PWD Compound, Kenduadihi, Near Bhairabsthan,Bankura-722102
Special Renovation of E.I. work ,Compound Lighting, UPS system in Govt. model school, Onda Block, Bankura
2022_WBPWD_394270_1
WBPWDTE/EE/BED/NIQ_35/Q of 2022-23-2nd Call Tender
Open Tender
ELECTRICAL WORKS ORG
Item Wise
45 days
BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹39,569
EE/BED/PWDTE
22 Nov 2022
8 Aug 2022
26 Aug 2022
8 Aug 2022
24 Aug 2022
10 Aug 2022
10 Aug 2022
Amount
Sub Head-AC S & Installation 2.0 Ton capacity Split type A.C machine Normal cooling capacity Kcal/hr: 4500 Maximum power consumption :2400watts Minimum cooling capacity (Kcal/hr) : 4500 Minimum Room discharge Air flow(Cum/hr): 700 & Energy efficient type : Five star rating with approved make as per IS 1391, Part-I , with all connection With remote ( make-Hitachi /Daikin/Mitshubishi /PWD Appovd. as per direction of EIC
Extra Cu pipe two nos 0.5" and 0.25" for suction & discharge incl. Suitable suze cable and insulation foam as per dir of EIC
Sub Head-INTERNAL WORK S/F of SPD 3P+N max current 40KA ( Cat No AUSPO23PN40) on DB enclosure Make L&T/Legrand/Havells/PWD Approved.
S/D of 6x10 Sqmm single core stranded cu wire through 25 mm dia polythene pipe concealed in wall as per GS
Distribution wiring in 1.1 KV grade 3x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire partly in 20mm size PVC rigidconduit 'FR' (Precision make) [for ceiling portion only] and in19mm bore, 3mm thick polythene pipe [for horizontal &vertical run embedded in wall] to light / Fan / Call bell point as per GS withfollowing average run. 9 mtr[E-15/5(d)]
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point as per GS. On Board [4 (a)(i)/E-10]
Cutting Channel of required size on masonry wall of following diameter as per GS.[E-3/6(a)] 19 mm dia 3 mm thick
Supplying and Drawing 1.1 KV single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS. [E-9/1(b)] 3 x (1.5 sqmm)
2x(2.5 sqmm)+1x(1.5 sqmm) [E-9/1(s)]
2x(4 sqmm)+1x (2.5 sqmm) [E-9/1(v)]
2x (6 sqmm) + 1x (4 sqmm) [E-9/1(y)]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes as per GS 175 x 100 x 65
Supplying and fixing 2+14 Way[ Make - Schneider/Havells Legrand/Crabtree]double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. 40A DP Isolator as incomer and 14 Nos (6-32A)SPMCB as outgoing
Supplying and fixing 6 Way double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make -Havells Legrand/Schneider/L&T ) 63A FP MCB Isolator as incomer and 18 nos (6-32A) SPMCB as outgoing
Supply & Fixing 240 V,2 nos 6A, plug socket with separate 6 A Piano key type switch on sheet metal switch board embedded in wall as per GS
Supply & Fixing 240 V, 4 nos. 6A, plug socket with separate 4nos. 6 A Piano key type switch, indicator & 16A switch type SP MCB as per GS
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch on sheet metal switch board embedded in wall as per GS
Fixing only florescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports etc as per G.S [ 15 / C-2 ]
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit as per GS [16/C-2 ]
Supply of LED tube light 18W Make Philips/Crompton/Havelles
Internal wiring with wire for fixing LED tube in place of Fl. Light fittingsas per EIC
Supply of LED 4 Ft. 20 Watt single/twin florescent light fitting for indoor application,complete with all accessories & 18 Watt LED Master Tubehaving following Model / Cat No.( Make -Philips/havelles/Crompton/PWD approved TMC 501 P1xT-LED 22wP3241 with 18 master tube.
TMC 501 P2xT-LED 22wP3242 with 2 nos 18 master tube.
S&F of 9W LED Lamp(Philips/Havelles/Crompton) on angular holder on wall as per dir of EIC
S/F of surface mounted LED square light fittings as per dir of EIC(Make-Philips/Havelles/Crompton)
Supply & Fixing Socket type fan regulator (Step type)(Brand approved by EIC) on existing sheet metal switch board as per GS
Supply & Fixing of Wall Bracket Fan fans complete with all accessories having the following Model / Cat No. ( Make O-rient/Crompton Greaves/Usha ) 450 mm (18") Make Orient( Model:Tornado wall II
Supply & Fixing of 12'' Exhaust fans complete with all accessories and coule having the following Model / Cat No. ( Make -EPC/Orient/Usha/PWD Approved )
S & F 240V 25A OLP - 30 Electrronic motor starter in 175mm X 100mm X 65 mm depth 16 SWG MS Box coneled in wall with bakelite top cover incl. Necy. Conncetion as per direction of EIC for AC Machines
S&F sheet metal 2 module Anodised box in conceal in wall incl S & Fbase & top incl S & F 25A capacity 5 pin base & Top North Make and earthing attachment as per EIC
S/F of gong ball 12'' as per direction of EIC
Excavation of Morum Soil for installation of Earth Electrode and filling & ramming as per GS
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS
Connecting the equipments to earth busbar including S & F Solid 4SWG GI (Hot Dip) wire of size as below as per GS
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS [4(a)/G-2]
Sub Head-EXTERNAL WORK S & Erection of mini pole of size 6 ft. long approx 80 mm. dia seamless pipe Class - B , on the roof of the Bldg. By S& providing M.S. plate incl. Rose type arrangement near base plate for smooth cable entry position and making C.C. muffing of size 450 x 450 x 600 mm. hight with cement mortor mixture ( 6 : 3 : 1 ) incl. neet cement finish before cheaping properly the existing roof incl. S& providing earth bold after drilling holl etc. as per direction of E.I.C.
S&F cylindrical type pole head suitable for 80 mm. dia seamless pipe and should be waterproof & fabricated from steel member steel pipe. The cylindrical portion of the pole head which sleeve over the pole shall have a length of 40 cm. ( 18" ) approx. Incl. making 225 mm. dia ( 9" ) cable terminal box. The above terminal box welded with sleeve incl. S&F 1 No. 4 way bakelite terminal AC/DC make & 1 No. 15 Amp. fuse base & bridge inside the cylindrical portion of the header assembly as per direction of E.I.C.
S&F 50 mm. dia 1.5 mtr. long detachable type Single arm bracket, suitable for pole head. The arm bracket shall be properly welded with 15 mm. thick stifner plate of pole sleeve for strengthening incl. properly fixing arrangement with the pole by bolts, nuts and washer as per direction of EIC
Inter connection of LED light fittings by 2 x 1.5 Sq. mm. PVC insulated copper wire from pole loop box with best quality PVC pipes as per direction of EIC
Supply & Fixing of 240V, 128 Watt Fittings Crompton/Philips/Havelles [ Cat No.BRP322 LED 128 CW HE MR FG S3 XT]
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint Upto 9.0 mtr. long pole 1st coat of aluminium paint over 1 coat of RO priming and 2nd coat of aluminium paint over 1st coat as per GS
S& F of Post Top Lantern fitting with spherical cover & Street light fitting complete with all accessories. Make-crompton/Phillips/Havelles/PWD Approved (Cat no- LPTO-40-CDL)
S& F sheet metal Loop box of size 8''x6"x2 1/2" made of 14 SWG CRC Sheet with Hing type door and door locking arrangement incl S&F 250 V 3 way AC/DC make bakelite terminal in conceal in in wall after cutting the wall & mending good damage as per dir of EIC
S&F of 100A busbar chamber with 4 nos Al bars of approved make as per direction of EIC
Timer Panel:Supplying and fixing (2+12)way Legrand/L&T/PWD Approved DB enclosure for housing the following A) One no.single dial digital timer (Legrand/L&T/PWD Approved) B)One no. FP pole, conctractor,(L&T/ABB/PWD Approved) C) One no. FP 63A MCB D) One no. auto/manual Toggel Switch and other required material The complete arrangement must be wiring by PVC insulated Cu wire as per GS
Supply & Fixing of ceiling fans complete with all accessories having the following Model / Cat No. ( Make -Crompton Greaves/Usha/Orient ) 1200 mm Sweep (Aura Prime Anti Dust )
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make KEI/Polycab/Glostar / RR Kabel] 2 Core 10 Sq. mm [ NS ]
4 Core 10 Sq. mm [ NS ]
Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes. 2.5 to 35 Sq. mm [ 5(i)/ F- 3 ]
Laying of cable upto 35 sqmm in underground trench as per GS
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. 2 Core 10 Sq. mm [7(c)/F4 & 8(b) /F5]
4Core 10 Sq. mm [7(c)/F4 & 8(b) /F5]
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS 40mm dia [11(c)/F-6]
Sub Head-UPS Supply,Installation, Testing & Commising of 3.7KVA off line Inverter with trolley for the same inverter with 48Volt ( make-Exide/Amara Raja-Quanta/PWD approved) (Model JLSW) Batteries are sealed maintenance free,valve regulated & arranged in external battery cabinet acid cell battery of 4 nos 150AH capacity with (04)four years warranty as per dir of EIC(Make-PWD approved/AVO/Schneider-APC/VERTIV-Libert(Emerson)/Legrand/NUMERIC/Power One)
SITC of Green Model Cooler cum Purifier (Integrated inbuilt with cooler & purifier in a single unit) with 120 litres storage capacity. With external dimensions 750x570x1350mm ( ± 10%), (WxDxH), operating power supply-230 ± 10 % V AC, 50 Hz, running current in amps (max)-4.0 ± 10 %, Power in watts-850 ± 10 %, Water storage tank capacity-120 ltr, capacity with comfort level water outlet temperature at 17 deg c-60 lph, refrigent-R134 (Green Gas) 22, Compressor make- Emerson, thermal insulation for storage tank-puf, Total no. of faucets-03 (1 normal+2 cold), recommended max water flow rate through the faucets in lpm-1.5,no of stages for filter cum purifier-03,no of purifier circuits-03, purifier fault indication (buzzer), visual control (leds), water flow swith, 10 minutes UV auto shut off, storage tank material & body material- front SS 304 & rest pre coated steel, working with -0.4 kg/cc min. Water input pressure and 2 kg/cc of max. Water input pressure, integrated water cooler cum purifier with end point purification technology, including 1(one) year warranty as per condition. Make Eureka Forbes/Kent/Unilever
S/F of connector pipe for inlet and outlet with vent facility.(1/2" & 1/4" dia)
Supply of Steel lettering acrylic signages made of 22 SWG stainless steel enclosed except the facia. The facia should be made of acrylic. provision should be as such that Inside each letterHeat sinkable LED lights will glow throughout the letter. S/F of 25'x4'x10" ACP sheet of 4mm thickness fixed on iron frame, on which the letters will be fixed. Installation of the above mention board by expert labour on the roof parapit by cutting concrete and makig arrangement for holding the board by 1.5" iron angle. Making scrapholding arrangement upto the top of the 1st floor .incl S&F 32 mm steel channel on complete edge . The letter will be fixed on the board by steel nut bolt etc. Additional arrangement to support the board by iron structure grouted on roof and internal wiring connection as per direction of E.I.C
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles as per GS
Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm as per GS
S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) as per GS
Making soldered joints between conductor/ conductor & air terminals
Making soldered joints between conductor/ down pipes / other metallic objects
Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles as per GS
Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection for following size as per GS Length Upto 0.5 Mtr [ 4(a) / J1 ]
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation as per GS
Excavation of soil for installation of Earth Electrode and filling & ramming as per GS. For Morum Soil [1(b)/G-1 ]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With ISI-Medium GI pipe as per GS
M/S KUNDU CONSTRUCTION
RS SYSTEMS AND PROJECTS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .