SE EDC 2 MT
SE EDC 2 MT
TNO.33/EDC2MT/2025-26
2025_PVVNL_1050600_1
TNO.33/EDC2MT/2025-26
Open Tender
Electrical Works
Lump-sum
180 days
EDD MAWANA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
SE EDC 2 MT
₹5,000
31 Dec 2025
20 Jun 2025
27 Oct 2025
20 Jun 2025
27 Oct 2025
20 Jun 2025
Cartage of the following material from central store Meerut to J.E. store including loading & unloading at both ends (maximum distance up to 50 km.) (as per direction of Executive Engineer for successful completion of work.) 1-P.C.C. Pole 8.5 Mtr. Long.
2-Round Pole/ST Pole 11 mtr. Long.
3-Line material such as 11 K.V. cross arms/11 KV Pin insulator/conductor/GI Wire/MS angle & MS channel/stay wire/stay rod, disc fitting etc.
Cartage of the following material from store J.E. to site of work including loading & unloading at both ends (maximum distance up to 10 km.) 1-P.C.C. Pole 8.5 Mtr. Long.
2-Round Pole/PCC Pole 9.5 mtr. Long.
3-Line material such as 11 K.V. cross arms/11 KV Pin insulator/conductor/GI Wire/MS angle & MS channel/stay wire/stay rod, disc fitting etc.
Safe cartage of Transformer from central store Meerut to J.E. store of work including loading & unloading at both ends (maximum distance up to 50 km.) 1-63 KVA to 100 KVA
2-10 KVA to 25 KVA
Safe cartage of Transformer from J.E. store to site of work including loading & unloading at both ends (maximum distance up to 15 km.) 2-63 KVA to 100 KVA
3-10 KVA to 25 KVA
Erection of Round Pole/P.C.C. Pole 8.5 Mtr. Long including fixing all accessories and fabrication as required after digging a pit of size 1.20X0.75X1.75 Mtrs. 1-PCC Pole
2-Round Pole/ST Pole 11 mtr. Long.
Laying Lifting stringing and sagging of conductor complete in all respects as per RESPO norms. 1-Rabbit Conductor.
2-Weasel Conductor.
Erection fixing & grouting of stay rod size 16X1800mm after digging the pit of size 0.60X0.30X0.30 meter in ratio 1:4:8 including fixing of stay wire clamp and nuzzling at the both ends.
Earthing of PCC support with MS Earth rod of 2.5 Mtr. Long including excavation of pit & driving of MS rod up to proper depth & connection the earth electrode with the help of GI wire.
Straightening of tilled PCC Pole of 11 KV/LT Lines after opening the bindings from insulators and digging the pit for require depth and refilling the same pit after completion of work including rebinding the conductor with insulators & sagging the conductor.
Providing & fixing of following clamps for PCC Pole/STP, made of MS flat of size 50X6mm complete in all respect. 1-LT Pin Clamps with nut & bolt.
2-Shackle Insulator with nut & bolt.
3-Double Pole Clamps with nut & bolt.
Providing & fixing of stay clamp for PCC Pole/STP made of MS flat of size 50X6 mm complete in all respect.
Providing & fixing of Stay insulator in stay wire as per site requirement.
Mounting of 11/0.4 KV T/F on plinth & making connection of PVC Cable & Lead of HT/LT line. 1-63 KVA to 100 KVA
2-10 KVA to 25 KVA
Dismantling of PCC pole of existing line after opening all fittings and digging the pit of required size.
Cutting & Chopping of tree branches.
Dismantling of Damaged/Rusted STP/Rail pole of existing line after opening all fittings and digging the pit of required size.
Providing D-Type loop on each face & neutral.
Providing & fixing of bamboo sticks of required size on LT Line as per instructions of JE concerned.
Jumpering of 11 KV/LT Line at different places/T points.
Dismantling of D.P. including the work of dismanling of all accessories and connected HT/LT Line connections.
Removal of damaged/burnt conductor/GI wire after opening the bindings & making the role etc. 1-Rabbit Conductor
2-Weasel Conductor.
Replacement/Repairing of LT PVC Cable of existing T/F.: 1-63 KVA to 100 KVA
Cartage of Dismantled and removal material from site to J.E store including loading & unloading at both ends maximum distance about upto15 Km.
Cartage of Dismantled and removal material from J.E store to Central Store Meerut including loading & unloading at both ends maximum distance about upto15 Km.
Cartage of old/damaged T/F. from work site to JE Store including loading & unloading at both ends. 1-63 KVA to 100 KVA
Cartage of old/damaged T/F. from JE Store to Central Store Meerut including loading & unloading at both ends. 2-63 KVA to 100 KVA
Cartage of dismantled PCC Pole/STP from work site to JE Store (Distance up to 15 KM) including Loading & Unloading at both ends. 1-STP Pole
Dismantling of exsisting HT/LT Line by opening the binding at required place and rebinding the wire/conductor etc. as per site requirement to complete the work.
uksV%& 1- mijksDr dk;Z Øe la0 1 ls 40 rd dh ek=k iw.kZr vuqekfur gS rFkk dksbZ Hkh dk;Z 'kwU; ls vf/kdre ¼fufonk /kujkf'k dh lhek ds vUnj½ gks ldrk gSA 2- LohÑr izkdayu ds vUrxZr dk;Z djk;k tk;sxkA 3- jsLiksa ekudksa ds vuqlkj dk;Z djk;k tk;sxkA 4- mijksDr dk;Z esa vkbZVe okbZt izpfyr@ekfdZV jsV izkIr u gksus dh n'kk esa vkbZVe okbZt fuxksf'k,'ku djk;k tk;sxkA
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.27 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
BOQ_1909366.xls
BOQ • 0.25 MB
TenderForm33.pdf
Tender Documents • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .