Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹28.0 L+₹1.4 L (5.28%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹36.9 L+₹10.3 L (38.6%)Rejected-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L3 | Rejected-AOC L3 | |
| 4 | L4₹37.0 L+₹10.4 L (39.0%)Rejected-AOC C 40 BHAGAT SINGH NAGAR BHIND ROAD GWALIOR MP 474005 | NA | NA | 474005 | L4 | Rejected-AOC L4 |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
17 Aug 2023, 6:00 pmClosed
GE Bharatpur
GE Kanjoli line Bharatpur-321026
Repair/maintenance of DG sets security light sign board sub stn bldgs and certain works sewar fort KLP Mallah pump house area under GE Bharatpur
2023_MES_606878_1
8307/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bharatpur
As per NIT
6 documents required · 6 mandatory
₹500
GE Bharatpur
₹76,000
Yes
23 Sept 2023
30 Jun 2023
19 Aug 2023
30 Jun 2023
17 Aug 2023
4 Aug 2023
1 Jul 2023 - 19 Jul 2023
Amount
Excavation in trenches not exceeding 1.5 m wide and not exe 1.5 M in depth and getting out in Soft Loose soil.
Returning filling in including spreading leveling, watering and well ramming in layers not exe 25 cm each layer.
Removing excavated material to a distance not exe 50 M and depositing where directed not exceeding 1.50 M above the starting point.
Supply spreading in trenches fine dry river sand for cable protection and punning down gently by hand all as specified.
M&L for cable protection cover with sub Class`B` bricks old size laid dry, flat perpendicular across the cable in trenches specified & directed by Engg in charge.
S & F in replacement street light GI bracket of 1.2 mtr long made out of 40mm dia light grade GI pipe bend to shape of 120 degree end welded at required including 02 Nos MS clamp of flat iron 40 x 6mm with nuts bolts & washers for fixing on wall complete necessary fixing arrangements on pole incl taking out old U/S bracket as directed.
S & F in replacement PVC insulated and PVC sheathed cable with multi standed aluminium solid conductor of size 4 SqmmX2 core from over head ACSR conductor/junction box to street light fitting complete all as directed by Engineer-in-charge.
Boring of holes under road, pavement, hard standing by trenchless technology using suitable tools and machinery for laying of pipe upto 150mm bore complete all as specified and as directed . Note :- GI pipe shall be measured and paid in concern Item
S & F or laying galvanised steel tubing medium grade (ISI marked) for protection of under ground cable on poles/walls under road crossing of size 40mm bore complete all as specified and as directed by Engineer-in-Charge.
Taking out old un-servicable/ faulty PVC armoured LT under ground cable of any size any core complete all as specified and as directed by Engineer-in-Charge.
S&F or laying ross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with aluminium conductor, 1100 volts grade of cross-sectional area 16 Sqmm X 4 core laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc including commissioning and testing complete all as specified and as directed by Engineer-in-Charge.(Note: :- (i) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately.)
do but size 25 sqmm X 4 core
Supply, laying, testing & commissioning LT XLPE PVC insulated heavy duty electric cable of single core 120 Sqmm with stranded copper conductor 1100 volts grade (ISI marked) in trenches/pipes or fixed on pole complete all as specified and directed.
Supply, laying, testing & commissioning LT XLPE PVC insulated heavy duty electric cable of single core 95 Sqmm with stranded copper conductor 1100 volts grade (ISI marked) in trenches/pipes or fixed on pole complete all as specified and directed.
Supply, laying, testing & commissioning LT XLPE PVC insulated heavy duty electric cable of single core 70 Sqmm with stranded copper conductor 1100 volts grade (ISI marked) in trenches/pipes or fixed on pole complete all as specified and directed.
Dismantling and taking down non functional/ unserviceable street /security light fittings of any type (HPSV/bulk head light/CFL etc)of capacity upto 400W existing complete all as specified and directed by Engineer-in-Charge.
Supply, install, test and commissioning in replacement factory made THERMOPLASTIC/HDPE CABLE JUNCTION BOXES IP 66/67 “weather proof”, with terminals for outdoor installation (with knockouts for cable entry) of size 205 x 255 x 112 mm depth with cable entry size of 10-25 sqmm with terminal incl Aluminium bus bar of 63amp-04 Nos and MCB SP 6amp-01 No complete all as specified and directed.
Supply & fix in replacement 60 watts LED street light fitings new generation energy saving ,environmental friendly ,long life,versatile pressure die cast aluminium with following specification IP66 with 10KV surge protection , PF>0.95, THD < 10%, input voltage 220-240V AC, operating voltage (VAC) 100V -300 V, Lum Flux (+-) 10% , CRI -80 Lum efficienacy (+-) 10% CCT -5700K road way,luminaire with high power LED as light source with warranty option of 5 years and suitable drivers etc and connecting with 2 x 1 sq mm multistranded PVC insulated copper conductor with PVC Conduit 20mm dia from fittings to the jucntion box and fixing to complete all as specified and directed , Cat part no LSTP-60-CDL-M Make: Cromption/Havells/Bajaj or equivalen
All as per item No 21 here-in-before but 70 watt LED fittings.
Ditto all as per item No 21 here-in-before but LED flood light fittings 200 watts 230 volt complete and all assy duly prewired and pressure die cast aluminium housing,heat resistant tough glass with frame,IP 66 protection ans better optic for uniform distribution. Make:- Crompton / Philips/Bajaj/Havells
supply and fixing 1X9 Watt square shaped integral decorative LED (warm white)Bollard polycarbonate diffuser and IP 65 protection and mounting og fitting with PCC foundation all as directed Make :- Bajaj Cat Part No - BGBOS6009W LED or equivalent in Philips/C&G
M&L submain wiring complete with 2X4 sqmm single core multi strandred PVC insulated and sheathed cable FRLS copper conductor and one run of 4 Sqmm copper cable for earth continuity conductor and including rigid PVC conduit with all PVC accessories fixed on concealed surface complete. Make : Havells/polycab/KEI
S&F in replacement MCCB 04 pole 63 Amp, Thermal maganatic, adjustable type, breaking capacity not less than 16 KA,415 volts complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement MCCB 04 pole 100 Amp, Thermal maganatic, adjustable type, breaking capacity not less than 25KA,415 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and spread 20/40 mm stone aggregate in layers inside the substation switching yard including leveling,ramming complete all as specified and directed.
Supply, installing, testing and commissioning, factory made and tested, automatic power factor control panel (APFC Panel) with MD-XL heavy duty capacitor bank of 30KVAR feeder pillar(IP-55) suitable for out door installation (with canopy) consisting of 2/3/5/10 KVAR capacitor unit in tier formation housed in integrated cubical type automatic switching ""ON""&""OFF"" control panel fabricated out of CRCA steel sheet of minimum thickness 3.15 mm outer sheet and inner 2 mm thick, double door type with dust and vermin proof hinged and lockable door complete with interconnection, bonding to earth and panel body to powder coated (suitable for 400/440 volts,3 phase 50 HZ supply system ) automatic switching with microprocessor based relay ""ON""&""OFF"" control pannel for 30 KVAR capacitor each panel consist of following :- Complete all as specified and directed INCOMING :-(a) 01 No 63 Amps TP MCCB,25KA rupturing capacity microprocessore based (Icu=100% Ics) INDICATING PANEL :- (a) Phase ammeter with required CTs and phase voltmeter (b) phase indicating lamps each backed up with 2 amp MCB (c) indicating lamp for each 2/3/5/10 KVAR capacitor unit to indicate that unit is ""ON"" & ""OFF"" (d) CT of ratio 100/5 with accuracy class 1.0 shall be supplied with the panel to mount in the main feeder pillar.(e) Microproccessor based stepped APFC relay with 8 steps (f) Aluminium BUs bar of 200 A shall be provided.
Taking down old unserviciable submersible pump set ,disconnecting the electrical connection and taking out unserviciable/existing submersible pump set from the bore well including cable and rope and deposite to MES store yard complete all as specified and directed. and supply , Installation,testing and commissioning of new submersible motor ,electric driven 415 Volts +2% C/S per second ,squirel cage induction AC Motor 12.5 HP inclusive lowering of motor and connecting of starter pannel complete all as specified and directed. Note:- The cost of transportaion to MES store is deemed to be included in the quoted rate.
supply and fixing high density poly ethylene pipes(HDPE)bore of pipes 50mm of pressure rating 6 kgf/cm fixed in wall or in floors etc all as specified and directed.
Taking down old unserviciable submersible pump set , disconnecting the electrical connection and taking out unserviciable/existing submersible pump set from the bore well including cable and rope and deposite to MES store yard complete all as specified and directed.and supply , Installation,testing and commissioning of new submersible pump 7 stage, TP suitable for 200/250 dia bore well (casing pipe size 200/250/300 mm) suitable of 100 mm bore delevery pipe suitable for 12.5 HP submersible motor inclusive lowering of pump and connecting of starter pannel complete all as specified and directed. Note:- The cost of transportaion to MES store is deemed to be included in the quoted rate.
supply and fixing of PVC insulated and PVC sheathed flat submersible cable 4X3 core with stranded copper conductor 1100 Volts grade suitable for submersible motors and pumps and making electric connections all as specified and directed.
supply and fixing of PVC insulated and PVC sheathed flat submersible cable 6X3 core with stranded copper conductor 1100 Volts grade suitable for submersible motors and pumps and making electric connections all as specified and directed.
Supply and fixing of nylon rope 20mm dia in lowering of pump set and cable all as specified and directed.
Supply and fixing in replacement of Lithium base Energy efficient integrated Solar street light of 36 watt in single FRP body duly polyurethane coating (Camouflage color), encases with monocrystalline solar PV panel of 65-67Wp,lithium battery 11.1/12.8V,33.0 AH with inbuilt BMS,IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminium reflector for better light distribution ,CRI>70, color temp 5700K-6500K Microcontroller based charge controller cum driver,automaticdimming function(First 04 hrs at full brightness & rest of the time at lower light level with PIR motion sensor), Dusk to dawn operation,suitable to working temp (-) 10C to (+) 55C ,weight not more thatn 16-18 Kg with adjustable MS clamp suitable for pole/wall mounting etc complete as reequired.Make: AXXON/HAVELLS/PHILLIPS/CG Protections: Short circuit, overload,Reserve polarity and battery protection.Firm should provide vital parametres Test report from NABL accredited lab and should be of made in India with CE & ROHS complaint.
M & L for double legged informatory sign board of size 1.00m x 1.50m (Appx 1.5 sqm) fixed on single frame, both side and meeting back to back on the stainless steel 50x50x3.65mm square pipe. The board are of high intensity grade RETRO-REFLECTIVE SHEETINGOF AVERY DENNSION sheeting made out of 2mm thick alcoband sheet /aluminium composite pannel sheet conforming to IS-736,colour as approved by Engg-In-Charge and stainless steel square pipe of size 50x50x3.65mm with nut and bolt. The lettering will be computerised on board over verticle post 50mm stainless square pipe, 3.65 mm thick 3.20m long having 2 Nos flat iron strip of strip 40x5 mm, 0.30mm long on bottom and fixed with PCC 1:3:6 type C-1 (using 20mm graded stone aggregates) in post holes of size 0.45x0.45x0.75 M including dismentaling of old board complete all as specified and directed.
M & L for double legged informatory sign board of size 5.00m x 4.50m (Appx 20.5 sqm) fixed on single frame, both side and meeting back to back on the stainless steel 50x50x3.65mm square pipe. The board are of Acralic sheeting of avery dennison made out of 2mm thick acralic sheet , colour as approved by Engg-in-Charge and stainless steel square pipe of size 50x50x3.65mm with nut and bolt. The lettering will be computerised on board over verticle post 50mm stainless square pipe, 3.65 mm thick 3.20m long having 2 Nos flat iron strip of strip 40x5 mm, 0.30mm long on bottom and fixed with PCC 1:3:6 type C-1 (using 20mm graded stone aggregates) in post holes of size 0.45x0.45x0.75 M including dismentaling of old board complete all as specified and directed.
M & L for Earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm buried directly in the ground vertically to depth not less than 2.25 Mtr below the ground level with the top edge of earth plate, depth not less than 1.5 Mtr below the ground level connected to GI earth strip of 32 mm x 6 mm size by means of bolts, nuts and washers protected by GI tubing light grade 40 mm dia uptoTest point 20 mm dia watering pipe with funel & wire mesh, PCC pit in PCC 1:2:4 using 20 mm stone aggregates chamber 40 mm thick RCC cover slab (1:2:4) type B-1 using 20 mm graded stone aggregates complete all as specified and shown in electrical plate No.3 of SSR Part-I including earth work in any type of soil ,removal of surplus sil and providing charcol dust & salt layers all around the earth plate upto 15 cm all as required specified & directed by engr in charge. ( For LT panel and Transformer) ( Note:- Up to 7.5 Mtr length of pipe of 40 mm dia and GI strip shall be deemed to be included in unit rate quoted by tenderer GI pipe and GI strip beyond 7.5M will be measured separately under respective item.
M & L for bore well Earthing complete with the help of machnical boaring machine of 150mm dia 30 mtr depth, supply and fix 150mm bore ,UPVC pipe 6 kg/sqcm rating,06 tr long with the help of suitable size clamp with nut bolts and washer -01 no including charcoal dust, salt fill in bore well for achieve earth conductivity less than 1 ohm. M&L for covering of bore well mouth with PCC (1:2:4) type B1/Brick masonry pit of size 45X45X45 cm complete and give the minimum earth test result below 1 ohm complete all as specified and directed by Engineer-In-charge . ( Note:- (i) The earth pit shall be refilled by boulders free from vegitable soil. (ii) Earthing shall be tested by contractor in presence of Engr-In-Charge record shall be maintained.payment shall be admissible only after satisfactory test results.GI Pipe electrode and GI strip shall be measured & paid separately.
supply & lowering of GI tubing 50 mm dia medium grade in incl necessary fittings for lowering in borewell of depth up to 30 mtr and providing necessary holes in pipe to achieve good earth conductivity complete al as specified and directed.
S&F GI strip 32X6 fixed on wall or buried in ground and connected to the earth plate or any other indicated situation complete all as specifed and directed.
M & L for chemical Earthing complete with Copper plate 600 x 600 x 3.mm buried directly in the ground vertically to depth not less than 2.25 Mtr below the ground level with the top edge of earth plate, depth not less than 1.5 Mtr below the ground level connected to copper strip of 25 mm x 3 mm size by means of bolts, nuts and washers , returning & filling the pit with excavated soil mixing with charcoal 250 KG ,crystal salt 200 KG , magnesium sulphate of 100 KG and vegitable soil all around the plate up to 350 mm above from top edge of plate and balance portion filling with excavated soil in layers not exceeding 25mm thick, 25 mm galvanized iron medium grade watering pipe up to top of plate ,50 mm bore galvanized iron light grade pipe for earth strip protection , including all excavation earth work in any type of soil ,PCC 1:3:6 type C1 for chamber of internal size 300 mm X300X300mm with 120 mm thick wall and 700 mmX700mmX150 mm thick ,bed concreate,RCC 1:2:4,type B1 for precast chamber cover 50 mm thick ,reinforced with welded steel wire fabric of XPM jali (weight not less than 4.00 Kg/sqm),funnel,with wire mesh, complete al as specified and directed. Note:- Up to 7.5 Mtr length of pipe of 40 mm dia and copper strip shall be deemed to be included in unit rate quoted by tenderer.)
krishna Associate
PD GUPTA AND COMPANY
SHRI HARI CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .