| 1 | L1₹13.0 LAccepted-AOC CC III 28A JANTA BHAWAN ROAD SIRSA HARYANA 125055 | SIRSA | HARYANA | 125055 | L1 | Accepted-AOC L1 | |
| 2 | L2₹13.6 L+₹59,410 (4.56%)Rejected-Finance H NO 2049 HANUMAN COLONY NEAR TCP 3 HISAR CANTT PIN 125006 HARYANA | HISAR | HARYANA | 125006 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹13.6 L+₹60,205 (4.62%)Rejected-Finance GURU NANAK NAGAR GALI BHATIA DHARAMSHALA WALI SIRSA HARYANA PIN 125055 | SIRSA | HARYANA | 125055 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹14.0 L+₹1.0 L (7.67%)Rejected-Finance 62 KRISHNA CHAMBERS PHASE III AMRITSAR | AMRITSAR | AMRITSAR | PUNJAB | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹17.1 L+₹4.0 L (31.1%)Rejected-Finance NOT FOUND | L5 | Rejected-Finance Other than L1 |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
6 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) SIRSA
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (AF) SIRSA-125055
GE/SRA/T-64/2023-24
2024_MES_646748_1
GE/SRA/T-64/2023-24
Open Tender
Miscellaneous Works
Item Rate
240 days
GE (AF) SIRSA
PLEASE REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (AF) SIRSA
₹36,000
Yes
29 Apr 2024
16 Mar 2024
8 Apr 2024
16 Mar 2024
6 Apr 2024
25 Mar 2024
18 Mar 2024 - 21 Mar 2024
Amount
AIR CONDITIONER
M&L for servicing of Split AC 1.5/2 Ton Capacity by taking out/down from existing position/location and re-installation after including checking the serviceability of electrical/electronic circuits, relays, wiring kit, thermostat switches, knobs, remote control unit including PCB, fan, blower, etc, changing electrical connections and keeping the AC unit in satisfactory working condition after necessary servicing / repair / replacement of defective spares, Washing and Cleaning Cooling Coil by providing water bag so that water does not spill on floor and cleaning Condenser along with Fittings First with Air Blower, then with spraying with coil cleaning chemical (Non-acidic type) (Like MPC-AC-102 or equivalent) of best quality in Coil and Condenser, then washing with Plain Fresh Water with the help of high pressure water gun until all Chemicals are removed and Testing, complete all as specified and as directed. NOTE: 1. Water bag for the servicing so that water does not spill on floor shall be provided by contractor at no extra cost. 2. De-Scaling chemical shall be measured separately 3. Replacement of parts, if required shall be measured and paid separately under respective items here-in-after
All as per srl item No 1.01 here-in-before but for 1.5/2 TR Window Type AC complete all as specified and as directed.
S&F in repair Starting Relay Assembly with Cover & Clip suitable for AC 1.5/ 2.0 Ton capacity, Split type complete all as specified and as directed.
S&F in repair Over load protector for compressor suitable for 1.5 /2.0 TR compressor complete all as specified and directed
S&F in repair thermostat switch for 1.5 /2 TR split/window AC complete all as specified and directed.
S&F in repair starting capacitor suitable for any type of reciprocating/rotary compressor 80-100 Mfd capacity in metal container all as specified and directed.
S&F in repair starting capacitor suitable for any type of reciprocating/rotary compressor 120-150 Mfd capacity in metal container all as specified and directed.
S&F in repair running capacitor 36 Mfd capacity in metal container pin type all as specified and directed.
S&F in repair running capacitor 50±4 & 6 Mfd capacity in metal container pin type all as specified and directed.
S&F in repair running capacitor 2.5/4/6/10 Mfd capacity in metal body pin type all as specified and directed.
S&F in repairs Suction/discharge copper pipe line heavy duty up to 1/4'' dia and flair nuts from indoor to outdoor unit of split AC 1.5 /2 TR capacity all as specified and directed.
S&F in repairs suction/discharge copper pipe line heavy duty 5/8" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
S&F in repairs PVC pipe nylon imbraided 15 mm dia for condenser water drain fitted with fixed to Wall with necessary Mild Steel Clamps, Screws, etc complete all as specified and directed.
S&F Insulation Sleeve type of Best quality for Copper Tubing for copper Pipe /Foam insulation for copper tubing of size up to 3/8'' dia complete all as specified and directed.
S&F in repair new condensing unit of split type AC of 1.5/2.0 Window type AC of any capacity complete with condensing copper coil, coil frame, wiring kit and running capacitor, relay condensing motor with blade complete all as specified and directed.
S&F in repair blower motor of 1.5/2 TR split AC (indoor unit) /Window AC any type as per OEM complete all as specified and directed.
S&F in repair new condenser motor of 1.5/2 TR split AC (outdoor unit) as per OEM incl replacement of bearing bushing etc complete all as specified and directed.
S&F in repair new swing motor of 1.5/2 TR split AC (indoor unit) as per OEM complete all as specified and directed.
Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-22 type in required quantity complete all as specified and directed.
Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-134/R410/R-32 type in required quantity complete all as specified and directed.
Supply and charging the AC unit of 1.5/2/2.5/3.5/4.5 TR split type AC unit with Nitrogen Gas for detecting of leakages required as per site quantity complete all as specified and directed.
S&F in repair of suction/discharge valve size up to size 3/8" complete all as specified and directed .
S&F in repairs of air filter made out of Nylon suitable for 1.5/2 TR capacity split AC of any Make and model complete all as specified and directed.
M&L for carrying out fault finding with pressure leak test of Split Type ACs 1.5/2 TR capacity by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak, checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all as specified and directed.
M&L carrying out fault finding test with pressure leak test of 1.5 /2TR window AC by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all as specified and directed.
S&F in repair new PCB (printed circuit board) along with new cordless remote, visual eye demo plate and connected wiring of indoor unit of Split AC of capacity 1.5 TR complete all as specified and directed.
'All as per srl item No 1.26 here-in-before but for 2.0 TR capacity Split AC
S&F in repairs front grill for window AC of 1.5 TR /2TR of existing make complete all as specified and directed.
S&F Bottom tray of 1.5 ton /2 ton capacity of window type AC made out of 14 SWG mild steel sheet including painting with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Taking out/Dismantling/Shifting of existing AC 1/1.5/2.0 Ton Split type and windows type AC of any capacity, including Outdoor and Indoor Unit & Re-installation of Compressor Unit of AC 1.5/2.0 Ton Split type and then Re-fixing of Air Conditioner complete with both units on wall with necessary Mild Steel Stand, providing connection of Copper Pipes of Compressor/Air Conditioner Unit the Pipe connection should be leak proof including necessary brazing of Pipes required, providing proper insulation of Copper Pipes as per requirement Installation of Voltage Stabilizer, making connections of Electric Cable of Compressor with Air Conditioner and further to Voltage Stabilizer and Power Point including Provision of Extra quantity of Flexible Copper Conductor Cable 3 Core 1100 of size 40/0.0076 and Top Plug 15 Amp, complete all as specified and as directed. NOTE :- 1) Requirement of electric connection cable, drain pipe and topping up of refrigerant gas to be measured and paid shall be deemed to be included in quoted unit rates.
S&F in repair Compressor sealed unit for Split type Air Conditioner of capacity 1.5 tonne reciprocating compressor of any make as per site, by removing of old burnt compressor and fixing as per manufacturer instruction including providing connections of gas line, fixing of copper tubes of suitable sizes, hand shut off valves, relays, replacement of strainer, rubber pads for foundation, starting and running capacitors, Nuts and Bolts, etc. and testing on completion complete all as specified and as directed. NOTE :- (a) Dismantling and re-installation of outdoor unit shall deemed to be included in Quoted Unit Rate. (b) Charging of refrigerant shall be deemed to be included in Quoted Unit Rate
All as per item No 1.31 but for 2.0 TR capacity reciprocating compressor
All as per item No 1.31 here in before but 1.5 TR capacity rotary type compressor
All as per item No 1.31 here in before but 2 TR capacity rotary compressor
S&F in repair Compressor sealed unit of Window type Air Conditioner of capacity 1.5 / 2.0 TR, reciprocating type compressor of any make as per site, by removing of old burnt compressor and fixing as per manufacturer instruction including providing connections of gas line, fixing of copper tubes of suitable sizes, hand shut off valves, relays, replacement of strainer, rubber pads for foundation, starting and running capacitors, Nuts and Bolts, etc. and testing on completion complete all as specified and directed. NOTE :- (a) Dismantling and re-installation of outdoor unit shall deemed to be included in Quoted Unit Rate. (b) Charging of refrigerant shall be deemed to be included in Quoted Unit Rate by removing old burnt compressor and fixing as per manufacturer instruction including providing connections of gas line, fixing of copper tubes of suitable sizes complete all as directed by the Engr-in-Charge.
All as per item No 1.35 here in before but 1.5/ 2 TR capacity rotary type compressor
S&F in repair Condenser fan blade suitable for 1.5/2 TR capacity Split type Air Conditioner complete all as specified and as directed.
S&F in repair Roller runner, suitable for 1.5/2.0 TR capacity Split type Air Conditioner complete all as specified and as directed.
S&F in repair powder coated metallic stand (02 nos) for fixing outdoor units of Split Type Aces of 1.5/2.0 TR capacity complete all as specified and directed.
M&L Cutting openings, through brick wall for fixing of window type Air Conditioner including necessary wooden frame work not less than 2" by 2" thick size as per AC model including fair finish of side walls in cement mortar (1:6) with three coats white wash, painting of wooden surfaces with two coats of synthetic enamel paint over a coat of pink primer, cleaning and stacking bricks removing surplus serviceable bricks, hard-core and rubbish etc from site complete all as specified and as directed.
S&F in repair Single phase preventer 415 type SPPR (Auto reset 540 volts un balance) complete all as specified and as directed.
S&F in repair power contactor 2 pole/3 pole, coil voltage 230 Volts of capacity 25 Amps Complete all as specified and directed.
S&F in repair timer single phase analogue type 230 volts complete all as specified and directed.
S&F in repair remote control hand set for 1.5/2.0 TR capacity split AC and window type AC complete all as specified and as directed.
M&L for servicing including cleaning of condenser coil fins with mild detergent, cleaning of indoor unit and descaling of condenser coil for Vertical type 3 phase Air Conditioner, of any make/capacity after taking down the outdoor unit and refixing in the existing location or any where and replacement of insulation of suction & discharge line complete all as specified and as directed.
Supply only descaling chemical non-acidic foaming type (Like MPC-AC-102 or equivalent for servicing of Split/Window AC complete all as specified as directed.
M&L for fault finding in Auto Circuit Plate 220 Volt, 50Hz suitable for following make of AC Voltas/LG/Blue Star/ Carrier/Hitachi/Samsung 1.0/1.5/2.0 Ton AC of any type (Window/Split) and rectifying the fault by replacing the whichever part is defective i.e. capacitor, resistor, varistor, IC chip, capacitor, relay or any other part that is required to rectify the fault including taking out/ down and refitting the auto circuit plate, complete all as specified and as directed.
REFRIGERATOR
Dismantling of defective refrigerator of any make and capacity including transportation to workshop and back for thorough checking of all accessories and components, repairs and reassembling the same after repair/ replacement of defective accessories/components and testing complete all as directed by Engr-in-charge .
S&F Thermostatic defrost type Switch suitable for refrigerator of any description including taking out/ down unserviceable one, complete all as specified and as directed.
M&L in repair Sealed Compressor suitable for Refrigerator 120 to 170 Litre including brazing of Copper Pipe, cleaning of Refrigerant System, Charging of Refrigerant and Compressor Oil, replacement of Foundation Rubber Bushes, Nuts and Bolts, etc. and Testing on Completion including taking out/down defective/burnt Sealed Compressor and connected Items, complete all as specified and as directed.
M&L Sealed Compressor suitable for Refrigerator 286/310/315 Litre including brazing of Copper Pipe, cleaning of Refrigerant System, Charging of Refrigerant and Compressor Oil, replacement of Foundation Rubber Bushes, Nuts and Bolts, etc. and Testing on Completion including, Taking out burnt compressor after disconnecting suction and discharge line and fixing new compressor as per existing including testing complete all as specified and directed for Refrigerator of Capacity 285/310 Litres complete all as specified and directed.
M&L Cleaning Gas System with suitable chemical, charging of Refrigerant, preventing of leakage in the System, providing Refrigerant with anti-moist substance and Strainer, Copper Capillary including replacement of Filter of Refrigerator 120 to 170 Litre, Testing on Completion, complete all as specified and as directed.
M&L Cleaning Gas System with suitable chemical, Charging of Refrigerant, preventing of leakage in the System, providing Refrigerant with anti-moist substance and Strainer, Copper Capillary including replacement of Filter of Refrigerator 286/310/315 Litre, Testing on Completion, complete all as specified and as directed.
S&F PTC Relay with overload suitable for refrigerator of capacity 165/190/200/310 ltrs complete all as specified and directed
S&F PCB with Wiring set complete consisting of PVC insulated flexible wire with stranded copper conductor of size 1.5 sqmm and fixing clips for refrigerator all types.
S&F PCB timer of refrigerator 180-310ltrs required as per site complete all as specified and directed
S&F Condenser coil for 250 to 310 Litres complete all as specified and directed
DESERT COOLER
S&F in repair Fan Leaf of best quality suitable for Desert Cooler of any Make and size complete all as specified and as directed.
S&F in repair Front Grill Double Partition type of 20 SWG, best quality (as approved) of suitable size for Desert Cooler providing making Electric Connection to all Accessories as required complete all as specified and as directed.
S&F in repair Motor Kit suitable 1/7 HP, 180 Watt, 3 speed for Desert Cooler, Copper wounded complete and One Set of Lugs for mounting body complete all as specified and as directed.
S&F in repair Plastic PVC Distributor suitable for Desert Cooler heavy duty 15mm with Elbow, Tee, etc. fixed with Bolts, Nut & Washers complete all as specified and as directed.
S&F in repair Plastic PVC Pipe of 15mm bore suitable for Desert Cooler, heavy duty, ISI mark complete all as specified and directed.
S&F in repair Running Capacitor 2.5/4/6mfd suitable for Fan Motor of Desert Cooler complete all as specified and as directed.
S&F in repair Submersible Water Pump suitable for Desert Cooler complete all as specified and as directed.
S&F in repairs Mild Steel Desert Cooler Body of 22 SWG Powder Coated with 03 Nos Side Shutters of size 3ft x 2ft x 2ft minimum size, Noise Pollution Control complete Body complete all as specified and as directed.
M&L Taking out Fan Motor from Desert Cooler any size and Make, 230 Volts, 50 Cycles, removing burnt Winding Wire, rewinding the Motor with super enamelled Copper Winding Wire of suitable size and providing insulation along with insertion of superior type of Insulating Materials, winding, Varnishing and drying well after Varnishing, replacement of Shaft, Gun Metal Bushes and Rubber Bushes for Blower Motor, testing on load after fixing, complete all as specified and as directed.
S&F in repair Mild Steel stand for supporting fan motor of desert cooler including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed
S&F in repair Wood Wool Pad (as approved) suitable for Desert Cooler, heavy duty and best quality complete all as specified and as directed.
M&L preparing old surfaces of Desert Cooler Body by de-scaling, rubbing, brushing, cleaning and applying one coat of Synthetic Enamel Paint (as approved) with Spray Gun Machine on outer surfaces of body and tank including painting inside of tank with one coat of Black Bituminous Paint complete all as specified and as directed.
WATER COOLER
S&F in repair Fan Motor with copper winding suitable for water cooler 40/80 Litre complete with Blades complete all as specified and as directed.
S&F in repair Fan Motor with copper winding suitable for water cooler 120/120 Litre complete with Blades complete all as specified and as directed.
S&F in repair Capacitor of any size and make suitable for compressor of Water Cooler 40/120/150 Litre capacity complete all as specified and as directed.
S&F in repair Self Closing Tap Brass Chromium plated 15mm suitable for Water Cooler of any capacity complete all as specified and as directed.
S&F in repair Sealed Compressor Unit suitable for Water Cooler 40/80 litre capacity including brazing of Copper Pipe, cleaning of Refrigerant System, Charging of Refrigerant and Compressor Oil, Replacement of Strainer, Capillary, Rubber Pads for Foundation, Nuts and Bolts, etc. and Testing on Completion complete all as specified and as directed.
S&F in repair Sealed Compressor Unit suitable for Water Cooler 120/150 Litre/hr cooling capacity including brazing of Copper Pipe, cleaning of Refrigerant System, Charging of Refrigerant and Compressor Oil, Replacement of Strainer, Capillary, Rubber Pads for Foundation, Nuts and Bolts, etc. and Testing on Completion complete all as specified and as directed.
M&L for Cleaning Gas System with suitable chemical, Charging of Refrigerant, preventing of leakage in the System, providing Refrigerant with anti-moist substance and Strainer, Copper Capillary including replacement of Filter of Water Cooler 40 Litre/hr cooling capacity and Testing on Completion complete all as specified and as directed.
M&L for Cleaning Gas System charging of Refrigerant, preventing of leakage in the System, providing Refrigerant with anti-moist substance and Strainer, Copper Capillary including replacement of Filter of Water Cooler 120/150 Litre/hr cooling capacity and Testing on Completion complete all as specified and as directed.
S&F in repair Thermostat including plastic regulating knob as per existing for water cooler of cooling capacity 40/80/120/150 litres complete all as specified and directed
S&F in repair Relay for water cooler type suitable for water cooler storage cooling capacity 40/80/120/150 litres/hrs complete all as specified and directed
S&F in repair Over load protector for compressor suitable for water cooler of capacity 40/80 /120/150 Litres complete all as specified and directed
S&F in repair Self closing bib tap/push tap 15mm dia, chromium plated steel suitable for water cooler 40/80/150/120 litre/hrs capacity complete all as specified and directed..
DEEP FREEZER
S&F in repair Sealed Compressor Unit suitable for Deep Freezer 400/500 Litre including brazing of Copper Pipe, cleaning of Refrigerant System, Charging of Refrigerant and Compressor Oil, Replacement of Foundation Rubber Bushes, Nuts & Bolts, etc. incl testing on Completion complete all as specified and directed.
M&L for Cleaning Gas System with suitable chemical, Charging of Refrigerant, preventing of leakage in the System, providing Refrigerant with anti-moist substance and Strainer, Copper Capillary including replacement of Filter of deep freezer and Testing on Completion complete all as specified and as directed.
S&F in repair fan motor suitable for deep freezer of any type capacity 400/500 Litre including necessary connection complete all as specified and as directed.
S&F in repair Relay for deep freezer of any size/capacity complete all as specified and directed
S&F in repair Overload for compressor of deep freezer of any size/capacity complete all as specified and directed
S&F in repair Thermostat for deep freezer complete al as specified and directed
VOLTAGE STABILIZER
Supply & installation in repairs voltage stabiliser automatic operation single phase naturally air cooled designed for input variation between 170 V to 250 V with output voltage 230 V with accuracy + 2.5% and of capacity 5 KVA complete all as specified and directed.
MISC ITEMS
Supplying, assembling and fixing in repairs on wall, Modular MCB protected Power Unit comprising of following accessories :- (i) Powder Coated Steel terminal box, 06 module - 01 No (ii) Modular Cover Plate with Frame, 06 Module - 01 No (iii) 16 Amps 3 Pin Modular Socket, 02 module - 01 No (iv) 16 Amps Plug Top - 01 No (v) 25 Amps Motor Starter, 02 Module - 01 No (vi) 25 Amps, Single pole Mini MCB, 10kA - 01 No
Supplying, assembling and fixing modular AC power unit comprising of 01 No 16 Amps socket and 01 No 32 Amps SP MCB, 3 modules along with 1.2 mm thick GI metallic flush box, cover plate and frame duly concealed in wall incl taking out existing unsv power unit complete all as specified and directed. NOTE: Quoted rate shall be deemed to include for the cost of MCB, socket, GI flush box, cover plate & frame.
S&F in repair 32 Amps modular motor starter with cover plate & frame, 2 modules along with 1.2mm thick GI metallic flush box duly concealed in wall complete all as specified and directed. NOTE: Quoted rate shall be deemed to include for the cost of cover plate & frame and GI flush box along with starter.
S&F in repair Plug Top, 3 Pin, 5/6 Amp complete all as specified and as directed.
S&F in repair Plug Top, 3 Pin, 15/16 Amp complete all as specified and as directed.
S&F in repair PVC Round Flexible 3 Core Copper Connection Lead of size 2.5 Sqmm, 3 meter long with plug complete all as specified and as directed.
S&F in repair MCB 32 Amp, Single Pole, 220 Volt, 50 Hz, 10 kA with Thimbles, etc complete all as specified and as directed.
S&F in repair MCB 25 Amp, Single Pole, 220 Volt, 50 Hz, 10 kA with Thimbles, etc complete all as specified and as directed.
S&F in repair 20 Amp metal socket with earth for AC box complete all as specified and as directed.
S&F in repair 20 Amp metal plug with earth for AC box complete all as specified and as directed.
S&F in repair 20 Amp AC box with metal plug and socket without MCB complete all as specified and as directed.
M&L for making holes of required dia on walls of any type and thickness for connecting copper pipes of indoor and outdoor units of Split ACs 1.5/2.0 TR by core cutting drill machine as per site requirement and making good the disturbed surfaces by plastering etc duly painted as per existing finishes complete all as specified and directed.
GENERAL NOTES FOR ALL ITEMS :- (1) The works for repair of ACs and other connected refrigeration works shall be got carried out through experienced and qualified refrigeration mechanics. Necessary documents wrt qualification/experience shall be submitted by the contractor to Engineer-in-Charge before commencement of refrigeration works. (2) Defective spares for making the ACs, Refrigerators, Water Coolers, Deep Freezer units in satisfactory working condition will be measured & paid separately under relevant items. (3) Major type of spares have been considered in BOQ. Quoted rate is deemed to be inclusive of consumables and minor spares, nuts, bolts etc. No claim shall be admissible in this regard during execution of work. (4) Make of spares, accessories shall be as per OEM or as approved by GE in writing. (5) All the complaints to be attended by contractor on same day if the same complaint remaining unattended to next working day a penalty of Rs 100.00 per day shall be levied on contractor. (6) The faulty items which were replaced to be produced to concern JE in charge, before taking to credit if the items not produced then a recovery of 2% shall be charged against quoted rates. (7) After completion of complaint a copy of user/occupant signature to be obtained and deposit to concern JE.
STAR CONSTRUCTIONS
BHATIA ENTERPRISES
NATIONAL CONSTRUCTION COMPANY
shiv shanker enterprises
M/s Sheoran Brothers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .