Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.8 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED BEING LOWEST BIDDER | |
| 2 | L2₹61.8 L+₹19.1 L (44.7%)Rejected-Finance | L2 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 3 | L3₹63.2 L+₹20.5 L (48.0%)Rejected-Finance | L3 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 4 | L4₹67.9 L+₹25.2 L (59.0%)Rejected-Finance 02 PADRI SHIV NAGAR SHIV NAGAR MAHARAJGANJ UTTAR PRADESH 273303 | MAHARAJGANJ | UTTAR PRADESH | 273303 | L4 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 5 | L5₹70.1 L+₹27.4 L (64.2%)Rejected-Finance | L5 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
Tender Value
₹100.0 L
EMD Value
₹1.8 L
Closing Date
13 Oct 2023, 6:00 pmClosed
CWE Kirkee
Headquarters CWE Khadki, Military Engineer Services, Range Hills Road, Khadki, Pune-411003
REPAIR MAINT TO FENCING BOUNDARY WALL GATES PATH DRAINS, CULVERTS HARDSTANDING PAVED AREAS AND ALLIED WORKS IN ZONE A OF AGE B/R-I CENTRAL UNDER GE CENTRAL KHADKI
2023_MES_619955_1
CWE/KKE/TOKEN-16 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
CWE Kirkee
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE CENTRAL KHADKI
₹1.8 L
2 Jan 2024
21 Sept 2023
17 Oct 2023
21 Sept 2023
13 Oct 2023
6 Oct 2023
22 Sept 2023 - 25 Sept 2023
Amount
Excavating in post holes in soft/loose soil (or similar holes) each n. exc 0.5 Cum getting out returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm watering, and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and as directed.
M & L for cement concrete (1:2:4) type B-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete.
Dismantling posts or struts embedded in Concrete, brick work, masonary, etc (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specifed and as directed.
S & F for Joist,channel, angle or tee section fixed independly without connecting plates etc (cut to ordinary length) Fe 410-W (gde-E-250 quality A) etc complete all as specified and as directed.
Dismantling fencing wire mesh, any type, size and any position and removing the unserviceable wiremesh from work site as desired.
Supply only MS galvanised Chain link fencing, of size 100mm x 100mm of 3mm dia, complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
S & F for Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins including taking down etc. as directed (each line wire to be measured) complete all as specified and as directed.
Fixing only Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc. as directed (each line wire to be measured) complete all as specified and as directed.
S & F for mild steel Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles and removing the debris outside the defence land complete all as specified and as directed
M & L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar (1:4) etc complete all as specified and as directed.
All as per item No 13 above but except stone complete all as directed.
M & L for pre-cast cement concrete solid block masonry with solid block of the grade Type C-1, (1:3:6) using 20mm graded aggregate set in CM (1:4) complete all as directed.
Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints as specified of random rubble walling, coursed, hammer dressing with maximum depression on face from straight edge held against the dressed surface n.exc 40mm on lime/sand stone all as specified and directed.
M&L for Raised pointing to RR masonry in CM 1:4 all as specified and directed.
Removing cement mortar from and cleaning stones, obtained from masonry of any description (except ashlar facings and dressed stone work) and stone setts from pavings; stacking for measurement including all extra handling and removal and disposing off rubbish complete all as specified and as directed.
M & L for 15mm thick Rendering on brick /concrete surface in CM 1:4 with water profing compound finishing even & smooth without using extra cement and similar like etc complete all as specifed and as directed
Taking down steel / iron gates area not exc 10 Sqm each including hold fasts and re-fixing the gates in the same opening including shifting and fixing of existing holdfast in plain cement concrete (1:2:4), type B-1 after raising the gate level including greasing, painting and other necessary minor repairs complete all as specified and as directed.
M & L for Framed work as in doors or gates of angle or other section (i.e flat/tubular) with gusset plates, rails, braces of Fe-410-W (Gde-E-250) quality-B, etc. complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges/holdfast or steel hanging door fittings in plain cement concrete (1:2:4), type B-1 (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
S & F for 1mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc as per required at site complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc 15cm thickness (below of above ground level) and removing the debris outside the defence land complete all as specifed and as directed.
M & L for plain cement concrete type D-2 (1:4:8) (using 40mm graded stone aggregate) as in sub base complete all as specifed and as directed.
M & L for plain cement concrete (1:2:4) type B-2, 100mm thick (using 40mm graded stone aggregate) finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed.
M & L for plain cement concrete (1:3:6) type C-2, 75mm thick (using 40mm graded stone aggregate) finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed.
M & L for Chequered cement concrete rubber moulded coloured tiles glossy finish 300mm x 300mm x 25mm thick , set jointed and pointed in neat cement slurry in floors over and including 20mm thick screed bed of cement mortar (1:4) including pointing with white cement with pigment to match the shade of tiles including demolition of existing tiles and removing the debris outside the defence land complete all as specifed and as directed.
M & L for cement concrete (1:2:4) type B-1 (using 20mm graded stone agg) as in bed block, benching, kerb, mud stop, rounded or chamferred on edges, coping including necessary formwork wherever required complete all as specifed and as directed
M&L for Rubber moulded coloured glossy finish (Red, Yellow & Black) precast concrete interlocking paver blocks with grey cement and pigment any shape and size, shade as approved by GE for, 60mm thick conforming to IS 15658-2006 M-35 grade and interstices filled with sand including 40mm thick sand cushion and including demolition of existing tiles and removal outside the MoD land complete all as specified and as directed.
M&L for Rubber moulded coloured glossy finish (Red, Yellow & Black) precast concrete interlocking paver blocks with grey cement and pigment any shape and size, shade as approved by GE for, 80mm thick conforming to IS 15658-2006 M-40 grade and interstices filled with sand including 40mm thick sand cushion and including demolition of existing tiles and removal outside the MoD land complete all as specified and as directed.
M & L for Granite 20mm thick work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms, vertical surface of wall also and like in 12mm thick screed bed or bedding layer cement mortar (1:3) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including dismantling and removing the debris outside the defence land complete all as specified and as directed.
M & L for Providing precast cement concrete 1:2:4 type B-0 (12.5 mm graded aggregate) as in louvres and jallies, 40 mm thick and Set in Cement Mortar 1:6 including demolition of existing RCC jallies and removing the debris outside the defence land complete all as specified and as directed.
Demolition of (reinforced) cement concrete of any description and in any position and thickness all as specified and as directed (Reinforcement cut as to facilitate demolition).
M & L for reinforcement cement concrete (nominal mix) Type B-0 (1:2:4) (12.5mm graded aggregate) for walls, retaining walls, basement walls, ballast walls and like any thickness above top of footing including attached pilaster and buttresses etc.
M & L for formwork to soffits of suspended slabls such as roof slab, floor slabs, landing and similar work not exceeding 200mm thick (Horizontal or sloping) work in rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railing, opening in concrete wall, floor and roofs n. exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n. exc 20cm wide etc complete all as specified and as directed.
S & F for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specifed and as directed.
All as per sr item 37 but 5 mm dia and over up to and including 10mm dia in stirrups, spacers and binders all as specified and directed.
M & L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter as in rough finished surface of concrete flat/square/rectangular complete all as specified and as directed.
M&L for form work to sides of pillars, posts, struts, piers, columns and stanchions rough finished surfaces of concrete square, rectangular or polygonal complete all as specified and directed.
M & L for RCC Nominal Mix Type B1 (1:2:4 ) (using 20 mm graded aggregate) as in columns , pillars, piers, posts and struts complete all as specified and directed.
M&L for RCC Nominal mix Type B1 (1:2:4) (using 20mm graded agg) as in Foundations, including rafts,footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs,under-reamed piles and mass concrete etc complete all as specified and as directed.
Excavating in trenches n. exc. 1.5 m wide and n. exc. 1.5 m in depth; for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n. exc 10 Sqm on plan and n. exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers n. exc 25cm in soft/loose soil in excavated pit or trenches complete all as specified and as directed.
Removing excavated soil/material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
M & for providing Precast cement concrete block Type B-1 (1:2:4) (using 20mm graded agg) factory made as in Bed blocks, kerb stone etc with plain fair faces including chamfers, weathering, throating etc and setting in cement mortar 1:4 including demolition of existing kerb stones and removing the debris outside the defence land complete all as specified and as directed.
M & L for preparation of new or previously untreated steel surface of any description over 10cm in width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M & L for 15mm thick Rendering on brick /concrete or dubbed surface in CM 1:6 with water profing compound finishing even & smooth without using extra cement and similar like at any height including necessary scaffolding , ladder & formwork including taking down cement plaster, raking out joints, hacking for key & scrubbing down with water and removing the debris outside defence land complete all as specifed and as directed. (Note : water proofing compound shall be measured & paid separetely)
M & L for 15mm thick Rendering on brick /concrete or dubbed surface in CM 1:4 with water profing compound finishing even & smooth without using extra cement and similar like at any height including necessary scaffolding , ladder & formwork including taking down cement plaster, raking out joints, hacking for key & scrubbing down with water and removing the debris outside defence land complete all as specifed and as directed. (Note : water proofing compound shall be measured & paid separetely)
Supply only water proofing compound complete all as specifed and as directed.
M&L for preparation of new plastered wall surface and applying two coat of oil bond distemper emulsion white or tined over one coat of alkali resistance primer , on plastered surfaces, preparatory on wall complete all as specified and directed.
M & L for preparing new plastered surface of walls and applying two coat of cement base paint at any height including necessary scaffolding ladder etc complete all as specifed and as directed.
M & L for complete removal of existing treatement/old plastered/concrete surface from internal surface of wall by wire brushes & stopping of surfaces & levelling/edging the disturbed places/edges using necessary filling compound of Birla/JK wall care putty to obtain smooth regular/even finish using sand paper and applying two coat of oil bound distemper upto height 10 mtr etc complete all as specified and as directed.
M & L for preparation of old painted steel surface of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed
SUNIL VEER CONSTRUCTION
MAHESH DADAJI BACHHAV
JP ENTERPRISES
Shri Sant Cosntruction
UNIQUE ENGINEERS
S.R.M.K Enterprises
M/S Tirupati Goroba Shendge
Mukund Engineers and Contractors
Arun Kumar Deedwania
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .