MR Ahammad Danish
CE(Raipur)
NECESSARY OUTER DEVELOPMENT WORK SUCH AS :- RENEWAL OF RAOD ,LENGTH 8 K.M., DRAIN-CULVERT, LAND SCAPING & OUTER BOUNDRY WALL , UTILITY SHIFTING & OTHER ESSENTIAL WORK OF RAJBHAWAN, HONORABLE CHIEF MINISTER'S & HONORABLE MINISTERS CONSTRUCTED CAPMUS AT RAIPUR .DISTT. RAIPUR.I/C. ELECTRIFICATION WORK.(DN. NO.3, NAWA RAIPUR).( EXCEPT FOR RENEWAL OF ROAD ,LENGTH 8 K.M., DRAIN-CULVERT).
203205
NIT NO: 1141TC/2026-27
OPEN TENDER
WORKS
ITEM RATE
18 days
CE(Raipur)
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
17 documents required · 17 mandatory
Public Works Department (PWD)
WORKS
MR Ahammad Danish
OPEN TENDER
ITEM RATE
OPEN TO ALL
CE(Raipur)
PWD Circle-1,Raipur
Pwd Div No3 Raipur
120
18
No
637
203205
23 Nov, 2026 5:00:00 PM IST
27 Nov, 2026 10:00:00 AM IST
2 Nov, 2026 5:00:00 PM IST
NIT NO: 1141TC/2026-27
NECESSARY OUTER DEVELOPMENT WORK SUCH AS :- RENEWAL OF RAOD ,LENGTH 8 K.M., DRAIN-CULVERT, LAND SCAPING & OUTER BOUNDRY WALL , UTILITY SHIFTING & OTHER ESSENTIAL WORK OF RAJBHAWAN, HONORABLE CHIEF MINISTER'S & HONORABLE MINISTERS CONSTRUCTED CAPMUS AT RAIPUR .DISTT. RAIPUR.I/C. ELECTRIFICATION WORK.(DN. NO.3, NAWA RAIPUR).( EXCEPT FOR RENEWAL OF ROAD ,LENGTH 8 K.M., DRAIN-CULVERT).
500000.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
442774000.00
2
26 Nov, 2026 5:00:00 PM IST
442774000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
23d 2h 24m
17 documents required · 11 mandatory · 6 optional
₹0
₹5 L
30 Oct 2026
30 Oct 2026
27 Nov 2026
2 Nov 2026
26 Nov 2026
Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m lift and lead upto 50m (at least 5m away from the dressed area).
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits. 1.1.1) In all types of soils.
In ordinary rocks.
Extra for every additional lift of 1.5 m or part thereof. 1.6.1) All types of soils
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 3.1.3) 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size).
1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. (Note :Excess/ less cement used as per design mix is payable/ recoverable separately) 3.2.1) 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 3.3.1) M-20 Grade
M-25 Grade
Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Extra for precast PCC/ RCC work of any mix including form work, hoisting and fixing in Cement Mortar. 1:2 (1 Cement : 2 coarse sand) and finishing with cement plaster in Cement Mortar 1:3 (1 Cement : 3 coarse sand) but excluding reinforcement.
Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete: 3.12.2) Thermo-Mechanically treated bars FE 500D
Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work.
Making 50mm thick plinth protection of plain cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with sand including finishing the top smooth.
Providing and fixing in expansion joint pre moulded cross linked polymer based filler as per IS:1838 (part III) of approved make including cutting to required size and shape etc complete. 3.23.3) 50 mm thick
Providing and applying for hermetically water proof sealing of vertical / horizontal expansion joint with approved make Poly Sulphide Sealant compound (two component elastomeric sealant) having 80% tensile modulus elongation, proper bonding with building surface complete with cleaning and preparing of building surface, applying polymer solvent primer, providing and fixing PU back up rod of suitable dia in expansion joint for core making, filling with Poly Sulphide Sealant (Sealant filling depth should be minimum half of the joint gap), finishing and smoothing the surface etc complete. The application shall be got done through the authorised applicator of the manufacture of compound 3.24.3) For gap 50 mm wide
Providing and fixing aluminium strip 1.60 mm thick on expansion joints with iron screws as per design to match the colour, shade of wall treatment .
Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: 2.1.1) Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
Columns, Pillars, Piers and likes- rectangular or square in shape
Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)
Beams, lintels, cantilevers & walls
Window sills, anchor blocks, string course, bends, copings, bed plates and like.
Weather shade, chhajja, Cornices and mouldings
Wall of any thickness including attached pilasters, buttresses etc. in super structure.
Stair cases of all types excluding spiral and folded plate type, including risers and landings
Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M.
Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete.
Supplying chlorpyrifos/ Lindane emulsifiable concentrate of 20% in sealed containers including delivery as specified.
Diluting chemical emulsion (chlorpyrifos/ lindane) in water as per manufacturers recommendation and injecting for pre-constructional curative cum preventive anti-termite treatment:(Five year service guarantee bond to be signed by contractor) 1.25.1) Surface treatment by spreading emulsion under floor, over the plinth area before laying base concrete @ 5 litres / sqm
Treatment of inside of plinth masonry wall on using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall below plinth protection at the interval of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand).
Treatment of outer side of plinth masonry wall using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall at the junction of floor at the interval of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand).
Carriage by mechanical transport upto 5 km lead: 1.26.1) Earth
Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: 7.5.4) Cement Mortar 1:6 (1 cement : 6 coarse sand)
Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level. 7.11.2) Cement Mortar 1:4 (1 cement : 4 coarse sand)
Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level:
Extra for providing and placing in position hopping 25x1.60 mm or 2 Nos 6mm dia MS bars reinforcement at every third course of half brick masonry.
Providing and laying LIGHT WEIGHT CELLULAR CONCREAT block in block masonary of width 100/200 mm height 200/250/300 mm, length 400/500/600 mm (approved size) with cement mortar 1:6 (1 cement:6 course sand ) in superstructure.Block should have specific gravity 0.8 to 065 and crushing strength should not less than 3 N/Sqmm. (testing as per IS: 6441-1972)
Providing and making 6mm thick cement plaster of mix: 11.1.2) In Cement mortar 1:4 (1 cement : 4 fine sand)
Providing and making 12mm thick cement plaster of mix: 11.2.3) In Cement Mortar 1:5 (1 cement : 5 fine sand)
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: 11.3.3) In Cement Mortar 1:5 (1 cement : 5 fine sand)
Neat Cement punning.
Providing and making 18 mm thick cement plaster with under layer of 12mm thick cement plaster 1:5 (1 cement : 5 fine sand) finished with a top layer of 6mm thick cement plaster 1:3 (1 cement : 3 fine sand).
Providing and making pointing on brick work with cement Mortar 1:3 (1 cement : 3 fine sand) 11.37.3) Cut off weather struck pointing
Providing and making 18 mm thick plain cement mortar band in cement mortar 1:4 (1 cement : 4 fine sand) per cm width: 11.32.4) Drip course
Providing and applying 2mm thick white cement based polymeric Exterior grade Putty with minimum 3 coats applied @ 5.4 kg/ 10Sqm as per relevant IS code 17545:2021 (Product such as Birla wall care, Asian trucare,JK wall putty, Berger Bison wall putty) to make the surface smooth and even with all tools tackles and labour etc. complete for the work.
Providing and applying Polymaric cement primer on all surface applied @ 0.80 litrs/10 sqm as per relevant I.S. code 15489:1974 (product such as Birla white primacoat/activcoat, Asian Trucare , Dulux interior cement primer, Opus Calista / I10 ) with all tool tackles and labour etc. complete for the work .
Providing and applying Synthatic oil bound washable Distemper having VOC content less than 50gms/ lit. Minimum two coats up to final finish to give an even shade applied 1.25 kg / 10Sqm as per relevant I.S. Code 428:2000 (product such as Asian Tractor synthatic distemper , Berger Bison Lite , Dulux Magik , Birla Opus Style super smart) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work.
Providing and applying exterior surface with PREMIUM HEAVY DUTY Glossy or Matt Finish Exterior Emulsion paint of required shade to give protective and water proof finish minimum three coats applied @ 1.43 lit / 10Sqm up to final finish as per relevant I.S. Code 15489:2013 Type -2 Class D , C , B & A ( Glossy / matt / Egg Shell finish )having high DFT and silicon aditive for elastomaric property (Product such as Asian Ultima ,Dulux Weathershield Maxx , Berger Weathercoat All Guard , Nerolac Excel Total , Nippon Durafresh Expert , Opus Tru Look) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work. (With 4 Year Warranty)
Boring, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in cement concrete 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size), to carry a safe working load, excluding the cost of steel reinforcement but including the cost of boring with auger by manual means and making one bulb using suitable bulb enlarging tool by MANUAL MEANS with all instruments and arrangements required for boring true to vertical line etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap): 15.5.2) 300 mm dia piles
Providing and fixing in position impregnated fibre board confirming to IS: 1838 in expansion joints, including cost of primer, sealing compound all complete. 3.21.2) 25mm thick
Providing and placing in position angle iron post and strut of required size including bottom to be split and bent at right angle in opposite direction for required length and drilling holes upto 10 mm dia as per requirement including priming coat with red oxide zinc chromate primer and placing the post/ strut in cement concrete block.
Providing and fixing concertina coil fencing with required dia 610 mm (having 50 nos. round per 6 metre length) up to 3m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 m apart tied with G.I. staples and G.I. clips to retain horizontal including necessary bolts or G.I. barbed wire tied to angle iron all complete as per direction of Engineer-in-charge with reinforced barbed tape (R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
Steel work in tubular (round, square or rectangular hollow tubes etc.) structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer. 9.3.2) Electric resistance or induction butt welded tubes Grade-300
Providing and applying Glossy finish Enamel paint mimimum 2 coats in all surface applying @ 0.75 lit/ 10 Sqm up to required finish as per relevent I.S. code 2932: 2013 of (Product such as Asian Apcolite Premium Enamel , Dulux Promise Premium Enamel , Nerolac Synthatic Enamel, Opus Prime enamel ) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackle and labour etc. complete for the work.
Cement art Mural work
Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position. 8.1.2) Sal, bijasal, benteak, khair, haldu
Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges. 8.12.2) 35 mm. thick (single leaf)
40 mm. thick (single leaf)
30 mm. thick (single leaf)
Providing 40x5mm iron hold fast 40cm long including fixing to frame with 10mm bolts nuts and wooden plug and embedding in Cement Concrete 1:2:4 in blocks of size 30x10x15cm.
Providing and fixing bright finished brass butt hinges with brass polished MS screws complete: 8.58.1) 125x85x5.50 mm (Heavy Type)
Providing and fixing bright finished brass sliding door bolt with nuts and brass polished MS screws complete: 8.60.1) 300x16mm
Providing and fixing brass door latch with brass polished MS screws complete: 8.61.2) 250x16x5 mm
Providing and fixing bright finished brass tower bolts (barrel type) with brass polished MS screws complete: 8.62.3) 150x10mm
Providing and fixing commercial grade water proof ply for wall paneling on wooden frame with necessary nails complete as required. 8.36.1) 19mm
Providing and fixing approved shade veneering on wood wall paneling complete as required.
Providing and fixing bright finished brass door handles with brass polished MS screws complete: 8.65.1) 125 mm
Providing and fixing bright finished brass hanging door stopper with necessary brass finished MS steel screws complete.
Extra for double leaf shutter instead of single leaf.
Providing & fixing 150mm antique/ SS finished brass floor door stopper with rubber cushion and antique/ SS polished MS screw complete to suit the shutter thickness.
Providing and fixing powder coated aluminium sliding door bolts with 16mm rod, necessary M.S. nuts bolts and screws etc complete. 8.126.1) 300x16mm
Providing and fixing powder coated aluminium tower bolts (Barrel type) with necessary M.S. screws etc complete. 8.128.1) 250 x10mm
Providing and fixing powder coated aluminium door handles 2.5mm thick with necessary M.S. screws etc complete. 8.129.1) 150 mm
Providing and fixing powder coated aluminium door mounted door stopper with necessary M.S. screws etc complete. 8.132.5) 100 mm long
Providing and fixing stainless steel butt hinges IS : 12817 marked with necessary stainless steel screws etc complete. 8.149.2) 125x1.9mm (light)
Providing and fixing 150mm bright finished brass floor door stopper with rubber cushion & brass polished MS screws etc complete to suit the shutter thickness.
Providing and fixing IS: 3564 marked aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc complete.
Providing and fixing Dash fastener (for fixing door/ window frames) on C.C. / R.C.C./ Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. 8.4.3) Dash fastener 12x100mm
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50m in height dimension comprising of uPVC multi-chambered frame with in- built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazed beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc/alloy body with single nylon rollers (weight bearing capacity to be 40Kg,)G.I. fasteners 100 x 8mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage o water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weater proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-charge .(Single/double glass panes, wire mesh and sillicon sealent shall be paid separately vide chapter no. 9.51,9.58,9.59 Respectively) Note : For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. 8.166.D.2) Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2mm and single glazed bead of appropriate dimension. (Area of window above 1.75 sqm)
Providing and fixing factory made uPVC white colour fixed glazed window/ventilators comprising of uPVC multi- chambered frame and mullion(where ever required) extruded profile duly reinforced with 1.60 ± 0.2mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile).uPVC extruded glazing beads of appropriate dimension,EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitredcut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer- in - Charge.( Single/double glass panes and silicon sealant shall be paid separately vide chapter no. 9.51, 9.58,9.59 Respectively) Note : For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. 8.164.B.1) Fixed window/ventilatormade of (smallseries) frame 47 x 50mm & mullion 47 x68 mm both having wall thickness of 1.9 ± 0.2mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm)
Providing and fixing factory made uPVC white colour casement/Casement fixed glazed door comprising of uPVC multichambered frame, sash and mullion(where ever required) extruded profiles duly reinforced with 1.6 ± 0.2mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile, uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key,G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holesfor fixing hardware's and drainage of water etc.After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-charge.(Single/Double glass panes and silicon sealent shall be paid separately vide chapter no. 9.51,9.58,9.59 Respectively). Note: For uPVC frame, sash and mullion extructed profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. 8.165.C.2) Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9mm) made of (big series) frame 67 x 64mm,sash 67 x 110mm & mullion 67 x 80mm all having wall thickness of 2.3 ± 0.2mm and single glazing bead/double glazing bead of appropriate dimension. (Area of door upto 2.50 sqm)
Providing and fixing casement handle made of zinc alloy ed ( white powder coated) for uPVC casement window with necessary screws etc. complete
Providing and fixing zinc alloyed (white powder coated) touch lock for uPVC sliding window with necessary screws etc. complete
Providing and fixing steel roller for uPVC sliding door with necessary screws etc.complete
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer. 9.6.2) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.
Providing and fixing concertina coil fencing with required dia 610 mm (having 50 nos. round per 6 metre length) up to 3m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 m apart tied with G.I. staples and G.I. clips to retain horizontal including necessary bolts or G.I. barbed wire tied to angle iron all complete as per direction of Engineer-in-charge with reinforced barbed tape (R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
Providing and fixing in position chain linked steel wire fabric made of 4 mm dia G.I. wire of required width in mesh to concrete/ wooden/ angle iron posts including securing and screwing with 2mm dia G.I. wire, G.I. staples, G.I.U-nails or steel pins etc., complete. 9.43.1) Aperture 50x50mm
Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately: 9.47.1) For fixed portion
For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/neoprene gasket required (Fittings shall be paid for separately).
Extra for powder coated (minimum 50 micron) aluminium sections instead of anodized.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item): 9.51.6) With float TOUGHENED glass of 5mm thickness
Providing and fixing stainless wire gauge of average width of aperture 1.56mm with wire of 0.35mm to existing steel door, window shutter frames with necessary M.S. strip beading etc. complete.
Providing stainless steel railing/ grill made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design fixing in stair case, balcony or other places with metal fasteners and stainless steel bolts etc complete. 9.57.2) SS Grade 304
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rails of T-iron 40x40x6mm with 38mm steel pulleys complete with bolts, nuts, locking arrangement stoppers, handles including applying a priming coat of red oxide zinc chromate primer.
Providing and fixing Special Designer glass film over glazed doors,windows & partition etc. complete
Providing and fixing clear float toughened glass door or partition in required thickness frameless in appropriated size inclusive of edge molding polish and making required size slot or hole for patch fitting/hardware etc. The glass to be assembled together with patch fitting and hardware in proper alignment with all labour tools and tackles etc. complete. (Patch fittings and hardware to be paid for separately) 9.63.2) 10mm thick for door/partition
Providing and fixing chicken mesh weighting not less than 250 gms/sqm as per IS : specification in the required width with 40mm long steel nails on vertical and horizontal surface near R.C.C. and brick walls junctions including scaffolding and all lead and lifts etc. complete before plastering upto 10mts in height.
Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement. 12.3.2) 50 mm thick
25mm wooden planking tongued and grooved in flooring including fixing with iron screws complete with: 12.68.1) Teak wood
38 mm thick parquet (wood blocks) flooring of teak wood laid over 25mm thick leveling layer of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm nominal size) to be paid separately coated with thin layer of hot bitumen (blown type) @ 2.45 kg/ sqm including fixing blocks after dipping in hot bitumen (blown type) upto half depth planned, leveled, smooth and finished complete.
Providing & laying 60mm thick precast interlocking concrete blocks of approved size (approx 305 sqcm) and shape/ pattern, over 40 mm thick average complete coarse sand bed with joints of 3mm thick filled by fine sand including leveling with surface vibrator, temping and sweeping etc. complete of minimum compressive strength of 250 kg/sq.cm 12.65.2) Pigment Coloured (rubber mould) precast interlock concrete blocks
Extra for plaining the lower surface of wooden planking
Providing and fixing in position homogeneous P.V.C. quartz reinforced floor covering tiles conforming to I.S. 3462/1986 of size 300x300 mm over existing smooth and finished surface including removal of dust etc. from existing floor and laying approved adhesive (Dunlop S- 758, Fevicol SR 998 or equivalent) at the rate of 0.25 kg/ sqm including rolling with light wooden roller weighing about 5 kg etc. complete. 12.72.3) 3 mm thick tiles (Weight 6 kg per sqm)
Providing and Fixing rectified glazed ceramic floor tiles of 1st quality conforming to IS: 15622-2017 of approved make,in all colours shade over 20mm thick bed of cement mortar 1:3 (1 cement:3 course sand) and joining with grey cement slurry @ 3.3kg per sqm. including pointing in white cement mixed with matching pigment complete. 12.74.2) Size 400x400 mm thickness 7 to 8 mm
Size 600x600 mm thickness 8 to 9 mm
Providing and Fixing rectified glazed ceramic wall/dado tiles of 1st quality conforming to IS: 15622-2017 of approved make,in all colours shade in wall and dado over 12mm thick bed of cement mortar 1:3 (1 cement:3 course sand) and joining with grey cement slurry @ 3.3kg per sqm. including pointing in white cement mixed with matching pigment complete. 12.75.3) Size 400x800 mm thickness 7 to 9 mm
Size 300x600 mm thickness 7 to 8 mm
Providing and laying Matt/Glazed finish HOMOGENOUS ACROSS FULL BODY VITRIFIED floor tiles(heavy duty) with water absorption less than 0.05% and conforming to IS: 15622-2017 of 1st quality of approved make in all colours,shade and size mensioned below(+/- 10mm),laid on 20mm thick cement mortar 1:4 (1cement:4 course sand) including grouting th ejoints with white cement and matching pigments etc. complete. 12.78.1) Size 600x600 mm thickness 9 to 10 mm
Size 1000x1000 mm thickness 10 to 12 mm
Providing and laying DOUBLE/MULTI CHARGE (minimum 2.0mm thick layer) VITRIFIED floor tiles(heavy duty) with water absorption less than 0.05% and conforming to IS: 15622-2017 of 1st quality of approved make in all colours,shade and size mensioned below(+/- 10mm),laid on 20mm thick cement mortar 1:4 (1cement:4 course sand) including grouting th ejoints with white cement and matching pigments etc. complete. 12.79.4) Size 1200x1200 mm thickness 10 to 12 mm
15 mm thick Table rubbed polished Granite stone slab in risers and treads of steps skirting dado and pillars laid on 12mm (Average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing etc. complete (single stone is to be used for risers and treads of steps and width of stone for skirting and dado shall be equal to the height of skirting & dado and length of 1.0 m). 12.46.1) Granite stone grey/pink
Granite stone black
Granite stone lakha red/ shahi red
Extra for nosing in Granite stone for treads.
15 mm thick Table rubbed polished Granite stone slab flooring laid over 20mm (Average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing etc. complete. (Area of slab should be 0.50 sqm and above) 12.45.1) Granite stone grey/pink
Granite stone black
Granite stone lakha red/ shahi red
15mm thick Granite work (machine cut, table rubbed & mirror polished) for kitchen platform, vanity counters, window sills and similar locations of required size laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) including joints treated with white cement mixed with matching pigment including rubbing and polishing to edge moulding to give high gloss finish. 13.6.2) Granite stone black
Granite stone lakha red/ shahi red
Extra for providing edge moulding to 15mm thick stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Providing and fixing one side polished 25 mm thick RAJIM SAND STONE shelves fixed in walls in cement mortar 1:3 (1 cement : 3 coarse sand) including finishing complete. 13.24.1) One side polished
Both side polished
15mm thick Granite work (machine cut, table rubbed & mirror polished) for wall lining (veneer work) in cement mortar 1:3 (1 cement : 3 coarse sand) including pointing with cement mortar 1:2 (1 white cement: 2 marble dust) mixed with matching pigment. (Area of slab should be over 0.5 sqm). 13.4.2) Granite stone black
Supply and fixing of polymer precoated galvalume profile sheets (PPGL) of approved size, shape and pitch of corrugation, total coated thickness (TCT) 0.60 mm +/- 5%, epoxy primer on both side of the sheet and colour polyester top coat 18-20 microns and 6-7 microns on bottom. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : 10.16.1) Ridges plain (500-600mm)
Gutter. (600 mm over all girth).
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down grade) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx650 micron thick (0.65mm), finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete.
Providing and applying 2mm thick white cement based Acrylic grade putty with minimum 3 coats applied @ 4.0 kg/ 10Sqm as per relevant IS code 17545:2021 (Product such as Asian trucare, Berger Happy walls Putty , Birla Opus One pro smooth) to make the surface smooth and even with all tools tackles and labour etc. complete for the work . (This Item to be use in heigher grade painting works Item No. 14.65)
Providing and applying Premium plastic emulsion paint with roller application minimum three coats applied @ 0.75 lit / 10Sqm up to final finish as per relevant I.S. Code 15489:2013 Type -1 Class D & C ( Glossy and Semi Glossy Finish) of required shade (Product such as Asian Apcolite Premium , Dulux Super Cover, Berger Easy Clean ,Nippon Breezee Metex Gold, Opus I-50 / Calista) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work.(with 3 year Warranty)
Providing and applying on exterior surface with PREMIUM Exterior emulsion paint of required shade to give protective and water proof finish minimum 3 coats applied @ 1.40 lit / 10Sqm up to final finish as per relevant I.S. Code 15489:2013 Type -2 Class D , C (Glossy /Semi Glossy finish ) (Product such as Asian Apex ,Dulux Weather Shield Prima E900 , Berger Weathercoat Antidust , Nerolac Everlas Excel , Nippon Sumo Etra, Opus True flex) inclusive of providing abro tape on edges and articleand cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work.(With 3Year Warranty.)
Providing and applying Glossy finish Enamel paint mimimum 2 coats in all surface applying @ 0.75 lit/ 10 Sqm up to required finish as per relevent I.S. code 2932: 2013 of (Product such as Asian Apcolite Premium Enamel , Dulux Promise Premium Enamel , Nerolac Synthatic Enamel, Opus Prime enamel ) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackle and labour etc. complete for the work.
Providing and applying Aluminium paint mimimum 2 coats in all metal surface applying @ 0.75 lit/ 10 Sqm up to required finish as per relevent I.S. code 2932: 2013 of (Product such as Asian Apcolite aluminium paint, Dulux Aliminium paint, Burger Superior Aluminium Paint) with all tools tackle and labour etc. complete for the work.
Providing and laying integral cement based water proofing treatment on roofs, balconies, terraces etc with average thickness of 120mm and minimum thickness at khurra as 65 mm, consisting of following operations including surface preparation: i) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement mixed with water proofing compound conforming to IS. 2645 over the RCC slab including adjoining walls upto 300mm height. ii) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) mixed with water proofing compound conforming to IS : 2645 over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) mixed with water proofing compound conforming to IS : 2645 to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. iii) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645. iv) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) mixed with water proofing compound conforming to IS : 2645 including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. v) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order:
Providing and laying water proofing treatment in sunken portion of WCs, bathroom, kitchen etc., by applying cement slurry mixed with water proofing cement compound consisting of following applications including surface preparation: i) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. ii) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound@ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Grading roof for water proofing treatment with:Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing and applying Polishing in high gloss/matt finish MELAMINE CLEAR POLISH on wood work in required color/wooden shade texture with following process in the sequence as detailed below:1.The surface to be polished is rubbed with sand paper 80/120 no. & then with sand paper of 160/180 nos.2.Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3.On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing,then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4.On this, 1st coat of melamine polish is applied with spray gun using melamine clear polishand melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs.The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. Final coat to be done in 2 layers without gap of time. inclusive of providing abro tape on edges and article and cleaning of adjucent surface with all tools, tackles and labour etc. complete for the work.
Providing and applying acrylic modified resin EXTERIOR TEXTURED with special quality silica quartz plaster as an intermediate coating on external surface giving protective layer and decorative finish on plastered surface in approved design and shade (product such as Asian Apex Series Duracast Dulux weathersheald sandtax creation) as per manufacturer's specifications inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour etc.complete for the work. 14.70.1) 2.0mm thickness (average) having design scratched with leveled & smooth surface.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 19.6.4) 32 mm nominal outer dia pipes
40 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 19.5.1) 15 mm nominal outer dia .Pipes.
20 mm nominal outer dia .Pipes.
25 mm nominal outer dia .Pipes.
Providing and laying in trenches G.I. pipes medium class complete with G.I. fittings including excavation of trenches, refilling the same and testing of joints complete: 19.9.1) 15 mm dia. nominal bore
32 mm dia. nominal bore
50 mm dia. nominal bore
Making connection of G.I. distribution branch in G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: (dia of main line to be measured) 19.10.2) 32 mm nominal bore
50 mm nominal bore
Providing and fixing gun metal non- return valve (vertical type) of approved quality (screwed end) : 19.19.4) 50 mm nominal bore
65 mm nominal bore
Providing and fixing 15 mm nominal bore Brass bib/stop cock of approved quality: 19.13.3) Stop cock (350 grams)
Cutting holes upto 30x30 cm in walls including making good the same :
Cutting holes upto 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof.
Constructing masonry Chamber 30x30x50 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design :
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: 19.14.1) Bib cock (400 grams)
Long body bib cock (500 grams)
Piller Cock (400 grams)
Two way bib cock (800 grams)
Stop cock (concealed) (600 grams)
Toilet paper holder
Soap dish plate
Towel rail (600mm long x 20mm dia)
Bottle trap set with extension pipes
Health foscet (hand jet) with flexible connection pipe (for WC)
Providing and fixing stainless steel drain jali of approved make/quality.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 18.30.1) 5mm thick Mirror
Providing and fixing vitreous china water closet (European type W.C. pan) with white ISI marked plastic seat and lid, 10 litre low level white P.V.C. flushing cistern (same colour), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : 18.4.3) White wall hung type
Providing and fixing white vitreous china urinal basin with waste fitting as per IS : 2556, and other couplings in C.P. brass complete: 18.13.1) Flat back half stall urinal of size 460x380x250mm
Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : 18.17.5) White Oval or round size 550x400mm.
Providing and fixing stainless steel AISI-304(18/8) wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : 18.20.2) Size 510x410 mm
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 18.25.2) 40 mm dia
Providing and fixing PVC waste coupling in wash basin/ sink. 18.26.2) 40 mm
Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. 18.76.1) 75 mm dia pipe.
110 mm dia pipe.
150 mm dia pipe.
Extra for making opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including making necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete.
Providing and fixing 15mm thick Granite (machine cut, table rubbed & mirror polished on both sides) for partition curtain in toilets or similar locations of required size in wall with cement mortar 1:4 (1 cement : 4 coarse sand) including cutting chase in wall and joint with wall treated with white cement mixed with matching pigment including rubbing and polishing to edge moulding to give high gloss finish. 13.17.2) Granite stone black
15mm thick Granite work (machine cut, table rubbed & mirror polished) for kitchen platform, vanity counters, window sills and similar locations of required size laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) including joints treated with white cement mixed with matching pigment including rubbing and polishing to edge moulding to give high gloss finish. 13.6.2) Granite stone black
Providing and fixing one side polished 25 mm thick RAJIM SAND STONE shelves fixed in walls in cement mortar 1:3 (1 cement : 3 coarse sand) including finishing complete. 13.24.1) One side polished
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 18.77.1) Tee/ Tee with door/ Bend 45°/ Bend 90° 18.77.1.1) 75 mm
Double "Y" with or without door 18.77.2.1) 75 mm
Vent covel 18.77.3.1) 75 mm
Access door cap 18.77.4.1) 75 mm
"P" trap 110mmx110mm long
Nahani trap 110x75mm
Providing and fixing UV stabilized Unplasticised -PVC pipe clips of approved design to Rigid PVC pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 18.78.1) 75 mm
Providing and fixing square-mouth S.W. gully trap grade 'A'’ complete with C.I. grating brick masonry chamber with well burnt modular clay bricks crushing strength not less than 35kg/cm2, water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 20.3.3) 180x150 mm size P type
Constructing brick masonry manhole with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 ( 1 cement : 4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation in cement concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : 20.7.4) Inside size 90x80 cm and 45 cm deep including RCC cover with frame 450x600 mm internal dimensions.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Providing and fixing at all height false ceiling consisting of frame work "W" / "U" / "L" sections made of G.I. sheet with zinc coating of grade 120 consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick button wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.55mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed including providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS: 2095- Part-I all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting.
Extra for sunk or raised mouldings in the Gypsum board/ plaster of paris false ceiling.
Providing and fixing 2mm thick semi transparent polycarbonate profile roofing sheet of approved make and colour to make any normal roofing / covering and fixing as per manufacture specification at spacing not more than 1.2 m centre to centre with EPDM gasket and silicon sealant fixed with self drilling stainless steel screws all complete as per direction of Engineer-in-Charge.
Providing and Fixing false ceiling at all heights with 15 mm thick integral densified tegular edged light weight calcium silicate false ceiling tile reinforced with fibre and natural fibre false ceiling tiles of size 595x595 mm of approved texture,deesign and patterns (sach as cosmos spinton quatra golb) having NRC (Noice Reduction Coefficient) of 0.50 minimum as per IS: 8225-1987,Light reflectance of 85% minimum.Non combustible as per BS:476 (part-4),fibre performance as per BS:476 (part-6 & 7),humidity resistance of 100% thermal conductivity 0.148 to 0.050 w/m0KC as per ASTM :518-1991,weight 1.9 kg to 2.1 kg per tile 15 mm edge density having 450 kg/cum & 10 mm central portion of tile having 350 kg/cum in true horizontal level suspended on inter locking metal powder coated T-Grid of hot dipped galvanised iron sections of 0.40 mm thick on Silhouette Grid rotary stiched double webed white with 6 mm reveal profile (white/black) comprising of Main 'T' runner of size 15x42 mm of length 300 mm,cross-T of size 15x42 mm of length 1200 mm and secondary intermadiate cross-T of size 15x42 mm of length 600 mm to form grid module of size 600x600 mm,suspended from ceiling using galvanised mild steel items (galvanised @ 80 grams per sqm.) ie. 40 mm long,8 mm outer dia. M-6 dash fasteners,6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm.Galvanise iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm. to be fixed on periphery wall/parttion with the help of rawl plugs at 450 mm center to center and 40 mm long dry wall ss scews.The work shall be carried out as per specifications,drawing and as per direction of the Engineer-in Charge.Ceiling height up 3.5mt. from adjcent floor level..Extra height to be paid separately.
Providing and fixing of aluminium tile false ceiling comprising of Tile of size 600 x 600mm x 0.7mm. The Tile ends will be raised with pips and stops to ensure positive engagement into the spring to enable for de-mounting of individual panels. The Tile sides will be sufficiently high to ensure a minimum deflection across the length of Tile. All Tiles will be bevel edged. The Tile shall be powder coated. The Tile shall be clipped into clip-in profile made of 0.5mm thick G.I sheet. The clip-in profile shall be supported from slab by means hold on clamp with clip and 4mm dia G.I. rod fixed to ceiling rigidly. Wall trim box of size 15x30x15mm made from 0.4mm thick aluminium alloy sheet to be provided all along the wall to hold panels (only surface area of false ceiling is to be measured and no deductions for lights, diffusers, columns etc shall be made) 10.65.2) With perforated tiles having perforation with 2.5mm dia and 5mm center to center and pasted with non woven tissue on the back side
Providing and fixing wall paneling frame made of commercial grade 12mm thick water proof ply strips 100mm wide at 600mm apart center to center vertically and horizontally with necessary screws, wooden plugs etc complete as required.
Supplying and stacking of good earth at site including royalty, loading, unloading and carriage upto 10 km (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking sludge at site including royalty, loading, unloading and carriage upto 10 km (sludge measured in stacks will be reduced by 8% for payment).
Supplying and stacking at site well decayed cow dung manure from approved source, including loading, unloading and carriage upto 5 km (manure measured in stacks will be reduced by 8% for payment).
Spreading of sludge, dump manure or/and good earth in required thickness (Cost of sludge, dump manure or/ and good earth to be paid separately).
Mixing earth and sludge or manure in proportion specified or directed.
Rough dressing the trenched ground including breaking clods.
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation.
Fine dressing the ground
Edging with modular well burnt clay bricks of crushing strength not less than 25kg/ sqcm laid dry length wise including excavation, refilling, consolidating with hand packing and spreading neatly surplus earth within a lead of 50 m :
Providing and planting following herbs in garden including preparation of soil, base plantation, providing and spreading different fertilizers, soil and sand: 22.25.1) Hedges like Alife, Dorenta, Tikoma etc
Furn like Arica, China etc (3 year old)
Hibiscus (Flower)/ Rose
Carpet grass
Providing and fixing M.S. flat iron tree guard 60cm dia. and 2m height above ground level formed of 4 nos. 25x6mm and 8 nos. 25x3mm vertical M.S. flats riveted to 3 nos. 25x6mm M.S. flat iron rings in two halves, bolted together with 8mm dia. and 30mm long bolts including painting two coats with paint of approved brand and manufacture over a coat of priming, complete in all respects.
Coursed rubble masonry (Second sort) with hard stone in Cement mortar 1:6 (1 cement : 6 coarse sand) upto plinth level.
Extra for coursed rubble masonry with hard stone (Second Sort) curved on plan for a mean radius not exceeding 6.0m
Providing and fixing PVC panels false ceiling of approved colour,Texture and size of panels 300mm wide X 3500mm long. The panels are light weight,termite,rust proof and anti bacterial in nature and also water proof, fire retardent and maintence free in nature. but excluding the cost of frame.
Providing and fixing Glass Reinforced Concrete (G.R.C) screens in approved size, pattern, design, thickness and approved color from f M/S UniStone or equivalent approved. The screens should be made from '53 grade Cement manufactured by 'JK Cement or equivalent, Fine graded Quartz & Silica Sand, Alkali Resistant Glass Fiber manufactured by M.E.G. JAPAN' or equivalent, Super Plasticizers manufactured by 'BASF or equivalent, Polymers manufactured by 'BASF or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by BAYFERROX (Germany)' or equivalent. The material casting should take place in FRP Mould or equivalent. The fixing of Screens should be done with 'Dry Fixing methodology i.e. to be done with M.S. Galvanized 'L' shaped Clamps, dash fasteners and pins, as per approved shop drawings from Engineers in charge. Rates are inclusive of all the operations described above for all heights and leads including all scaffolding, staging. T&P and sundries eic.
Providing & laying Monier Concrete Roof Tiles fitting accessories. Monier Ridge Tile
Providing & laying Monier Concrete Roof Tiles fitting accessories. HIP STARTER RED
Providing & laying Monier Concrete Roof Tiles fitting accessories. 4 WAY RED
Providing & laying Monier Concrete Roof Tiles fitting accessories. TILE CLIP
Providing & laying Monier Concrete Roof Tiles fitting accessories. TOP FLEX RED TAPE
For Roof With Land Scaping /Terrace Garden Treatment :Providing and applying Solvent free two component Polyurethane spray applied waterproofing system (manufactured by BASF India ltd or equivalent product from Fosroc chemicals India pvt.Ltd MYK Schomborg or Ardex endura India Pvt.Ltd) on Landscape on horizontal and vertical face at 2 mm total thickness .i/c applying moisture insensitive epoxy primer broadcasting with sand after necessary surface preparation following by applying waterproofing membrane specification . The mixed product should have 100% solid content as per din 53213, density of 0.9-1.0g/cm3 ,tensile strength of 8-10 Mpa as per DIN 53504, fast setting less than 1 min and green certified
Anti Root Barrier: Providing and laying anti root barrier membrane of M/s E.I. Dupont (India0 pv.ltd., Master Seal 975 From BSF,OR equivalent approved to the location as shown in the drawings or as directed complete all as per manufactures specification. Root Barrier Shall be consisting of green colored Elvalloy polymer layer of approx /25 GSM ,fused onto Typar non woven polypropylene geotextile layer of 300 GSM, so that the total weight of the membrane is approx .325 GSM with nominal thickness of 0.8 mm. The membrane shall be loosely laid over the surface with an overlap of 50 mm between the adjoining rolls.
For terrace over pre layed PUF insulation : (i) Providing and laying roof insulation with 60 mm thick impervious sprayed closed cell free Rigid Polyurethane foam over deck insulation conforming to IS -12432 Pt. III (density of foam being 40-45 kg/Cum), over a coat of polyurethane primer applied @ 6-8 sqm per litre,Waterproofing shall be spray applied directly above PUF insulation (as per specification, payable extra ) protection of waterproofing shall be done using 400 G polythene sheet and providing a wearing course with average 75 mm thick cement screed 1:2:4 (1 cement : 2 coarse sand : 4stone aggregate 20 mm nominal size ) in chequered rough finish, in panels of 2.5 mx 2.5m and embedding with 24G wire netting and sealing the joints with polymerized mastic ,all compete as per direction of Engineer-in- charge
(ii) For the area covered by solar reflective tile: Providing and applying solvent free two component Polyurethane spray applied waterproofing system (manufactured by BASF India Ltd or equivalent product from Fosroc chemicals India Pvt.Ltd MYK Schomborg or Ardex endura India Pvt.Ltd) over insulation horizontal and vertical face at 1.8 mm average thickness using specialized 2 component spray machine as per manufacture specification BASF or equivalent . The mixed product should have 100 % solid content as per 8-10 Mpa as pr DIN 53504,fast setting less than 1 min and green certified .consumption :2.2-2.4 sqmt
For exposed area of walls (U.V. STABLE TOP COAT) Protection of exposed waterproofing membrance with 2K-PU top coat, high solids, pigmented, UV stable for roofing systems and smooth surfaces. Providing and applying of Masterscal TC269 which is a pigmented, low viscosity, two component polyurethane topcoat. It cures to a elastic tough, hard wearing, glossing finish used over as top coat on Masterseal M800 water proofing system, coverage appx0.15-.20 kg/sqm. (characterics : Elongation at break (after 14 days) DIN53504 - 165: Tensile strength (after 14 days) DIN53504 - 12: Tear resistance (after 14days) DIN53515 - 70 manufactured by BASF India Ltd or equivelent product from Fosroc chemicals India Pvt.Ltd MYK Schomborg or Ardex endura India Pvt.Ltd)
Providing and fixing Heat Resistant Terrace Tile (300mmx300mmx10mm) with SRI (solar refractive index )> 78, solar reflection> 0.70 and initial emittance >0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement :4 coarse sand) and Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling / grouting and finishing complete as per direction of Engineer-in-charge.
Providing & Fixing Hydrophilic base 100 mm wide, 5 mm thick fixed at place of Concrete Joints during the execution of work. The Hydrophilic base jointing (resweallable water bar) having a swelling capacity of 800%
Providing of Water Proffing Treatement During Concreting: - Integral water proofing compound confirm to IS 2645 : 2003 should be used @ 200 gram as per consumption of every 50kg bag of cement mentioning with the low water cement ratio. After Concreting: - Cementation grouting to be adopted to honey comb area and bottom most construction joint with cement slurry and non-shrink grout material mix and grout by low pressure grouting machine. All the construction joints and junction of pipe should be Fixed with Polyurethane base "fleece jointing" tape having elongation with 100% as well as 0% water permeable with appropriate adhesion material. Applying of 2 Coats of high flexible cementitious coating at a consumption of 2.5 kg / sq. mtr achieving minimum 01 mm at the inner side in all respect of wall and floor complete. The Product should be having highly flexible polymer modified cementitious coating with a crack bridging ability up-to 1.5 mm with a resistant of 7 water bar pressure and also having a elongation properties with 80%.
Providing and Fixing of Floor Inlet in pool tank made with ABS material in which colour witch has unique design permits 360° dispersion of fresh water in the pool, incl. flange, gaskets & S/S-screws. Internal Ø 50 mm & 50mm slip. The Suction head should have capacity of water flow 12.0 m³/h. it should be totally resistant against pool chemicals.
Providing and fixing 4 steps Pool Ladder as per standard design on tank wall made with S.S.-304 grade pipe of 43 mm dia, width 500 mm, steps distance 250 mm to be fixed with maintaining distance of 180 mm from pool wall and to be fixed with required self expanding fastener etc. complete.
Providing and fixing 5 steps Pool Ladder as per standard design on tank wall made with S.S.-304 grade pipe of 43 mm dia, width 500 mm, steps distance 250 mm to be fixed with maintaining distance of 180 mm from pool wall and to be fixed with required self expanding fastener etc. complete.
Providing and fixing Polypropylene grating at Dack level above over flow drain channel made with 35 x 295mm Polypropylene pieces will be jointed with push & fix arangment. (approx. 45 pieces per meter)
Providing and fixing Semi transparent polyethelene tank with external scale for checking tank capacity of 500 Ltrs.
Providing and installation of Agitators in the tanks which are having steering grip on Bakelite, 25 mm dia stirring rod minimum length 900 mm and PVC propellor arms etc complete.
Providing Moveable Suction swipping Trolley with 4 wheels of 6" dia.
P/F Suction Drain accessories with SS grill size 500mm x 500mm for water flow @ 100m3/hr at required place of pool tank.
Providing Aluminium Vacuum head for Heavy duty use; 19” wide; 38/50 mm connection weight: 4 kg Double Head 2 Fairlocks + connecting yoke.
Providing FLEXIBLE VACUUM HOSE dia 40mm and 30 M in Length Manufactured of UV resistant and long lasting plastics. (Supply should be Packing in tearproof PE bags.
Providing TELESCOPIC ALUMINIUM POLE 3.5 to 7.5 M Extenssion With functional excenter length adjustment, ergonomic soft hand grip. (Patented system for easy and quick assembly of the cleaning accessories)
Providing ALGAE BRUSH SS BRISTLES With stainless steel bristles SS-316 grade specially recommended for tile pools.
Providing CURVE BRUSH POLY BRISTLES With robust PPGF and UV resistant body.
Providing DEEP NET with reinforced and UV resistant PPGF frame and extra strong and finely woven extra deep net, with integrated dirt collection flaps and flat frame.
Providing TEST KIT TABLET TYPE Including 20 x PH/CL test tablets each, transparent tester with legible and reliable colour scale.
Providing & Filling Silica 0.5mm to 0.8mm made out of crushed marbal. Should be as per consultant & client engineer incharge approval.
Supply & installation with allied fittings of PVC 110mm dia pipe. Anti corrisive PVC pipe with resistant of working perssure not less then 10 Kg/ sqcm. Following IS 4985-2000.
Supply & installation with allied fittings of PVC 90 mm dia pipe. Anti corrisive PVC pipe with resistant of working perssure not less then 10 Kg/ sqcm. Following IS 4985-2000.
Supply & installation with allied fittings of PVC 50 mm dia pipe. Anti corrisive PVC pipe with resistant of working perssure not less then 10 Kg/ sqcm. Following IS 4985-2000.
Supply & Fixing with allied fittings of 110 mm dia NRV. Horizontal / Vertical NRV for floor drain in side drain chammber at floor of swimming pool at deep end. Anti corrisive PVC NRV. As per ASTM-D1784.
Supply & Fixing with allied fittings of 110 mm dia PVC butter fly valves in filtration room. As per ASTM-D1784
Supply & Fixing with allied fittings of 90 mm dia PVC butter fly valves in filtration room. As per ASTM-D1784
Supply & Fixing with allied fittings of 110 mm dia PVC Foot valves in Balancing Tank. As per ASTM-D1784
Providing and fixing Starting Blocks of size 500 x 500mm and height 700mm as per approved design made with S.S.-316 grade. The top surface of starting block should be polyester and fiberglass with non slip finish. Block to be fixed with self expanded fastener etc. complete.
Providing and fixing Float Line supplied with floats, 6 mm stainless steel cable and hooks ect. Complete. Floats length 50 M
Providing and fixing Float Line anchors made with S.S.-316 grade "S" Shape hook with spring etc complete.
Providing and fixing Float Line Flange anchoring Socket made with S.S.-316 grade fixed in wall of swimming pool with SS anchor bolts etc. complete.
Providing and fixing Float Line tensioner made with S.S-316 grade on either side of float lane
Providing and fixing False Start indicator post of 2 stainless steel post made with S.S.-316 grade 43 mm dia pipe and height 1.80 M one of them with pulley and quick cord fixing and loosening device.
Providing and fixing False start float rope polyester cord and float. (Float lenght 25 M)
Providing and fixing Level anchor fixing for 43 mm dia false start post made with S.S.-316 grade.
Providing and fixing Backstroke turn indicators post for indicating competition back stroke swimmers approximity of the end of the pool. comprising of 4 posts in stainless steel 43 mm dia and height 1.80 M made with S.S-316 grade
Providing and fixing Backstroke flage rope with 2 polyester cord and flage. (cord length 25m)
Providing and fixing Level anchor fixing for 43 mm dia back stroke indicator post made with S.S.-316 grade.
Providing of Safety polyethylene outer swim Lifebuoys ring dia 600 mm
Providing Lifeguard Loop, life saving hooks made of AISI-304 stainless steel to be used with telescopic handles.
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Short Point
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Medium Point
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Long Point
Wiring for twin control light point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)
Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Short Point
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Medium Point
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Long Point
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Extra Long Point I
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Extra Long Point II
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Extra Long Point III
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Short Point
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Medium Point
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Long Point
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Extra Long Point I
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Extra Long Point II
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Extra Long Point III
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 3 X 1.5 sq. mm in 20mm conduit
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 3 X 2.5 sq. mm in 20mm conduit
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 6 X 2.5 sq. mm in 25mm conduit
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 9 X 2.5 sq. mm in 32mm conduit
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 6 X 4 sq. mm in 32mm conduit
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 6 X 6 sq. mm in 32mm conduit
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 6 X 10 sq. mm in 40mm conduit
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 6 X 16 sq. mm in 50mm conduit
Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in concealed complete as per specification and IS: 9537 (2000 Part 5) 20 mm
Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in concealed complete as per specification and IS: 9537 (2000 Part 5) 25 mm
Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in concealed complete as per specification and IS: 9537 (2000 Part 5) 32 mm
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp piano type switch, phenolic laminated sheet, suitable size M.S. box etc as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Short Point
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp piano type switch, phenolic laminated sheet, suitable size M.S. box etc as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Medium Point
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp piano type switch, phenolic laminated sheet, suitable size M.S. box etc as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Long Point
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Short Point
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Medium Point
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Long Point
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Long Point
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Extra Long Point II
Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in surface complete as per specification and IS: 9537 (2000 Part 5) 20 mm
Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in surface complete as per specification and IS: 9537 (2000 Part 5) 25 mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi strand wire in the existing surface/ concealed, FRLS PVC conduit / PVC casing caping as per specification and IS: 694 (2010) 3 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi strand wire in the existing surface/ concealed, FRLS PVC conduit / PVC casing caping as per specification and IS: 694 (2010) 5 x 6 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi strand wire in the existing surface/ concealed, FRLS PVC conduit / PVC casing caping as per specification and IS: 694 (2010) 5 x 10 sq. mm
Supplying and drawing following pair 0.5 mm FR PVC insulated copper conductor, unarmored telephone wire in the existing surface/ concealed Steel/FRLS PVC conduit as per specification 2 Pair
Supplying and drawing following pair 0.5 mm FR PVC insulated copper conductor, unarmored telephone wire in the existing surface/ concealed Steel/FRLS PVC conduit as per specification 4 Pair
Supplying and drawing following grade co-axial TV wire FR PVC insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ concealed Steel/FRLS PVC conduit as per specification RG-6 grade
Supplying and drawing UTP 4 pair Cat 6 LAN wire in existing surface/ concealed Steel/FRLS PVC conduit as per specification and IS: 694 (2010)
Supplying and drawing following pair 0.5 mm FR PVC insulated stranded copper conductor armoured telephone wire in the existing surface/ concealed Steel/FRLS PVC conduit as per specification 10 Pair
Supplying and drawing following pair 0.5 mm FR PVC insulated stranded copper conductor armoured telephone wire in the existing surface/ concealed Steel/FRLS PVC conduit as per specification 20 Pair
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as per specification. 75mmX75mm (1/2 Module)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as per specification. 100mmX75mm (3 Module)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as per specification. 125mmX75mm (4 Module)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as per specification. 200mmX75mm (6 Module)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as per specification. 125mmX125mm (8 Module)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as per specification. 200mmX150mm (12 Module)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as per specification. 16 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as per specification. 2 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as per specification. 3 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as per specification. 4 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as per specification. 6 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as per specification. 8 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as per specification. 12 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as per specification. 16 Module
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. Bell push
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 3 pin 5/6 amp socket outlet
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. Fan regulator (two module size) electronic stepped type moving all rounds
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. RJ-45 {CAT6} socket outlet
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. RJ-45 {CAT6} LAN, I/O Box
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. Telephone socket outlet
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. T.V. antenna socket outlet
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. Computer Outlet Jack
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 25/32 amp A.C. Starter switch
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. USB charger socket 2.1 A
Providing and fixing composite unit for computer points having modular type 1 No 6 pin 16 amp socket outlet, 1 No 16 amp switch, 3 Nos 3 pin 6 amp socket outlets, 3 Nos 6 amp switches, suitable G.I. box, base and cover plates, earthing the sockets and switch box including etc. as per specification.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts A.C. supply, complete as per specification. Deluxe
Providing and fixing round/ hexagonal fan box (125mm dia) depth 75mm (max.) with 12mm dia steel bar hook, 1.6mm thick MS sheet cover, in RCC slab etc. as per specification.
Supplying, installation, testing and commissioning of following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, earthing etc. complete as required. P.F. should be greater than 0.9, with BEE Star rating from 3 star and above, IS: 374:2019 including all amendments. 1200 mm sweep
Supplying, installation, testing and commissioning of following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, earthing etc. complete as required. P.F. should be greater than 0.9, with BEE Star rating from 3 star and above, IS: 374:2019 including all amendments. 1400 mm sweep
Supplying, installation, testing and commissioning of premium quality Decorative ceiling fan having modern designer blades, good airthrow and with atleast two colour rendering effect along with unique smooth flowing canopies and down rod sleeve covering, wider blades at tips giving conical air throw including remote control for following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated , copper conductor, single core wire, earthing etc. complete as per specification. P.F. should be greater than 0.9, with BEE Star rating from 3 star and above, IS: 374:2019 including all amendments 1200 mm sweep
Supplying and fixing of wall/ cabin fan including connection etc. as per specification. P.F. should be greater than 0.9 300 mm sweep
Supplying and fixing of wall/ cabin fan including connection etc. as per specification. P.F. should be greater than 0.9 400 mm sweep
Supplying, installation, testing and commissioning of following sizes heavy duty (continuous running) 1400 rpm exhaust fan in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 300 mm sweep
Supplying, installation, testing and commissioning of following sizes heavy duty (continuous running) 1400 rpm exhaust fan in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 380 mm sweep
Supplying, installation, testing and commissioning of following sizes heavy duty (continuous running) 1400 rpm exhaust fan in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 450 mm sweep
Supplying, installation, testing and commissioning of following sizes fancy exhaust fan having built in louvers in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 225 mm sweep
Supplying, installation, testing and commissioning of following sizes fancy exhaust fan having built in louvers in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 300 mm sweep
Supplying and fixing following sizes of down rod of 15/20mm dia M.S. pipe of thickness 2 mm to ceiling fan including painting with matching colour etc. as per specification. 90 cm long
Supplying and fixing following sizes of down rod of 15/20mm dia M.S. pipe of thickness 2 mm to ceiling fan including painting with matching colour etc. as per specification. 120 cm long
Providing and fixing phenolic laminated sheet cover of 180 mm dia 3 mm thick on the fan box etc. as per specification. (If provided at the time of installation of ceiling fan)
Supplying, installation, testing and commissioning of following LED fitting (luminaries) Panel Light in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 9 Watt
Supplying, installation, testing and commissioning of following LED fitting (luminaries) Panel Light in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 12 Watt
Supplying, installation, testing and commissioning of following LED fitting (luminaries) Panel Light in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 15/16 Watt
Supplying, installation, testing and commissioning of following LED fitting (luminaries) Panel Light in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 18/20 Watt
Supplying, installation, testing and commissioning of following sleek LED panel down lighters (luminaries) in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 24 watt, size 300 x 300mm
Supplying, installation, testing and commissioning of following sleek LED panel down lighters (luminaries) in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 36 watt, size 600 x 600mm
Supplying, fixing, testing and commissioning of following LED lamps with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 9 Watt
Supplying, installation, testing and commissioning of following COB LED Spot Light fitting complete with Electronic Driver Heat sink Capacitor and all other accessories including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 9 watt
Supplying, installation, testing and commissioning of following COB LED Spot Light fitting complete with Electronic Driver Heat sink Capacitor and all other accessories including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 30 watt
Supplying, installation, testing and commissioning of following COB LED Spot Light fitting complete with Electronic Driver Heat sink Capacitor and all other accessories including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 40 watt
Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 10 watt {2 feet}
Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 18/20 watt {4 feet}
Supplying, installation, testing and commissioning of following 230/250 volts LED BOLLARD fitting cool white/warm white {Colour Temperature 3000/4000/5600/6000 K} with electronic driver, heat sink, capacitor and all other accessories on existing foundation/ pole bracket, including connection, earthing etc complete as per specification. P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 9 watt
Supplying, installation, testing and commissioning of following 230/250 volts LED Post Top Lantern fitting with perplex cover/decorative diffuser, electronic ballast and all other accessories on existing gate column/ pole bracket, including connection, earthing etc complete as per specification and P.F. should be greater than 0.9 . LED chip efficacy ratio ≥ 100 lumens /watt. 40 Watt
Supplying, installation, testing and commissioning of following LED Bulk Head fitting complete with Electronic Driver Heat sink Capacitor and all other accessories, including connection, earthing etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. IP65 10 watt
Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 60 watt
Supplying of following 230/250 volts LED Flood light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Seperate housing for driver etc complete as per specification and P.A. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 60 watt
Supplying of following 230/250 volts LED Flood light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Seperate housing for driver etc complete as per specification and P.A. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 80 watt
Supplying of following 230/250 volts LED Flood light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Seperate housing for driver etc complete as per specification and P.A. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 100 watt
Supplying of following 230/250 volts LED Flood light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Seperate housing for driver etc complete as per specification and P.A. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 120 watt
Providing and fixing wooden board of suitable size (18''x 24'') for energy meter etc complete as per specification. Solar Blinker/Signal light
Supply and installation of timer including relay and contactor set complete as required.
Supplying, installation, testing and commissioning of following 24 volts AC Supply LED under water light fitting for Swimming Pool with steel body with IP 68 protection including connection, earthing complete as per specification and P.F. should be greater than 0.9 (Excluding Driver) 24 watt RGB
Supplying , Installation, testing and commissioning of following type LED Driver for under water LED Lights having output 24 Volt AC, IP 66 by approved make as required. 30 watt
Supplying , installation , testing and commissioning for the following LED RGB / RGBW Linear wall washer luminaire for façade lighting with aluminium extruded housing of following wattage . Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX / Ethernet based control . The beam angle of the fitting shall be narrow , medium , wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any seperate power supply from 100 to 270 V AC , 50 Hz , power factor >0.9 . Fixture shall be suitable to operate at ambient temperature range of -10 Degree C to +50 Degree C and shall be IP 65 and IK 06 rated . Lifetime should be at atleast L70:50000 burning hours at 50 Degree C . Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables , water proof connectors etc as required. 55-60 Watt
Supplying, installation, testing and commissioning of Pulse with Module based water Proof controller for controlling RGB flood Light / Wall washer with remote control IP 65 as per the speciifcation.
Supplying, installation, testing and commissioning for the following LED RGB / RGBW flood lighting luminaire for façade lighting with Die-cast aluminium housing , power-coated finish of following wattage . Luminare shall be capable by DMX / Ethernet based control . The beam angle of the fitting shall be narrow , medium , wide , or asymmetric as per the requirement . Luminaire shall be complete with driver and capable of operating at line voltage without ant saperate power supply from 100-270 V AC , 50 HZ with power factor > 0.9 . Fixture shall be suitable to operate at an ambient temperature range of 10˚C to +50˚Cand shall be IP rated . Lifetime shall be atleast L70:50000 burning hours at 50˚C. Luminare shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables , water proof connectors etc as required. 150- 180 watt
Supplying, installation, testing and commissioning for the following LED RGB / RGBW flood lighting luminaire for façade lighting with Die-cast aluminium housing , power-coated finish of following wattage . Luminare shall be capable by DMX / Ethernet based control . The beam angle of the fitting shall be narrow , medium , wide , or asymmetric as per the requirement . Luminaire shall be complete with driver and capable of operating at line voltage without ant saperate power supply from 100-270 V AC , 50 HZ with power factor > 0.9 . Fixture shall be suitable to operate at an ambient temperature range of 10˚C to +50˚Cand shall be IP rated . Lifetime shall be atleast L70:50000 burning hours at 50˚C. Luminare shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables , water proof connectors etc as required. 240- 300 watt
Supplying, installation, testing and commissioning of following LED Strip Light fitting complete with Electronic Driver Heat sink Capacitor and all other accessories, including connection, earthing etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. IP-65 14 Watt per Metre RGB Coloured
Supplying , installation ,testing and commissioning of splitter and booster ,should be able to provide multiple output DMX/RDM splitter with DMX/RDM pass-through supporting bi-directional communications for discovery, addressing and DMX control of Ethernet/DMX . The output terminals should be electronically isolated from the input & RDM-through port and share a common ground reference. All six output ports should have an independent output driver to boost the DMX/RDM signal ,it should be with surface or DIN-rail mountable,Isolated DMX/RDM Input/Outputs,Automatic switching between DMX and RDM mode for auto-discovery including all accessories support etc as required with water proof M.S. Sheet panel of suitable size.
Supplying , installation , testing and commissioning of Multi Protocol converter,of protocol conversions, including Ethernet lighting protocol to DMX512,DMX512 to Ethernet and RS232 to Ethernet suitable for Wall-mounted ,convert DMX-based power / data supplies with any Ethernet-based device protocol converter works with the PoE-compliant switch or PoE injector Protocol Converter standard RJ45 connectors to connect to both DMX-based power/data supplies from Ethernet/DMX and PoE-compliant switches Ultra-compact design-Protocol Converter compatible with other PoE-compliant devices including all accessories support etc as required. with water proof M.S. Sheet panel of suitable size.
Supplying , installation , testing and commissioing of Key Pad - IP 30 - 136 W - Moduler Panel for 7 Scenes + Off ( 8 buttons) Allows to control a Lighting System with Frame Kit Availble in Stainless Steel Option With Single Chassis. Each module Fitted with Indicator LEDs And Infared Receiver that Gives option of Remote Operation By Hand Held Remote.. Panels use a Data protocol Which Confirms to the DALI Protocols.
Supplying , installation , testing and commissioning of Control Module and power supply suitable for Direct view luminaires,with IP66 rating, it should have outdoor data supply with slim housing that takes 24V DC power and combines it with either Ethernet or DMX512 control data, , with fuse-protection, outputs ports. panel mount connectors, 24V DC SELV Input,Two combined power and data output ports die-cast aluminium housing and Should be supplied with suitable rating power supply including all accessories fittings support etc as required.with water proof M.S. Sheet panel of suitable size.
Providing and fixing porcelain re-wireble fuse carrier and base unit on wooden board including drilling holes on the board, screws, connections etc. as per specification. (Thimbeling shall be paid separately). 32 amps
Providing and fixing porcelain re-wireble fuse carrier and base unit on wooden board including drilling holes on the board, screws, connections etc. as per specification. (Thimbeling shall be paid separately). 63 amps
Providing and making interconnection in cubical panel between BBC and switchgears with following size aluminium strip of length upto 50cm as per specification (To be measured separately for each phase/ neutral). 30x5mm (200 amps)
Providing and making interconnection in cubical panel between BBC and switchgears with following size FRLS PVC insulated copper conductor wire lead of length upto 50cm including providing copper thimbles on both ends as per specification (To be measured separately for each phase/ neutral). 16 sqmm (63 amp)
Providing and making interconnection in cubical panel between BBC and switchgears with following size copper strip of length upto 50cm as per specification (To be measured separately for each phase/ neutral). 20x3mm (100 amps)
Providing and making interconnection in cubical panel between BBC and switchgears with following size copper strip of length upto 50cm as per specification (To be measured separately for each phase/ neutral). 25x5mm (200 amps)
Providing and making interconnection in cubical panel between BBC and switchgears with following size copper strip of length upto 50cm as per specification (To be measured separately for each phase/ neutral). 40x5mm (300 amps)
Providing and making interconnection in cubical panel between BBC and switchgears with following size copper strip of length upto 50cm as per specification (To be measured separately for each phase/ neutral). 50x5mm (400 amps)
Providing and making interconnection in cubical panel between BBC and switchgears with following size copper strip of length upto 50cm as per specification (To be measured separately for each phase/ neutral). 60x5mm (500 amps)
Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification. Upto 300 mm deep
Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification. Above 300 mm and upto 450 mm deep
Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification. 750 mm deep
Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification. 900 mm deep
Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) aluminium bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 200 amp (30x5mm)
Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) aluminium bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 300 amp (50x5mm)
Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) aluminium bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 500 amp (75x6mm)
Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) aluminium bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 800 amp (100x6mm)
Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) copper (electric grade) bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 100 amp (20x3mm)
Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) copper (electric grade) bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 200 amp (25x5mm)
Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) copper (electric grade) bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 400 amp (50x5mm)
Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) copper (electric grade) bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 500 amp (60x5mm)
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 3 pole MCCB, 25-100A, Adjustable Thermal Release, 18KA
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 4 pole MCCB, 100A, Adjustable Thermal - Magnetic Release, 35KA
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 4 pole MCCB, 125A, Adjustable Thermal - Magnetic Release, 35KA
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 4 pole MCCB, 160A, Adjustable Thermal - Magnetic Release, 35KA
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 4 pole MCCB, 200A, Adjustable Thermal - Magnetic Release, 35KA
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 4 pole MCCB, 250A, Adjustable Thermal - Magnetic Release, 35KA
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 4 pole MCCB, 250A, Adjustable Microprocessor Release, 35KA
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 4 pole MCCB, 400A, Adjustable Microprocessor Release, 50KA
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 4 pole MCCB, 630A, Adjustable Microprocessor Release, 50KA
Supplying and fixing on surface/ recess prewired following way, 240 volts SP&N, MCB distribution board of sheet steel phosphatized and powder painted complete with loose wire box, terminal blocks, tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks including interconnections, earthing etc. as per specification. (But without MCB/ RCCB/ Isolator) 2 + 8 way, Double door
Supplying and fixing on surface/ recess prewired horizontal type following way, 415 volts TP&N, MCB distribution board of sheet steel phosphatized and powder painted complete complete with loose wire box, terminal blocks, tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks including interconnections, earthing etc. as per specification. (But without MCB/ RCCB/ Isolator) 4 way (4 + 12), Double door
Supplying and fixing on surface/ recess prewired horizontal type following way, 415 volts TP&N, MCB distribution board of sheet steel phosphatized and powder painted complete complete with loose wire box, terminal blocks, tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks including interconnections, earthing etc. as per specification. (But without MCB/ RCCB/ Isolator) 6 way (4 + 18), Double door
Supplying and fixing on surface/ recess prewired horizontal type following way, 415 volts TP&N, MCB distribution board of sheet steel phosphatized and powder painted complete complete with loose wire box, terminal blocks, tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks including interconnections, earthing etc. as per specification. (But without MCB/ RCCB/ Isolator) 8 way (4 + 24), Double door
Supplying and fixing on surface/ recess prewired vertical type following way, 415 volts TP&N, MCB distribution board of sheet steel phosphatized and powder painted complete with loose wire box, terminal blocks, 200 amps tinned copper busbar, common neutral link, earth bar, din bar, detachable gland plate, loose wire box, superior make terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks including interconnections, earthing etc. as per specification. (But without MCB/ RCCB/ Isolator) (Note: Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door
Supplying and fixing on surface/ recess prewired vertical type following way, 415 volts TP&N, MCB distribution board of sheet steel phosphatized and powder painted complete with loose wire box, terminal blocks, 200 amps tinned copper busbar, common neutral link, earth bar, din bar, detachable gland plate, loose wire box, superior make terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks including interconnections, earthing etc. as per specification. (But without MCB/ RCCB/ Isolator) (Note: Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.) 6 way (4 + 18), Double door
Supplying and fixing on surface/ recess prewired vertical type following way, 415 volts TP&N, MCB distribution board of sheet steel phosphatized and powder painted complete with loose wire box, terminal blocks, 200 amps tinned copper busbar, common neutral link, earth bar, din bar, detachable gland plate, loose wire box, superior make terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks including interconnections, earthing etc. as per specification. (But without MCB/ RCCB/ Isolator) (Note: Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door
Supplying and fixing SP MCB, 240 volts, 'B' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 6 amps to 32 amps
Supplying and fixing SP MCB, 240 volts, 'B' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 40 amps
Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 6 amps to 32 amps
Supplying and fixing DP MCB, 240 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 6 amps to 32 amps
Supplying and fixing TP MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 63 amps
Supplying and fixing TP&N MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 6 amps to 32 amps
Supplying and fixing TP&N MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 40 amps
Supplying and fixing TP&N MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 50 amps
Supplying and fixing TP&N MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 63 amps
Supplying and fixing TP&N MCB, 440 volts, 'D' curve, suitable for inductive/ motor load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 50 amps
Supplying and fixing TP&N MCB, 440 volts, 'D' curve, suitable for inductive/ motor load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 63 amps
Supplying and fixing following rating, 240 volts TWO POLE ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 40 amps
Supplying and fixing following rating, 240 volts TWO POLE ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 63 amps
Supplying and fixing following rating, 415 volts, FOUR POLES, ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 40 amps
Supplying and fixing following rating, 415 volts, FOUR POLES, ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 63 amps
Supplying and fixing following rating, 415 volts, FOUR POLES, ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 100 amps
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 40 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 40 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 63 amps
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as per specification.
Supplying and fixing 2 pole and earth, 240 volts, industrial type, socket outlet, enclosed metal plug top along with SP MCB in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as per specification. 20 Amp with “C” curve MCB
Supplying and fixing 2 pole and earth, 240 volts, industrial type, socket outlet, enclosed metal plug top along with SP MCB in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as per specification. 32 Amp with “C” curve MCB
Supplying and fixing Low voltage (class -II) surge protection device (SPD) TP&N 440 volts, in the existing MCB DB complete with connections, testing and commissioning etc. as per specification.
Providing and fixing approved make, Electrically Operated, draw out type, 415/500 volts, 4 pole air circuit breaker complete with all standard accessories as per manufacturers specifications including drilling holes on the board, connections, earthing the body, testing and commissioning etc. as per specification and Ics = Icu = Icw for 1 second, IS/IEC: 60898. 800 amps, 4 pole, 50 KA
Providing and fixing 3 pole, 415/500 volts following rating (AC-1 Duty) power contactor in existing starter/ cubical panel including, connections, testing and commissioning etc. as per specification. 40 amps
Providing and fixing 4 pole, 415/500 volts following rating (AC-1 Duty) power contactor in existing starter/ cubical panel including, connections, testing and commissioning etc. as per specification. 40 amps
Providing and fixing 4 pole, 415/500 volts following rating (AC-1 Duty) power contactor in existing starter/ cubical panel including, connections, testing and commissioning etc. as per specification. 60 amps
Providing and fixing following rating current transformer in existing cubical panel including, connections, testing and commissioning etc. as per specification. 100/5 amps
Providing and fixing following rating current transformer in existing cubical panel including, connections, testing and commissioning etc. as per specification. 500/5 amps
Providing and fixing following rating current transformer in existing cubical panel including, connections, testing and commissioning etc. as per specification. 800/5 amps
Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as per specification.
Providing and fixing penal mounting digital type ammeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification
Providing and fixing penal mounting 0-500 volt voltmeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification. Digital type
Providing and fixing panel mounting digital type VAF (Volt-amp-frequency combined) Multi Function meter of size 100x100 (NS) in existing cubical panel including connection, testing and commissioning etc. as per specification.
Supplying, installation, testing and commissioning following rating single phase in single phase out ON-LINE UPS including connection etc but without batteries as per specification. 3 KVA with DC bus voltage 72 V
Supplying, installation, testing and commissioning following rating single phase in single phase out ON-LINE UPS including connection etc but without batteries as per specification. 5 KVA with DC bus voltage 180 V
Supplying, installation, testing and commissioning following rating (Sealed Maintenance Free) lead acid battery including connection as per specification. 42 AH
Supplying, installation, testing and commissioning following rating (Sealed Maintenance Free) lead acid battery including connection as per specification. 100 AH
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode at 0.5 Metre depth below ground level including excavation and refilling the trench etc. as per specification.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as per specification.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering, excavation and refilling the trench etc. as per specification.
Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode at 0.5 Metre depth below ground level including excavation and refilling the trench etc. as per specification.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode at 0.5 Metre depth below ground level including excavation and refilling the trench etc. as per specification.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as per specification.
Providing maintenance free earthing with following size GI pipe including making bore pit of minimum 150mm dia, providing and laying approved make Earthing Electrode of Pipe-in-Pipe technology as per IS 3043(R 2016) -1987 made of corrosion free G.I. Pipes having outer pipe of 80mm dia and inner pipe of 50mm dia and filling with specified qty highly conductive compound around pipe and above that with soft soil in bore pit complete and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. as per specification: With 3 metre long GI Pipes and 50 kg back filling compound.
Providing maintenance free earthing with following size GI pipe including making bore pit of minimum 150mm dia, providing and laying approved make Earthing Electrode of Pipe-in-Pipe technology as per IS 3043(R 2016) -1987 made of corrosion free G.I. Pipes having outer pipe of 80mm dia and inner pipe of 50mm dia and filling with specified qty highly conductive compound around pipe and above that with soft soil in bore pit complete and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. as per specification: With 2 metre long GI Pipes and 25 kg back filling compound.
Supplying and laying ISI marked double wall HDPE pipe (IS 14930 Part II) having corrugation on the outer wall and plan surface on inner wall in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 63 mm outer dia and 50 mm Inner dia
Supplying and laying ISI marked double wall HDPE pipe (IS 14930 Part II) having corrugation on the outer wall and plan surface on inner wall in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 75 mm outer dia and 60 mm Inner dia
Supplying and laying ISI marked double wall HDPE pipe (IS 14930 Part II) having corrugation on the outer wall and plan surface on inner wall in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 90 mm outer dia and 75 mm Inner dia
Supplying and laying ISI marked double wall HDPE pipe (IS 14930 Part II) having corrugation on the outer wall and plan surface on inner wall in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 120 mm outer dia and 103.5 mm Inner dia
Supplying and laying following size RCC Hume pipe class NP-2 (in standard length of 2 metre) with collar in ground below road, path etc at a depth not less than 50 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 200 mm dia
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 3.5 x 25 sq. mm.
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 3.5 x 35 sq. mm.
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 3.5 x 70 sq. mm.
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 3.5 x 95 sq. mm.
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 3.5 x 240 sq. mm.
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 4 x 10 sq. mm.
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 4 x 16 sq. mm.
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) 2 x 10 sq. mm
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) 3.5 x 35 sq. mm
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) 4 x 16 sq. mm.
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 3½ X 25 sq. mm (25 mm)
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 3½ X 35 sq. mm (28 mm)
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 3½ X 50 sq. mm (32 mm)
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 3½ X 95 sq. mm (38 mm)
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 3½ X 240 sq. mm (57 mm)
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 4 X 10 sq. mm (22 mm)
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 4 X 16 sq. mm (22 mm)
Supplying and installing following size of perforated hot dipped Galvanised Iron cable tray (Galvanisation thickness not less then 50 microns) with perforation not more than 17.5% rigidly suspended from the ceiling with G.I. suspenders at a distance not more than 2.5 metre and near every junction/ joint etc complete as per specification. 300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated hot dipped Galvanised Iron cable tray (Galvanisation thickness not less then 50 microns) with perforation not more than 17.5% rigidly suspended from the ceiling with G.I. suspenders at a distance not more than 2.5 metre and near every junction/ joint etc complete as per specification. 450 mm width x 50 mm depth x 2.0 mm thickness
Supplying and installing following size of perforated hot dipped Galvanised Iron cable tray (Galvanisation thickness not less then 50 microns) with perforation not more than 17.5% rigidly suspended from the ceiling with G.I. suspenders at a distance not more than 2.5 metre and near every junction/ joint etc complete as per specification. 600 mm width X62.5 mm depth X 2.0 mm thickness
Supplying and fixing of following size of perforated hot dipped Galvanised Iron (Galvanisation thickness not less then 50 microns) cable tray "bends" (horizontal) turning at 90º in same plane with perforation not more than 17.5% rigidly jointed with cable tray etc. complete as per specification. 450 mm width X 50 mm depth X 1.6 mm thick
Supplying and fixing of following size of perforated hot dipped Galvanised Iron (Galvanisation thickness not less then 50 microns) cable tray "bends" (horizontal) turning at 90º in same plane with perforation not more than 17.5% rigidly jointed with cable tray etc. complete as per specification. 600 mm width X 62.5 mm depth X 2 mm thick
Supplying and fixing of GI Trunking/Raceways with 120 GSM coating and made up of 1.6 mm thick steel sheet. The steel sheet is Pre Galvanized with zinc coating and is double folded and arc welded in the joints to prevent concrete seepage. The trunking is compartmentalized for provision of data, power and voice cables and has a depth of 25/38mm complete as per specification. : Raw materials complies to Indian Standards IS 277:2003. 100 mm x 25 mm x 1.6 mm (1 compartment)
Supplying and fixing of GI Trunking/Raceways with 120 GSM coating and made up of 1.6 mm thick steel sheet. The steel sheet is Pre Galvanized with zinc coating and is double folded and arc welded in the joints to prevent concrete seepage. The trunking is compartmentalized for provision of data, power and voice cables and has a depth of 25/38mm complete as per specification. : Raw materials complies to Indian Standards IS 277:2003. 225 mm x 25 mm x 1.6 mm (3 compartments)
Supplying and fixing of Underfloor GI Trunking and joint sleeves with 120 GSM coating and made up of 1.6 mm thick steel sheet. The steel sheet is Pre Galvanized with zinc coating and is double folded and arc welded in the joints to prevent concrete seepage. The trunking is compartmentalized for provision of data, power and voice cables and has a depth of 25/38mm complete as per specification. : Raw materials complies to Indian Standards IS 277:2003. 100 mm x 25 mm raceway Jointing sleeves
Supplying and fixing of Underfloor GI Trunking and joint sleeves with 120 GSM coating and made up of 1.6 mm thick steel sheet. The steel sheet is Pre Galvanized with zinc coating and is double folded and arc welded in the joints to prevent concrete seepage. The trunking is compartmentalized for provision of data, power and voice cables and has a depth of 25/38mm complete as per specification. : Raw materials complies to Indian Standards IS 277:2003. 225 mm x 25 mm raceway Jointing sleeves
Supplying and fixing of L Shaped 2 compartment Vertical access boxes to connect the floor raceways to surface euipments. The vertical access boxes should be epoxy coated and has provision to Connect floor raceway in the bottom and other cable management products on the top side vertical. Verical access boxes to connect raceways upto 225mm
Supplying and fixing of L Shaped 2 compartment Vertical access boxes to connect the floor raceways to surface euipments. The vertical access boxes should be epoxy coated and has provision to Connect floor raceway in the bottom and other cable management products on the top side vertical. Vertical access boxes to connect raceways upto 300mm
Supplying and fixing of GI Junction boxes, suitable for 25/38 mm depth GI raceways. The junction boxes are made out of high pressure die cast zinc alloy complete with all accesseries such as trap lid, strong support frame, bore support studs etc. complete as per specification. Trap lid is reinforced and can with stand upto 2 tons of distributed load on the top. As per IEC 61084 Standards. 150 mmx 150 mm x 60 mm - 75 mm (1 compartment)
Supplying and fixing of GI Junction boxes, suitable for 25/38 mm depth GI raceways. The junction boxes are made out of high pressure die cast zinc alloy complete with all accesseries such as trap lid, strong support frame, bore support studs etc. complete as per specification. Trap lid is reinforced and can with stand upto 2 tons of distributed load on the top. As per IEC 61084 Standards. 250 mm x 250 mm x 60 mm - 75 mm (1 compartment)
Supplying and fixing of GI Junction boxes, suitable for 25/38 mm depth GI raceways. The junction boxes are made out of high pressure die cast zinc alloy complete with all accesseries such as trap lid, strong support frame, bore support studs etc. complete as per specification. Trap lid is reinforced and can with stand upto 2 tons of distributed load on the top. As per IEC 61084 Standards. 300 mm x 300 mm x 60 mm - 75 mm (1 compartment)
Supplying and fixing of Floor Access outlet boxes, manufactured from high-pressure die cast material with trap frame & trap made of robust mettalic lid. Patented screwless polyamide ratchets are provided for self adjusting of the floor box for any floor finishes. The trap cover should be provided with Electrostatic Polyester Epoxy Coating, to prevent rust accumulation.The system should have provision to accommodate three compartment trunking to run Mains Voltage & Extra Low Voltage cables. The system should have Positive Double Earthing Connections to ensure safety. There should be Provision to accommodate 25/38mm deep trunking with a Knockout of 100, 150,200,225,250mm. Load bearing capacity of 2 tons. 250 mm x 250 mm x 60 mm - 75 mm metallic lid ( 3 compartment)
Supplying and fixing of Floor Access outlet boxes, manufactured from high-pressure die cast material with trap frame & trap made of robust mettalic lid. Patented screwless polyamide ratchets are provided for self adjusting of the floor box for any floor finishes. The trap cover should be provided with Electrostatic Polyester Epoxy Coating, to prevent rust accumulation.The system should have provision to accommodate three compartment trunking to run Mains Voltage & Extra Low Voltage cables. The system should have Positive Double Earthing Connections to ensure safety. There should be Provision to accommodate 25/38mm deep trunking with a Knockout of 100, 150,200,225,250mm. Load bearing capacity of 2 tons. 300 mm x 300 mm x 60 mm - 75 mm ( 3 compartment)
Supplying and fixing of Aluminium alloy pop up boxes on floor/desk applications. The pop up boxes should have smooth hydrauilc opening with provision to mount power & data accessories. etc complete as per specification. Pop up boxes should also have base box made of steel+zinc plating with earth provision. 3 module pop up box
Supplying and fixing of Aluminium alloy pop up boxes on floor/desk applications. The pop up boxes should have smooth hydrauilc opening with provision to mount power & data accessories. etc complete as per specification. Pop up boxes should also have base box made of steel+zinc plating with earth provision. 4 module pop up box
Supplying and fixing of Aluminium alloy pop up boxes on floor/desk applications. The pop up boxes should have smooth hydrauilc opening with provision to mount power & data accessories. etc complete as per specification. Pop up boxes should also have base box made of steel+zinc plating with earth provision. 6 module pop up box
Supply of GI PIPE POLE made of "B" class GI pipe making necessary hole for cable entry and providing earthing stud (welded at specified height) including painting with one coat of red oxide zinc chromate primer. 80 mm dia
Supply of hot dipped galvanized (in single dip to minimum 75 micron) octogonal pole made of 3mm thick steel grade E-350 sheet having window and flush cover with locking arrangement at suitable height from base for cable termination block, pole suitably reinforced with welded steel section at window cut section to make the strength of pole unaffected, with following minimum specifications with 4 way terminal connector including 3mm thick anchor plate, 4 nos 20mm dia foundation bolts of EN8 grade, and as per IS 2062 & BS EN: 10025. (designed for wind speed upto 180km/hr, IS: 875 Part 3) 7 metre high, dia 130mm at bottom and 90mm at top, base plate size 220x220x12mm, foundation bolts 700mm long
Erection of GI octogonal/ tubular/conical pole on existing cement concrete foundation having grouted bolts and nuts, aligning in true vertical position as per specification. 3 metre high
Erection of GI octogonal/ tubular/conical pole on existing cement concrete foundation having grouted bolts and nuts, aligning in true vertical position as per specification. 7 metre high
Designing and providing suitable RCC foundation in Cement Concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) for 3 mere to 12 metre high GI octagonal pole including steel reinforcement form work, embeding 2 nos 50mm dia PVC pipe for cable entry in each foundation, excavation disposal of surplus soil and curing etc. as per specification.
Providing and making suitable CC pole collar (muffing) in Cement Concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) of size 0.4 m dia and 0.4 m height from existing CC foundation.
Supplying and fixing of double over hang (Arm) 1000 MM (long)x50 mm dia decorative GI street light pole bracket made out of GI "A" Class pipe welded to 300 MM Long GI Pole canopy of suitable dia at angle of 102.50 Degree including having GI triangular stiffner and making arrangement for tightening the bracket with pole by providing suitable size heavy duty nuts and bolts in canopy including FRP Dome on existing pole etc. as per enclosed drawing and as per direction of engineer-in-charge.
Supplying and fixing of single over hang (Arm) 1000 MM (long)x50 mm dia decorative GI street light pole bracket made out of GI "A" Class pipe welded to 300 MM Long GI Pole canopy of suitable dia at angle of 102.50 Degree including having GI triangular stiffner and making arrangement for tightening the bracket with pole by providing suitable size heavy duty nuts and bolts in canopy including FRP Dome on existing pole etc. as per enclosed drawing and as per direction of engineer-in-charge.
Supply of hot dip galvanized CONICAL POLEas per BSEN ISO 1461 standard with minimum coating thickness of 75 micron. The galvanizing shall be done in single dipping. The pole shaft shall be made from 3 mm sheet steel confirming to BSEN10025 having yield strength of 355N/ Sq mm and silicon content less than 0.04%.The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. All Conical pole shafts shall be provided with the rigid flange plate manufacture from MSFE410 confirming to IS: 2062 of suitable thickness with provision for fixing 4 Nos ‘J’ type foundation bolts. The welding shall be done as per qualified MMAW process approved by Third Party Inspectionagency. The Conical Poles shall be designed to with stand the maximum wind speed as per IS875 part III. The top loading i.e. area and the weight of fixtures are to be considered to calculate maximum deflection of the pole and the same shall meet the requirement of BSEN 40-2- 1 &3.The Conical Poles shall have door of approximate 500 mm length at the elevation of 500 mm from the Base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connections Supply of 3 M Height Conical Pole diameter 75 mm at top 107 at bottom. Baseplate Size 200 x 200 x 12 mm foundation bolt 450 mm long Mx16 EN 8 grade
Supplying and erection of angle/channel iron cross arms/ bracket/ other fitting of approved size and shape including drilling of holes for insulator pins, bolts and nuts etc as per specification.
Supplying, installation, testing and commissioning of centrifugal type mono-block electric pump set for water supply system having following capacity three phase, 415 volts AC induction motor and pump including suitable channel iron base frame, suitable C.C. foundation and connection of suction and delivery line etc. as per specification. 3 HP, 420 LPM, 20 m head, suction size 65 mm, delivery size 50 mm
Supplying, installation, testing and commissioning of centrifugal type mono-block electric pump set for water supply system having following capacity three phase, 415 volts AC induction motor and pump including suitable channel iron base frame, suitable C.C. foundation and connection of suction and delivery line etc. as per specification. 5 HP, 750 LPM, 20 m head, suction size 80 mm, delivery size 65 mm
Supplying, installation, testing and commissioning of submersible pump set for water supply system with submersible motor directly coupled to multi-stage submersible pump of specified discharge capacity, head, delivery size in existing bore well including 2 sets of suitable size holding clamps made out of 50 mm X 6 mm MS flat, connection with suitable submersible cable of standard length etc. as per specification and IS: 694 (2010). Note: submersible Cable should be rust proof, safe from oil / Grease and under water Chemical / abrasion Resistant. 1.5 HP, single phase
Supplying, installation, testing and commissioning of submersible pump set for water supply system with submersible motor directly coupled to multi-stage submersible pump of specified discharge capacity, head, delivery size in existing bore well including 2 sets of suitable size holding clamps made out of 50 mm X 6 mm MS flat, connection with suitable submersible cable of standard length etc. as per specification and IS: 694 (2010). Note: submersible Cable should be rust proof, safe from oil / Grease and under water Chemical / abrasion Resistant. 3.0 HP, three phase
Supplying and fixing following dia HDPE pipe PE-80 Grade (8kg/sqcm) in single length in the suction/ delivery line of water supply pump etc. as per specification. 32 mm outer dia
Supplying and fixing following dia HDPE pipe PE-80 Grade (8kg/sqcm) in single length in the suction/ delivery line of water supply pump etc. as per specification. 50 mm outer dia
Supplying and fixing of following sizes GM gate valve ISI mark in the suction/ delivery line etc. as per specification. 32 mm dia.
Supplying and fixing of following sizes GM gate valve ISI mark in the suction/ delivery line etc. as per specification. 50 mm dia.
Supplying and fixing of following sizes GM non return valve ISI mark in the suction/ delivery line etc. as per specification. 32 mm dia.
Supplying and fixing of following sizes GM non return valve ISI mark in the suction/ delivery line etc. as per specification. 50 mm dia.
Supply, installation, testing and commissioning of 1-3 HP 1 phase submersible motor starter cum control wall/ floor mounted type made out of not less than 1.6 mm thick MS sheet and comprising of following panel mounting switchgears there in including connection inter-connection etc. as per specification. a) Phase indicating lamps with fuses and toggle switches 1 set b) 1/2/3 HP 1 phase DOL starter with over load and no volt relay 1 No c) 25 A "C" curve DPMCB 1 No d) Voltmeter 0-250 V 1 set e) Ammeter 0-10 A 1 set
Supplying and fixing M.S. clamp 50 cm long made of 50mmx5mm thick M.S. Flat for holding the pipes and submerable pump set as per specification.
Supplying and fixing 300 mm dia 2 mm thick M.S. sheet cover with 3 cm edge in two past on tube well bore pipe as per specification
Supplying, laying and fixing following size submersible cable along with GI/PVC/HDFC pipe line or laid in ground etc as per specification and IS: 694 (2010). Note: Cable should be rust proof, safe from oil / Grease and under water Chemical / abrasion Resistant. 3x4.0 sqmm
Supplying, laying and fixing following size submersible cable along with GI/PVC/HDFC pipe line or laid in ground etc as per specification and IS: 694 (2010). Note: Cable should be rust proof, safe from oil / Grease and under water Chemical / abrasion Resistant. 3x6.0 sqmm
Supplying and laying of approved make stainless steel wire rope of 6 mm dia for support of submersible pump set complete with tying to pump set and pump holding clamp.
Supplying, installation, testing and commissiong of following size {storage volume } domestic refrigarator with BEE star rating,copper coil and eco friendly refrigerant, suitable puff insulation, built in voltage stabilizer and power saver compressor, conformity to IS: 1476, including all accessories connection etc complete as per specification. 260 ltr.
Supplying, installation, testing and commissiong of following size drinking water cooler storage type ISI marked, eco friendly non CFC refrigarant, water tank and cooler cabinet sheet material- stainless steel {grade AISI 304} with thickness>= 0.8 mm, with PUF insulation including all accessories connection etc complete as per specification. 60/120 Ltrs/hr
Supplying, installation, testing and commissiong of following size drinking water cooler storage type ISI marked, eco friendly non CFC refrigarant, water tank and cooler cabinet sheet material- stainless steel {grade AISI 304} with thickness>= 0.8 mm, with PUF insulation including all accessories connection etc complete as per specification. 150/150 Ltrs/hr
Supplying, installation, testing and commissiong of following capacity of RO purification system with UF/UV/TDS controler and UV lamp {IS 14724 Ultra voilet disinfection} and minimum three stage purification, automatic on/off, output water conferming standard IS 10500 with inbuild storage tank including all accessories connection etc complete as per specification. 50 Ltrs/hr output capacity
Supply installation,testing & commissioning of modular type variable refrigerant flow/variable refrigerant volume air cooled outdoor units suitable for cooling and heating, having all hermetically sealed inverter type scroll compressor(s), minimum two compressors for above 14HP modules, microprocessor based controller, top discharge type condensing unit(s), with R410a refrigerant, vibration isolators, with suitable foundation etc. Complete as per specification. The unit shall deliver the rated capacity at AHRI conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400v +/-10%, 3phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as per specification. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5
Supply, installation, testing and commissioning of following minimum capacity and external Static pressure VRV/VRF Ceiling Mounted Ductable Type Indoor unit equipped with synthetic washable media pre-filter, fansection with low noise fan/dynamically balanced blower, multispeed motor, coilsection with DX Copper coil, electronic expansion valve, outer cabinet, vibration isolators, cordless remote control, drain pan, other necessary accessories/Supports etc., suitable for operation on 230V±10%, 50Hz single phase AC supply, complete, as per specification. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.Mid Static Ductable Unit {Minimum 45 Pascal external static Pressure } 3.2 TR
Supply, installation, testing and commissioning of following minimum capacity and external Static pressure VRV/VRF Ceiling Mounted Ductable Type Indoor unit equipped with synthetic washable media pre-filter, fansection with low noise fan/dynamically balanced blower, multispeed motor, coilsection with DX Copper coil, electronic expansion valve, outer cabinet, vibration isolators, cordless remote control, drain pan, other necessary accessories/Supports etc., suitable for operation on 230V±10%, 50Hz single phase AC supply, complete, as per specification. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.Mid Static Ductable Unit {Minimum 45 Pascal external static Pressure } 4 TR
Supply, installation, testing and commissioning of following minimum capacity and external Static pressure VRV/VRF Ceiling Mounted Ductable Type Indoor unit equipped with synthetic washable media pre-filter, fansection with low noise fan/dynamically balanced blower, multispeed motor, coilsection with DX Copper coil, electronic expansion valve, outer cabinet, vibration isolators, cordless remote control, drain pan, other necessary accessories/Supports etc., suitable for operation on 230V±10%, 50Hz single phase AC supply, complete, as per specification. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.High Static Ductable Unit {Minimum 110 Pascal external static Pressure } 6.5 TR
Supply, installation, testing and commissioning of following minimum capacity and external Static pressure VRV/VRF Ceiling Mounted Ductable Type Indoor unit equipped with synthetic washable media pre-filter, fansection with low noise fan/dynamically balanced blower, multispeed motor, coilsection with DX Copper coil, electronic expansion valve, outer cabinet, vibration isolators, cordless remote control, drain pan, other necessary accessories/Supports etc., suitable for operation on 230V±10%, 50Hz single phase AC supply, complete, as per specification. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.High Static Ductable Unit {Minimum 110 Pascal external static Pressure } 8 TR
Supply, installation, testing and commissioning of following minimum capacity 4-Way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fansection with low noise fan/dynamically balanced blower, multispeed motor, coilsection with DX Copper coil, electronic expansion valve, outer cabinet, drainpump, grill, necessary supports, vibration isolation, cordless remote control etc., suitable for operation on single phase 230V±10%, 50Hz AC supply, complete, as per specification. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19Degree C WB temperature. 1.0 - 1.3 TR
Supply, installation, testing and commissioning of following minimum capacity 4-Way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fansection with low noise fan/dynamically balanced blower, multispeed motor, coilsection with DX Copper coil, electronic expansion valve, outer cabinet, drainpump, grill, necessary supports, vibration isolation, cordless remote control etc., suitable for operation on single phase 230V±10%, 50Hz AC supply, complete, as per specification. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19Degree C WB temperature. 2.0 - 2.5 TR
Supply, installation, testing and commissioning of following minimum capacity 4-Way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fansection with low noise fan/dynamically balanced blower, multispeed motor, coilsection with DX Copper coil, electronic expansion valve, outer cabinet, drainpump, grill, necessary supports, vibration isolation, cordless remote control etc., suitable for operation on single phase 230V±10%, 50Hz AC supply, complete, as per specification. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19Degree C WB temperature. 2.6- 3.3. TR
Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall Type Indoor unit equipped with synthetic washable media pre-filter, fansection with low noise fan/dynamically balanced blower, multispeed motor, coilsection with DX Copper coil, electronic expansion valve, outer cabinet, vibration isolators, cordless remote control, drain pan, necessary accessories/Supports etc., suitable for operation on 230V±10%, 50Hz single phase AC supply, complete, as per specification. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19Degree C WB temperature. 1.3 - 1.7 TR
Supply, Installation, Testing and commissioning of factory built floor/ceiling mounted DX type double skin type horizontal/vertical air handling units made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation (having density 48 kg/cu m) factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as per specification, minimum 4 bend GSS/PVC eliminators, DX type cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of 6 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters, belt drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply suitably designed for varialbe frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 nos.)and industrial type thermometers (2 nos.) at the inlet and outlet of coil, auto purge valve wherever required, including starter Pannel of suitable capacity, necessary vibration isolation arrangement, with mixing Box etc. complete as per specification and of following capacities. 20000 CFM
Supply, installation, testing and commissioning of following minimum capacity and external Static pressure Non VRV/VRF Ceiling Mounted/split type Ductable IDU & ODU equipped with synthetic washable media pre-filter, fansection with low noise fan/dynamically balanced blower, multispeed motor, coilsection with DX Copper coil, electronic expansion valve, outer cabinet, vibration isolators, cordless remote control, drain pan, other necessary accessories/Supports, fittings etc., suitable for operation on 230V±10%, 50Hz single phase AC supply, complete, as per specification. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. Ductable Unit 11 TR (Non VRV)
Supply, installation, testing and commissioning of AHU Kit 16.5TR.
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as per specification Thickness 0.63 mm sheet
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as per specification Thickness 0.80 mm sheet
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as per specification Thickness 1.00 mm sheet
Supplying and fixing of 19mm thickness closed cell Nitrile rubber (Class "O") insulation for Supply air duct on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specification.
Supply, Installation, Testing & Commissionig of flexible {canvas} connection between duct and Machine
Supplying and fixing 25 mm thick resin bonded fibre glass Acoustic insulation (on duct ) of density 24 kg/cu.m or mineral wool insulation(non combustible) of density 44 kg/cu m after applying two coats of cold setting adhesive (CPRX compound) sealing all joints with self adhesive aluminium tape & covering with 0.63mmx19mm GI wire mesh netting butting all joints and laced with GI wire complete and as per specification. (for indoor/outdoor applications).
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as per specification : 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
15.9 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
19.1 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
22.2 mm dia (OD) (Hard drawn)with tube thickness 1.2 mm with 19 mm thick insulation
25.4 mm dia (OD) (Hard drawn)with tube thickness 1.2 mm with 19 mm thick insulation
28.6 mm dia (OD) (Hard drawn)with tube thickness 1.2 mm with 19 mm thick insulation
31.8 mm dia (OD) (Hard drawn)with tube thickness 1.62 mm with 19 mm thick insulation
34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
41.3 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
Supplying and installation of Refnet Joints as per site conditions.
All Control /communication wiring between indoor and Outdoor Units with FRLS PVC conduit and necessary clamps/saddling etc. complate as requird.
Supplying, laying, fixing and installation of rigid PVC drain piping of 6 KG/sqcm, duly insulated with 6/9 mm thick nitrile rubber pipe section, complte with all necessary fitting such as elbows, tees, reducers, serviceable "P" traps etc. and supports such as clamps etc. complate as per specifications. 25 MM DIA
Supplying, laying, fixing and installation of rigid PVC drain piping of 6 KG/sqcm, duly insulated with 6/9 mm thick nitrile rubber pipe section, complte with all necessary fitting such as elbows, tees, reducers, serviceable "P" traps etc. and supports such as clamps etc. complate as per specifications. 32 MM DIA
Supplying, laying, fixing and installation of rigid PVC drain piping of 6 KG/sqcm, duly insulated with 6/9 mm thick nitrile rubber pipe section, complte with all necessary fitting such as elbows, tees, reducers, serviceable "P" traps etc. and supports such as clamps etc. complate as per specifications. 40 MM DIA
Supply and fixing of Powder Coated extruded Aluminium Return Air Grilles with louvers but without volume control dampers complete as per specification.
Supply, fixing, testing and commissioning of Supply Air Diffuser of Powder Coated Aluminium with Aluminium volume control dampers with antismudge ring and removable core.
Supply, installation, testing and commissioning of GI Volume Control Collar/ duct Dampers Complete with neoprene rubber gaskets. Nuts Bolts, screw linkages, flanges etc., as per Specifications
Supply & fixing Of MS stand for outdoor units
SITC Of VRV System including topping R-410 gas as per site requirements. Refrigerant shall be environment Friendly R-410
Suppying , installation , testing and commissioning of Fire alarm Control panel (UL LIsted) suitable for 504 addressable points (Detector & Devices). Comprising of the following system components: Operating units, Periphery boards, Power supplies,System enclosures, with battery backup 24hours and 30minutes,32-character custom messages ,
Suppying , installation , testing and commissioning of Intelligent Addressable Type Manual Call Point: Intelligent Manual Fire Alarm Box is constructed of durable, molded and polycarbonate material that is matte finished in red with raised white lettering Single-action,Pull-down lever is down, until manually reset,Polarity insensitive via SureWireTM technology
Suppying , installation , testing and commissioning of Response Indicator for above false ceiling detector
Suppying , installation , testing and commissioning of Intelligent Addressable Relay control module for Hooter Interfacing and supervising normally open (N.O) or normally closed (N.C) contacts,Integral single-pole, double-throw (SPDT) relay (up to 4 amps) ,Multi-color light-emitting diode (LED) indicates system status, UL Listed & ULC Listed; FM Approved
Suppying , installation , testing and commissioning of 2 core x 1.5 sq.mm Armoured FRLS fire cable
Supply and erecting of following ISI marked Fire extenguishers on wall/ column including erecting bracket etc complete. ABC Fire Extinguisher 6KG Nitrogen Store Pressure As per IS: 15683:2018 Body Sheet Not Less Then 2mm Thickness, CE Mark NRV Valve With ABC Powder 90% UL 299 FIRE RATING: 4A, 144B. With all accessories.
Supply and erecting of following ISI marked Fire extenguishers on wall/ column including erecting bracket etc complete. ABC Fire Extinguisher 4KG Nitrogen Store Pressure As per IS: 15683:2018 Body Sheet Not Less Then 2mm Thickness, CE Mark NRV Valve With ABC Powder 90% UL 299 FIRE RATING: 2A, 89B. With all accessories.
Supply and erecting of following ISI marked Fire extenguishers on wall/ column including erecting bracket etc complete. CO2 type Fire Extinguisher ISI marked confirming to IS:15683:2018 Capacity 3Kg. INITIAL CHARGE:- Carbon dioxide used in extinguishers shall comply with IS 15222. FIRE RATING:- 34B. Complete with Hose Assembly and horn, locking arrangement, operation manual, bracket with two screw and sleeve
Supply and erecting of following ISI marked Fire extenguishers on wall/ column including erecting bracket etc complete. CO2 type Fire Extinguisher ISI marked confirming to IS: 15683:2018 Capacity 2 Kg. INITIAL CHARGE:- Carbon dioxide used in extinguishers shall comply with IS 15222. FIRE RATING:- 21B. Complete with Hose Assembly and horn , locking arrangement, operation manual, bracket with two screw and sleeve
Supplying , installation , testing and commissioning of electrical motor driven main pump of horizontal centrifugal end suction backpull out type of cast iron body, bronze impeller, SS 410 shaft with mechanical seal and capable to deliver 2280 LPM at 70 MWC.The pump shall be coupled to TEFC motor of suitable 60 HP with speed of 2875 RPM and complete set shall mounted on common base frame. The quoted rate shall includes providing & fixing of coupling, coupling gaurd, RCC foundation( as recommended by manufacturer) and Foundation bolts etc.
Supplying , installation , testing and commissioning of electrical motor driven Jockey pump of horizontal centrifugal end suction closed coupled type of cast iron body, bronze impeller, SS 410 shaft with mechanical seal gland packing and capable to deliver 180LPM at 70 MWC.The pump shall be coupled to TEFC motor of suitableHPwith speed of 2900RPM and complete set shall mounted on common base frame. The quoted rate shall includes providing & fixing of coupling, coupling gaurd, RCC foundation( as recommended by manufacturer) and Foundation bolts etc.
Supplying , installation , testing and commissioning of diesel Engine driven common stand by pump, horizontal centrifugal end suction backpull out type of cast iron body, bronze impeller, SS 410 shaft with mechanical seal and capable to deliver 2280 LPM at 70 MWC. The pump shall coupled to suitable 67 HP of Diesel engine radiator water cooled type with speed of 2150 RPM and complete set shall be mounted on common base frame. 12 vBatteries & battery leads with stand, Fuel tank ( for 6 Hrs. operation ) with stand & gauge glass, Fuel piping with valves. The quoted rate shall includes radiator water cooling piping(if reqired) coupling gaurd and other stanadrd accessories,RCC foundation (as recommended by manufacturer) and foundation bolts, etc. complete.
Supplying , installation , testing and commissioning of 2 MP Bullet Camera weather & dust proof IP based Fixed Lens day/night Camera (IP67 , IK 10) , 2 MP CMOS Image Sensor ,H.265 and H.264 triple-stream WDR(120dB), Day/Night, UL ,CE FCC Certified as per the specifications.
Supplying , installation , testing and commissioning of 4 MP Bullet Camera weather & dust proof IP based Fixed Lens day/night Camera (IP67 , IK 10) , 1/3” 4MP PS CMOS Image Sensor, H.265 and H.264 triple-stream encoding, WDR(120dB), Day/Night Support, UL ,CE FCC Certified as per the specifications.
Supplying , installation , testing and commissioning of 2 MP DOME Camera weather & dust proof IP based Fixed Lens day/night Camera (IP66) 2Megapixel CMOS Image Sensor,H.265 / H.264 triple-stream encoding , WDR(120dB), Day/Night UL, CE, FCC Certified as per the specifications.
Supplying , installation , testing and commissioning of 2 MP PTZ Camera weather & dust proof IP based Dome PTZ (Pan Tilt & Zoom) true day& night camera ,1/2.8” 2MP PS CMOS Image sensor, Max. 25/30fps@1080P,Color: [email protected]; [email protected] (IR on), Powerful 25x Optical and 16x Digital zoom, WDR(120dB), 3D DNR, Day/Night(ICR),Defog, ROI, , BLC, HLC, Support Starlight Function, Up to 300 presets, auto scan, 8 tour, 5 pattern, auto pan, IR Range of 100 Mtr., Max 300° /s pan speed, 360° endless pan rotation, Support PoE+, UL, CE ,FCC certified as per specifications.
Supplying , installation , testing and commissioning of 16 Channel NVR 2 Sata port Up to 16 channel IP camera input , Max 200Mbps incoming bandwidth ,Smart H.265+/H.265/Smart H.264+/H.264 dual codec decoding , Up to 8MP resolution preview and playback , Support 2 SATA HDDs up to 6 TB each, 2 USB(1 USB3.0, 1 USB2.0) , 1 HDMI / 1 VGA simultaneous video output ,ONVIF Version 2.4 conformance , Alarm In / out 4/2 , Two way talk 1 Channel Input, 1 Channel Output RCA , 1 RJ-45 port (10/100/1000Mbps) as per the specifications.
Supplying , installation , testing and commissioning of 64 Channel NVR 8 Sata port Up to 64 channel IP camera input , Max 320Mbps incoming bandwidth , Smart H.265+/H.265/Smart H.264+/H.264/MJPEG , Up to 12MP resolution preview and playback , Support 8 SATA HDDs up to 10TB each,1 eSata , 4 USB(2 USB3.0, 2USB2.0) , 2 HDMI / 2 VGA simultaneous video output ,ONVIF Version 2.4 conformance , Alarm In / out 16/6 , Two way talk 1 Channel Input, 2 Channel Output RCA , 1 RS485, 1 RS232 , 2 RJ-45 port (10/100/1000Mbps), Support ANPR Camera as per the specifications.
Supplying , installation , testing and commissioning of 8 Port Industrial POE Switch 10/100/1000 8 Port with 4 Giga SFP Uplink, Industrial POE Switch , Support Dual DC Power Backup as per the specifications.
Supplying , installation , testing and commissioning of 24 Port PoE Switch 10/100 24 Port with 2Giga & 2 SFP Combo Uplink Ports, Power Budget 250W as per the specifications.
Supplying , installation , testing and commissioning of 4 TB Surveillance Hard disk drive Complete as required
Supplying , installation , testing and commissioning of 6U Indoor Rack Wallmount 6U 450D With Front Glass Door Lock & Key 550 6U - loaded with cable manager + PDU + Fan complete as required.
Providing installation testing and commissioning of 12U Indoor Rack Wallmount 12U 450D With Front Glass Door Lock & Key 550 12U - (Fan, cable manager, PDU included) complete as required.
Providing installation testing and commissioning of 15U Indoor Rack Wallmount 15U 630D With Front Glass Door Lock & Key 550 15U - (Fan, cable manager, PDU included) complete as required.
Supplying, installation, testing and commissioing of following size LED Monitor, table/wall mount with inbuild speaker minimum 5Wx2,with minimum 1 No of HDMI and USB port including remote control, connecting cable, batteries, and all accessories, connection etc complete as per specification 32 inch
Supplying, installation, testing and commissioing of following size LED Monitor, table/wall mount with inbuild speaker minimum 5Wx2,with minimum 1 No of HDMI and USB port including remote control, connecting cable, batteries, and all accessories, connection etc complete as per specification 43 inch
Supplying, installation, testing and commissioing of following size LED Monitor, table/wall mount with inbuild speaker minimum 5Wx2,with minimum 1 No of HDMI and USB port including remote control, connecting cable, batteries, and all accessories, connection etc complete as per specification 55 inch
Supply, installation , testing and commissioning for basic small EPABX cabinet with expandable upto 40 port with CPU and power supply
Supply, installation , testing and commissioning for basic EPABX system cabinet expandable upto 224 port with CPU card and power supply.
Supply, installation , testing and commissioning of add-on item for operator console (for large EPABX)
Supply, installation , testing and commissioning of add on item for Digital phone 2 row with DSS key. (for large EPABX)
Supply, installation , testing and commissioning of add on item for push button caller ID phone and speaker. (for large EPABX)
Supply, installation , testing and commissioning of add on item junction box installed with Mount frame inside for Krone 10 pair disconnection/disconnections module, Corrosion free impact resistant, water proof, mild steel stable and maintenance free with same size crone module as junction box. 20 Pair Juction box
Supply, installation , testing and commissioning of add on item junction box installed with Mount frame inside for Krone 10 pair disconnection/disconnections module, Corrosion free impact resistant, water proof, mild steel stable and maintenance free with same size crone module as junction box. 50 Pair Juction box
Supply, installation , testing and commissioning of single line cordless phone with dialling display and speaker 2.4 GHz frequency supported Ni-MH battery, redial memory.
Supply, installation and testing for HDMI cable.
Supply installation and testing for VGA cable.
BSTUPTS
BSPUPTS
CGHCB
CHiPS
CGMSC
CGPHC
CGRBEKVN
CSIDC
CGSMB
CGMFPFED
CGSPDCL
CGSPGCL
CGSPTCL
CGSWC
CGTBC
DBUPTS
KRBAUPTS
KRYAUPTS
RIGUPTS
RUPTS
RNDGUPTS
SUPTS
hectare
joint
litre
Man-Month
meter
metre
one RCC jaali tree guard
one RCC jaali tree guard
P.cumt.
P.Pair
P.Point
p.sq.mtr
P/sq.Mt.
per cm height per letter
per cm height per letter
per cubic centimeter
Per Km.
per letter
Per mtr
per pouch
per test
per tonne
per tonne capacity
per.mtr
Point
quintal
Roll_UD
SHEET
Sq.mtr
Tonne
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
815179402317396192_158612_7802287293814106_134633_Guidelines_to_Bidders.pdf
NIT • 0.13 MB
7129954246166414710_203205_FORM B.doc
NIT • 0.17 MB
9034956702938502597_203205_NIT.doc
NIT • 0.30 MB
523637882679232019_203205_PQ.doc
NIT • 0.28 MB
8889238254641716059_203205_203205 Notice.docx
NIT • 0.06 MB
104416655444908394_203205_Annexure E and List of Approved Materials Rajbhawan.docx
NIT • 0.03 MB
882758035637045857_203205_BOQ.xlsx
BOQ • 0.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .