Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 LAccepted-AOC NEAR PREMKANTA GAS AGENCY WARD NO 4 OLD DUDHICHUA ROAD MAIN ROAD SINGRAULI DISTT SINGRAULI M P PIN 486889 | SINGRAULI | SINGRAULI | MADHYA PRADESH | 486889 | ₹2.6 L | L1 | Accepted-AOC L1 bidder |
| Sl No | Description | Qty | Unit | Biswas Engineering Works L1 |
|---|---|---|---|---|
| 1.00 | Reapiring/checking testing & calliberation of over current relay (of 33 KV,11 KV,6.6 KV & 3.3 KV control panel)
A.Inverse type-13 NOS
B.IDMT-03 NOS
C.Instantenious -17 NOS
(All testing calibration and required equipment including tools & tackels should be arranged by the tenderer (Authorized agency for testing of relay) for above work.) | 33 | nos | 2,999 ₹98,967 |
| 2.00 | Reapiring/checking testing & calliberation of Earth fault relay (of 33 KV,11 KV,6.6 KV & 3.3 KV control panel)
A.Inverse type-10 NOS
B.IDMT-02 NOS
C.Instantenious -11 NOS
(All testing calibration and required equipment including tools & tackels should be arranged by the tenderer (Authorized agency for testing of relay) for above work.) | 23 | nos | 2,999 ₹68,977 |
| 3.00 | Reapiring/checking testing & calliberation of Earth Leakage (of 33 KV,11 KV,6.6 KV & 3.3 KV control panel)
A.Relay-10 NOS
(All testing calibration and required equipment including tools & tackels should be arranged by the tenderer (Authorized agency for testing of relay) for above work.) | 10 | nos | 2,999 ₹29,990 |
| 4.00 | Reapiring/checking testing & calliberation of Differential relay (of 33 KV,11 KV,6.6 KV & 3.3 KV control panel) -07 NOS
(All testing calibration and required equipment including tools & tackels should be arranged by the tenderer (Authorized agency for testing of relay) for above work.) | 7 | nos | 3,000 ₹21,000 |
| 5.00 | Total impact of GST for the purpose of CTC | 1 | Nos | - |
Tender Value
₹3.5 L
EMD Value
₹4,400
Closing Date
2 Aug 2024, 11:30 amClosed
SO(ENM), Jhingurda Project
SO(ENM) Office, Jhingurda Project
Repairing/checking, calibration and testing of different types of relay (protection system) installed in 33KV, 11KV control panel at main substation of Jhingurda mine
2024_NCL_312814_1
NCL/JRD/ENM/Tender/24-25/15 dt 17.07.24
Open Tender
Electrical and Maintenance Works
30 days
Jhingurda Project
AS PER NIT
4 documents required · 4 mandatory
₹4,400
5 Feb 2026
17 Jul 2024
3 Aug 2024
17 Jul 2024
2 Aug 2024
18 Jul 2024
17 Jul 2024 - 25 Jul 2024
Amount
Reapiring/checking testing & calliberation of over current relay (of 33 KV,11 KV,6.6 KV & 3.3 KV control panel) A.Inverse type-13 NOS B.IDMT-03 NOS C.Instantenious -17 NOS (All testing calibration and required equipment including tools & tackels should be arranged by the tenderer (Authorized agency for testing of relay) for above work.)
Reapiring/checking testing & calliberation of Earth fault relay (of 33 KV,11 KV,6.6 KV & 3.3 KV control panel) A.Inverse type-10 NOS B.IDMT-02 NOS C.Instantenious -11 NOS (All testing calibration and required equipment including tools & tackels should be arranged by the tenderer (Authorized agency for testing of relay) for above work.)
Reapiring/checking testing & calliberation of Earth Leakage (of 33 KV,11 KV,6.6 KV & 3.3 KV control panel) A.Relay-10 NOS (All testing calibration and required equipment including tools & tackels should be arranged by the tenderer (Authorized agency for testing of relay) for above work.)
Reapiring/checking testing & calliberation of Differential relay (of 33 KV,11 KV,6.6 KV & 3.3 KV control panel) -07 NOS (All testing calibration and required equipment including tools & tackels should be arranged by the tenderer (Authorized agency for testing of relay) for above work.)
Total impact of GST for the purpose of CTC
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid