HUBBALLI DIVISION: Proposed construction of warehouse and improvements of CC road in GSD/UBL. Maintenance Periode:36 MONTHS
40UBL25-26DT261125ITEM02~SWR
40UBL25-26DT261125ITEM02
Open
Works - General
12 Months
Dharwad, Karnataka
₹0
₹6.3 L
24 Dec 2025
27 Nov 2025
10 Dec 2025
D2-SCH-D2 SW-II
Item Breakup - B-SCH-B SW-I
Supplyint and applying two components Sqm anti-slip epoxy coating (as per IR Standard Specifications) which should withstand heavy vehicular and pedestrian traffic and should adhere to metal, wood and concrete surfaces. It should be chemical resistant. The job includes priming of surface with suitable primer, abrasive cleaning of surface, followed by cleaning with solvents
Preparation of Site plan, GAD and designing Sqm foundation and other structural design, preparation of detailed structural drawing and submission of design calculation with check print for verification and corrections, carrying out correction as per corrected check print and submission of 4 copies of drawing with negative and floppy etc., as per general arrangement drawing and submission of completion drawing as per the execution in tracing paper/tracing film after completion of work duly incorporating any deviation/changes carried out during execution from original approved drawing without completion drawing final bill will not be finalized
Conducting recognized Government Institution Total 2669940.00
Item Breakup - D-SCH-D SW-II
Item Breakup - D-SCH-D SW-I
0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 0.75 sqm.) Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing 9.147D frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. HUBLI DIVISION-ENGG/SOUTH WESTERN RLY 9.147D.1 Two track two panels sliding window made Sqm 48 7634.1 366436.8 of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 23 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) 9.150 Providing and fixing zinc alloyed (white Each 40 167.15 6686 powder coated) touch lock for uPVC sliding 24 window with necessary screws etc. complete. 10.0 STEEL WORK 10.17 Providing and fixing M.S. fan clamp type I or Each 20 185.95 3719 II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams 25 during laying, including painting the exposed portion of loop, all as per standard design complete. 10.28 Providing and fixing stainless steel ( Grade Kg 500 612.25 306125 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & 26 stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 12.0 ROOFING Providing, fixing and embedding sand cast iron accessories for rain water pipes in the masonry surrounded with 12 mm thick 12.40 cement mortar of the same mix, as that of masonry (lead caulking will be paid for separately): Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including 12.41 jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 27 12.41.2 110 mm diameter Metre 200 319.75 63950 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain 12.42 water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 12.42.1 Coupler 28 12.42.1.2 110 mm Each 20 119.95 2399 12.42.5 Bend 87.5 degrees 29 12.42.5.2 110 mm bend Each 40 132 5280 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. 12.43 screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. HUBLI DIVISION-ENGG/SOUTH WESTERN RLY 30 12.43.2 110 mm Each 80 309.5 24760 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long 12.45 G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.45.1 12.5 mm thick tapered edge gypsum plain Sqm 300 1145.95 343785 31 board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs 12.47 incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. HUBLI DIVISION-ENGG/SOUTH WESTERN RLY 12.47.1 2 mm thick corrugated (2.5" or 4.2" or 6") Sqm 300 1179.25 353775 32 or step-down (2" or 3" or 6" ) as specified 12.50 Providing and fixing precoated galvanised Sqm 3500 671.55 2350425 iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in- charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid 33 scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, 12.51 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : 34 12.51.1 Ridges plain (500 - 600mm) Metre 80 450.6 36048 35 12.51.4 Barge board (Upto 300 mm) Metre 100 384.2 38420 36 12.51.6 Gutter (600 mm over all girth) Metre 160 1110.6 177696 13.0 FINISHING 13.1S CEMENT PLASTER (IN FINE SAND) 13.1 12 mm cement plaster of mix : 37 13.1.2 1:6 (1 cement: 6 fine sand) Sqm 1000 282 282000 13.19S ROUGH CAST PLASTER Rough cast plaster upto 10 m height above ground level with a mixture of sand and gravel or crushed stone from 6 mm to 10 mm nominal size, dashed over and including the fresh plaster in two layers, 13.19 under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement. 13.19.1 Ordinary cement finish using ordinary Sqm 200 752.4 150480 38 cement 13.44S EXTERIOR FINISHING Finishing walls with Acrylic Smooth exterior 13.46 paint of required shade : 13.46.1 New work (Two or more coat applied @ Sqm 3600 166.85 600660 1.67 ltr/10 sqm over and including priming 39 coat of exterior primer applied @ 2.20 kg/10 sqm) Finishing with Deluxe Multi surface paint 13.48 system for interiors and exteriors using Primer as per manufacturers specifications : 13.48.1 Two or more coats applied on walls @ 1.25 Sqm 1000 158.95 158950 40 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm HUBLI DIVISION-ENGG/SOUTH WESTERN RLY 13.48.3 Painting Steel work with Deluxe Multi Sqm 2500 140.05 350125 Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over 41 an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 13.80 Providing and applying white cement based Sqm 600 123.85 74310 putty of average thickness 1 mm, of 42 approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 16.0 ROAD WORK 16.1S ROADS 16.3 Supplying and stacking at site. 43 16.3.10 Moorum cum 2975 888.3 2642692.5 16.47S PAINTING AREA/RUNWAY MARKING Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior 16.47 make as approved by the Engineer-in- charge, i/c cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete. 44 16.47.1 New work (Two or more coats) Sqm 300 158.5 47550 16.49S MISCELLANEOUS Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium 16.60 alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-in-charge. (Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment). 45 16.60.1 Overhead informatory road signage Sqm 10 5609.55 56095.5 HUBLI DIVISION-ENGG/SOUTH WESTERN RLY 16.68 Providing and laying 60mm thick factory Sqm 300 951 285300 made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in 46 required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. 16.93 Providing and placing in position 100 mm Sqm 70 2617.15 183200.5 thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on 47 finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in- Charge. 20.0 PILE WORK Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of garde M-25 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of 20.2A appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). 48 20.2A.1 600 mm dia piles Metre 3075 4514.4 13881780 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head 20.6 or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in- charge. Group of two or more piles upto 50 tonne 20.6.3 Safe capacity 20.6.3.1 Initial test (Test Load 2.5 times the Safe Each 2 66227.9 132455.8 49 capacity) Test Cyclic vertical load testing of pile in accordance with IS Code of practice IS:2911 20.7 (part IV) by Kentledge method including preparation of pile head etc for. Lateral load testing of single pile in accordance with IS Code of practice IS : 20.8 2911 (Part IV) for determining safe allowable lateral load on pile : 20.8.1 Each 2 18463.55 36927.1 50 Upto 50 tonne capacity pile Test HUBLI DIVISION-ENGG/SOUTH WESTERN RLY 20.9 Integrity testing of Pile using Low Strain/ Each 205 982.55 201422.75 Sonic Integrity Test/ Sonic Echo Test Test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean 51 concrete lumps etc. and use of computerised equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-in-charge. Total 55142612.50
Item Breakup - B1-SCH-B1 SW-I
Excavation in trenches in any kind of soil of cum required width and laying of LT UG cables, including excavation for joints, and dressing of sides, ramming of bottoms, depth upto 1.5 m, Including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50M
Supply and laying of high density Metre polyethylene pipe (HDPE pipe) of size 50 mm (OD) category of PE-80, PN-6 along with accessories (T joint / straight coupler etc.), ISI marked and drawing LT cables all as per specification
Transportaion, commissioning of LTUG cable 4cx25/4cx16/4cx35/4cx50 sqmm as per specification. Note: LT UG cable will be issued by Railways. The contractor will be responsible for collection of cables from the Elect Maintenance / Works Depot including loading, unloading, transportation and return of un-used cables back at Depot. Costs of these provisions are deemed to be included in the quoted rates.
Supplying and making end termination with Each compression gland with double check nuts and aluminum lugs for 50 Sqmm size, 4 core of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as specified and directed.
Supplying and making end termination with Each compression gland with double check nuts and aluminum lugs for 16 Sqmm size, 4 core of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as specified and directed.
Cutting of cement concrete (PCC) surface, cum any type for laying of UG cables in trenches and disposing off the excavated material as directed including barricading, danger lighting and refilling the trenches in layers and consolidating complete all as specified and directed.
Material and Labour for Earthing with G.I Set earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing mansory enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with Charcoal/coke and salt as required. HUBLI DIVISION-ENGG/SOUTH WESTERN RLY
Providing and fixing 25 mm x 5 mm G.I strip Metre on surface or in recess for connections etc, as required.
Supplying and fixing 4 way (4+12), double Each door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surfce/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, power painted including earthing etc as required.
Supplying and fixing 50 A to 63 A rating, Each 415 V, 10 KA, "C" curve, TPN miniature circuit breaker suitable for inductive load of in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply and fixing 63 A, triple pole and Each neutral 415 V. residual current circuit breaker (RCCB) having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc, as required.
Supply and Provision of DP MCB of 6A-32A Each rating with short circuit breaking capacity of 10KA.
Supply and Provision of SP MCB of 6A-32A Each rating with short circuit breaking capacity of 10KA.
Material and Labour for submain wiring Metre along with earth wire with the size of 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit including all necessary connected works such as cutting chases, drilling holes on wall/ ceiling etc including plastering/ making good the disturbed surfaces all as specified and as directed. Note: (i) Surface wiring shall be opted only where recessed wiring is not feasible and as per the direction/approval of the Engr-In-Charge.
Material and Labour for submain wiring Metre along with earth wire with the size of 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit including all necessary connected works such as cutting chases, drilling holes on wall / ceiling etc including plastering / making good the disturbed surfaces all as specified and as directed. Note: (i) Surface wiring shall be opted only where recessed wiring is not feasible and as per the direction/approval of the Engr-In-Charge. HUBLI DIVISION-ENGG/SOUTH WESTERN RLY
Material and Labour for submain wiring Metre along with earth wire with the size of 2 X 4 sq. mm + 1 X 4 sq. mm earth wire FRLS PVC Insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit Including all necessary connected works such as cutting chases, drilling holes on wall/ ceiling elc including plastering/making good the disturbed surfaces all as specified and as directed. Note: (1) Surface wiring shall be opted only where recessed wiring is not feasible and as per the direction/approval of the Engr-in- Charge.
Material and labour for point wiring for light Numbers point/ fan 31 point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC Insulated copper conductor single core cable etc. as required. Note: (i) Surface wiring shall be opted only where recessed wiring is not feasible and as per the direction/approval of the Engr-in-Charge.
Supplying, Commissioning of 60 100 W Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%. Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.
Supplying & fixing of 20/22 W LED Batten Numbers fitting, 240 V 20 AC with diffuser and driver incluidng all connected materials as per detailed tender /SWR specification.
Supply and fixing of LED modular down Numbers light 1' x 1' fitting 20 22-34 W, with lamps, recess or surface type as per site requirements including all necessary fixing arrangements complete als as per detailed tender /SWR specification.
Supply & fixing of single phase AC 230 V, Numbers 50 Hz modular type BLDC Exhaust fan 200 mm sweep complete with all accessories such as frame with louvers, necessary mounting arrangements, nuts bolts, fastners including making suitable openings on walls, finishing the surfaces etc all as specified and directed.
Supply & fixing of BLDC ceiling Fans, Numbers working on 230 V AC, 50 Hz of Sweep size, 1200 MM with detailed technical specification.
Supplying and fixing 3 pin, 5 A ceiling rose Numbers on the 31 existing junction box/ wooden block including connections etc. as required. HUBLI DIVISION-ENGG/SOUTH WESTERN RLY
Supplying and fixing suitable size Gl box Numbers with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required
Supplying and fixing 3 pin 5/6 A moudular Each socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc, as required.
Supplying and fixing 3 pin 5/6 A moudular Each switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 6 pin15/16 A moudular Each socket outlet 5 on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 6 pin 15/16 A Each moudular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing suitable size Gl box Numbers with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
Steel work welded in built up sections/ Kg framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Design, Supply, fixing, connecting, testing Each and commissioning of LT Control Panel, cubical type, 160 A. 3 phase 4 wire system with copper bus bars of size 30 x 6 mm, outdoor type, opening from both front and rear sides, separate compartments for each control gear, cable alley and provision of knock out type entry plates suitable up to 185 sqmm size cables, panel made out of 2 mm thick CRCA sheet, epoxy powder coated with grey matt finish, including base frame made out of 50 x 50 x 6 mm angle iron sections, embedded in PCC 1:3:6 foundation, consisting of the following switchgears and metering devices:-(1) MCCB 160 A, 4P, 36 KA with microprocessor based release 01 No. (ii) MCCB 100 A, 4P. 36 KA with microprocessor based release 01 No (iii) COS 100 A, 4P,415 V-01 No. (iv) MCB 63 A, 4P, 10 KA, 06 Nos. (v) MCB 5-32 A, DP, 10 KA-06 Nos. (vi) Multi function 3 phase meter-1 including CTs, pilot lamps complete all as specified and directed. HUBLI DIVISION-ENGG/SOUTH WESTERN RLY
Fabrication, supply and erection of 6 Mtrs Each long hot dip 20 galvanized octogonal pole with BSEN 10025 grade $355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, backelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for 6 m pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom 130 mm, top 70 mm with 3 mm thick suitable base plate and 4 Nos foundation bolts, necessary excavation for foundation and refilling all as specified and directed (excluding PCC foundation).
Supplying, and fixing of Hot dip Galvanized Each M.S.Bracket 20 suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete- Single Arm Bracket with 1000 mm Standard 40/50 mm dia.
Providing and making steel pole collar with cum cement concrete (1:3:6) with stone aggregate 20 mm nominal size in foundations of specified size and shape including form work, plastering if required, curing etc as required. (Volume of pole /pipe not to be deducte
Supplying and embedding 40 mm dia Gl Metre pipe, medium 30 class, in pole collar / foundation (During casting) for cable entry including bending the pipe to the required shape complete as required.
Supply and fixing of 70 W, LED Street light Each fitting as per 20 detailed tender / SWR specifications.
Supplying and drawing 3 x 2.5 sq mm of Metre FRLS PVC insulated copper conductor, single core cable in the existing surface/ PVC conduit as required
Supply and provision of Water cooler (Non Numbers CFC Refrigerant) Energy Efficient, Compressor, 60 Ltrs. /Hrs cooling Cap, Type storage Cap. 120 Ltrs. Rate of Max. Energy comsuption Watts-775, with all connected materials and works. Total 1623418.88
Item Breakup - D2-SCH-D2 SW-II
Item Breakup - D2-SCH-D2 SW-I
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .