| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹19.3 L+₹14,719 (0.77%)Rejected-Finance | L2 | Rejected-Finance NOT L1 | |
| 3 | L3₹19.5 L+₹33,964 (1.78%)Rejected-Finance | L3 | Rejected-Finance NOT L1 | |
| 4 | L4₹20.0 L+₹88,939 (4.65%)Rejected-Finance 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L4 | Rejected-Finance NOT L1 | |
| 5 | L5₹21.0 L+₹1.9 L (9.73%)Rejected-Finance FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L5 | Rejected-Finance NOT L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
8 Oct 2020, 6:00 pmClosed
CWE (ARMY) SECUNDERABAD
CWE (ARMY) MUDFORT COMPLEX, SECUNDERABAD- 500003
REPAIR AND MAINTENANCE TO TRANSFORMER OF VARIOUS CAPACITY INCLUDING MAINTENANACE OF HT DISTRIBUTION SYSTEM, REPAIR /REPLACEMENT OF UNSERVICEABLE HT CABLES AND CONNECTED ALLIED WORKS AT CDM SECUNDERABAD UNDER GE(U) SECUNDERABAD
2020_MES_376205_1
CWE(S)/UTILITY/TOKEN-17 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Secunderabad
As per NIT
6 documents required · 6 mandatory
₹500
GE (Utility) Secunderabad
₹50,000
Yes
31 Dec 2020
10 Sept 2020
12 Oct 2020
10 Sept 2020
8 Oct 2020
25 Sept 2020
Amount
Supply and stringing ACSR conductor of any size from LT/HT over head line as directed including fixing to insulators with proper size of binding wire complete.Including dismantling and taking out warn out ACSR conductor from overhead electric line comlete all as specified and directed
M&L in repairs for cradles, hexagonal / rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia complete all as specified and directed
Dismantling old PCC Pole and Supplying, Errecting and fixing Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 metres long) and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" wide, complete all as specified and directed.
M & L for Switch Airbreak Triple pole, mechanically operated , mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps suitable for 11000 Volts Grade complete all as specified and directed
Supply and fix lightning arrestor HT 11 KV 10 KA station class including taking down old unsv Lighting Arrestor complete all as specified and directed.
S & F for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer and including taking down old unsv complete all as specified and directed
Material and labour XLPE insulated (Earthed) , screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts grade,3 core,cross sectional area 95 sq.mm including inspection and testing.including taking down old U/S HT cable complete all as specified and directed
Material and labour XLPE insulated (Earthed) , screened PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) with aluminium conductor, 11000 volts grade,3 core,cross sectional area 120 sq.mm including inspection and testing.including taking down old U/S HT cable complete all as specified and directed
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for Straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for Straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed. Make : 3M/M SEAL/ DENSON
Disconnecting and taking out warn out jumpers of HT over head line / sub station any size any length after removing binding wire/sub station connector of AB switch/DO fuse unit, replacement the any size ACSR conductor jumpers including PVC sleeve in colour coding R/Y/B of same size and length including new biding wire/sub station connectors suitable for AB switch/DO fuse unit, with providing conducting jellycomplete all as specified and directed
Dismantling and taking out warn out/ U/S existing pin insulator from existing HT O/H Line , supply and fixing of new pin type porcelain , vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height and 150 mm dia suitable for working pressure 11000 Volts grade complete all as specified and directed.
Dismantling and taking out warn out/ U/S existing disc insulator , supply and fix of new disc type insulator, porcelain, vitreous, white brown or green, 145mm high, and 225mm dia ball and socket type single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts grade complete all as specified and directed.
Dismantling and taking out warn out/ U/S existing post type insulator S &F post type insulator 12 KV suitable for air break switch / drop out fuse with necessary nuts, bolts, washers complete all as specified and directed
Dismantling 11 KV air break gang operated switch triple pole, with Drop out fuse unit any type vertical/ horizantal mounted including operating mechanism for repair/replacement of broken/worn-out components and insulator etc and refixed same after repairs, overhauling all moving components with providing petrolium jelly in fixed contact and making serviceable complete all as specified. Note:- Warn out components shall be measured and paid separately
Supply only following components of air break gang operated switch:-
(a) Male contact or fixed contact heavy duty and high conductive metal assambly brass/Gun metal complete capacity 200 Amp 11 KV Make Rastriya/Jaipuria
(b) Female contact or Moving contact blade heavy duty and high conductive metal assambly brass/Gun metal complete capacity 200Amp 11 KV Make Rastriya/Jaipuria
(c) Tinned copper flexible jumper 200A/400A Make Rastriya/Jaipuria
(d) MS jumper carrier Make Rastriya/Jaipuria
(e) Back Connector plate Make Rastriya/Jaipuria
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard / dense soil complete all as specefied and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose/hard/dense soil complete all as specefied and directed
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specefied and directed
M & L for sand cushioning to underground cable including punning down of sand in layer complete all as specified and directed. Note :- Thickness of sand cushion after punning down i.e 18 cm shall be measured for payment
M&L for PCC 1:3:6 type C2 (using 40mm graded aggregates) as in foundation, filling and mass concrete complete all as specefied and directed
M&L for PCC 1:3:6 type C-1 (using 20mm graded stone aggregates) as in coping / pedestal of poles including necessary formwork complete all as specified and directed
Supply and lay un-reinforced precast concrete cable cover , class , HV , Type I flat size 300 x 180 x 40 mm laid dry in trenches over under ground cables complete all as specefied and directed
Supply anf fixing in replacement of HT 11 KV bushes porcelain, vitreous with brass spindle, threaded with washers, nuts, lock nut and rubber seal suitable for 100 KVA transformer of any make / type / size all as specified and directed
All as per Item No 27.00 above but suitable for transformer of capacity 200 KVA complete all as specified and directed
All as per Item No 27.00 above but suitable for transformer of capacity 400 KVA complete all as specified and directed
Supply and fixing in replacement of LT bushes 415 volts, porcelain, vitreous with brass spindle, threaded with washers, nuts, lock nut and rubber seal suitable for 100 KVA transformer of any make / type / size all as specified and directed by
All as per Item No.30.00 here in before but suitable for transformer of capacity 200 KVA complete all as specified and directed
All as per Item No.30.00 here in before but suitable for transformer of capacity 400 KVA complete all as specified and directed
M & L for top gasket sheet made out of cork sheet with suitable GI bolts, nuts, washers for transformer top cover complete for transformer of capacity 100 KVA all as specified and directed
All as per Item No.33.00 here in before but suitable for transformer of capacity 200 KVA complete all as specified and directed
All as per Item No.33.00 here in before but suitable for transformer of capacity 400 KVA complete all as specified and directed
Supply only new transformer oil for top up, of low viscosity of approved make as per IS 355 of 1992 and di-electric strength 40KV all as specified and directed
M & L for filteration and dehydration of existing transformer oil including heating continuously and taking result of transformer oil before/after filteration and dehydration complete all as specified and directed
Supply only in replacement breather assembly CI body of standard size filled with silica gel for transformers upto 400 KVA complete all as specified and directed
Supply only In replacement of temperature gauge circular type of standard size and suitable for indoor/out door type transformer upto 400 KVA capacity complete all as specified and directed
M & L for replacement of tapping switch/gear changer mechanism for varying LT voltage in steps for transformer capacity 100 to 200 KVA complete all as specified and directed
All as per Item No.40.00 here in before but suitable for transformer of capacity 200 to 400 KVA complete all as specified and directed
Find out Fault in existing U/G HT cables laid below 1 Mtr depth of earth surface in any location of GE (U) secbad Area by the expert engineers team of state electricity board using and hiring of HT fault locator complete Note : HT Straight through Joint kit will be paid and measured seperatly
M & L for cleaning / painting the HT poles of OH lines and HT four pole/ two pole structures complete with cross arms any height and any description throughly with necessary cleaning agent including scapping up of old corroded paint dirt / rust carefully and applying one coat of aluminium red oxide primer and two coats of aluminium paint including marking and colour washing of pole etc complete all as specified and directed
Restringing of HT over head line single ACSR conductor comprising of any size of conductor aluminium/copper/GI after opening binding wire from insulators and replace binding wire and achieved permissible sag limit of over head line conductor complete all as directed and specified. Note- Rate quoted by the contractor shall be deemed to include for cutting/trimming of tree branches wherever touching the over headline around one metre clear of over head line and removing trimmed branches as directed.
Supply only enamelled copper winding wire/strips of superior quality and approved make of suitable gauge and number of turns for rewinding HT/LT damaged coils of transformers of different make, type and capacity alongwith allied materials such as cork sheet, fibre glass insulation / paper insulation / cotton, ampire tape and wooden blocks, bolts, nuts and washers (Brass) soldering and other packing materials etc., all as specified and directed .Make : Atlas / BIC
Re-conditioning of LT coil of transformer copper wound made out of super enmalled insulated copper strips as per existing gauge and number of turns of any make, type and capacity including insulating, binding varnishing and backing as required complete all as specified and directed.
Dismantling the transformer step down 11KV / 433 Volts capacity ranging from 100 KVA to 400 KVA, pole mounted/platform mounted, disconnecting all electric connections taking down carefully and removing the top cover for inspection and then draining of complete transformer oil and taking out the core alongwith HT/LT coils, rewinding, heating, varnishing, testing and housing accessories in transformer body and connecting up, refilling the dehydrated/ filtered transformer oil / top up new transformer oil and connecting with existing electrical system HT/LT and commissioning complete on load all as specified and directed .( In case the repairs which are not possible at site then the transformer has to be taken to the work shop for repairs and Reassembling & testing complete and provide testing report, transporting back & up load the same at site by using crain safely. Reconnecting & commissioning al as specified.) Notes :- 1. Winding wires /strips of copper or aluminium shall be measured and paid separately. 2. Spares like Breather assembly, Temp Gauge, LT Bushing, HT Bushing, Top up of new Transformer oil shall be measured and paid seperately under respective items. 3. Dehydration and filteration of existing oil shall be measured and paid separately. 4. Transportation of transformer if required ( to & fro) is deemed to be included. 5. Labour component for fixing of supply only items is deemed to be included in the rate quoted.
Ovening/heating of transformer of core rating 100 kva to 500 kva of with HV & LV coil / winding at steady temperature for up 72 hrs or above to get permissible insulation value complete all as specified
Supply and fill Silica Gel in transformer of any capacity/ any make including taking down old silicagel complete all as specified
Supply & lay 80mm dia bore GI tubing light grade in protection of cable at road crossing /hard standing/pole protection fixed with clamps as per site requirement etc including taking down U/S one complete all as specified and directed
Supply & lay 100mm dia bore GI tubing light grade in protection of cable at road crossing /hard standing/pole protection fixed with clamps as per site requirement etc including taking down U/S one complete all as specified and directed.
M&L for boring horizantally holes under the road below 1.5 mtrs from the road /hard surface by trenches techonology using utra sound techanic and including necessary machine with out damaging the existing road and getting out any type of soil and disposal of soil to a distance not exceding 50 mtrs from the site of work including supply and lay HDPE pipe up to 150 mm dia suitable for MPA work pressure complete all as specified and directed.
Supply and spread and leveling Graded coarse Aggregate in loose filling over the sand of guage 20 mm nominal size in the installation yard all as specified and as directed
M&L for preparation of old painted surfaces for outdoor/indoor LT panels with applying two coat of synthetic enamelled grey paint after removing all dust & rust and paint shall confirm to IS 2032 complete all as specified .
M&L for Spray painting of transformer of capacity up to 400KVA, 11/.433 KV pole mounted / plinth mounted at site and applying two coats synthetic enamelled after preparation of transformer surface complete all as specified and directed. Note:-Unit Rate quoted by the contractor shall be deemed to include fo marking of transformer capacity with stencil letter with black or white paint and Font and Size of letter
M Laxmana Rao and Sons
Sri Surya Enterprises
STANDARD AGENCIES
L and S ENTERPRISES
Venkat Sai Enterprises
SUN LIGHT HOUSE
RR DURAFABS PVT LTD
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .