Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹31.2 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹32.5 L+₹6,788 (0.21%)Rejected-Finance | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹34.9 L+₹2.4 L (7.54%)Rejected-Finance | L-3 | Rejected-Finance L-3 | |
| 4 | L-4₹37.6 L+₹5.2 L (15.9%)Rejected-Finance PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | L-4 | Rejected-Finance L-4 | |
| 5 | L-5₹49.6 L+₹17.2 L (53.1%)Rejected-Finance RZB 69 GALI NO 5 RAJ NAGAR PART 1 WEAT DELHI DELHI 110045 SOUTH WEST DELHI DELHI 110045 UDYAM DL 10 0018772 | SOUTH WEST DELHI | DELHI | 110045 | L-5 | Rejected-Finance L-5 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
2 Mar 2024, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
COMPREHENSIVE MAINTENANCE TO CERTAIN MD ACCN, MESSES, BILLETS, REPAIR TO ROLLING SHUTTER, GATES, ROOF TRUSS, REPAIR/REPLACEMENT OF INTERNAL WIRING WITH FITTING FIXTURES AND OTHER ALLIED WORKS AT AF STN CHANDINAGAR IN AOR OF GE (AF) FARIDABAD
2024_MES_640424_1
GE (FBD)/AF-78/2023-2024
Open Tender
Civil Works
Item Rate
180 days
Chandinagar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹98,000
Yes
10 Apr 2024
2 Feb 2024
5 Mar 2024
2 Feb 2024
2 Mar 2024
17 Feb 2024
2 Feb 2024 - 9 Feb 2024
Amount
Taking down chowkats with shutter (without taking off shutter from the frame) n exc 1.5 Sqm each and removing from site complete all as specified and directed by Engineer-in-Charge.
All as per item No 01 above but exc 1.5 sqm but n exc 4.0 sqm each
Taking down shutter of any description n.exc 1 sqm each complete all as specified and directed by Engineer-in-Charge.
All as per item No 03 above but exc 1.0 sqm but n exc 2.0 sqm each complete all as specified and directed by Engr-in-Charge.
S&F for Pressed steel frames of size 105 x 60mm for doors , windows and ventilators etc, with one or more rebates including PCC 1:2:4 type B0 (12.5mm graded stone aggregate) filling in hollow frame section and necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed by Engineer-in-Charge.
S&F for Pressed steel frames of size 125 x 60mm for doors , windows and ventilators etc, with one or more rebates including PCC 1:2:4 type B0 (12.5mm graded aggregate) filling in hollow frame section and necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in opening complete solid PVC door frame of size 50mm x 47mm made out of 5mm one side prelaminated any colour PVC sheet reinforced with MS square tube complete all as specified and directed by Engineer-in-Charge.
S&F for 35mm thick 2nd class hardwood Plain, framed panelled shutters(any No of panels) with panels of timber flat on both side (feather edged) or of veneered particle board medium density wood particle board with commercial face veneers fixed to chowkats complete all as specified and directed by Engineer-in-Charge.
S&F for 30mm thick 2nd class hardwood for glazed and skeleton shutters open rebated and prepared to receive glass, gauge etc (without sash bar) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of members of shutters as per SSR-Part-I Section-8, Clause 8.24 (a) etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 09 above but 25mm thick for window, ventilatators etc.
S&F for 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for factory made solid panel PVC door shutter 30mm thick(Style) consisting of frame made out of M.S. tube for top & bottom rails. M>S frame shall be covered with heat moulded prelaminated decorative any colour PVC `C' channel having a PVC sheet strip of 20mm width stuck inside wqith solvent cement for stiles and prelaminated colour PVC sheet for top rail, Lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of both side prelaminated decorative colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement fixing in frame complete all as specified and directed by Engineer-in-Charge.
S&F Butt hinges 100 mm long aluminium alloy anodised and fixed complete all as specified and directed by Engineer-in-Charge.
All as per item No 13 above but 75mm
Supply and fixing 200mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed by Engineer-in-Charge.
S&F 125mm aluminium extruded alloy handles fabricated type complete all as specified and directed by Engineer-in-Charge.
All as per item No 16 above but 100mm
S&F 100 mm alumunium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed by Engineer-in-Charge..
All as per item No 18 above but 125mm
S&F 250 mm long aluminium alloy anodised, sliding door bolt with hasp ,staple(bolt type) and fixing clips of sheet cast of extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified and directed by Engineer-in-Charge.
S&F for mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed by Engineer-in-Charge.
Hacking out old broken glass panes (any thickness size quality or description ) from wooden frame fixed with oil putty or beads area not exc 0.5 Sqm each complete all as specified and directed by Engineer-in-Charge.
S&F 3mm thick sheet glass, ordinary quality and glazing fixed with wooden or beading complete all as specified and directed by Engineer-in-Charge.
S&F 5.5 mm thick ordinary quality ordinary quality and glazing with oil putty in square exceeding 0.50 sqm in each pane complete all as specified and directed by Engineer-in-Charge.
S&F for Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed by Engineer-in-Charge.
All as per item No 25 but fixed in repair
Supply and fixing in repairs Harrison rails 20 mm dia mild steel chromium plated curtain rail fixing with brackets stops complete all as specified and directed by Engineer-in-Charge.
S&F Aluminium extruded body door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed
S&F in repair Aluminium alloy body and tongue and roller plate floor door stopper of 150mm size fixed with steel screw complete all as specified and directed by Engineer-in-Charge.
S&F 150mm Hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screw complete all as specified and directed by Engineer-in-Charge.
M&L fixed in repair 12mm thick prelaminated particle board, exterior grade , prelaminated both side with decorative choice lamination fixed to aluminium frame works and similar work complete all as specified and directed by Engineer-in-Charge.
S&F in repair 18/19mm thick prelaminated particle board, exterior grade , prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws to timber with lipping complete all as specified and directed by Engineer-in-Charge.
M&L for Complete removal of existing treatment from walls, fins, chajja etc shall include brooming down or steel wire brushing, scrubbing down smoke soot, moulds, moss and efflorescence salts and treating oil and greasy spots and removing debris/ malba to low lying area out side of MOD land and applying 3 mm thick a layer of wall care putty on scrapped/uneven surfaces to match with the existing surfaces before application of primer/distemper and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of old treated plastered surfaces of wall by brooming down or steel wire brushing scrubbing down smoke soot, moulds, moss and efflorescence salts and treating oil and greasy spots removing dust, dirt and all loose scales of existing treatment and applying two coats of exterior acrylic emulsion water based (weather proof coat) paint on wall complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of old treated plastered surfaces of wall by brooming down or steel wire brushing scrubbing down smoke soot, moulds, moss and efflorescence salts and treating oil and greasy spots removing dust, dirt and all loose scales of existing treatment and applying one coat of oil bound distemper on wall complete all as specified and directed by Engineer-in-Charge.
All as per item No 35 above but two coats of oil bound distemper on wall
Material and labour for preparation of old treated plastered surfaces of ceiling by brooming down or steel wire brushing scrubbing down smoke soot, moulds, moss and efflorescence salts and treating oil and greasy spots removing dust, dirt and all loose scales of existing treatment and applying one coat of oil bound distemper on ceiling complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of old treated plastered surfaces of wall by brooming down or steel wire brushing scrubbing down smoke soot, moulds, moss and efflorescence salts and treating oil and greasy spots removing dust, dirt and all loose scales of existing treatment and applying one coat of cement base paint on wall complete all as specified and directed by Engineer-in-Charge.
All as per item No 38 above but two coats of cement based paint on wall
Material and labour for preparation of old wooden surface of any description over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of old painted steel surface of any description over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L for Brickwork with sub class "B" bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 incl demolition of brick work or stone masonry built in cement mortar including all quions, arches, pillars, etc complete all as specified and directed by Engineer-in-Charge.
Dismantling floor hearth or wall tilling including cement mortat bedding (but not backaing coat) removing serviceable tiles to store & rubbish off from the MOD land complete all as specified and directed by Engineer-in-Charge.
Material and labour for Glazed ceramic coloured tiles in vertical surface 350x250mmx7mm/450X350X7mm/450x300x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match including and over 10 mm thick rendering in cm 1:4 on brick or concrete surfaces of wall to receive vertical tiles complete all as specified and directed by Engineer-in-Charge.
Material and labour for non skid coloured ceramic dark tiles of size 7-8 mm thick area of each tiles exceeding 0.11 Sqm bur not exc 0.18 Sqm (400x400mm) as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement with pigment to match the shade of tiles over and including 15 mm thick screed bed in cm 1:6 complete all as specified and directed by Engineer-in-Charge.
Demolition of PCC cement concrete above ground floor and paving n.exc 15 cm thick (below or above ground level) un reinforced complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:4:8 type D-2 (40mm graded stone aggregate ) for sub base 75mm thick complete all as specified and directed by Engineer-in-Charge.
Material and labour for vitrified Ceramic tiles 10mm thick Dark shade (Square/ rectangular) polished, area of each tiles n. exc 0.36 SQm (600x 600mm) in floors etc,, set and jointed in neat cement slurry and pointed in shite or coloured cement to match over and including 20 mm thick screed bed in cm 1:6 complete all as specified and directed by Engineer-in-Charge.
All as per item No 48 above but in vertical surface such as skirting, dado and risers including 10 mm thick rendering in cm 1:4 on brick or concrete surfaces of wall to receive vertical tiles
Taking up or down 15mm bore steel tubing and connections including cleaning for refixing or removing to store complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for 15 mm bore steel water tubing galvanised 15mm bore, medium grade fixed to walls and ceiling or in floor complete all as specified and directed by Engineer-in-Charge.
Taking up or down 20mm bore steel tubing and connections including cleaning for refixing or removing to store complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for 20mm bore steel water tubing galvanised, medium grade fixed to walls and ceiling or in floor complete all as specified and directed by Engineer-in-Charge.
S&F for 15 mm bore concealed type chromium plated Stop valves, cast copper alloy screwed pressure, with crutch of butterfly handle, screwed both ends for iron pipe for unions and fixed complete all as specified and directed by Engineer-in-Charge.
S&F 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring, joints, laid in trenches or in floors or fixed to wall complete all as specified and as directed.
Supply and fixing for 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring, joints, laid in trenches or in floors or fixed to wall complete all as specified and as directed.
Supply and fixing 15 mm dia Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair 15 mm bore chromium plated Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair 15 mm bore chromium plated Stop angle valves, cast copper alloy screwed pressure, with crutch of butterfly handle,long shank and cup, screwed both ends for iron pipe for unions and fixed complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair Brass chromium plated shower rose 125mm size complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in polythene connection of low density polyethylene (LDPE) pipes of pressure rating 2.5 Kgf/Sqcm, 45cm long with and including two brass union couplings, heavy duty, suitable for 15mm bore pipe, one on each end for connecting polyethylene pipe to GI pipe and fixed complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair 10 ltrs capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe complete all as specified and directed by Engineer-in-Charge.
S&F for mild steel work for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc complete all as specified and directed by Engineer-in-Charge.
S&F Box type mild steel windows incl frame made of hollow sections 60X25X1.25 mm thick and 50X20X1.25 mm thick shutter with sash bars incl 150 mm size MS tower bolts 2 Nos each leaf , MS handle made of Z section 100 mm long 2 Nos each leaf , mild steel cleat 55x25X75 mm long one nos each leaf complete all as specified and directed by Engineer-in-Charge.
S&F in repair Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, sheets etc. complete, drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging, also fastening and fixing complete all as specified and directed by Engineer-in-Charge.
M&L for Preparation of new surfaces of wooden any description not other wise described over 10cm width or girth and applying two coat of synthetic enamel paint over coat of primer complete all as specified and directed by Engineer-in-Charge.
M&L for Preparation of new steel surfaces in any description not other wise described over 10cm width or girth and applying two coat of synthetic enamel paint in any colours over coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge.
Dismantling of plain or corrugated steel sheeting, any type and any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engineer-in-Charge.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw complete all as specified and directed by Engineer-in-Charge.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick as in ridge of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw complete all as specified and directed by Engineer-in-Charge.
Supply and fixing anodised aluminium door shutters, aluminium section weighting 0.55 Kg/ RM including necessary jointing cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for anodised aluminium window and ventilator shutters with aluminium grill, side hund type without sash bars aluminium section weighing 0.55Kg/RM including necessary hointing cleats, glazing clips, rubber packing anodised aluminium snap beading, screws anodised aluminium fitting such as peg stay 150mm long (01no) hinges type B21, 100mm long (02 Nos) suitable handle (01 No) complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for anodised aluminium partition fixed type/with out sash bars aluminium section weighing 0.55kg/RM incl necessary jointing cleats, glazing clips rubber packing anodised aluminium snap beading, screw etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing anodised aluminium frame for doors, windows ventilators with one or more rebates including jointing cleat for fixing etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing ordinary quality sheet glass 5 mm thick in panels of aluminium door and window etc fixed with aluminium clip and rubber beading all as specified n exc 0.5 sqm complete all as specified and directed by Engineer-in-Charge.
S&Fsteel ventilator with top hung shutter including hinges,steel peg stay etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs continuous (piano) hinges mild steel bright finish or electrogalvanised 30mm flaps complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for double action floor spring hydraulically regulated made ou of minium 1.25mm thick aluminium allooy sheet foundation box, main body with stainless steel cover governing pivot made of brass, other parts made of MS heavy duty and fixed complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on Brick or concrete surfaces incl racking out joints hacking for key scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 10mm thick in CM 1:4 on concrete surfaces on roof finishing even and smooth without using extra cement but using water proofing compound @ 3% by weight of cement complete all as specified and directed by Engineer-in-Charge. Note : WPC shall be measured & paid for separately
Supply only water proofing compound complete all as specified and directed by Engineer-in-Charge.
Material and labour for rendering 15 mm thick in CM 1:6 on fair faces of brick or concrete surfaces of walls, facia etc to be finished even and smooth (w/o using extra cement) complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparing newly plastered surfaces and applying two coats of distemper oil emulsion including priming plastered and other surfaces with chalk whitening preparatory to distempering on surfaces of walls complete all as specified and directed by Engineer-in-Charge.
Dismantling of stone slab and tiles of any description or thickness in floors, approns etc laid, bedded and pointed in any mortar and removing rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Material and labour for granite tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing types over and including including 20 mm thick bedding layer in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
Material and labour for granite stone tiles dado 20mm thick machine cut in skirting/dado laid over cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing of mirror finish type including 15 mm thick screed in CM 1 :4 on brick or concrete surface complete all as specified and directed by Engineer-in-Charge.
Dismantling water tanks and removing to store of capacity n exc 500 ltrs complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 500 ltrs capacity Rotational moulded polyethylene water storage tanks trriple layer (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-Charge.
Taking down of old existing roof treatment of any description incl scrube and remove loose concrete, brick tiles, mud fuska, plaster, bitumen, oil grases and any other materials that might effect adhesion by wire brushing the surface and cleaning of the surface throughly with water and disposed off old materials from site and MOD Area complete all as specified and directed.
M&L for 50 mm thick cement concrete 1:2:4 type B-0 ( using 12.5 mm graded stone aggregate) as in padding/ base on roof complete all as specified and directed.
M&L for 20 mm thick plastering in CM 1:4 on RCC roof slab, finish even and smooth for receive water proofing APP membrane using WPC @ 3% by weight of cement complete all as specified and directed by Engineer-in-Charge. Note : WPC will be measured and paid separately.
M/L for preparation of the plastered roof surfaces and fix the APP polymeric water proofing membrane of minimum 3 mm thickness & weighing not less than 3.6 kg / sqm black finished reinforced with non-woven ployster 160 gsm matt with a thermofusible finish laid over primer conforming to IS:3384-1965 @ 0.5 kg/sqm and thereafter apply compitable hot blown bitumen 85/25 @ 1.20 kg/sqm torching overlaps with a propane or a butane gas torch with a overlap of 75 mm at the sides and 100 mm at the end sealing complete all as specified and directed by Engineer-in-Charge.
Disconnecting existing PVC tanks of capacity exc 250 & n exc 500 ltrers, setting aside (or lowering if required) for repairs, Cleaning and removing all scale and dirt, etc. from tanks and form mouths of circulating pipes, etc. and hoisting if required reconnecting and re-fixing the same in position and restore water supply to accommodation complete all as specified and directed by Engineer-in-Charge.
Disconnecting existing PVC tanks of capacity exc 500 & n exc 1000 ltrers, setting aside (or lowering if required) for repairs, Cleaning and removing all scale and dirt, etc. from tanks and form mouths of circulating pipes, etc. and hoisting if required reconnecting and re-fixing the same in position and restore water supply to accommodation complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair for 25 mm bore steel water tubing galvanised, medium grade fixed to walls and ceiling or in floor including taking down of old GI lines complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new or previously untreated plsatered or concrete surfaces and applying two coats of weather coat over a coat of primer complete all as specified and directed by Engineer-in-Charge.
S&F 1.25mm thickness of laths steel rolling shutters, without ball bearing as specified including top cover, anchoring rod, hasp, staple and including gear operated type with bevel gear box and crank handle for rolling shutters and one shop coat of primer erected in position as indicated, complete all as specified and directed by Engineer-in-Charge.
S&F Safety lever locks mild steel with 4 leavers for rolling shutters complete all as specified and directed by Engineer-in-Charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) any thickness, including cover fillets and grid frame work complete all as specified and directed by Engineer-in-Charge.
M & L anodised aluminium snap grid frame work of size 605 x605mm for false ceiling including hanger 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5 mm dia 40mm long complete all as specified and directed by Engineer-in-Charge.
M&L for 8 mm thick Exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid complete all as specified and directed by Engineer-in-Charge.
M&L for providing PVDF aluminium composite panels with fire resistent mineral filled core material as in interior/exterior wall cladding upto G+2 storeyed external wall surface shall consist of following complete all as specified and directed by Engineer-in-Charge. (I) Aluminium sheet making a total panel thickness of 6 mm with outer surface finished with PVDF based coating 0.25mm ,inner surface finished with a thin coat of polyster paint. The cleness of aluminium cover sheet shall be 0.50 mm inner core shall be of LDPE (II) aluminim framing of section 25 mmx50 mm x1.50mm thick , (III) aluminium grid shall not be exceed 1.0 sqm each the aluminium grid not more than 1 m c/c shall be fixed with MS angle 30x30x5 mm projected 150mm from surface of wall, (IV) Colour shall be approved by GE. (V) Joint shall be sealed with silicon weater proof sealing compound with help of masking Tapes. Note: Canopy,borders, projections etc will be measured in sqm for payment purpose.
M&L for cut outs/ metal sign board of dogs Size 1.2m X 1.5m PVDF aluminium composite panels with fire resistent mineral filled core material printed with vinayl OR print with 3 M retro reflective tapes on ACP Sheet fixed on the ACP Sheet with the help of high bond double side taps Of 3M Grey VHB taps 2 mm thick including taking down of old sign board complete all as specified and directed by Engineer-in-Charge. Note: coloure and Type of dogs choice shall be approved by GE.
M&L for 3d Stainless steel LED lighted letters OR print with 3 M retro reflective tapes on ACP Sheet above 12 inch including taking down of old ss letters complete all as specified and directed by Engineer-in-Charge. Note: Size shall be approved by GE.
M&L for Steel work in tubular trusses and purlins including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240
M&L for Structural steel, rolled section such as joist, beam, channel, angle, tee, in available lengths Fe 410-W(Gde-E-250) quality-A complete all as specified and directed by Engineer-in-Charge.
M&L for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed by Engineer-in-Charge.
Taking down carefully aluminium point wiring (light, Socket or power) complete including fittings and fixtures such as switches, ceiling roses pendents, regulators, sockets etc for taking credit to be measured separetly including making good the disturbed portion/surface complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with colour coding multistranded copper conductor cable, PVC insulated and (FRLS) unsheathed size 1.5 sqmm with PVC concealed Conduit ( dia not les than 25 mm) with fixing accessories for one light /fan/bell point controlled by one switch with pressed steel concealed terminal boxes covered with 3mm thick laminated sheet incl. contineous earth wire of PVC insulated unsheathed multi stranded copper conductor cable size 1.5 Sqmm for earth wire connected to common earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per item No 114 above but for one 3/5 pin socket 5 Amp on same board, with 1.5sq mm wire with 1.5sqmm earth wire.
All as per item No 114 above but for one 3/5 pin socket 5 Amp on independent board with 1.5sqmmwire with 1.5sqmm earth wire
All as per item No 114 above but for 3 pins socket outlet 15 Amps independent with 4.0 sq mm incl contineous earthing with multistandred copper conductor PVC insulated unsheathed size 4.0 Sq mm Note:- (For item 114 to 117 ) Cost making good disturbed surface below existing point wiring taken out vide item No 114 and cutting chases and making good of disturbed surfaces by cement & sand mortar (1:3) and surface finish as per adjustment surface conduit and all accessories as required for concealed point wiring vide item No 114 to 117 as applicable shall be deemed to be included in the unit rate quoted against these items.
M&L for point wiring with multistranded copper conductor cable, PVC insulated and unsheathed size 1.5 sqmm (FRLSH) drawn in and incl PVC casing and caping with fixing accessories for one light /fan point controlled by one switch with pressed steel concealed terminal boxes covered with 3 mm thick laminated sheet incl continous earth wire of PVC insulated unsheathed multi stranded copper conductor cable size 1.5 Sqmm for earth wire connected to common earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per item No 118 above but for one 3/5 pin socket 5 Amp on same board.with 1.5 sqmm wire with 1.5sqmm earth wire
All as per item No 118 above but for one 3/5 pin socket 5 Amp on independent board.with 1.5 sqmm wire with 1.5sqmm earth wire .
All as per item No 118 above but for 3/5 pins socket outlet 15 Amps independent with 4.0 sqmm incl continous earthing with multistandred copper conductor PVC insulated unsheathed size 4.0 Sqmm
S&F switch piano flush type/Bell push, 5 Amps, single pole one way 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F socket 3/ 5 pins, 6 Amp, flush type piano (multi purpose) 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F Socket 15 Amps flush type,3/ 6 Pin, 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F switch 15 Amps flush type 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F Modular switch flush type, 5/6 Amps, single pole one module white colour 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F Modular switch flush type, 15/16 Amps, single pole one module white colour 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F Modular socket 3 pins combined, 5/6 Amp, flush type (multi purpose) two module ,230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F Modular socket 5 /6 pins combined, 15A/16 Amp, flush type(multi purpose) two module 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F Modular white cover plate with frame suitable for three module way 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F Modular white cover plate with frame suitable for four module way 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F Modular white cover plate with frame suitable for six module way 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F Ding Dong door bell 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F Bell push flush type 5 Amps, single pole one way 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F Modular Bell push flush type 5 Amps, single pole one way 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F ceiling rose, PVC / Polycarbonate isolated body ,surface backlite, 65x50mm, three terminals, 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F modular stepped type electronic fan regulator flush type,2-way 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F stepped type electronic fan regulator flush type 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F Batten holder PVC/Polycarbonate base / back suitable for LED lamp. 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F LED Bulbs 9/10W B-22 Pin type 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S& F PVC Combination Box type complete with switch & socket 5/6 Amp ,230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S& F PVC Combination Box type complete with switch & socket 15/16 Amp. 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S& F plug top of 16 Amp, 3 Pin 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S& F plug top of 05 Amp, 3 Pin 230 Volts , ACcomplete all as specified and directed by Engineer-in-Charge.
S& F AC plug to of 20 Amp, 3 Pin suitable for AC Box (sheet metal enclosure with a two pin and earth plug and socket ) 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S& F AC socket of 20 Amp, 3 Pin suitable for AC Box (sheet metal enclosure with a two pin and earth plug and socket ) 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole 20 amps MCB complete all as specified and directed by Engineer-in-Charge.
S&F Skylite recess mounting,36W, LED 2'x2' luminaire integrated electronic driver, optics diffused, complete including electrical connection with copper cable from ceiling rose to fittings and taking down old Unserviceable light fittings of any type and any size complete all as specified and directed by Engineer-in-Charge.
S&F LED tube light fittings 20W (4 feet) wall mounted LED batten extruded PVC heat sink provided for efficient heat dissipation & integrated electronic driver optics diffused complete including electrical connection with copper cable from ceiling rose to fittings and including taking down existing fittings complete all as specified and directed by Engineer-in-Charge.
S&F LED 6000K (2’ feet), 10W Decorative LED lighting fixture with extruded PVC . heat sink, environmental friendly, energy efficient ready to use pack, complete and including taking down existing fittings complete all as specified and directed by Engineer-in-Charge.
S&F LED bulkhead luminaire 10W decorative type as per sample complete including electrical connection with copper cable from ceiling rose to fittings and including taking down existing fittings complete all as specified and directed by Engineer-in-Charge.
S&F LED building secuity light 25 watt made up of pressure die cast aluminium housing with mid power LED as lightening source and PC cover having top opening inbuilt LED driver with IP66 protection and impact resistance of IK-07 complete including GI bracket with nut bolts, washers etc including electrical connection with copper cable from ceiling rose to fittings and including taking down existing fittings complete all as specified and directed by Engineer-in-Charge.
M&L for submain wiring with 2X6.0 SQMM+1X6.0SQMM Earth Wire single core PVC insulated FRLSH sheathed copper cable connecting to common earth dolly in and including heavy duty PVC casing caping and dismantling and taking down existing unserviceable wiring, all accessories complete all as specified and directed by Engineer-in-Charge.
M&L for submain wiring with 2X6.0 SQMM+1X6.0SQMM Earth Wire single core PVC insulated FRLS sheathed copper cable connecting to common earth dolly in and including heavy duty PVC concealed Conduit 25mm dia and dismantling and taking down existing unserviceable wiring, all accessories complete all as specified and directed by Engineer-in-Charge. Note:- Cost making good disturbed surface below existing point wiring taken out vide item No 153 and cutting chases and making good of disturbed surfaces by cement & sand mortar (1:3) and surface finish as per adjustment surface conduit and all accessories as required for concealed point wiring vide item No 153 to 154 as applicable shall be deemed to be included in the unit rate quoted against these items.
S&F in repairs VTPN 4 way double door prewired distribution board TPN-DPX 125 MCCB including one No MCCB 125 Amps, 25 kA, 4 pole as incomer and suitable SPN/TP MCBs as outgoing double door type sheet metal enclosure 415V with 200 Amps rated standard busbar of suitable size plate and common neutral link without MCBs with blank plate suitable for 4 way complete and including taking down VTPN DB's all as specified and complete all as specified and directed by Engineer-in-Charge. Note : Rates of MCCB and MCB SPN/SP/TP shall deemed to be included in the quoted rates.
S&F in repairs Distribution board 4 way TP&N Double Door are fitted with Bus Bars, Neutral Links suitable for 415V, 50Hz, Blanking Plates, Suitable for TP/FP MCB complete all as specified and directed by Engineer-in-Charge.
S & F in repairs single pole and neutral sheet metal enclosures for Distribution board (DB's)suitable for MCBs fitted with bus bar , Neutral link ,Earth Bar and Din rail 240 V, 50 Hz supply double door SP&N DB system 12 ways complete all as specified and directed by Engineer-in-Charge.
All as per item No 157 above but 8 ways
S&F MCB TPN 63 to 100 AMPS Amps 415V incl all termnials, fitting etc including taking down complete all as specified and directed by Engineer-in-Charge.
S&F RCBOs for earth leakage,over load & short circuit protection 2 pole ,25 Amp rating, 300 mA capacity suitable for 240 Volts and including taking down existing MCB/ RCCB complete all as specified and directed by Engineer-in-Charge.
S&F MCB SPN 40-63 Amps 240V incl all termnials, fitting etc. including taking down complete all as specified and directed by Engineer-in-Charge.
S&F MCB SP 06 to 40 Amps 240V incl all termnials, fitting etc including taking down complete all as specified and directed by Engineer-in-Charge.
M&L for rewinding of exhaust fan of size 250 to 600 mm sweep Including Taking down ,dismantiling, opening ,descaling, adjustment, re fixing , cleaning, greasing, painting, replacing minor spares (ie nut, bolt,washers) and rewinding with proper size enamelled copper wire warnishing (spares mentioned below will be measured and paid separatelly) complete all as specified and directed by Engineer-in-Charge.
Ball bearing
Brass bushes
GI Exhaust fan louvers complete with nut & bolts etc.
Mettalic Exhaust fan blade of any sweep with screws/bolts, nuts.
M&L for servicing,Taking down Ceiling fan , Air circulator & wall mounted fans any size and any sweep removing cleaning of dust, properly cleaning greasing of bearing incl replacing any defective part and connecting up complete all as specified and directed by Engineer-in-Charge.
M&L for rewinding of Ceiling fan , Air circulator & wall mounted fans of any size any sweep and any capacity of fans using super enameled copper conductor of suitable gauge including insulation varnishing, packing including taking down and refixing the fans in original position complete all as specified and directed by Engineer-in-Charge. (Note: spares mentioned below will be measured and paid separatelly)
Ball bearing
Brass bushes
2.5 to 3.0 mfd capacitor
M & L for replacement of running cap 4.0 MFD 440 volt complete all as specified and directed by Engineer-in-Charge.
M & L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick burried directly in gorund (earth pit not less than 2.25 Mtr normal ground level),and top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised means of earth wire 4 mm dia with bolts, nuts & check nuts, and washers of galvanised iron protection pipe light grade of 15 mm dia and watering pipe medium grade of 20 mm dia and filled with alternate layer of charcoal and common salt, watering funnel with wire mesh, earth pit chamber and cover CI frame PCC 1:3:6 type C-2 all as shown in electrical plate No-3 of SSR part-I of 2009 connected to earthing test point all as specified and indicated including all earth work excavation, returning filling and disposal of surplus soil and testing on completion complete all as specified and directed by Engineer-in-Charge.
M & L for servicing of desert cooler of any capacity at existing location by cleaning of all components with Rinse solution & clean water, greasing of fan, motor including cleaning of water storage tank with treated water after applying the potassium permanganate solution etc without damage any parts incl replacement of small parts like PVC water distributer, flexible pipe, plugs etc as required on site complete all as specified and directed by Engineer-in-Charge.
M & L for scraping and removing old paint of desert cooler body (steel surfaces) and preparation of steel surfaces including necessary denting, cutting, welding etc for spray painting with approved smoke gray synthetic enameled paint (Ist quality) over a coat of Zinc chromate primer on outer surface and inner surface i.e. Water tank and body fan mounting blades shall be painted with a coat of anticorrosive black paint over a coat of Zinc chromate primer complete for desert cooler of any size and capacity complete all as specified and directed by Engineer-in-Charge.
S & F in replacement Desert cooler Pump as per existing capacity complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of cooling fan motor supporting legs and PVC fan blade of 450 mm sweep for desert cooler complete all as specified and directed by Engineer-in-Charge.
M & L for rewinding of desert cooler motor of any make with supper enameled copper wire (Thermal class E) of appropriate size including replacement of gun metal bushed and steel shaft complete all as specified and directed by Engineer-in-Charge.
M & L in replacement of 01 No front grill and 3 side louvers suitable for disert cooler duly spray painted with approved paint over a coat of red oxide primer and internal surface of body cooler pump and motor shall be painted with two coat of bituminous paint over a coat of red oxide primer as required on site complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Desert cooler motor copper wound 230 v ,150 watt and 130 rpm complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of desert cooler body 660x660x900mm with front grill and three side louver fabricated out of 22 gauge mild steel plan black sheet and bottom water tank (sump) of size 660x660x200mm deep fabricated out of 20 gauge milled steel plan black sheet including taking out and reinstallation complete with standard fitting such as PVC pipe for water electric controls and switch, fan speed regulator rewiring of fan motor and water lifting pump including fixing and connecting existing cooler fan and electric pump with 3 core PVC insulated & PVC sheathed cables (min3 mtr in length). External surface shall be spray painted with approved paint over a coat of red oxide primer and internal surface of body cooler pump and motor shall be painted with two coat of bituminous paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of wood wool pad 25mm thick duly winded with the nylon mesh of standard size for 4000 cum/hr capacity desert coolers complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of rotary switch as requirement at site complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of PVC water distributer flexible pipe with TEE and all accessories in desert cooler complete all as specified and directed as requirement at site complete all as specified and directed by Engineer-in-Charge.
M&L for Exhaust fan motor for 300 mm sweep ( as per suitable for exixting)complete all as specified and directed by Engineer-in-Charge.
36SHRI RADHEY ASSOCIATES
laxmi enterprises
Singh Associates
M/S Ashoka Engineers and contractors
PG CONSTRUCTION AND COMPANY
Gaurav India Corporations
M/s Kapil Furniture
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .