Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.0 LAccepted-AOC 79 MAHATMA GANDHI MARKET SRI VIJAYA PURAM 744101 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹39.9 L+₹91,338 (2.34%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹39.9 L+₹99,602 (2.56%)Rejected-Finance DAIRY FARM JUNCTION VIJAY BAUGH ROAD SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹41.4 L+₹2.4 L (6.16%)Rejected-Finance 30 M A ROAD M A ROAD PHOENIX BAY SOUTH ANDAMAN ANDAMAN NICOBAR 744102 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744102 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹42.6 L+₹3.6 L (9.30%)Rejected-Finance 956 2 CHANDERSEKER ENTERPRISE OPP MARICAR HOSPITAL OLD CCS JUNGLIGHAT SOUTH ANDAMAN ANDAMAN NICOBAR 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹28.5 L
EMD Value
₹57,000
Closing Date
9 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Haddo
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
PROVISION OF 03 x 15 KVA GENERATORS ALONGWITH ASSOCIATED BUILDING AND E/M FITTINGS FOR ASR RADAR OF IUHDSS AT NSCB ISLAND (ROSS ISLAND) UNDER GE HADDO, PORT BLAIR
2023_MES_575038_1
8716/GE/H/PB
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer Haddo Port Blair
Class D and Category b(i)
9 documents required · 9 mandatory
₹500
GE Haddo
₹57,000
Yes
2 Mar 2023
14 Jan 2023
13 Feb 2023
14 Jan 2023
9 Feb 2023
28 Jan 2023
16 Jan 2023 - 23 Jan 2023
Amount
Excavation in post holes (or similar holes) each n. exc 0.5 Cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers n. exc 25 cm in hard/dense soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m deep and 1.5m width and getting out in soft or loose soil for foundation of poles (or) cable laying complete all as specified and as directed.
Returning, filling including spreading, levelling, watering and well ramming layers not exc 25m for cable laying complete all as specified and directed.
Removing / excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for cement concrete (1:3:6) type B1 using 20mm graded stone aggregate as in foundation filling and mass concrete complete all as specified & directed by Engineer-in-Charge.
S&F for pre painted Galvalume aluminium zinc coating GI based corrugated / trapezoidal section of steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa (AZ 150) as in roof covering fixed with self tapping screws complete all as specified and as directed.
S&F for pre painted Galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa (AZ 150) as in roof covering fixed with self tapping screws complete all as specified and as directed.
M&L for aluminium wind tie of any size fixed with self tapping screws of aize 50/75mm with integral EPDM washer in roof covering complete all as specified and as directed.
S & F rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates Fe 410-w(Gde-E-250 ) quality A complete all as specified and as directed.
M&L for mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W (Gde E-250) Quality 'A' complete all as specified and as directed.
S & F for mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410-W (Gde E-250) Quality -A complete all as specified and as directed.
M&L for preparation of new steel surfaces over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and as directed.
M & L for hardcore of gauge not exc 63 mm deposited spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface of broken stone or boulders complete all as specified and directed,
M&L for 100mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base of floors complete all as specified and as directed.
M&L for Providing 100mm thick plain cement concrete (1:2:4) Type B1 (20 mm graded aggregate) as in floors finishing the surface of concrete toping even and fair without using extra cement, complete all as specified and directed.
M&L for forming contraction (Dummy) joints 65mm deep x 10mm wide, filed with sealing compound Grade A complete all as specified and directed.
Supply,laying,testing and commissioning of LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of cross section 95 sqmm 3.5 core (laid in terenches,ducts,pole,wall etc.) all as specified and directed. Make : Polycab/Gloster/Anchor/Havells/ Finolex
Supply,laying,testing and commissioning of LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of cross section 25 sqmm 3.5 core (laid in terenches,ducts,pole,wall etc.) all as specified and directed. Make : Polycab/Gloster/Anchor/Havells/ Finolex
Supply,laying,testing and commissioning of LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of cross section 16 sqmm 4.0 Core (laid in terenches,ducts,pole,wall etc.) all as specified and directed. Make : Polycab/Gloster/Anchor/Havells/ Finolex
Supply and laying HDPE DWC pipe of size 77mm (OD) x 63mm (ID) along with connected accessories like couplers, bends, end caps etc. for LT/ HT cable protection complete all as specified and as directed by engineer in charge. Make: Rex Poly Extrusion Ltd/ Tirupati Plastomatics Pvt Ltd.]
M&L for HDPE DWC (Double wall corrugated) pipe of size 50mm (Outer diameter) x 38mm (Inner diameter) along with connected accessories like couplers, bends, end caps etc., laid in trenches/floors/ducts or fixed on poles/walls for as in protection of LT/ HT cable complete all as specified and as directed. Make : REX POLYEXTRUSION LTD/ Tirupati plastomatics Pvt Ltd
Supply, Installation, testing and commissioning of econ friendly silent diesel engine driven generating set silent DG set for automatic starting on mains failure to give an output of 15 KVA at 415 volts, 3 phase 50 cycle per second 4 wire 0.8 power factor, required BHP, noise level as per CPCB norms complete with diesel engine water cooled mounted on a common base plate with floor mounted and fuel tank including earth work in PCC foundtaion with vibration pads and other accessories. Make : Greaves Cotton Ltd / CUMMINS / KOEL/ KIRLOSKAR/Geaves Power A.ENGINE :- Diesel driven 4 cylinder water cooled 1500 RPM suiltable alternator 15 KVA under NTP condition, governing class as per ISO 3046, 10% over loading for 1 hour in 12 hour running. i) Fly wheel to suit coupling. ii) Flexible coupling with guard bolt and nuts. iii) Oil type air cleaner. iv) Radiator with guard and fins and radiotor fins. v) Fuel pump complete with fuel injectors. vi) Governor vii) Fuel filter viii) Lubricating Oil filter. ix) Self starter x) Exhaust silencer with pipe. xi) Instrumental panel complete with the following :- a) Self starting key and switch b) Lubricating oil pressure guage. c) Battery charging alternator. d) Hours meter amd Ampere meter e) Temperature Guage.
B. Alternator:- It shall be self excited, self regulated, balanced type for 415 Volts, 3 phase, 50 Hz 15 KVA or nearest in higher size 1500 RPM star connected 4 wire, protection, IP23 drip proof screw protected self ventilated enclosure as IS: 4722/BS:2613 with drip proof enclosure with damper winding on pole faces, static automatic and hand voltage regulator to provide regulation ± 1 % from no load to full load power factor and insulation as per standard practice. C. AMF CONTROL PANEL :- Fabricated out of suitable CRCA sheet cubical type mounting in Acoustic enclosure, state of the art compact micro processor based fully configurable operating with the following:- i) AC Voltmeter of suitable range ii) AC Amps meter of suitable range iii) Power factor meter iv) Frequency meter v) Aluminium Bus Bar of suitable capacity vi) MCCB capacity of 32 Amps to 40 Amps 3 pole vii) Suitable size of contactors and Auto/Manual switch. D. Baterry :- Starting battery 12 volts. Suitable rating maintenance free with copper lead of suitable length with lugs 01 set and brass terminal placed on angle iron standard frame. E. Base Plate :- Base plate of MS Channel fabricated and wleded duly ribbed suitable for mounting alternator along with coupling and tray. F. PCC :- PCC founadtion shall be as per manufacturer drawing/design G. Battery charger 12 volts suitable for charging 01 no. battery
H. Supply and fixing including assembly the above DG set in high quality acoustic enclosure of suitable dimension as per manufacturer recommedation.The enclosure shall ne designed on modern construction having surface treatment like degreasing, pickling, phosphate, passivation and powder coating finished. The acoustic insulation shall be of high quality, high density. The enclosure shall be provided with the follwoing:- i) Acoustic enclosure must have center lifting arrangement ii) High temp safety for enclosure iii) Special lockable doors iv)EDPM qulaity gasket v) Engine and alternator shall be mounted through AVM pads on a common channel iron fabricated base frame to rest gross weight of DG set unit. vi) Noise level of 75 DB at 1 mtr distance controlled by providing specially designed to control the sound at air entry exist of the enclosure. Note:-(i) The components i.e engine, alternator, panel etc of all the DG sets shall be procured from the OEM (ii) Engine and alternator of same make shall be preferred in case both are being maunufactured by the same manufacturer or alternator as recommended to use by the manufacturer shall be allowed. No price adjustment on this account shall be made and No misunderstanding on this account shall be entertained at later. Contractor quoted rate shall be deemed to be included for this aspect. (iii) The emission standard parameters of DG Set should meet as per specified in the advisory issued by E-in-C's Branch letter No. A/37696/Gen/Pol/E2W (PPC) dt 29 Jun 2022. (iv) Rates quoted are deemed to be included foundation of DG set as approved by OEM. No extra payment for foundation will be paid to Contactor. (v) The quoted rate are deemed to incl the cost of transportation of DG Sets & AMF Panel from Port Blair to NSCB Island. (vi) 12 hours continuous testing of DG Set at diffrent loads, will be carried out by IEM. The Cost of disel and testing equipment is deemed to be included in the quoted rate.
Supply and Fixing of outdoor LT Panel box of dimensions 90cm length x 75cm width x 70cm height size with approved Main frame 3mm thick powder coated CRCA sheet, partition sheets / covers / doors of 3 mm thick CRCA sheet, gland plates 3 mm thick MS sheet (undrilled) with provision of incoming cable at bottom and outgoing cable at the top for outdoor installation, free standing floor mounted with degree of protection IP 65 and locking arrangements for mounting 4pole 250Amps MCCB with alluminum bus bar, sleeving heat shrinkable type, with bus bar sizes for phase 40mmx10mm aluminium flat (03Nos) and neutral 25mmx10mm aluminium flat and bus bar support of epoxy type including PCC work and making good after completion of work complete all as specified and directed.
S & F DB VTPN sheet metal enclosure double door IP 43 protection, door earth suitable for incoming upto MCCB 100 Amps/200 Amps & outgoing MCB TP / SP. Triple pole and neutral 415 V 4 Way with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete and making good to the distrubed surface /walls all as specified and directed. Make : Indo Asian/Havells/L&T/Legrad
S&F in repair MCCB, 3 pole, 100 Amps, 50Hz, 25KA rupturing capacity, 415 Volts adjustable type with thermal and magnetic release complete all as specified and as directed. MAKE: INDO ASIAN/ L&T/ LEGRAND/ HAVELLS
S&F in repair MCCB, 3 pole, 63 Amps, 50Hz, 25KA rupturing capacity, 415 Volts adjustable type with thermal and magnetic release complete all as specified and as directed. MAKE: INDO ASIAN/ L&T/ LEGRAND/ HAVELLS
S&F MCB, SP, "C" series, 240 volts, 6 to 32 Amps, 10 KA rupturing capacity complete all as specified and as directed. MAKE: INDO ASIAN /L&T/ LEGRAND/ HAVELLS
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 125 Amps all as specified and as directed.
M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6.15mm thick, 40mm bore buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to 32x6mm GI earth strip as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion including demolition of old unserviceable earth pit and taking out earthing material from pit complete all as specified and directed. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
Demolition of cement concrete in ground floors and pavings n exc. 15 cm thickness (belove or above ground level) specifically provided for etc complete all as specified and as directed.
M&L for Cement concrete P.C.C (1:4:8) Type D2 (using 40 mm graded aggregate) as in sub base, foundation or mass concrete complete all as specified.
M&L for 100mm thick PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in sub base, finish the top surfaces even and fair complete all as specified and as directed.
M&L for 100mm thick PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in hardstanding / path laid in panels, finish the top surfaces even and fair complete including filling the joints with mastic compound, spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green complete all as specified and as directed.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in coping, edging including necessary form work complete all as specified and directed.
Taking down cement plaster of any description on brick or stone walls etc., including raking out joints, hacking for key, scrubbing down with water etc., and removal of debris to outside MD land complete all as specified and as directed.
M&L for plastering 15mm thick in CM (1:4) mixed with liquid water proofing compound @ 200ml per 50kg cement bag on fair faces of brick work or concrete, surfaces finished even and smooth without using extra cement complete all as specified and as directed. NOTE: Water proofing compound will be measured and paid separately under relevant item of this schedule.
Supply only liquid water proofing compound.
M&L for preparation of newly plastered surfaces and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed
CITY CONSTRUCTION COMPANYU
Sree Tirumala Enterprises
ISLAND SALES ENTERPRISES
CHANDER SEKER ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .