Loading…
Loading…
Tender Value
₹64.0 L
EMD Value
₹1.3 L
Closing Date
24 Jun 2026, 3:00 pm
Provision of Submersible Sewage Pump Motor set over Howrah division.
EL-HWH-25-21-3619
EL-HWH-25-21-3619
Open
180 Days
Howrah, West Bengal
₹0
₹1.3 L
1 Jun 2026
1 Jun 2026
10 Jun 2026
A-Provision of Submersible Sewage Pump Motor set over Howrah
Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos. single core HRFR / FRLS 1 grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in GI conduit of suitable dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos. single core HRFR / FRLS 2 grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for phase and neutral in GI conduit of suitable dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Wiring of Light / Fan / Call Bell / Glow Sign point by 4 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for three phases and 3 one neutral in GI conduit of suitable dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Wiring of Light / Fan / Call Bell / Glow Sign point by 4 nos. single core HRFR / FRLS 4 grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for three phases and one neutral in GI conduit of 25mm dia. along with 1 no. single core HRFR /FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Supply of Submersible Sewage Pump-Motor set of discharge capacity 92 Cubic metre per hour and discahrge head 9 Mtrs. (approx.) suitable for operation on 415V, 50 Hz, 3Ph / 240V, 50 5 Hz, 1 Ph supply system complete with one fully automatic starter control panel with all protection and float switch alongwith 10 Mtrs. long multicore copper flexible cable of suitable size for motor operation, 5 mtr. Lifting Iron Chain, GI clamps, steel wire rope with double pulley, PVC flexible pipe of suitable size and length including installation and commissioning. ( Make of pump-motor set - KSB / Texmo / CRI / Kirloskar / Crompton / Calama ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Supply of Submersible Sewage Pump-Motor set 3 HP of discharge capacity 600-100 LPM at discahrge Head Range 3 - 17 Mtrs. (approx.) suitable for operation on 1 Ph, 230V, 50 Hz, 6 supply system complete with one fully automatic starter control panel with all protection and float switch alongwith 10 Mtrs. long multicore copper flexible cable of suitable size for motor operation, 5 mtr. Lifting Iron Chain, GI clamps, steel wire rope with double pulley, PVC flexible pipe of suitable size and length including installation and commissioning. ( Make of pump-motor set - KSB / Texmo / CRI / Kirloskar / Crompton / Calama ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Trenching and laying of cable underground by pucca floor / concrete cutting with covering of cable through suitabe dia HDPE pipe including supply of HDPE pipe (PE-100 grade, PN-10 or higher) along with refilling the trench and make good of surface as its original condition ( Cable will be supplied by Railway ) Above/
Trenching and laying of cable under ground by soil cutting with covering of cable by sand and bricks / through suitable dia HDPE pipe including supply of HDPE pipe (PE-100 grade, PN- 10 or higher) without bricks alongwith refiling of trench by excavated soil and make good of surface as its original condition. ( Cable will be supplied by Railway ) Above/
Trenching, laying under road / track through 100 mm dia GI pipe ( medium gauge ) including supply of GI pipe and commi- ssioning of cable including back filling of trench with excavated soil after laying of cable ( Cable will be supplied by Railway ) Above/
Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable alongwith make good of floor surface as its original condition after laying of cable ( Cable will be supplied by Railway ) Above/
Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable through 80mm dia GI pipe including supply of GI pipe alongwith make good of floor surface as its original condition after laying of cable ( Cable will be supplied by Railway ) Above/
Drawing of cable on wall / structure with suitable size and shape GI clamps including supply of suitable size GI Clamp and GI nut- bolts and commissioning of cable ( Cable will be supplied by Railway ) Above/
Drawing of cable through one no. 2" dia, 3.0 Mtrs. long GI pipe ( Make - Tata / Jindal / Bansal ) for protection of cable on pole with proper GI clamps and GI nuts & bolts including supply of GI pipe ( Cable will be supplied by Railway ) Above/
Supply of GI ( minimum coating thickness 65 microns ) conical / octagonal ( minimum sheet thickness - 3mm ) Pole of overall length 5 M with single / double arm bracket, top cover, base plate including hinged door-inbuilt Junction box complete with copper bar, insulator, Hylam sheet for cable termination and fuse kit-kat / MCB ( Make - Utkarsh / B.P. Projects / Crompton / Bajaj / Surya ) Above/
RCC foundation, erection and commissioning of above GI pole with construction of cement concrete muffing ( Cement : Stone : Sand = 1 : 2 : 4 ) with foundation accessories including earthing of pole with 1 no. of 50 mm dia, 3 M long GI pipe ( Make - TATA / Jindal / Bansal ) with necessary earth connection from pipe to pole by GI Strip / GI wire Above/
Wiring of light point by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper 16 conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral through pole from inbuilt pole Junction Box's porcelain fuse kit-kat / MCB to light fitting along with 1 no. single core HRFR / FRLS grade, PVC insulated copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Dismantling / Cutting of existing pole and make good of surface including transportation from site to stores Above/
Designing of mounting layout, supply, installation, connection and commissioning of Street light 90 Watt LED (Type of LED - Surface Mounting Device ) luminaire, pressure die cast housing with Ingress Protection - IP66 or higher ( LED chip make - Nichia, Osram, Seoul, Philips, 18 Lumileds, Everlight, Avago, Cree, Lednium, APT Electronics & BridgeLux ), complete with all accessories, LED luminaire system Efficacy minimum - 130 Lumens per Watt @ 350mA drive current, Impact resistance IK-05 or higher, Colour Temperature - 5700K, Driver Surge Protection minimum 4KV, Life span of LED chip Greater than 50000 burning hours, The Luminaire & Driver both should be of same make / brand and individually BIS approved with 60 months warranty including fixing with suitable dia heavy gauge GI bend pipe with GI clamps made of GI flat of size 40mm x 6mm and GI nut-bolts on structure / wall. (Make : Philips (Signify) /Havells / Bajaj / Panasonic/ Crompton / Jaquar /Lighting Technologies/ Halonix ) Above/
Designing of mounting layout, supply, installation, connection and commissioning of Street light 90 Watt LED (Type of LED - Surface Mounting Device ) luminaire, pressure die cast housing with Ingress Protection - IP66 or higher ( LED chip make - Nichia, Osram, Seoul, Philips, Lumileds, Everlight, Avago, Cree, Lednium, APT Electronics & BridgeLux ), complete with all accessories, LED luminaire system Efficacy minimum - 130 Lumens per Watt @ 350mA drive current, 19 Impact resistance IK-05 or higher, Colour Temperature - 5700K, Driver Surge Protection minimum 4KV, Life span of LED chip Greater than 50000 burning hours, The Luminaire & Driver both should be o f same make / brand and individually BIS approved with 60 months warranty including fixing of outdoor LED Flood light / Street Light fitting on High Mast Tower/Pole/Structure with suitable arrangement. (Make : Philips (Signify) /Havells / Bajaj / Panasonic/ Crompton / Jaquar /Lighting Technologies/ Halonix ) Above/
Designing of mounting layout, supply, installation, connection and commissioning of Flood light 80 Watt LED (Type of LED - Surface Mounting Device ) luminaire, pressure die cast aluminium housing with Ingress Protection - IP66 or higher ( LED chip make - Nichia, Osram, Seoul, 20 Philips, Lumileds, Everlight, Avago, Cree, Lednium, APT Electronics & BridgeLux ), complete with all accessories, LED luminaire system Efficacy minimum - 100 Lumens per Watt @ 350mA drive current, Impact resistance IK-05 or higher, Colour Temperature - 5700K, Driver Surge Protection minimum 4KV, Life span of LED chip Greater than 50000 burning hours, The Luminaire & Driver both should be of same make / brand and individually BIS approved with 60 months warranty including fixing of outdoor LED Flood light / Street Light fitting on High Mast Tower/Pole/Structure with suitable arrangement. (Make : Philips (Signify) /Havells / Bajaj / Panasonic/ Crompton / Jaquar /Lighting Technologies/ Halonix ) Above/
Supply of SPN DB ( Metal Enclosure with Metal Door ), 8 way, 50Hz, complete with 4 nos. SP MCB of current rating from 6A to 32A, 10kA, 240V, 50Hz as per requirement of load and 1 no. DP RCBO of current rating 40A, 300mA, 10kA, 230V, 50Hz ( Make of MCB, RCBO and Metal Distribution Board - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S / Havells ) Above/
Fixing, connection and commissioning of above SPN MCB DB with suitable arrangement including all incoming and outgoing cable connection with suitable cable termination arrangement. Above/
Supply of TPN MCB DB ( Heavy duty, Outdoor type, UV ray protected, self fire- extinguishing and resistant to abnormal heat and fire up to 650 degree C GWT, shock resistance 23 IK08 or above and IP65 degree of protection grade transparent DB box, similar to ABB Mistral65 - 20 Modules or equivalent ), 3Ph, 50Hz, 415V, 4 way per phase, 415V, 50Hz, complete with total 12 nos. SP MCB of current rating from 6A to 32A, 10 kA, 240 Volt, 50Hz per phase as per requirement of load and one no. FP RCBO 63A, 300mA, 10 kA, 415V, 50Hz, Suitable for AC + Pulsating DC (Type A) + Harmonics ( Make of MCB & RCBO - LK (L&T) / Siemens / ABB / Hager Legrand / Schneider ) ( Make of TPN DB - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / Spelsberg / Hensel / Eaton ) Above/
Fixing, connection, testing and commissioning of above TPN MCB DB including all incoming and outgoing cables glanding, cable connection with cable termination and suitable wall hanging arrangement as per site condition with all associated accessories. Above/
Designing of mounting layout, supply, installation, connection and commissioning of 20-22W LED batten (Type of LED - Surface Mounting Device ) tube with industrial grade constant current Driver ( Efficiency - Greater than 85% ) with short circuit protection, extruded aluminium housing and milky polycarbonate diffuser ( LED chip make - Nichia, Osram, Seoul, Philips, Lumileds, 25 Everlight, Avago, Cree, Lednium, APT Electronics & BridgeLux ), LED luminaire system efficacy - Greater than 120 Lumens per Watt @ 350mA drive current, Colour Temperature - 6500K (Cool white), CRI>80, SDCM<5, Driver Operating Voltage - 140-270 Volt AC, Surge Protection minimum 4KV, THD<10%, Driver HV Cut off @ 325V/440V (P2P) protection for 8 hrs., Life span of LED chip Greater than 50000 burning hours, The Luminaire & Driver both should be of same make / brand and indivi- dually BIS approved with 60 months warranty including fixing with GI clamps made of GI flat of suitable size & GI nut-bolts. (Make : Philips (Signify) /Havells / Bajaj / Panasonic/ Crompton / Jaquar /Lighting Technologies/ Halonix ) Above/
Supply of Wall Bracket Fan of size 400mm sweep suitable for operation on 1Ph, 220- 26 240V, 50Hz supply system including installation, connection and commissioning of Wall Bracket fan with GI clamps made of GI flat of suitable size and GI nut-bolts on wall / structure. ( Make : Havells / Usha / Orient / Halonix / Atomberg / Crompton / Bajaj ) Above/
Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos. single core HRFR / FRLS 27 grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Wiring of 6A / 3 pin Plug board consisting with one plug socket and one 6A switch by 28 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Wiring of Submain by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Extra cost for conceal wiring in respect to PVC conduit / casing for light, fan, plug, power plug, multi-plug point etc. including make good of wall surface as its original condition Above/
Extra cost for conceal wiring for main / submain with respect to PVC conduit / casing including make good of wall surface as its original condition Above/
Supply of Outdoor pillar box type control panel board made of 14 SWG ( 2mm ) MS sheet duly powder coated comprising with the following : a) MCCB with Thermal - Magnetic Release 32 of breaking capacity 36 kA at 415V AC, 50Hz ( Ics = 100% Icu ) suitable for release range 25-32A, 4 Pole - 1 no. b) Astronomical Timer Switch - 2 nos. c) Power Contactor, 3 Pole, 18A, 415V, 50 Hz - 2 nos. d) LED indication lamp for 3-Phases for incoming feeders and "ON, OFF, TRIP " indication for all incoming and outgoing feeders - 10 nos. complete with fabrication, internal wiring by single core copper conductor cable and all other accessories for above panel ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) Above/
Fixing, connection, testing and commissioning of above panel including all incoming and outgoing cables glanding, cable socketing and connection and construction of concrete foundation or suitable wall hanging arrangement as per site condition with all associated accessories Above/
Supply of LT cubicle type indoor wall / floor mounted Distribution Panel Board made 34 of 14 SWG ( 2mm ) MS sheet duly powder coated comprising with the following : a) MCCB with Microprocessor Release of breaking capacity 36kA at 415V, AC 50Hz ( Ics = 100% Icu ) with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt ground fault protection, 4) Inbuilt Instantaneous protection, 5) Adjustable neutral overload protection, 6) Provision of Thermal Memory, 7) Microprocessor protection-based MCCB must have facility of individual 'LSIG' fault indication suitable for Release Range ( 63-160 ) Amp, 4 Pole - 1 no. b) Power Contactor, 4 Pole, 100A, 415V, 50Hz - 2 nos. c) Astronomical Timer Switch, 2 module - 2 nos. d) Tinned Copper Busbar ( 4 Bar ) each of capacity 200 Amps., 415V, 50 Hz - 1 set e) Static Multifunction panel mounting LED Energy Meter suitable for operation on 3Ph, 415V, 50Hz supply, Cl 1 with provision of RS485 having display parameters - V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On hours, Phase angle, Interrupts, THD, Events ( High-Low ), Neutral Current, K Factor - 1 no. f) CT of suitable ratio for MFM - 3 nos. g) LED indication lamp for Phases and "ON & OFF" indication for operating status of breakers - 12 nos. h) Petty Store for cable gland, socket, fuse etc. - 1 job complete with all other accessories, internal wiring by single core FRLS grade copper conductor cable of suitable size and 1100V grade along with fabrication work, cable glanding, socketing etc. ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) ( Make for Energy Meter - ABB / Schneider / Secure / Legrand / LK (L&T) / Genus / Conzerv / Elmeasure / Stelmec / HPL / Socomec / Anchor / C&S ) Above/
Fixing, connection, testing and commissioning of above panel including all incoming and outgoing cables glanding, cable socketing and connection and construction of concrete foundation or suitable wall hanging arrangement as per site condition with all associated accessories. Above/
Supply of MCCB with Thermal - Magnetic Release of breaking capacity 36 kA at 415V AC, 50Hz of capacity 25-32A / 32-40A / 40-50A, 4 Pole complete with metal enclosure with spreader terminals including fixing, connection, testing and commissioning. ( Make - L&T /Siemens / ABB / Hager / Legrand / Schneider / C&S ) Above/
Supply of Sheet Moulded Compound ( SMC ) JB box, fire retardant of size 450 x 375 x 37 200 mm ( IP-55 ) / equivalent size heavy duty, outdoor type, UV ray protected, self fire- extinguishing, shock resistance IK08 or above and IP65 degree of protection grade transparent polycarbonate DB box including fitment with suitable size and shape Mild Steel ( MS ) bracket by replacing existing damage box and accessories with testing and commissioning. ( Make : Hensel / Sintex / OBO Bettermann / RMC / Grasp / ABB / Legrand / Spelsberg / EPP Composites ) Above/
Supply of Thermoplastic Polycarbonate Busbar Chamber of dimen- sion 450mm x 300mm x 210mm consisting with 4 nos. tinned copper busbar of each bar of capacity 200 Amp, 6 way, suitable for 415V, 50Hz supply system and 6 nos. Cable glands with Ingress protection : IP65 or 38 higher as per IEC-60529 ( weather proof), rust, dust, moisture and shock proof, anti corrosive, halogen free acid resistant, light weight, impact resistant IK 08/09 as per IEC- 60068-2-72, fire returdant, insulated, UV stabilised as per EN ISO 4892, should withstand glow wire test at 960 degree C as per IS 11000-2-1,IEC-60695-2-10 and fire rated UL94V-0 complete with hinged door with locking arrangement including fixing, connection and commissioning of above Junction Box on pole/structure with mounting clamp. ( Make : Hensel / Sintex / OBO Bettermann / RMC / Grasp / ABB / Legrand / Spelsberg / EPP Composites ) Above/
Supply of MCB DP, 40A, 1Ph, 240V, 50 Hz, 10kA with polycar- bonate distribution box enclosure (IP-65) with polycarbonate trans- parent openable window including fixing, connection, testing and commissioning. ( Make of MCB - L&T/Siemens/ABB/Hager/Legrand/Schneider and Enclosure Board - Grasp/OBO Bettermann/ABB/Schneider ) Above/
Earthing with 2 nos.of 50 mm diametre, 3.0 metres long heavy gauge GI pipe ( Make - Tata / Jindal / Bansal ) including construction of earth pit and necessary earth connection from pit by suitable Galvanized Iron ( GI ) strip. ( For details not covered in this specifications, Indian Standard Code of Practice for earthing IS : 3043 - 1987, Reaffirmed - 1996 should be followed ) Above/
Goods & Services Tax ( at present @ 18% )
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
AnnexureVIB_1.pdf
ATTACHMENT
TenderFormandAnnexuresnew.pdf ANNEXURE
ATTACHMENT
Annexure-VA.pdf
ATTACHMENT
TenderBooklet.pdf
ATTACHMENT
GCC_April-2022.pdf
ATTACHMENT
HTLTstandardspecification.pdf
ATTACHMENT
Advancecorrectionslips.pdf
ATTACHMENT
3619Clause.pdf
ATTACHMENT
TenderFormandAnnexuresnew.pdf
ATTACHMENT
Download all tender documents and submit your bid