Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67.9 LAccepted-AOC 23 A MORAR ENCLAVE GOLA KA MANDIR MORAR GWALIOR MP 474005 | GWALIOR | GWALIOR | MP | 474005 | L1 | Accepted-AOC Being a lowest | |
| 2 | L2₹74.8 L+₹6.2 L (9.02%)Rejected-Finance RAVI KIRAN MARKET JIWAJI CHOWK BADA LASHKAR GWALIOR M P 474001 | GWALIOR | GWALIOR | MADHYA PRADESH | 474001 | L2 | Rejected-Finance Not a lowest tender | |
| 3 | L3₹75.3 L+₹6.6 L (9.61%)Rejected-Finance 42 MORAR ENCLAVE GOLA KA MANDIR GWALIOR | GWALIOR | GWALIOR | MADHYA PRADESH | 474005 | L3 | Rejected-Finance Not a lowest tender | |
| 4 | L4₹77.0 L+₹8.3 L (12.2%)Rejected-Finance | L4 | Rejected-Finance Not a lowest tender | |
| 5 | L5₹86.4 L+₹17.7 L (25.8%)Rejected-Finance | L5 | Rejected-Finance Not a lowest tender |
Tender Value
₹94.3 L
EMD Value
₹1.7 L
Closing Date
10 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF Gwalior
Air Force Gwalior
ADDITION ALTERATION TO WHEEL SERVICING BAY GAS TURBINE STARTER AND FUEL SERVICING BAY AT AF STN GWALIOR
2020_MES_353021_2
84081/E8
Open Tender
Civil Works
Item Rate
270 days
GE AF TA GWALIOR
As per tender documents
7 documents required · 7 mandatory
₹1,000
GE AF Tech Area Gwalior
₹1.7 L
Yes
29 Sept 2020
6 Aug 2020
15 Sept 2020
6 Aug 2020
10 Sept 2020
24 Aug 2020
6 Aug 2020 - 15 Aug 2020
60 days
Amount
Demolition of plain cement concrete (unreinforced) of any mix / grade in ground floor and pavings not exceeding 15cm thickness (below or above ground level) including removal of debris out off the AF station premises / MOD land etc complete all as specified & directed .
Dismantling, floor, hearth or wall tiling including cement mortar bedding complete and removing rubbish off from the premises complete all as specified and directed.
M & L for 25 mm thick plain cement concrete 1:2:4 type B-0 (using 12.50 mm graded crushed stone aggregate) as in sub floor etc surface finished even and rough to receive the topping etc complete all as specified & directed.
M&L for premium quality non skid coloured ceramic joint less floor tiles 7-8 mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc set & jointed in neat cement slurry and pointed in cloured cement to match the shade of tiles ,over & including 20 mm thick screed bed in cement mortar (1:4) complete all as specified & directed.
M&L for endura heavy duty coloured tiles 20mm thick (Square/ rectangular) size 300 mm x 300 mm x 20mm thick in floors etc. , laid over and including adhesive as per manufacturers instructions complete and pointed in coloured cement to match with shade of tiles complete all as specified and directed.
M&L for Vetrified dark shed ceramic floor tiles 10 mm thick (Square/rectangular) area of each tile not exceeding 0.36 Sqm, in floors etc set & jointed in neat cement slurry and pointed in cloured cement to match the shade of tiles over & including 20 mm thick screed bed in cement mortar (1:4) etc complete all as specified & directed.
M&L for Vetrified dark shed ceramic tiles 10 mm thick (Square/rectangular) area of each tile not exceeding 0.36 Sqm on vertical surface such as skirting / dado etc ,set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over & including 10 mm thick backing coat in cement mortar (1:4) etc complete all as specified & directed.
M&L for glazed ceramic coloured tiles 450 mm X 300 mm X 6 to 7 mm thick on vertical surface such as skirting / dado etc ,set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles including 10 mm thick backing coat in cement mortar (1:4) etc complete all as specified & directed.
M&L for 20 mm thick granite of approved type / variety (table rubbed and pre mirror polished) in window cill, jambs, steps, and cooking platforms including pointing in coloured cement to match with shade of granite including half moulding of granite edges over & including 20 mm thick screed bed in CM(1:4) for laying of granite slab etc complete all as specifed and as directed.
M&L for 20 mm thick granite of approved type / variety (table rubbed and pre mirror polished) in vertical surface for wall lining (veneering to wall ) including pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M & L for 75mm thick PCC (1:3:6) type C-1 ( using 20mm graded crushed stone aggregate ) as in plinth protection laid in panels and joints filled with mix of bitumen and sand (1:3) by weight, finished the surface even and fair complete all as specified and directed.
Cutting channels, grooves or rebates exceeding 15cm but not exceeding 30 cm girth, and trimming surface where reinforcement is cut through complete all as specified and directed.
Demolition of brick work of any description and in any position built in cement or cement lime mortar including all quoins, arches, pillars including segregation of serviceable bricks for reuse & removal of rubbish out off the AF station premises / MOD land etc complete all as specified and directed.
M&L for Brick work with using old size sub class "B' bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 etc complete all as specified & directed.
All as per Sl item No. 14 here-in -before but except bricks complete all as specified & directed. Note : Bricks retrived from respective items (DEMOLITION ITEMS) of BOQ.
S&F mild steel galvanised powder coated suspended false ceiling system with grid of size 605mm x 605mm, consisting of mild steel galvanised powder coated main runner of size 24mm x 32mm and cross Tee of size 24 mm x 27 mm and wall angle of size 22.2 mm x 22.2mm, suspended with 4 mm dia GI wire hanger at 1200 mm spacing, fixed with steel dash fasteners or from purlin of roofs with butterfly clips etc including 12mm thick gypsum board ( Semi perforted) in ceiling fixed to GI snap grid frame work with hold screws, of any height upto 8.5m with adjustable cleat of J- hook including making provision for housing light fitting, AC grills etc complete including fixing, re-fixing false ceiling lights, wastage T&P as per manufacturer's instructions and complete all as specified and directed by Engr-in-Charge complete all as specified..
Taking down cement plaster of brick or stone masonry etc including raking out joints , hacking for key & scrubbing down with water etc complete all as specified & directed.
M&L for complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means, including filling depressions of scrapped surfaces with preparation of plastered surfaces complete all as specified and directed.
M&L applying two coats of distemper oil emulsion (OBD) over a coat of cement wall primer and a layer of wall care putty not less than 2mm thick (from same manufacturer of OBD) complete all as specified and directed.
M&L for rendering 5 mm thick in cement mortar (1:3) on concrete surface of ceiling finished even and smooth without using extra cement complete all as specified & directed.
M&L for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick / external surface of masonry wall using liquid water proofing compound mixed by weight of cement as per manufacturers instructions surface finished fair & even complete all as specified and directed. (Note: WPC will be measured & paid separately under respective item of BOQ )
M&L for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick work or concrete surface , finished fair & even complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar (1:6) on other than fair faces of brick masonry wall / concrete surface finished fair and even etc. complete all as specified and directed.
M&L for preparation of new plasterd surfaces of walls and apply two coats of distemper oil emulsion (OBD) over a coat of cement wall primer (from same manufacturer of OBD) over and including a layer of wall care putty not less than 2 mm thick etc complete all as specified and directed.
M&L for preparation of newly plastered external surfaces of wall including cornices pilasters and apply two coats of exterior acrylic weather proof antifungal emulsion paint of approved brand and shade over one coat of alkali primer all as per manufacturers instructions including necessary scaffolding etc complete all as specified and directed.
M&L for complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means, including filling depressions of scrapped surfaces with preparation of plastered surfaces of existing external surfaces of walls and apply two coats of exterior acrylic weather proof antifungal emulsion paint of approved brand and shade over a coat of alkali primer all as per manufacturers instructions including necessary scaffolding etc complete all as specified and directed.
M&L for preparation of newely plastered surfaces of ceiling and applying three coats of white wash on ceiling complete all as specified & directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc), or insulation boards/slabs/blankets, any thickness any type including cover fillets, complete all as specified & directed.
M&L acoustic foam wall panelling using 50 mm thick tiles of size 30 cm x 30cm or 60 cm x 60cm with NRC > or equal to 0.9 made of Acoustix polyurethene of approved colour density 40 Kg/cum fixed to walls using SR adhesive or spray adhesive complete all as specified & directed. Make : MMT ACCOUSTIX/ ARMSTRONG
Complete removal of existing roof treatment any thickness including plastering, leaping plaster of any thickness cutting & up rooting tree roots/Vegitable growth & removing the debris outside the MOD land including cleaning/washing down and keeping surfaces clean complete all as specified and as directed.
M&L for plain cement concrete 1:2:4, type B-0 (using 12.50 mm graded crushed stone aggregate) 25 mm thick to maintain proper slope as in roof padding for levelling course etc. complete all as specified and directed
M & L for 10 mm thick screed bed in cement mortar 1:4 mixed with using liquid water proofing compound as per manufacturers instructions (note:Water proofing compound shall be measured and paid seprerately under respective item of "BoQ") over roof top surface finished even and smooth using extra cement and application of water proofing treatment using APP modified roof membrane over existing inaccessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.30 litre / Sqm manufactured by the same agency as that of APP membrane with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Physical property of membrane shall be as under :- (i) Membrane weight not less than 3.60 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gsm/Sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650 Kg / Sqcm and transverse not less than 450 Kg /Sq.cm at 230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N & transverse not less than 250N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 Kg/Sqcm. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap. (Note:- WPC shall be measured and paid separately)
Supply only polymer liquid water proofing compound of approved make all as specified & directed
Demolition of plain cement concrete (unreinforced) of any mix / grade in other than ground floor and pavings not exceeding 15cm thickness (below or above ground level) including removal of debris out off the AF station premises / MOD land etc complete all as specified & directed .
M&L for plain cement concrete (1:2:4) type B-1 ( using 20 mm graded crushed stone aggregate ) as in coving on chajja, balcony or in roof Kerbs, benching,coping , bed plates for fixing hold fast ,rounded or chamfered on edges and similar work including necessary formwork complete all as specified and directed.
Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, chajjas, staircases, landings and similar suspended work (reinforcement cut as required to facilitate demolition) including removal of debris out off the premises / MOD land complete all as specified & directed.
Use & waste of form work to soffits of suspended slab such as roof slabs, landings and similar work etc. not exceeding 200 mm thick for rough finished flat surfaces of concrete complete all as specified and directed.
Use and waste of form work to sides and soffits of floor or roof beams, lintels, cantilevers, shelves including supports for flat, for rough finished surface of concrete complete all as specified and directed.
Use & waste of form work to soffits of chajja,chullah hoods,troughs and similar including edges for rough finished flat surfaces of concrete complete all as specified and directed.
Use and waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor & roofs and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide rough finished surface of concrete complete all as specified and directed.
Use and waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 05 cm but not exceeding 10cm wide rough finished surface of concrete complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over grade Fe-500, cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed.
M& L for mild steel TMT bars 8 mm dia grade Fe-500, cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed.
M&L for mild steel TMT bars 08 mm dia and over grade Fe -500 , as in stirrups, spacers & binders ,cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed.
M & L for reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in slab supported on wall and beams coloumns in floor, roofs ,landing, balcaonies & shelves and similar works etc.complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in chajja etc. complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in beams, cantilevers, bressumers, lintel over 1.5m span complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
M&L for providing pre-cast cement concrete M-25 (design Mix) (using 20mm graded crushed stone aggregate) as in cover slab , RCC flatform set in cement mortar 1:4 etc for cable duct and base for antena or similar work etc complete all as specified and directed. complete all as specified and directed. (Note : Reinforcement shall be measured and paid seperately under respective items of BOQ)
Taking down chowkats or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frames) including builders hardware etc complete all as specified & directed.
Taking down chowkats or frames with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) etc including builders hardware etc complete all as specified & directed .
S & F UPVC luxury casement sound proof fixed window frame and glazing 65mm/C65PS3/Z-SASH, DG INS, TGH (6T+12+6T) with cylinder of one side key, one side thumb turn and locking system including necessary builders hardware etc complete weight not less than 32 Kg/Sqm all as directed. Make : FENESTA/ KOMMERLING
S&F UPVC luxury casement sound proof door frame with single shutter and glazing 65mm/C65PS3/Z-SASH, DG INS, TGH (6T+12+6T)mm with cylinder of one side key, one side thumb turn and locking system including necessary builders hardware etc complete weight not less than 31 Kg/Sqm all as directed. Make : FENESTA/ KOMMERLING
S&F UPVC luxury casement sound proof door frame with double shutter and glazing 65mm/C65PS3/Z-SASH, DG INS, TGH (6T+12+6T)mm with cylinder of one side key, one side thumb turn and locking system including necessary builders hardware etc complete weight not less than 32 Kg/Sqm all as directed. Make : FENESTA/ KOMMERLING
S&F for powder coated aluminium deco grills size 4mmx4mm, 8mm thick and aperture not exeeding 80 mm width and including fixing with aluminium channel, 1 mm thick with steel screw and tint match with existing complete including taking down existing grill complete all as specified and as directed.
S&F for Powder coated anodised aluminium door with door frame of size 101.6mmX44.75mmX2.4mm thick (wt @ 1.834 Kg/m), shutter with styles 47.62mmX44.45mmX2.02mm thick (wt @ 1.052 Kg/m), top rails 47.62mmX44.45mmX1.95mm thick (wt @ 0.974 Kg/m), intermediate rail 100mmx45mmx2mm thick (wt @ 1.603 Kg/m), bottom rail 101.6mmx44.5mmx2.5mm thick (wt @ 1.943 Kg/m) including 6mm thick glass of make Modi/Atul and partly/fully fixed with 12mm thick prelaminated particle board fixed with aluminium snap beading and rubber gasket. Each shutter shall be fitted with one aluminium sliding bolt of 250mm, 02 nos tower bolt 200mm , 02 nos handle complete all as specified and as directed. Note: (i) Drg No. CE/ALD/TD/224 Sheet No. 1/1 (ii) Each door size not exceed 2.0Sqm.
S&F for powder coated anodised aluminium partition frame of size 101.6mm x 44.5 mm x 3 mm on top and bottom and middle rail, vertical rail 101.6 mm x 44.5 mm x 3mm thick, standard channel at bottom 40x20x3mm and clip for fixing 5.5mm tinted glass etc and partly/fully fixed with 12mm thick prelaminated particle board fixed with aluminium snap beading over and including all necessary fittings of approved make complete all as specified and as directed. (Note:Each panel shall not exceed 1.40 Sqm)
S&F in repair for floor spring to aluminium door including removing the door and fixing in the same position complete all as specified and as directed.
S&F in repair for rubber beading to aluminium door including removing of old beading and fixing new beading complete all as specified and as directed.
S & F for factory made Solid PVC door frame of size 50mmx 47mm made out of 5mm thick plain colour PVC sheet reinforced with mild steel square tube, as per manufacturers specification complete all as specified and directed.
S & F for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of mild steel tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail & bottom rail. Paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent complete all as specified and directed.
S&F for stainless steel hinges of 100 mm long for PVC door shutter complete all as specified and directed.
S&F for stainless steel 200 mm long tower bolt for cabinet & cup board shutter etc.complete all as specified & directed.
S&F for stainless steel handles of 150 mm long for shutter etc complete all as specified and directed.
S&F for 300 mm long stainless steel sliding door bolts( bolt type ), with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts and fixed complete all as specified and directed.
S&F for door closer hydraulical regulated designation No 3 Universal type suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg and fixed cast iron body complete all as specified and directed.
Taking down evaes gutters and rain water pipes (any size or pattern) including all fitting heads shoes bends swan necks etc, including removal of pipe out off the AF station premises / MOD land complete all as specified and directed.
S&F for PVC (SWR) pipes (ISI marked), single socketed in any length with rubber ring joints, fixed to wall , 110 mm bore complete all as specified and directed.
S&F for PVC (SWR) pipes (ISI marked), single socketed in any length with rubber ring joints, fixed to wall , 160 mm bore complete all as specified and directed.
S & F 110mm dia PVC (SWR) (ISI marked) bends any radius complete all as specified and directed.
S & F 160mm dia PVC (SWR) (ISI marked) bends any radius complete all as specified and directed.
S & F 110mm dia PVC (SWR) vent cowl (ISI marked) complete all as specified and directed.
S & F 160mm dia PVC (SWR) junction single (Single T) equal or unequal (ISI marked) complete all as specified and directed.
Dismantling structural steel work including doors, windows, gates but excluding framed truss etc.complete all as specified and directed.
S&F for mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks, frame work for ceiling , frame work for chimney and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L for prepartion of new or previously untreated steel surface of any description , not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed.
Taking up or down steel tubing and connections 15 mm bore, including removing from site complete all as specifed & directed.
Taking up or down steel tubing and connections 20 mm bore, including remove from site complete all as specifed & directed.
S& F for GI water tubing medium grade, ISI marked, galvanised, 15 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors complete all as specifed & directed.
S&F for GI water tubing medium grade, ISI marked, galvanised, 20 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors complete all as specifed & directed.
M&L for cutting chases , pinning in brick walls making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, shelves, lintels, etc, and cutting chases for concealed water tubings or conduit wiring, etc and making good, cutting not exceeding 10cm girth complete all as specified and directed.
S&F for rotational moulded polythene water storage tank of capacity 1000 ltrs (Cylindrical/vertical with closed type), triple layer construction, ISI marked, hoisted and fixed in position including 20 mm bore GI medium grade over flow ( 450mm long) and washout pipe (600 mm long )with fittings including dismanling of existing tank and lowering down etc complete all as specified and directed.
S&F in repair 20 mm bore ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 210 gms) complete all as specified & as directed.
S&F in repair gun metal globe or gate valves(ISI marked), with iron wheel head, screwed both ends for iron pipe 20 mm bore complete all as specified and directed.
S&F in repair gun metal globe or gate valves(ISI marked), with iron wheel head, screwed both ends for iron pipe 15 mm bore complete all as specified and directed.
S&F in repair toilet paper holder, vitreous China, box type coloured complete all as specified and directed.
S&F in repair PVC connection 15 mm size 600mm long with PTMT nut complete all as specified and directed.
S&F in repairs vitreous China wash down water closet (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe), fixing seat cover including connection to drain (or outgoing pipe, and to flushing pipe & antisyphonage pipe etc with aluminium hinging device complete all as specified and directed. Note : Plastic seat cover shall be measured separately as Supply only as considered under respective items.
Supply only plastic water closet seat with closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device complete all as specified and directed.
S&F for vitreous china urinal full bowl type urinal complete including providing and fixing plugs bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with & including 60 mm brass screws pointing around urinal back in cement fixing automatic flushing cistern with brackets flush pipe grating and union for discharge pipe complete all as specified and directed. complete all as specified and directed.
S&F for PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including ball valve float and handle, PVC flush pipe 32 mm bore & PVC connection 15 mm bore 450 mm long with PTMT nuts and brackets complete set all as specified and directed.
S&F in repair cast copper alloy chromium plated fancy type angular stop cock (ISI marked) with flange of size 15 mm bore complete all as specified and directed.
S&F in repair 15 mm bore bib taps (ISI marked), cast copper alloy with capstan head, chromium plated fancy type with long body shank, screwed down with high pressure screwed for iron pipe and fixed complete all as specified & directed.
S&F in repair 32 mm brass chromimum plated bottle traps for wash basins with inlet and out let screwed for pipes or connections including necessary packing union cap complete all as specified and directed.
S&F in repair sheet glass self assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket gurd and railing 60 cm long all as specified and directed.
S&F in repair soap dish of vitreious China, white size 160mmx160mmx190mm embedded to wall complete all as specified and as directed.
S&F in repair 100 mm cast iron floor trap including jointing to waste pipe fixed in cement concrete type B-1 1:2:4 (using 20 mm graded crushed stone aggregate) complete all as specified & directed.
S&F in repair grating doom 100 mm dia of PTMT (Minimum weight 25 gms) complete all as specified and directed.
S & F in repair vitreous China counter type wash hand basin white flat back size 560 mmx455mm fixed on and including brackets, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe (rigid quality) including PVC connection 15 mm size with PTMT nuts of length 800 mm & fixing of tap etc. etc.complete all as specified and directed. Note :- Pillar tape shall be measured & paid seperately as supply only under respective item of BOQ". MAKE: Parryware/ Cera/ Hindware
Supply only pillar tap cast copper alloy with capstin heads chromimium plated fancy type screwed down high pressure with or without lettered hot or cold with long screwed shank and fly nuts, screwed for iron pipe 15 mm bore complete all as specified and directed.
S&F in repar chromium plated brass tubular towel ring fixed with CP screws and wood cleats with wall complete all as specified and directed. MAKE: Jaquar/ KOHLER/ MARC
S&F in repair chromium plated towel rack 600mm long with lower hangers fixed with CP screws and wood cleats with wall complete all as specified and directed. Make: Jaquar / KOHLER/ MARC
S & F in repair chromium plated health faucet with 10 mm dia, 1.0 m long flexible tube and wall hook including PVC connection 15 mm size, & 900 mm long with PTMT nuts & washer to GI pipe or stop valve for E. W.C complete all as specified and directed . Make: Jaquar/ KOHLAR/ MARC
S&F for 50 micron solar control film non-reflective type sticked to glass panes as per manufacturer's instructions complete all as specified and directed.
S&F of Mortice lock, with handle vertical type, size 65 mm four levers (ISI marked) complete all as specified and directed.
M&L double action floor spring hydaulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of aluminium, other parts made of mild steel heavy duty and fixed in floor including cutting of floor for fixing of machine and make good in affected area complete all specified and directed
S&F for 4.50 mm thick Linoleum, plain coloured, laid in floors including stretching, cutting and fitting with and including sealed down with an approved adhesive complete all as specified and directed.
Cutting existing flooring with diamond cutter of depth exceeding 30 cm but not exceeding 45 cm and removing away rubbish from site complete all as specified and as directed.
M&L for plain cement concrete 1:1.5:3 (using 20 mm graded crushed stone aggregate) as in ramp/ path /hard standing floor including use & waste of form work to divide the area in panels & finshing concrete topping even & fair using extra cement etc complete all as specified & directed.
M&L for forming 12mm wide expansion joints to full depth of slabs, and filled with compressible rubber filler board (silflex dura board HD 100 of supreme make or equivalent) and providing a back up rod/debonding strip and top 12mm primed and sealed with polyurethane based sealing compound complete all as specified and directed.
M&L for forming contraction/dummy joint 10 mm wide x 65 mm deep primed and providing a back up rod/debonding strip and top 10mm primed and sealed with and using polyurethane based sealing compound with suitable primer as per manufacturer's recommendation complete all as specified and directed.
M & L for providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed.
M & L for treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.
S&F for water spray gun 75mm with 1.0 metre flexible pipe with wall hook of Jaquar/ KOHLER/ MARC complete all as specified and directed.
M&L for Frosted Matt acrylic Plexiglass DIY projects 3mm sheet fix on ventilators/window with aluminium frame work complete all as specified and directed.
Repair, maintenance of existing rolling shutter of any description and in any position including taking down existing rolling shutter, removing hood covers, ascertaining serviceability of existing parts, removing unserviceable parts and replacement with new one, fixing the existing serviceable parts in their position for ensuring smooth functioning of the rolling shutters of size 3.6 x 4.5m including greasing, oiling etc and replacement of minor parts like screws, nut, bolts, washers etc and fixing the parts (new or old) in existing position with necessary welding, reveting etc complete all as specified and directed by Engineer-in-Charge. Note : Supply only new parts shall be measured and paid separately under appropriate items of BOQ' and fixing and testing charges of these items shall be deemed to include in the unit rate quoted by the contractor.
Supply only flat spring suitable for rolling shutter upto height 4.5m (spring wt not less than 7 Kgs each) complete all as specified and directed.
Supply only 40mm dia (nominal bore) length suitable for rolling shutter up to 4mtr wide medium weight mild steel pipe as in suspension shafts complete all as specified and directed.
Supply only hood covers made of 1.0mm thick mild steel plain black sheet, cut to size, holes, punched and spot welded to steel including bending or turning, mitred single etc as required complete all as specified and directed.
Supply only mild steel spring wheel of any size with MS bush fixed with shaft for rolling shutters complete all as specified and directed.
Supply only fabricated bracket plate of mild steel sheet 3.15mm thick size as per IS for height upto 4.5m and shape not exceeding 0.50 Sqm for mechanically operated rolling shutter complete all as specified and directed.
Repair & maintenance of existing safety lever locks mild steel with four levers for rolling shutters complete all as specified and directed.
Supply only Ball bearing for rolling shutters complete all as specified and directed.
S&F for stainless steel sheet 2B finish, thickness 1.25mm material grade 304 as in chimney flue pipe complete all as specified and directed. (Note : Frame work for chimney with angle iron to be measured and paid separately in respective item of BOQ)
S&F for Cowls (with stays), riveted to and including 15 cm length of flue pipes of stainless steel sheet suitable for chimney area n. exc 0.40 sqm of flue pipe complete all as specified and directed.
S&F square/ rectangular steel tubular sections including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS 1161 1979 Grade Fe-290 complete all as specified and directed. Note: Drawing & design shall be approved by GE.
M & L for applying one coat of synthetic enamel paint on old steel surfaces of any description, over 10 cm width or girth including preparation of old steel surfaces complete all as specified and directed.
Surface excavation not exceeding 30cm deep and averging 27cm deep and getting out in soft /loose soil etc complete all as specified and directed.
Removing excavated material (soil) to a distance material exceeding 250 mtr but not exceeding 500 mtr and depositing where directed at a level not exceeding 1.5m above starting point complete all as specified.
M&L for hard core of broken stone or boulder gauge not exceeding 63mm deposited, spread & leveled in layers not exceeding 15cm thick, watered and rammed to a true surface etc complete all as specified& directed.
M&L for plain cement concrete (1:4:8) type D-2 (40 mm graded crushed stone aggregate) as in sub base of flooring complete all as specified and directed.
M&L for 12 mm thick forming expansion joint and 150 mm deep ( thickness of concrete slab) , joints filled with pre-formed bituminious filler and top 30 mm primed and sealed with sealing compound "Grade-B" complete all as specified & directed.
M&L for forming construction joint 30 mm deep X 10 mm wide filled with sealing compound "Grade-B" complete all as specified & directed.
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in hard/ dense soil.soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. complete all as specified and directed by Engineer-in-Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed & tested complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
M&L for plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) in foundation, filling and mass concrete etc complete all as specified and directed.
M&L for brick work with sub class "B" bricks built in cement mortar 1:6 straight or curved on plan exceeding 6.0 mean radius complete all as specified and directed.
M&L for reinforced concrete pipes, class NP-2, 300 mm bore, laid and jointed in cement mortar 1:1 with collars and tested complete all as specified & directed.
M&L for rendering 10 mm thick on any faces of brick work or concrete surfaces in cement mortar 1:4, surfaces finished even and smooth without using extra cement, complete all as specified and directed.
M&L for applying two coats of cement base paint over a coat of primer on newly plastered surface of walls including preparation of surface complete all as specified and as directed.
M&L for 150mm thick granular sub-base using 40mm graded stone aggregate Grade -1, deposited, spread and levelled ,watereed in two layers of 75mm thick each, watered and rolled with 8 to 12 tonne power road roller to a true surface complete all as specified and as directed..
M&L for 100 mm thick (compacted thickness) WBM laid with using stones aggregate (granite,trap or basalt ) of grading -2 (90 mm to 40 mm) size, spread ,watered rolled and consolidated to required gradient and camber with 8 to 12 tonne power road roller etc complete all as specified & directed.
M&L for 100 mm thick DLC M -15 design mix with min cement content 250kg/cum complete all as specified & directed.
M&L for reinforced concrete pipes, class NP-2, 150 mm bore, laid and jointed in cement mortar 1:1 with collars and tested complete all as specified & directed.
M&L for cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in concrete bed to drain pipe including packing under and haunching against the sides of pipe after they are laid and tested complete for pipe of 150mm bore complete all as specified & directed.
M&L for plain cement concrete 1:2:4 type B-2 (using 40 mm graded crushed stone aggregate) in surface channel of drain etc complete all as specified and directed.
M&L for Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, including forms, moulds, etc (inner girth only to be measured) complete all as specified and directed.
Add or deduct to Srl item No 150 here in before for each 25mm girth or part thereof over or under 30cm inner girth of drain or channel ditto
Removing excavated material ie. soils, exceeding 250m but not exceeding 500m and depositing where directed at a level not exceeding 1.5 Mtrs above starting point all as specified.
Excavation over areas not exceeding 1.5 M deep and getting out in soft/loose soil etc complete all as specified and as directed
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in Cement 1:4 complete all as specified and directed.
M&L for 100mm thick plain cement concrete 1:2:4 type B-1,(using 20mm graded crushed stone aggregate) in floor to bring uniform surfaces mix with WPC as per manufacturers instructions complete all as specified and directed. Note : WPC to be measured & paid separately under respective item of BOQ.
M & L for Construction of Septic Tank for 10 users including necessary earth work in excavation in any type of soil , plain cement concrete 1:2:4 type B-2 ( using 40 mm graded crushed stone aggregate ) as in foundation , brick work in cement mortar 1:4 , ,reinforced cement concrete M-25 ( design mix) as in slab cover including pre-cast man hole cover slab having 8 mm dia TMT bar reinforcemement @ 75 mm c/c & 6 mm thick mild steel plate embedded all around of cover slab , 15 mm thick plaster in cement sand mortar in 1:4 on wall, vent shaft, sludge chamber , form work to sides and soffits, 150 mm dia SGSW inlet & out let pipes up to 3 m from outer face of wall, CI vent pipe, sludge chamber, RCC baffle wall, returning filling & removal etc, complete all as shown on drawing No.TD-272 , Sheet No.1/1 & as specified.
M & L for Construction of Soakage well for 1.20 dia( internal dia ) & 3.0 m over all depth including necessary excavation in earth work in any type of soil , plain cement concrete 1:3:6 type C-2 ( using 40 mm graded crushed stone aggregate ) as in foundation , brick work in cement mortar 1:4 in walls & honey combed brick wall , reinforced cement concrete M-25 ( design mix) as in slab cover including pre-cast cover slab having 8 mm dia TMT bar reinforced , plain cement concrete band and dwarf wall, form work to sides and soffits of RCC slab & filling with brick bats loose filling complete complete all as specified and shown in drawing No.TD-576,Sheet No.1/1 & as specified. .
Taking down carefully existing unserviceable flame proof point wiring of any description & in any position with and including existing conduit fixed on surface with and including existing junction boxes in between the point wiring complete, including making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed.
Taking down carefully existing Flame proof light fittings & after repair refixing in its original position complete including making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed.
Taking down carefully existing Flame proof exhaust fan & making new hole refixing in its original position complete including making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed..
Material and labour for flame proof point wiring for one light point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade concealed steel conduit in walls/ceiling steel structure upto 15 mtr height with and including fixing of clamps, welding and other attachment requried to fix MS pipe with all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core FRLS, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly / fittings etc. complete all as specified and directed
Supply & fix in repair CMRI certificate LED flame proof 1x28 watt or next higher size tube light fitting as per IS : 2148 / 1981 & 2206 (Part-I )1984, temperature class T-4, & made of cast aluminum alloy LM-6 having inside & outside light grey powder coating shade No 631 as per IS: 5 & one No. internal earthing terminal and 02 Nos external earthings of screw of M6- size with 02 Nos plain washers heat resistant glass complete all as specified and directed. Make : Crompton Greaves cat part No EXTN1LT8-8 or equivalent make and model of Sudhir /Baliga.
Supply & fixing in repair flame proof FLP Well glass light 72 watt LED or next higher size fittings as per IS : 2148 / 1981 & 2206 (Part-I )1984, temperature class T-4, & made of cast aluminum alloy LM-6 having inside & outside light grey powder coating shade No 631 as per IS: 5 & one No. internal earthing terminal and 02 Nos external earthings of screw of M6- size with 02 Nos plain washers heat resistant glass complete all as specified and directed. Make : Sudhir Cat Part No FL/2C/1239 or equivalent make and model of Baliga/CG.
Taking down carefully existing unserviceable aluminium/copper point wiring of any description & in any position with and including existing wooden battens/conduits fixed on surface or concealed and all fittings including sunken/surface boxes & terminal boxes of any description, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings, lamp holders etc including sunken boxes / junction boxes and making good the disturbed surface of walls, floors, ceiling etc. to match with the existing surfaces complete all as specified and directed.
Supply and fix in repar flame proof exhaust fan FLP louvers 457 mm (18 inch) sweep, 230 Volts, AC, SP 1440 rpm and connecting to electric source complete all as directed and specified Make:Sudhir cat part no.EF-140/Baliga or any other equivallent make approved by the GE.
M&L for Point wiring for one light or one fan point controlled by one switch with using FR PVC insulated unsheathed /multi stranded copper conductor cable 1.5 sqmm including 1.5 Sqmm FR PVC insulated unsheathed copper conductor earth wire drawn through and including concealed PVC conduit medium grade of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bend, junction box and pressed steel sunken box 60 mm deep & 1.6 mm thick duly painted inside and anticorrosive out side for mounting switches, sockets, fan regulators etc with 3mm thick plastic laminated sheet cover of suitable size, connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar (1:4) and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etc (conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible), for light/fan/bell point etc complete all as specified and directed. (Note : Switch/socket etc shall be measured and paid separately)
All as per item No166 here-in -before but, point wiring for 5 pin switch socket outlet combination, 5/6 Amps on independent board. Complete all as specified and directed.
All as per Srl item No. 166 here-in -before above but, point wiring for 5 pin switch socket outlet 5/6 Amps on same board complete all as specified and directed.
All as per Srl item No. 166 here-in -before but point wiring for one six pin switch socket outlet combination, 15 Amps & 5 Amp (independent) with using 2.5 Sqmm (nominal area) stranded copper conductor and 2.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly Complete all as specified and directed.
Supplying & fixing for switch socket outlet combination, five pin, 5 Amps, flush type, 230 volts AC circuit complete all as specified and directed. Make: Anchor/Cona/Havells
Supplying & fixing socket outlet combination, five pin, 5 Amps, flush type, 230 volts AC circuit complete all as specified and directed. Make: Anchor/Cona/Havells
Supplying & fixing for switch socket outlet combination, multipurpose, three pin, 15 Amps & three pin 5 Amps controlled by one switch , flush type, 230 volts AC circuit complete all as specified and directed. Make: Anchor/Cona/Havells
Supplying & fixing for ceiling rose surface bakelite 63.5 x 20 mm, three terminals, complete all as specified and directed. Make: Anchor/Cona/Havells
Supplying & fixing for switch flush type, 5/6 Amps, single pole, one way, 230 volts AC circuit complete all as specified and directed. Make: Anchor/Cona/Havells
Supply and fix lamp holder, insulated body with back plate suitable for batten fitting complete all as directed. Make: Anchor/Cona/Havels
M&L for sub main wiring using two runs of single core PVC insulated, unsheathed multistranded copper conductor cable FRLS of size 4.0 Sqmm of voltage rating 1100 Volts grade, drawn in and including PVC conduit of dia not less than 20mm/ casing & caping on wall/roof surface with fixing accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4.0 Sqmm as earth continuity conductor and connecting to earth dolly including existng sub main wirting with conduit complete all as specified and directed by Eng-in-Charge. NOTE: Two runs of single core PVC cable + one run of earth continuity conductor + one run of PVC conduit shall be measured as one unit length.
M&L for sub main wiring using two runs of single core PVC insulated, unsheathed multistranded copper conductor cable FRLS of size 6.0 Sqmm of voltage rating 1100 Volts grade , drawn in and including PVC conduit of dia not less than 20mm/ casing & caping on wall/roof surface with fixing accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6.0 Sqmm as earth continuity conductor and connecting to earth dolly complete all as specified and directed by Eng-in-Charge. NOTE: Two runs of single core PVC cable + one run of earth continuity conductor + one run of PVC conduit shall be measured as one unit length.
M&L for sub main wiring using two runs of single core PVC insulated, unsheathed multistranded copper conductor cable FRLS of size 6.0 Sqmm of voltage rating 1100 Volts grade , drawn in and including PVC conduit of dia not less than 20mm/ casing & caping on wall/roof surface with fixing accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6.0 Sqmm as earth continuity conductor and connecting to earth dolly complete all as specified and directed by Eng-in-Charge. NOTE: Two runs of single core PVC cable + one run of earth continuity conductor + one run of PVC conduit shall be measured as one unit length.
M&L for sub main wiring using two runs of single core PVC insulated, unsheathed multistranded copper conductor cable FRLS of size 6.0 Sqmm of voltage rating 1100 Volts grade , drawn in and including PVC conduit of dia not less than 20mm/ casing & caping on wall/roof surface with fixing accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6.0 Sqmm as earth continuity conductor and connecting to earth dolly complete all as specified and directed by Eng-in-Charge. NOTE: Two runs of single core PVC cable + one run of earth continuity conductor + one run of PVC conduit shall be measured as one unit length.
S&F in repair LED street light 45 watt made up of pressure dia cast housing with toughned glass and individual LEDs with secondry optics and IP66 protection accessories including GI light grade tube 40 mm bore bracket of required shape & size, with and connecting the fitting to electric source with using copper conductor 23/0.0076 flexible twisted twin core cable , including all accessories and fixing arrangements for fixing the light fitting to walls / pillars complete all as specified and directed. Make :- Bajaj cat part No BRTFG 45W LED I or equivalent Philips/CG
Supply, fixing, connecting & testing of sheet metal enclosures double door, triple pole and neutral, 4 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating including disconnecting and taking down of old unserviceable distribution board with all fitting and fixture complete all as specified and directed. Make :-Legrand/Havels/L&T
All as per item no. 180 here-in- before but MCB distribution board , single phase, SPN DB 8 way complete, double door all as directed by Engineer-in-Charge.
S&F in repar for MCB three pole 63 Amps ('C' series) having current rating 10 KA including making electrical incoming/out going connectins with lugs/thimbles all as specifedand directed. . Make :- Legrand/Havels/L&T
S&F in repair for MCB SPN 40 Amps to 60 Amps ('C' Series) having current rating 10 KA complete all as specifed and as directed. Make :- Legrand/Havels/C&S
S&F in repair for MCB single pole 06 Amps to 32 Amps ('C' Series) having current rating 10 KA complete all as specifed and as directed.. Make :- Legrand/Havels/L&T
Supply, install, commissioning and testing of split type wall mounted Air conditioner of capacity 2 TR (6000 K Cal/hr) single phase, (Non CFC/HCHC) suitable for 230 Volt + 10% , 50 Hz, AC supply complete with cordless remote control unit , minimum 3 star rating complete comprising of following :- Make :- Carrier/Dikin/Hitechi/Blue star. (a) Indoor unit with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b) Out door unit comprising . Compressor with motor,. air cooled copper condenser with fan and motor .unit shall be installed out side the building/ on roof. (c) Refrigerant copper pipe for suction and discharge line with insulation , condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable. (d) Making good the disturbed surface to match the existing surface after plugging the hole etc. (e) PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on wall as per Manufacture's instruction with necessary grouting MS hold fast, bolts, washers duly painted and making good to disturbed surfaces suitable for installing outdoor unit of 2 TR AC complete all as specified and directed. (f) Electrical cable required to connect out door unit and indoor unit to voltage stablizer inclusive in above rate.
M&L for single pole and neutral enclosure with a two pin and earth plug and socket complete in metal clad board with one single pole MCB of rating 20 Amps, 240 Volts complete fixed on wall by provisioning of suitable size of MS strip, nuts, bolt and washer complete all as specified and as directed.
Supply and fixing voltage stabilizer for automatic opration ,single phase naturally air cooled indoor type & designed for input variation 170V to 250V with out put voltage stabilized at 230 V with accuracy of + 2.5 % Suitable for 2 TR AC. Make of stablizer V Guard Model No VND 500 or equivalent
M&L for Earthing complete for poles/DBs with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 15mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-1 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-1 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, including taking down of existing earthing complete all as directed. Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre. 2. Earth filling shall be done by vegetable soil. 3. Soil should be free from stone, boulders, aggregate, gravels etc.
Supply, laying , jointing & testing XLPE insulated,screened ,PVC bedded, galvanised steel strip or wire armoured, electirc power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 25 Sq mm 4.0 core including existing cable & removing form site complete all as specified and directed. Note : Excavation , earth work, sand cushioning for cable and cable protection cover shall be measured & paid under respective item.
Supply, laying , jointing & testing XLPE insulated,screened ,PVC bedded, galvanised steel strip or wire armoured, electirc power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 16 Sq mm 4.0 core including existing cable & removing form site complete all as specified and directed. Note : Excavation , earth work, sand cushioning for cable and cable protection cover shall be measured & paid under respective item.
S&F for Exhaust fan 300 mm sweep,230 volt, single phase iron body with louvers and including Cutting out holes in existing cement concrete / brick walls built in cement mortar and removing unserviceable / loose and supplying, fixing & grouting new purpose made arrangements all as directed including making good the disturbed surfaces to match with the existing surface & finishes Complete all as specified and directed.
Supply and fix in repair wall mounted fan 400 mm sweep having oscilating motion and speed control facility complete with accessories 230 V,single pole and connecting up including provision of cable from ceiling rose or connector to fan complete including making good the disturbed surfaces to match with the existing surface & finishes complete all as specified and directed.
Supply and fixing earth continuity conductor or main earthing lead 20 x 3.15 mm copper strip laid in pipe/ fixed on wall or any other position incuding jointing by tinned copper/ brass nuts bolts and washers in addition to brazing at every joint complete all as specified and directed.
Material and labour for earthing complete with Copper earth plate electrode 600mm X 600mm X 3.15 buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to Copper strip 20x3 mm main earthing lead by means of Copprer bolts, nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt alround earth plate, PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) for earth pit with pre -cast RCC cover 1:2:4 type B-1( using 20mm graded crushed stone aggregate), reinforcement with 8mm dia TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh,etc including taking down existing earthing complete all as specified and directed. Note:- The cost of earth lead upto 7.5 metre from the top of earth electrode is only deemed to be included under this item and additional earth lead, if any required shall be measured and paid for seprately under appropriate item of Sch A.
M&L for MS fabricating work with flat iron of any size, bolts, nuts cutting in to suitable size welding if any etc for fixing of flame proof light fitting of any other works as directed by Eng-in-Charge.
Supply and fix servo voltage stabilizers 3 phase, 415 Volts, 10 KVA, Air cooled, copper wound, indoor type for input voltage variation ranging from 170 -280 Volts (300-480 Volts) with outpur stabilized voltage at 415 Volts with accuracy of +/- 1.0 % and speed of voltage correction @ 80 Volts/ sec. The stabilizer shall have voltage cut -off for servo motor in case of under and over voltage at input and Digital VIF meters for input/out put voltage, current and frequecy. Controlls for Auto-manual switch/ lower-raise switch and stabilzer by pass switch. Make: Volina/Blue bird or equivallent.
Taking up/ down carefully existing unserviceable/ damaged/ broken CI/ DI pipe line of 100 mm dia with spigot and socket ends including taking down all fittings, burning out the existing lead joints and retrieving the lead all as specified and as directed: - Note : Excavation and earth work where required shall be measured and paid separately under relevant items of this Schedule.
Supply and fix ductile iron pipes, Class K-7, 100 mm dia with spigot and socketed ends centrifugally cast (spun) with factory applied cement mortar lining inside the pipes and outside with zinc coating with suitable push on joint (Rubber gasket D joint) confirming to IS 8329/2000 of following sizes; Note:-Excavation and earth work and DI specials where required shall be measured and paid separately under relevant item of this schedule.
Material and labour for Ductile iron fittings, heavy duty, such as bends, tapers, tees, collars, tail pieces, reducers, etc. laid and jointed with suitable push on joints complete any size upto 150 mm dia all as specified and as directed.
S& F for Sluice valve, cast iron body with stainless steel spindle, class-1 ISI marked,100mm bore, PN-1, both end flanged and drilled and fixed with bolts and nuts and washers including providing rubber insertion of suitable thickness complete of following sizes including taking out existing unserviceable sluice valves all as specified and as directed Make: Kirloskar/equivalent approved make
M&L for construction of brick masonary (230mm thick wall) valve pit of size 900mm x 900mm x 900mm inner dimension of necessary earth work excavation, 75 mm thick PCC 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, brick wall build in cement mortar 1:6, rendering 15 mm thick with cement mortar 1:6 externally up to 15 cm below ground level and cement mortar 1:4 internally and providing MS sheet cover 5.0 mm thick and angle iron frame of suitable size and two coats of synthetic enamel paint over one coat of red oxide primer on steel surface and welded with hings including necessary locking arrangement and complete all as specified and directed.
M & L for Cutting/Drilling of existing DI/CI iron pipes 100 mm bore and inserting of collars or other fittings including dewatering , excavation work and refilling with slugy soil complete all as specified and directed.
RAVINDRA SALES
M/s Kohli Builders
Lall Electronics
GM Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .