Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹44.6 LAccepted-AOC NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | ₹44.6 L Quoted ₹44.8 L | L-1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER |
| 2 | L-2₹45.3 L+₹46,390.02 (1.04%)Rejected-Finance | ₹45.3 L+₹46,390.02 (1.04%) | L-2 | Rejected-Finance BEING L2 BIDDER |
| 3 | L-3₹45.6 L+₹81,673.42 (1.82%)Rejected-Finance CHOLADHARA JORAHAT 785001 ASSAM | JORHAT | ASSAM | 785001 | ₹45.6 L+₹81,673.42 (1.82%) | L-3 | Rejected-Finance BEING L3 BIDDER |
| 4 | L-4₹46.0 L+₹1.2 L (2.64%)Rejected-Finance | ₹46.0 L+₹1.2 L (2.64%) | L-4 | Rejected-Finance BEING L4 BIDDER |
| 5 | L-5₹48.6 L+₹3.8 L (8.40%)Rejected-Finance AVAS VIKAS NANDANPURA JHANSI UP 284003 | JHANSI | UTTAR PRADESH | 284003 | ₹48.6 L+₹3.8 L (8.40%) | L-5 | Rejected-Finance BEING L5 BIDDER |
| Sl No | Description | Qty | Unit | Purbanchal Construction Co L2 | SONI ENTERPRISE L4 | PURBANCHAL BUILDERS L1 | ADITI CONSTRUCTION CO. L6 | Technolinks L3 | M/S Hema construction L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling ACSR or AAC Conductors from the disturbed span including line spacer, etc., complete all as specified and as directed by Engineer-in-charge. | 4 | QTL | 150 ₹600 | 210 ₹840 | 69 ₹276 Lowest | 185 ₹740 | 80 ₹320 | 165 ₹660 |
| 2.00 | Dismantling Cross-Arms of Mild Steel Channel or Angle Sections, etc, including Mild Steel Bolts, Nuts, Washers, etc., complete all as specified and as directed by Engineer-in-charge. | 3 | QTL | 110 ₹330 | 55 ₹165 | 49 ₹147 Lowest | 125 ₹375 | 90 ₹270 | 140 ₹420 |
| 3.00 | Dismantling Insulators like Pin type, Shackle type from existing Street/ Security Light Pole of any description and any size, seggregating Seviceable Insulators and keep in safe custody for re-use, complete all as specified and as directed by Engineer-in-charge. | 80 | EACH | 25 ₹2,000 | 36 ₹2,880 | 9 ₹720 Lowest | 20 ₹1,600 | 45 ₹3,600 | 55 ₹4,400 |
| 4.00 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge. | 676 | CUM | 265 ₹1,79,140 | 240 ₹1,62,240 | 299 ₹2,02,124 | 345 ₹2,33,220 | 135 ₹91,260 Lowest | 310 ₹2,09,560 |
| 5.00 | Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge. | 390 | CUM | 122 ₹47,580 | 85 ₹33,150 | 109 ₹42,510 | 190 ₹74,100 | 55 ₹21,450 Lowest | 170 ₹66,300 |
| 6.00 | Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge. | 286 | CUM | 235 ₹67,210 | 210 ₹60,060 | 219 ₹62,634 | 310 ₹88,660 | 85 ₹24,310 Lowest | 190 ₹54,340 |
| 7.00 | M&L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as per specified and as directed by Engineer-in-charge. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for. | 203 | CUM | 1,360 ₹2,76,080 | 1,463 ₹2,96,989 | 1,499 ₹3,04,297 | 1,540 ₹3,12,620 | 1,840 ₹3,73,520 | 1,350 ₹2,74,050 Lowest |
| 8.00 | Supply & Laying Sub-Class B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge. | 20.02 | PER 1000 NOS | 14,750 ₹2,95,295 | 15,960 ₹3,19,519.2 | 14,999 ₹3,00,279.98 | 14,250 ₹2,85,285 Lowest | 16,520 ₹3,30,730.4 | 14,600 ₹2,92,292 |
| 9.00 | S&F of Galvanised Iron Pipe 40mm bore (dia) ‘light grade’ for protection of UG Cable, laid under Floors or Road Crossing, fixing to Pole with and including Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed by Engineer-in-charge. | 12 | RM | 550 ₹6,600 | 565 ₹6,780 | 599 ₹7,188 | 425 ₹5,100 Lowest | 448 ₹5,376 | 460 ₹5,520 |
| 10.00 | All as per Item No. 09 here-in-above, but for 50mm bore (dia) pipe, complete all as specified and as directed by Engineer-in-charge. | 12 | RM | 680 ₹8,160 | 645 ₹7,740 | 699 ₹8,388 | 585 ₹7,020 Lowest | 588 ₹7,056 | 640 ₹7,680 |
Tender Value
₹43.7 L
EMD Value
₹87,400
Closing Date
9 Jul 2025, 6:00 pmClosed
GE Rangia
GE Rangia C/O 99 APO Rangia
SPL REP TO CONVERSION OF OH LINE TO LT UG CABLE AT CERTAIN UNIT IN TAMULPUR MIL STN UNDER GE RANGIA
2025_MES_715581_1
8933/RNG/E8
Open Tender
Electrical and Maintenance Works
Item Rate
TAMULPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Rangia
₹87,400
Yes
2 Sept 2025
19 Jun 2025
11 Jul 2025
19 Jun 2025
9 Jul 2025
4 Jul 2025
19 Jun 2025 - 27 Jun 2025
Amount
Dismantling ACSR or AAC Conductors from the disturbed span including line spacer, etc., complete all as specified and as directed by Engineer-in-charge.
Dismantling Cross-Arms of Mild Steel Channel or Angle Sections, etc, including Mild Steel Bolts, Nuts, Washers, etc., complete all as specified and as directed by Engineer-in-charge.
Dismantling Insulators like Pin type, Shackle type from existing Street/ Security Light Pole of any description and any size, seggregating Seviceable Insulators and keep in safe custody for re-use, complete all as specified and as directed by Engineer-in-charge.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge.
Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
M&L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as per specified and as directed by Engineer-in-charge. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for.
Supply & Laying Sub-Class B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.
S&F of Galvanised Iron Pipe 40mm bore (dia) ‘light grade’ for protection of UG Cable, laid under Floors or Road Crossing, fixing to Pole with and including Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 09 here-in-above, but for 50mm bore (dia) pipe, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 09 here-in-above, but for 80mm bore (dia) pipe, complete all as specified and as directed by Engineer-in-charge.
M&L for boring holes horizontally under road without damaging the road surface with the help of GI tubing not exc. 80mm bore dia for passing of UG cable, complete all as specified and directed by Engineer-in-charge. NOTE: GI Pipe will be measured and paid separately.
Supply & laying of LT XLPE insulated cable, sheathed, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, 1100 Volts grade, cross-sectional area 300 Sqmm 3½ Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
All as per Item No. 13 here-in-above, but for cross-sectional area 50 Sqmm 3½ Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 13 here-in-above, but for cross-sectional area 16 Sqmm 4 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 13 here-in-above, but for cross-sectional area 16 Sqmm 2 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge.
M&L for Multistranded Copper Conductor flexible cable of 3 Core 1.5 Sq mm size drawn through steel tubular poles for interconnection of cable looping box to street light Fitting, Post Top Lantern & etc., complete all as specified and as directed by Engineer-in-charge.
S&F of Pole Box/Junction Box of size 155 X 210 X 92mm (LxBxH) made out of Polycarbonate material totally enclosed, dust and vermin proof, door pasted with rubber gasket, water tight IP 66/67 protection single leaf shutter in front having proper locking arrangements, including provision of suitable connector for single phase connections loop in and out 10 to 16 Sqmm 4.0 Core aluminium armoured cable branch out 1.5 Sqmm single core PVC insulated copper cable and MCB SP 06 amps- 01 No and mounted on security light pole with suitable clamps (GI Flat iron of 25x3mm), nuts, bolts, complete all as specified and directed by Engineer-in-charge.
S&F of Sheet Metal Enclosure MCB DB TPN, 4 way 415 volt, with rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoing MCBs of any type, complete all as specified and as directed by Engineer-in-charge.
S&F of MCB Triple Pole & Neutral (TPN), 'C' Curve, 20-40 Amps, 415 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth strip of 32x6mm by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 40 mm dia (light grade) and watering pipe 20 mm dia GI pipe (medium grade) and chamber and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia TMT bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs), complete all as specified & testing on completion. NOTE:- (i) Quoted rate includes the cost of 1.5 mtr length GI pipe for protection for GI earth wire and the cost of 7.5 mtr GI earth wire.
Purbanchal Construction Co (BID ID -3350797)
Technolinks (BID ID -3351890)
SONI ENTERPRISE (BID ID -3352278)
M/S Hema construction (BID ID -3351161)
ADITI CONSTRUCTION CO. (BID ID -3350686)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .