Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.5 L+₹32,880.43 (4.60%)Rejected-Finance | L2 | Rejected-Finance REJECT |
Tender Value
₹7.2 L
EMD Value
₹7,161
Closing Date
22 Aug 2024, 3:00 pmClosed
COMMISSIONER MADURAI CORPORATION
Aringar Anna Maligai
Replacement of fully damaged 600MM dia Rcc pipe line relaying the 600MM DI pipe ellisnagar and attending water supply leak in ward 59
2024_MAWS_470869_1
E7 / Est.No. 538 / 23-24
Open Tender
Civil Works
Lump-sum
60 days
Madurai
Please refer Tender documents.
1 document required · 1 mandatory
₹0
₹7,161
12 Nov 2024
8 Aug 2024
22 Aug 2024
8 Aug 2024
22 Aug 2024
8 Aug 2024
Amount
600MM Removing the burst R.C.C pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete. (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers TWAD P.N 288 23-24
DUCTILE IRON SOCKET/SPIGOT PIPES FOR CLASS K9 AS PER IS 8329/2000 TWAD P.N 48 23-24 600MM k9
Laying, jointing ,testing C.I/D.I pipes including earthwork excavation for trenches in hard stiff clay, stiff black cotton, hard red earth, shales,murams, gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil, depositing the earth on banks with initial lead of 10 metres , lowering into trenches and aligning, refilling the trenches with excavated soil, watering and rammingtoconsolidation,disposal ofsurplus earth etc., complete (Timbering included forDepth2.50m,3.0m,3.5m,..........upto 8.5m) (o to 2.5m) DEPTH METRO P.N 66 22-23 600MM
Supply of M.S Sheet for barrel work TWAD P.N 65 23-24
Laboure charges for M.S Sheet lath and weilding work TWAD P.N 14 23-24
Earthwork excavating and depositing on bank with an initial lead of 10metres and initial lift of 2 metres in Hard stiff clay, stiff black cotton, Hard red earth, shales, murram, gravel, stoney earth, and earth mixed with small size boulders and hard gravelly soil etc., complete., TWAD P.N 303 23-24
UN PLASTICIZED O-PVC PIPES FOR POTABLE WATER SUPPLY AS PER IS 16647 / 2017PN 16 Class 500 TWAD P.N 26 23-24 200MM
Laying and jointing PVC slotted pipes in the inflitration gallery excluding cost of pipes but including charges for special tools and plants etc., complete such as air compressor and helmet. TWAD P.N 268 22-23
Refilling the trenches with suitable excavated earth available along the allignment after the pipes &specials are laid joimted &tested in layers &watering ramming &consolidation directed by the engineer in charge
CI D/F SLUICE VALVE WITH CAP/ WHEEL AS PER IS 14846/2000 PN 1.0 WITH ISI MARKING AND WITH 5 YEARS WARRANTY TWAD P.N 68 23-24
Fitter (Pipe laying / Bar bending) I Class Laboure charges for value fitting work TWAD P.N 13 23-24
Fitter I Class
Hire charges for deploying earth moving machinery (JCB/Poclain) for earthwork including diesel, oil and labour charges etc., complete. for value fitting work TWAD P.N 334 23-24
Dewatering the trenches during excavation and layhing jointing of sewers by engaging diesel pumpset up to 7.5 H.P & fuel ,crew,hire chatges transportation and all oyher items of work complete as per standard specifications and as directed by engineer (TWAD BOARD) P.NO 321 23-24
Barricading work ( Where , there is less traffic areas and brother roads etc.) for laying of pipe line using casurina poles at 1.50 m center to center ( 8cm to 10cm dia and 1.80 m height) Vertical with horizontal poles in three rows including painting the vertical poles in the road facing sides with ready mix paint, tying the vertical and horizontal poles with coir rope including fixing charges and fixing 75mm dia reflectors including earth work excavation for fixing vetical posts and finally removing and stacking the materials safely for further use etc., complete and as directed by TWAD P.N 335 23-24
Lighting arrangements (maintenance works) with genset:Hire charges for portable genset1.00 KVA with 2 nos of 150W flood light including all incidental charges, transporation, crew charges and fuel charges etc., complete. TWAD P.N 334 23-24
Attending water supply leak of 450mm P.S.C pipe For Collar joint only. DATA
Add GST 18%
SRI VISALAKSHI CO (BID ID -1114272)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .