as required in 2 languages (Hindi & English)
Supply and fixing of First aid box as approved by St. John Ambulance Brigade /Indian Red Cross society conforming to IS : 2217 - 1963.
Providing and fixing of 4 Nos. 9.5 Litre capacity GI bucket painted in post office red colour with prior coat of red oxide paint and written with white paint ‘FIRE’ and mounted on MS angle iron frame with bracket of appropriate size & capacity I/c filling sand etc.
SUB PANEL
Supply installation testing and commissioning of 200A,LT floor mounted type, dust and vermin proof, free standing cubical type construction, made out 16SWG CRCA sheet painted with approved colour after decrea sing pickling, phosphating etc consisting of the following: (a) Incomer : 200A, 4P MCCB - 1 No, (b) Bus bar: 200A Aluminium bus bar,(c) Outgoings;1. 100A FP 16kA MCCB Thermal Magnetic Release - 1 Nos, 2. 63A FP 16kA MCCB Thermal Magnetic Release - 4 Nos, 3. 40A FP 16kA MCCB Thermal Magnetic Release - 3 Nos. Meters : All meters shall be of 96 mm square, panel mounting type and accuracy class 1.0 or better with finger-proof terminals. 1. Multi-Function Meter : CT operated, 3 x 240 V, 3 x -/5 A, 3-Phase 4 wire, Cl. - 0.5 meter to read voltage, current, p.f., power etc. - 1 Nos. Indication Lamps : LED type R, Y, B coloured indication lamps with 2 A HRC control fuses mounted on 32 A Bakelite fuse carrier & base - 3 set . Earthing : As per standards
ELV SYSTEM
CCTV SYSTEM
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
Supply,Installation,Testing & Commissioning of 3+1 coaxial pure copper CCTV camera cable with its all accessories Make: Finolex/Polycab/CP plus
Supply,Installation,Testing & Commissioning of Digital Video recorder with H.264, H.264+& Dual-stream video compression, Support HD-TVI, AHD and analog cameras with adaptive access, Support 1080P lite mode enabled to realize the real-time, 1080P lite and 720P lite resolution, Long transmission distance over coax cable, Up to 8-channel synchronous playback at 1080p resolution, Playback at up to 256X speed. Make: Hikvision/Dahua
Supply,Installation,Testing & Commissioning of Solderless BNC with gold plated termination pins screw type for termination of the coaxial cables DVR side
Supply,Installation,Testing & Commissioning of Solderless BNC with gold plated termination pins screw type for termination of the coaxial cables camera ends with field side termination housing box plastic type.
Supply,Installation,Testing & Commissioning of HD1080P IR Dome Camera with, 2.0 Megapixel high-performance CMOS, Lens: 2.8mm, Analog HD output, up to 1080P resolution, True Day/Night, Smart IR, Up to 20m IR distance, IP66 weatherproof, Switchable TVI/AHD/CVI/CVBS. Make : Hikvision/Dahua/CP Plus
Supply,Installation,Testing & Commissioning of Surveillance HDD with 4 TB space.make:Seagate/WD/Samsung.
Supply,Installation,Testing & Commissioning of 12 V 16/20 Amps Power Supply
Supply,Installation,Testing & Commissioning of rack Mounting Tray for DVR
Supply,Installation,Testing & Commissioning of 5 Mtr HDMI Cable which Provides full 1080p support, 3D Compatible, 4K Cinema resolution, Built-in audio return channel for smooth sound, Up to 120Hz refresh rate for a clear picture, Built-in Ethernet with 10.2 Gbps bandwidth speed, 24K Gold-plated connectors to minimize signal loss.
PASSIVE
Supply, Laying, Testing & Commissioning of CAT6 (RJ-45) I/O Ports
Supply, Laying, Testing & Commissioning of CAT6 Patch Panel
Supply,Installation,Testing & Commissioning of CAT6 Patch Cord with Moulded boots, Over-moulded boot at each end provide strain relief and maintains minimum bend radius of the cable - 2 Meter
Supply , Installation,Testing and Commissioning of 24' LED TV
Supply, Installation, Testing & Commissioning of 9U Network Rack with below specifications as minimum and all the necessary accessories: - Lock & Keys - Tray (1 No) - 1 Cooling Fan and Adjustable Shelf - Height - 9U - Dimensions - 13x12x11 cm - Fan Units with 1coolin Fans - PDU 6 point - 1 Nos's - Mounting Hardware Kit (1 lot) - Tray - Front glass doors and back steel door and side panels
ACTIVE
Supply, Installation, Testing & Commissioning of 16 Port Network Switch with 16 No's of 10/100/1000 ports and 2 Gigabit Copper/ SFP Combo ports for uplink
TELEPHONE CONNECTION
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required..Telephone socket outlet
Supply , Installation of PBX System with below features and accessories - 1 PRI Port(T1/E1) expandable upto 4 PRI ports - 4 Analog Trunk Lines - Extensions - 16 ( Analog or IP as required )
Supply of User Phone- Analog phone
ACCESS CONTROL SYSTEM
Supply and installation of Fingerprint Weigand Readers with Features like Sensor Optical Sensor Communication RS 485 Optional Features Prox / Mifare / HID card reader Voice Prompt Buzzer.Make: ESSL/HID
Supply and installation of Electromagnetic Lock for Securing Doors during idle time. With L Clamp for Fitting Purpose. Make: ESSL/ALGETEC
Supply and installation of 12V 20 A Power Supply for the device. Make: ERD/PROTEK
Additional Accessories for Fixing - Z clamp. Make: ESSL/HID
Emergency Panic Exit Switch with break glass. Make: ESSL/ALGETEC
Supply, Laying, Testing & Commissioning of 4 Core Multi Stranded Cable for Controller to EM Lock & Contact connection with below specifications as minimum and all the necessary accessories - 4 x 1.0 Sqmm - Unarmored - PVC FRLS - Unshielded
Supply, Laying, Testing & Commissioning of 8 Core Multi Stranded Cable for Controller to Reader connection with below specifications as minimum and all the necessary accessories - 8 x 1.0 Sqmm - Unarmored - PVC FRLS - Unshielded
Supply, Laying, Testing & Commissioning of 2 Core Multi Stranded Cable for Controller to Exit Switch connection with below specifications as minimum and all the necessary accessories - 2 x 1.0 Sqmm - Unarmored - PVC FRLS - Unshielded
PA SYSTEM
Speaker cable Two pair, 2-core, 1.5 sqmm
Supplying, Installation, Testing & Commissioning of 6W ceiling speaker complete as required
Supply, Installation, Testing and Commissioning of professional rack mountable 60 Watt Amplifier to connect MP3 player, FM tuner, SD, USB, 4 Mic / line inputs, 3 Aux Input, 70V/100V, 4-16ohms Output, Individual Volume control & output etc. complete with all standard accessories.Make:Ahuja/Bosch
Supply of Wired Handheld Mic with connection cable. Make: Ahuja
FIRE DETECTION & ALARM SYSTEM
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required(other areas & above ceiling)
Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 4 ZONE
Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supply and installation of Co2 Fire Extinguisher (Trolley Mount - Wheel Operating) Type 4.5KG with MS clamps etc. for fixing on wall/wooden partition with 01 year warranty. I.S. No. 13849.
Supply and fixing of 4Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per IS 15683 with Fire rating 1A 8B, Body Hydrotested at 35 bar, Operating temperature -30°C to +55°C, external epoxy powder coating with PO Red Shade No. 538 of IS 5, Supplied with standard accessories.
SIGNAGES
Supplying and installing in position of 6W, 240 V, 1 ph, 50 Hz indoor type LED sign boards of size (180 X 300 mm) with battery backup. Indicating the following. Samples has to approved by the Architect/Client before procuring the same. EXIT
Supplying and installing in position self glowing sign boards of sixe (150 X 400 mm) made of luminescent safely, rigid sheet in green colour, photo luminescent ACP sheet in protective glass with two hanging chains & necessary supports to hang it on ceiling. Samples has to approved by the Architect before procuring the same of the following signs EXIT
Supplying and installing in position self glowing sign boards of sixe (150 X 400 mm) made of luminescent safely, rigid sheet in green colour, photo luminescent ACP sheet in protective glass with two hanging chains & necessary supports to hang it on ceiling. Samples has to approved by the Architect before procuring the same of the following signs FLOOR INDICATION
Supplying and installing in position self glowing "FIRE ASSEMBLY POINT" sign boards of size (150 X 300 mm) made of luminescent safely, rigid sheet in green colour, photo luminescent two foam sheet fixed on the wall. Samples has to approved by the Architect before procuring the same.
AHU - VRF SYSTEM FOR BACTERIOLOGY & VIROLOGY LABS
VRF OUTDOOR UNITS
Supply, Installation, Testing and Commissioning of Air-cooled VRV (Variable Refrigerant Volume) / VRF (Variable Refrigerant Flow) Outdoor units (ODU), suitable for Heating and Cooling, equipped with highly efficient, full DC inverter-driven Scroll compressors only, air- cooled heat exchanger having internally grooved copper tubes, and a low-noise condenser fan. The units should have auto-addressing, an auto-check function for connection errors, R-410A/R407C Refrigerant gas. The machine should be fitted with a Noise filter, High-Pressure Switch, Fan Driver Overload Protector, Over-Current Relay, Inverter Overload Protector etc. The outdoor unit and the rest of the indoor units shall remain in operating condition even when the main line power supply of one or more indoor units fails. The ODUs shall be provided with suitable vibration isolators. The system should operate up to a minimum ambient DB temperature of 52 degrees Celsius. The unit shall be equipped with an oil recovery system ensuring stable operation with long refrigeration piping lengths. The system must be provided with an oil balancing circuit to avoid poor lubrication. Compatibility with centralized control systems like BACnet, Lon Works, MODBUS is required. ODUs should be suitable for 3-phase, 415 V, 50Hz supply. along with suitable interconnecting control cabling between IDUs, ODUs, and the central controller, power cabling between ODU and Isolator, earthing with necessary supports between the isolator and single/multiple outdoor units, Pressure Testing, Additional refrigerant charging for commissioning, Vibration isolators etc along with all associated accessories, complete in all respects as per the consultant's approval VRF ODU Machine Schedule VRF ODU Circuit#1: 14 HP
AIR HANDLING UNITS
Supply, Installation, Testing and Commissioning of VRF compatible 5.5TR - 2200 CFM, 75mm E.S.P, Dx type AHUs factory built with Three Stage Filtration including HEPA Filters, Double skin AHU complete with 6 row Dx Copper Cooling/Heating coil, made of 40 mm thick panels consisting of G.I casing of thickness 0.8mm outside and 0.8mm inside G.I casing with factory injected PUF injected between them by injection molding machine, complete with Plug Fan with VFD with minimum 2 bend GSS/PVC eliminators, cooling coil section with aluminum finned copper tubes filter section with 50 mm thick metal viscous/washable synthetic type air pre/post filters (MERV7 & MERV 14), mixing box, VCDs on Fresh air Return air & Supply air opening, TEFC drive motor suitable for 415 ± 10% volts, 50 Hz 3 phase, A.C supply, drain connection, drain pan, necessary vibration isolation arrangement, expansion valve, drier, Dx VRF AHU Kit, Corded Remote Controller along with all neccessary control/power wiring. UVC Lamp with airborne inactivation option (UV emitters shall be minimum 12watt/Sq.ft of coil surface area for equal distribution), Pantype Humidifier, Strip heater with thermostat and RH Sensor (Strip Heater/Pan Type Humidifier Capacity has to be proposed by manufacturer). A separate control panel with thermostat and Humidistat should be provided for strip heater/humidifier. AHUs Should be Eurovent/AHRI Certified
EXHAUST FANS
Supplying, installing, testing and commissioning Cabinet Exhaust fan, 500CFM @ Min 40mm static pressure. The casing shall be double skin, internally acoustically lined and constructed of galvanized steel. Suitable for operating in Single Phase supply. The fan shall be DIDW with forward curve impeller. Each fans shall be considered with HEPA filter having filtering efficiency of 99.7% down to 0.3 microns. Installation shall be all inclusive of electronic speed regulator, power and control wiring between power supply fan and speed regulator, suitable enclosure, including all necessary accessories as required.
VRF/AHU ACCESSORIES
Supply, Installation, Testing and Commissioning of INDOOR Refnet / Y-joint separation tubes for refrigeration pipe joints and headers in appropriate orientation to enable proper distribution of refrigerant. The distribution joints should be factory insulated with pre-formed section of expended polystyrene / equivalent.
Supply, Installation, Testing, and Commissioning of gas/liquid copper insulated piping finished with aluminum tape, having UV and weather-resistant properties. This includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The copper lines shall be insulated with 19 mm thick closed-cell antimicrobial nitrile rubber sleeve insulation. The work shall be completed in all respects as per the consultant's approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturer's (OEM) technical/recommended specifications. Soft drawn Copper Pipe 19/20 Gauge with 19mm thick Insulation:1/4" (6.35 mm)
Supply, Installation, Testing, and Commissioning of gas/liquid copper insulated piping finished with aluminum tape, having UV and weather-resistant properties. This includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The copper lines shall be insulated with 19 mm thick closed-cell antimicrobial nitrile rubber sleeve insulation. The work shall be completed in all respects as per the consultant's approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturer's (OEM) technical/recommended specifications. Soft drawn Copper Pipe 19/20 Gauge with 19mm thick Insulation:3/8" (9.52 mm)
Supply, Installation, Testing, and Commissioning of gas/liquid copper insulated piping finished with aluminum tape, having UV and weather-resistant properties. This includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The copper lines shall be insulated with 19 mm thick closed-cell antimicrobial nitrile rubber sleeve insulation. The work shall be completed in all respects as per the consultant's approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturer's (OEM) technical/recommended specifications. Soft drawn Copper Pipe 19/20 Gauge with 19mm thick Insulation:1/2" (12.7 mm)
Supply, Installation, Testing, and Commissioning of gas/liquid copper insulated piping finished with aluminum tape, having UV and weather-resistant properties. This includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The copper lines shall be insulated with 19 mm thick closed-cell antimicrobial nitrile rubber sleeve insulation. The work shall be completed in all respects as per the consultant's approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturer's (OEM) technical/recommended specifications. Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:5/8" (15.88 mm)
Supply, Installation, Testing, and Commissioning of gas/liquid copper insulated piping finished with aluminum tape, having UV and weather-resistant properties. This includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The copper lines shall be insulated with 19 mm thick closed-cell antimicrobial nitrile rubber sleeve insulation. The work shall be completed in all respects as per the consultant's approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturer's (OEM) technical/recommended specifications. Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:3/4" (19.05 mm)
Supply, Installation, Testing, and Commissioning of gas/liquid copper insulated piping finished with aluminum tape, having UV and weather-resistant properties. This includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The copper lines shall be insulated with 19 mm thick closed-cell antimicrobial nitrile rubber sleeve insulation. The work shall be completed in all respects as per the consultant's approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturer's (OEM) technical/recommended specifications. Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:7/8" (22.2 mm)
Supply, Installation, Testing, and Commissioning of gas/liquid copper insulated piping finished with aluminum tape, having UV and weather-resistant properties. This includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The copper lines shall be insulated with 19 mm thick closed-cell antimicrobial nitrile rubber sleeve insulation. The work shall be completed in all respects as per the consultant's approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturer's (OEM) technical/recommended specifications. Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:1.0" (25.4 mm)
Supply, Installation, Testing, and Commissioning of gas/liquid copper insulated piping finished with aluminum tape, having UV and weather-resistant properties. This includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The copper lines shall be insulated with 19 mm thick closed-cell antimicrobial nitrile rubber sleeve insulation. The work shall be completed in all respects as per the consultant's approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturer's (OEM) technical/recommended specifications. Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:1-1/8" (28.6 mm)
Supply, laying and testing of Protective layer for Copper piping with woven fibre glass cloth wrapped around copper piping tubular insulation and with foster painting as required
Supply, laying, and testing of shielded copper flexible communication/transmission cabling between VRF indoor units and outdoor units. The communication cable must be routed through PVC conduit. The sizing of the cable to be 2 Core x 1.5 SQMM (or) as per VRF- OEM's technical/recommended specification.
Supply, Installation, testing and commissioning of 25mm rigid UPVC condensate drain pipes of following size duly insulated with 9mm thick closed cell nitrile along with necessary clamps, fittings such as bends, tees etc. adequately supported complete as required confirming to specification.
Supply and fixing of suitable factory fabricated AHU control panel all including necessary control and Power cable wiring between AHU and Panel. Panel to have following features. Panel should include Controls, contactors, OLR, SPP, control switch, MCBs for AC units, Control wiring for Thermostat, Humidistat, Safety thermostat, smoke detection system etc. ON/OFF switch with indicator, bypass DOL/star delta starter for VFD. The panel should have change over switch with indication lamp for manually change over from VFD to DOL/star delta starter. The panel shall have contactors and breaker for the heater banks with required power and control wiring to maintain RH% as per inside design condition. If there are four coils of strip heater one should connect to the thermostat and other three should connect to the humidistat, ie one strip heater should cutoff once the temperature reaches the set point) etc
DUCTING & ACCESSORIES
Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick
Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick
Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 1.00 mm thick
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.: 19mm
Supply and fixing of acoustic insulation on plenum and initial portion of the duct upto 3 mtrs or as suggested from the Ductable units mouth with open cell type 10 mm thick nitrile sheet, with density 140- 180kg/m3 and anti Microbial Properties fixed with manufacturer recommended adhesive and tightened with necessary accessories etc. as required.
Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper
Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Fire damper
Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Actuator
Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supplying and Fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.
Supply and installation of Fresh Air/ Exhaust Air Louvre of aluminium powder coated with bird Screen as per specifications and drawings.
Supply, Installation and fixing- hanging of FACTORY fabricated fire retardant flexible Canvas connection of minimum 150mm width, at outlet of each Ducted Indoor unit with zipper to facilitate temperature measurement. The fabric to be made of Polyester cloth, black PVC coating on both sides along with galvanised steel seam.
Magnehelic Gauge of Dial size 4" and Pressure Range of -50 to 50 Pa.
SPLIT AC (HOT N COLD) FOR GENERAL LAB AREAS
Supply, Installation, Testing and Commissioning of HOT n COLD - 3 Star rated Inverter type split AC units , Hi-wall mounted, preferably with anti corrosive / powder coated outdoor units, fitted with hermitically sealed suction cooled energy efficient Scroll / Rotary compressor operating on R-32 / HFC-134a / 407 C / 410 A refrigerant suitable for operation on 220 V, 1 Ph, 50 Hz A/C supply. The units shall be inclusive of all standard accessories like power & control cables, good quality copper tubing of minimum 3 meter length to interconnect the outdoor unit with indoor unit for refrigerant lines, elastomeric Nitrile rubber insulation, clamps etc. Notes: (1) Condenser tubes, Evaporator tubes & connecting pipes should be made out of good quality copper. (2) High-energy efficient compressor of rotary / Scroll type (3) Cordless remote for setting Temp, on time, off time, power saving mode, auto mode operation, sleep mode, auto setting with memory backup, time delay feature, programmable timer, etc. with real time clock. (4) Warranty: 5 Years on PCB, 10 years warranty on compressor and one year warranty for the total system from the date of handing over/ commissioning Make: Blue Star / Voltas / Carrier Midea / Hitachi / Daikin / Panasonic / Mitsubishi / Toshiba / Trane / O General Tonnage - 1.5TR
Supply & installation of Stabilizer suitable for 1.0TR/1.5TR Capacity Split AC units inclusive of all necessary wiring/connection. Stabilizer should comply with the detailed specification mentioned below. Intelligent Time Delay System, Latest IC Technology - Assures reliable protection, Wall Mounting Cabinet Design - Elegant and easy to install, Low & High Voltage cut-off Protection, Built-In Thermal Overload Protection - Protects the stabilizer and compressors during high-temperature burnout, Working Rage Voltage - 170 VAC - 270 VAC Make: V-Guard/Vstab / Microtek or Equivalent with ISI Standard.
Supply and fixing of M.S OUTDOOR STAND for Split ACs. The work involves supply of heavy duty powder coated mounting bracket for outdoor unit with mounting bolts, complete as required and as directed by the Engr.-in-Charge
Drain Piping for Split ACs: Supply & installation of PVC insulated piping for condensate drain Including wall chasing, necessary supports, Clamps etc complete as required
Additional refrigerant Copper piping Kit for Split Acs (Upto 2.0TR) : Supplying and installation of additional refrigerant piping kit consisting of power and control cables, good quality copper tubing, Elastomeric Nitrile rubber insulation etc. for Split AC units.
PRIDE EXCLUSIVE (BID ID -855997)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.07 MB
TEDOCHAMBA.pdf
Tender Documents • 1.05 MB
BOQ_268038.xls
BOQ • 0.54 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .