Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC KRISHNA SOCIETY OPP TODI XRAY AND DIAG CENTRE MAKUM ROAD TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | ₹24.0 L Quoted ₹24.9 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹26.8 L+₹1.9 L (7.57%)Rejected-Finance | ₹26.8 L+₹1.9 L (7.57%) | L2 | Rejected-Finance Higher |
| 3 | L3₹27.4 L+₹2.5 L (10.0%)Rejected-Finance | ₹27.4 L+₹2.5 L (10.0%) | L3 | Rejected-Finance Higher |
| 4 | L4₹29.0 L+₹4.1 L (16.3%)Rejected-Finance | ₹29.0 L+₹4.1 L (16.3%) | L4 | Rejected-Finance Higher |
| 5 | L5₹29.6 L+₹4.7 L (18.8%)Rejected-Finance | ₹29.6 L+₹4.7 L (18.8%) | L5 | Rejected-Finance Higher |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
29 Jan 2020, 6:00 pmClosed
GE NAMS
GE NAMS KHASA CANTT AMRITSAR
CERTAIN MISC E/M WORKS UNDER AGE E/M AT NAMS
2020_MES_312426_1
GE NAMS - 34 / 19-20
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
NAMS CANTT
Class D
Category b i
8 documents required · 8 mandatory
₹500
Yes
GE NAMS
₹80,000
Yes
17 Mar 2020
7 Jan 2020
30 Jan 2020
7 Jan 2020
29 Jan 2020
20 Jan 2020
Amount
S & F in replacement of V belt (SPA PT 1450) suitable for 20 HP Compressor complete all as specified.
Dismentling and disconnecting of all electrical connections of 2 HP to 20 HP submercible pump, taking out from sewage well and shifting it to work shop for repir and return back from work shop after repair to the site by transport and lowering it to sewage well after testing and commissioning complete all as specifiec and directed.
Dismentling and disconnecting of all electrical connections of 2 HP to 7.5 HP monoblock pump, taking out from sewage plant and shifting it to work shop for repair and return back from work shop after repair to the site by transport and fixing it to sewage plant after testing and commissioning complete all as specifiec and directed.
Material and labour for, opening the burnt motor (Rotor & starter ) rewinding the motor with supper enamelled copper winding as per existing gauge including insulation material cotton tape, varnish, insulation paper, sleeves and dry and backing including replacing of bearing etc and reassembling complete motor complete all as directed of capacity 15 HP to 20 HP. Note : Spare Parts will be measured and paid seperately as supply only as per following Items:-
All as per Item No 5 but capacity 2 HP to 7.5 HP
Supply only in replacement of bearing for submersible motor & Pump for 15 HP to 20 HP
Supply only in replacement of bearing for submersible motor and pump for 2 to 7.50 HP.
Supply only in replacement of SS impeller including oil seal for 2 to 7.5 HP
Supply only in replacement of mechanial oil seal for 15 to 20 HP submersible pump
Supply only in replacement of mechanial oil seal for 2 HP to 7.50 HP submersible pump
Supply and fix in replacement of pressure gauge of suitable rating in pumping & fixing complete all as specified and directed
Supply and fix in replacement timer ET 100, 9 to 30 Second 415 volt complete all as specified and directed
Removing of old paint from inner tank and outer tank complete with the help of blow lamp, metallic surface sand emery paper complete surface clean and body welding. Repair body where required Making good surface with the help of red oxide and ready for paint. Painting complete inner and outer body of STP 0.87 MLD two coat of Red oxide paint and two coat of enamel paint with Air Compressor complete all as specified and directed.
S & F in replacement of 3 pole power contractor 1.5 ML AC 3, 415 Volt, 15HP Auxiliary contact (No-1 + NC-1) complete all as specifiec and directed.
S & F in replacement of 3 pole power contractor 2.5 ML AC 3, 415 Volt, 15HP Auxiliary contact (No-1 + NC-1) complete all as specifiec and directed.
S & F in replacement of thermal over load relay 12.5 to 20 Amp, 415 Volt complete all as specifiec and directed.
S & F in replacement of electronic timmer for star delta starter 415 volt timing range 3 sec to 60 sec complete all as specifiec and directed.
Repair to water circulation pump 02 to 05 HP including disconnecting electrical connection carefully from site and shifting to repair work shop and disconnecting/opening the motor and (stater & rotter carefully and taking out burnt winding wire and Rewinding the motor existing gauge winding wire, insulation sleeve, varnish and replacement of 02 Nos ball bearing. Assembling after repair and shift to site and fitted and connection and testing on load complete all as specifiec and directed.
Repair/Servicing to Air compressor 20 HP model M5175 Make EVEREST TYPE of deffusers coarse bubble/nozzles including opening carefully and cleaning/repair/replacement rotary turn lobe air blower with air filter, silencer, gauger, safety valves, drive bearing and bearing (Gear side) Oil seal drive end long shaft and short shaft, lip seals gear and bearing cover, gasket gear cover and welding grinding & polishing drive rotor shaft assembly as per bearing size. Replacement the recommended oil grade and greasing and assembling and testing on load complete all as specifiec and directed.
Supply and fix in replacement of submersible cable flat 16 Sqmm, 3 core copper cable, 1100 volts conforming IS 694:1990 complete all as specifiec and directed.
M&L for Cleaning of sewage collection sump / Treated water tank of 25000 Gallon capacity including (i) Dewatering with submercible / sludge pump which empty the sump/tank upto base level.(ii) Removing sludge from sump from wall and buttom the sump have to be removed with the help of special sludge pump and remaining dirt which may have hidden in rough slots of the bottom mannualy with brush.(iii) After cleaning the sump apply bleaching powder for disinsfection complete all as specifiec and directed.
All as per Item No 23 above but Capacity 60000 Gallons (Treated water tank )
All as per Item No 23 above Capacity 15000 Gallons ( Sewage collection sump)
Material & Labour for rectification of leckages in DI/MS/HDPE sewage line below soil/on ground at size 50 to 200 mm dia including excavation , returning filling and jointing material such as fittings,lead,spunyarn,rubber Gasket joint,solvant etc complete all as specified and directed.
To attend elect complaint of sewage installation, replacing burnt lugs of cable, to check ato star delta starter, voltmeter, ammpere meter in pump panel changeover switch and make functional if minor repair involves to above equipments complete all as specified and directed.
Supply and fixing in replacement of temper proof electronic energy meter three phase four wire of accuracy class 1.0, as per IS 13779 power factor unity to zero (all power factor lag/or lead ). starting current : 0.40 % lb , current 415 volt,50 Hz with LCD display. The meter shall be able to recording in Kwh/KVAH, MD, current load, V, Amp, Freq, etc burden of voltage circuit shall not exceed 1 VA. The meter shall have IEC 1107 port and shall be DLMS compatible for data reading. The meter should be immune to DC magnetic fields as per the CBIP 304. The meter should record the anti tamper features under the conditions mentioned as reversal of line load terminals, interchanging of phase and neutral wires, drawing of load by disconnecting neutral of meter & out going earth, meter body opening, neutral disturbance with transparent the pilfer proof meter box (PPMB) suitable to house single phase static energy meter. The meter shall be wall mounted type and have ability so as to offer protection of electrical equipment. High grade fire retardant Engineering plastic (Acrylonitrile butadiene styrene /Polycarbonate, with minimum thickness 2.00 mm necessary sealing with lead meter and appropriate size copper lugs and including taking out existing meter and handed over to AGE E/M store Yard.
Supply & fixing in replacement of MCB TPN 40 amps triple pole with neutral, AC 230 volts complete all as specified and directed.
Repair of existing street light of any type or discription, fixed in vertical position with poles/wall including disconnecting the electric connection, removing from pole/wall if required, carrying out minor repairs like disconection of wire/cable,cleaning of carbon on OH line and replacing starter/fuses,etc as required at site to make the items functional and refixing the same at same location or any other location, connecting with electric feeder and testing for functioning engaging sufficient man power and tool and plant etc to ensure safety of light/pole as well as working persons complete all as specified and directed. Note : (i) The un-serviceable items shall be replaced under respective items of relevent schedule as below . (ii) T&P viz tools , ladder any type are provided by the contractor to the electrician party.
Supply only in replacement Open Construction copper ballast (Choke) suitable for 70 watt HPSV/MH light fitting complete all as specified and directed.
Supply only in replacement Ingnitor suitable for 70 to 250 watt HPSV Lamp ISI marked all as spd and directed.
Supply only in replacement HPSV lamp 70 watt, tubular type complete all as specified and directed.
Supply and fixing in replacement thermoplastic polycarbonate cable junction box hinged door type of size 200x160x 98 mm for 3 Phase and Nutral incoming cable, 3 Phase and Nutral outgoing cable and single Phase & Nutral connection for light fitting with aluminiuam bus bar of 25 x 3mm strip, 4 pole, 415 volt with insulator porceline and one MCB sp 6 Amp, 240 Volt and clamp system (screw less), shock proof safe IP-55, weather proof, rust, dust and water proof internally embedded gasket with provision for cable entry through gland alongwith MS clamps and mounting brackets as required at site complete all as specified & directed.
Supply and fix in replacement Timelite distribution boards of Timelite 32 Amps 3 pole 230 Volt astronomical time switch for out door use, weather and vermin proof duly painted with synthetic enamel paint made out of 3.15mm thick CRCA sheet with locking arrangement comprising of one number time switch 24 hours operation Accuracy: quartz time base +/- 1 S per day,suitable for street light operation and duly fixed on pole with clamps / Grouting on ground complete - 1set complete all as specifiec and directed.
Exacavates and relaying cables loops near the poles LT Panels,LT Pole & transformers, cutting the damages/burnt parts of cable and reconnecting its positions complete with thimbles, nut bolts, sleaves all as specified and directed.
M&L for Numbering on Street light/HT/LT Poles by painting of letter Size not less than 5 CM,colur of backgrond and letters including micro prismatic reflective sheet 3 Nos, min 05 cm wide, with adhesive base for dirtectly fixing on HT/LT steel tubular/PCC pole without nail or any other fixing material at suitable height, in Red/White/Yellow colour will as directed.
Supply and fixing in replacement LED type street light fitting pressure die cast aluminium housing(Heat sink)for effective thermal management,sturdinessexcellent corrosion resistant IP 66,Operating Voltage 140-270 Volts, PF (0.95),Assemetric Lens Type-1,No. of LEDs=24 Nos,,Surge Voltage Protection (ref IEC61000-4-13 )of luminaires 90 watt LED 5700K complete fitting complete all as specifiec and directed.
Excavation in trenches not exceeding 1.5m wide & not exceeding 1.5m in depth for and getting out in any of soil complete all as specifiec and directed.
Returning, filling including spreading, leveling, watering and well ramming in layers not exc 25 cm thick all as specified and directed.
Removal of surplus excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified
Supply,laying & fixing double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints,Sockets,Elbows,bends and End caps etc. size 77mm outer dia and 63mm inner dia for LT UG cables all as specified and directed.
All as per Item No 42 of size 90mm outer dia and 76mm inner dia for LT UG cables
All as per Item No 42 of size 110mm outer dia and 94mm inner dia for LT UG cables
Supply and fixing in replacement LED type street light fitting pressure die cast aluminium housing(Heat sink)for effective thermal management,sturdinessexcellent corrosion resistant IP 66,Operating Voltage 140-270 Volts, PF (0.95),Assemetric Lens Type-1,No. of LEDs=24 Nos, Surge Voltage Protection (ref IEC61000-4-13 )of luminaires 60 watt LED 5700K complete fitting.
Material and labour for preparing old painted surface of panel board by cleaning removing of old paint by scratching with wire brush / sand paper etc and including denting of broken / rusted surface and applied two coat of synthetic surface enamel paint by spray painting outside surface of panel as existing colour of panel all as specified and directed.
Material and labour for repairing existing LT Panel doors of front , back and internal sheets complete with new locking arrangement complete all as specified and directed. Note: Any part/spare found defective such as packing, nuts bolts,hinges & (welding machine works) etc shall be repaired/replaced which cost shall be deemed to be included in the unit rate quoted for this item complete all as specifiec and directed.
M & L in replacement for air break gang operated triple pole mechanically operated mounted on HT insulators and galvanised steel frame with operating rod of 25mm bore medium grade GI pipe suitable for operation while standing on ground for current rating 200 Amps suitable for 11000 volt 50 Hz supply including 12 insulator and drop out fuse carrier element all as specified and directed.
Material and labour in replacement for ACSR conductor of any type drawn straight horizontal on HT over head lines on existing poles including binding with insulators weight of conductor shall be measured straight horizontal distance between centre of two adjacent HT/LT poles and calculating weight of conductor of size length by adding 3% extra for sag jointing jumpers etc complete all as specified and directed.
M & L in replacement of LT stay assembly comprising of 7/3.15mm galvanized MS stay wire of reqd length, fixed to poles with and including of FI clamps made out of FI 40x6mm and nuts bolts washers of suitable size MS stay bow 14mm dia galvanized 40cm long MS galvanised stay rod threaded with nut 16mm dia 21 Cm long with washers MS stay plate galvanized 230x30x6mm incl necessry earth work and foundation and PCC all as specified and directed.
S&F in replacement disc type porcelain white, brown or green insulator including one galvanized mild steel spindle, two galvanised iron washers & one galvanised nut for working pressure 11000 volts grade.all as specified and directed.
S&F in replacement pin type porcelain white, brown or green insulator including one galvanized mild steel spindle, two galvanised iron washers & one galvanised nut 150mm height,150mm dia for working pressure 11000 volts grade complete all as specifiec and directed.
S&F in replacement pin type porcelain white, brown or green insulator including one galvanized mild steel spindle, two galvanised iron washers & one galvanised nut 50mm height,65mm dia for working pressure 1100 volts grade complete all as specifiec and directed.
Shifting of transformer from one place to other place within the cantt area any time any capacity complete all as specifiec and directed.
S & F in replacement of MCCB Capacity 36 KA 4 pole 400 Amps adjustable thermal megnate to release type with preader and aluminium lugs all as required at site complete all as specifiec and directed.
-do- but 250 Amp 36 KA
-do- but 315 Amp 36 KA
-do- but 200 Amp 36 KA
-do- but 160 Amp 36 KA
Supply laying & testing in replacement cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty_) LT 1100 volt grade with stranded aluminium conductor of size 185 sqmm 3.5 core complete all as specified and directed.
All as per srl item No 60.00 here-in-before but of size 70 Sqmm 3.5 core.
All as per srl item No 60.00 here-in-before but of size 50 Sqmm 3.5 core.
All as per srl item No 60.00 here-in-before but of size 35 Sqmm 3.5 core.
All as per srl item No 60.00 here-in-before but of size 25 Sqmm 4 core.
All as per srl item No 60.00 here-in-before but of size 16 Sqmm 4 core.
All as per srl item No 60.00 here-in-before but of size 95 Sqmm 3.5 core.
All as per srl item No 60.00 here-in-before but of size 120 Sqmm 3.5 core.
S&F in replacement HT Jumpers wire from top disc insulator to GOD and disc to disc in any length with complete nuts & thimbles all as required at site complete all as specifiec and directed.
M&L for Pre stressed concerete pole in replacement 9 mtr long of cross section of 102mmx 172mm at top and 102mm x 279 mm at bottom class 10 complying with requirement of IS-1678-1978 including painting of poles woth two coats of synthetic paint in black & white step each upto 1.5 mtr high from coping over a coat of primer including numbering of poles as directed complete all as specifiec and directed.
Supply & fixing in replacement of lighting arrestor metel oxide type gap less hreavy duty single pole suitable for rated wsystem on voltage 12 KV and working rated 9 KV normal discharge complete all as specifiec and directed.
S & F in replacement straight through/end termination joint cold shinkable of any size suitable for 3 core 11000 volts XLPE HT UG cable of size 70 Sq mm to 185 Sq mm complete all as specified and directed.
Material & labour for providing 20mm broken stone aggregate including spreading and levelling complete all as specified and directed.
M & L in replacement cross arms bracings supports clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold and hot drilling holes for bolts in any shape or size as indicate or directed and inclusive of one primer coat one under coat and one finishing coat of paint complete all as specifiec and directed.
M & L in replacement galvanised pipe 80mm bore light grade fixed to pole with clamps nuts, bolts and washers or laid under road crossing or fixed to wall complete all as specified and directed.
S & F in replacement HT 11 KV bush rod suitable for indoor / outdoor type 50 to 600 KVA transformer complete with brass stud, 4 nos brass nuts, brass cup and packing gasket complete all as spd and directed.
S & F in replacement LT bush rod suitable for indoor / outdoor type 50 to 600 KVA transformer complete with brass stud, 4 nos brass nuts, brass cup and packing gasket complete all as specifiec and directed.
Supply and toping up of transformer oil including testing as per IS Specification and result not less than 40 KV at site, complete all as specified and directed.
M & L in replacement of out door type aluminuam bus bar chamber feeder box of cap 300 Amp , 3 phase, 4 wire, 415 Volts with porcelain insulator of size 90 x 60 x 45 cm made out of 3.15 mm CRCA Sheet duly painted with two coats of synthetic enameld paint over a red oxide primer and fixed and supported with anlge iron grouted in PCC 1:2:4 upto 0.30 mtr high from ground level complete all as specifiec and directed.
Material & labour for Painting of PCC poles with two coats of synthetic enamel paint in black and white strip 30 cm wide each up to 1.5 mtr height from coping over a coat of primer including Numbering of poles as directed by Engr-in-Charge
Material & labour for painting to mild steel cross arms, bracing, supports, clamps, back plate etc fixed on HT/LT Poles any height with providing two coats of aluminium paint over a coat one coat of red oxide primer complete all as specified and directed. Note:- One HT/LT PCC / Steel pole including steel members fixed thereon shall be considered as 'One Unit'.
Supply & fix in replacement of LED Street Light Luminaire 25 watt 6000K with .high power LED cool white supply voltage 220/240/50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lens complete all as specifiec and directed.
Supply and fixing in replacement bracket made out of GI pipe 50/ 40 mm medium grade 1.2 mtr long made to shape with fixing clamps of MS flat 40x6mm nut bolts etc for street light complete all as specifiec and directed.
Supply and fixing in replacement flood Light Luminaire 120 watt with .high power SMD LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter,pressure die cast LM6 diffusor:injection model polycarbonate,powdre coated in IP 66 Incliding protection over temperature complete all as specifiec and directed.
Supply and fixing in replacement flood Light Luminaire 150 watt with .high power SMD LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter,pressure die cast LM6 diffusor:injection model polycarbonate,powdre coated in IP 66 Incliding protection over temperature complete all as specifiec and directed.
Supply and laying or fixing in replacement 1100 Volts grade heavy duty cable with PVC insulated aluminium standard conductor served with an inner sheathing of PVC tape and over all PVC Sheathed in service connections suspended by insulating hangers not more than 1 meter a part including 4mm suspension wire, one twin core 10 Sqmm cable standard conductor cable flat or circular complete all as specifiec and directed.
Supply & fixing in replacement of integral post top lanterns complete with Black ABC plastic spigot, spun aluminium funnel shape with clear acrylic cover light opening on canopy with baffles and accessories with 10watt LED lamp complete all as specified and directed
Supply and fixing 40mm dia GI light grade tubing with all fittings complete to wall or for garden lights or laid in floors for cable protection including cutting chases and necessary brick work and plaster work to making good the distributed surface complete all as specified and directed.
Material and labour for PCC 1:4:8 type D-2 using 40mm graded broken stone aggregate as in mass concrete in foundation of poles complete all as soecified.
Material and labour for PCC 1:3:6 type D-2 using 20mm graded broken stone aggregate as in mass concrete in foundation of stays complete all as specifiec and directed.
Taking out carefully manually by excavation of existing cable with loops and relaying with DWC pipe the same after repair of cutting the damages / burnt parts of cable and reconnecting its into original positions complete with cable joints all as specified and directed by Engineer-in-Charge. Note:-(i) LT Cable Joint & DWC Pipe will be measured and paid sepearetly. (ii) Rate quoted shall be deemed to be inclusive of necessary earth work.
Material and Labour straight through joint heats shrinkable suitable for upto 50 sqmm LT 3.5 core 1100 volts XLPE cable type complete all as specified and directed.
Material and Labour straight through joint heats shrinkable suitable for 70 sqmm to 120 sqmm LT 3.5 core 1100 volts XLPE cable type complete all as specified and directed.
Supply & fix in replacement of single pointed air termination Aluminium rod, 12 mm dia, 300 mm long complete all as specifiec and directed.
S&F in replacement of aluminium strip 25 mm x 3.15 mm Complete with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as spd and directed
S&F in replacement of GI strip 32 mm x 6 mm buried In ground complete all as specified and directed
Earthing complet with galvanised steel earth plate electrode 60cmx60cmx6mm thich burried directely in ground vertically to adepth not less than 2.25m below ground level with top edge of earth plate at a depth not less than 2.25m below ground level connected with an including GI Strip 32mmx6mm by means of nuts and bolts , check nuts, washers of galvanised iron and thimbles, earth plate surrounded by picked layers of coal, dust and common salt 15cm thick all around top and bottom and watering , excavation, earth work PCC Chamber in cement concrete 1:3:6 type C-2 and RCC Cover in M-20(design mix) complet all as shown in Electric plate No.5 of MES Standerd schedule of rates (Part-I) of 2009 complet all as specified and directed and testig on completion. Note(i) Unit rate shall be included for protection pipe, GI water pipe wire mesh funnel excavation , RCC pit cover , test point, 32mmx6mm GI Strip top of earth plate upto 5m above ground level and if GI Protection is less than 5m no price adjustment shall be made (ii) PCC Pit shall be provided at least 500mm away from the earth pit and extra cost of additional length of water pipes and fittings, junction elbowetc. Shall be deemed in inclusive.
Supply and fixing GI tubing light grade 15 mm dia bore for providing support for the aluminium air termination electrode complete all as specifiec and directed.
Supply and fix in replacement of test point terminal blocks made of gun metal or phosphorus bronze size 75x75x25 mm drill and screwed including three numbers 8 mm dia 25 mm long hexgonal head screw complete all as specified and directed
Supply and fixing in replacement of LED T-8 tube light CRCA Fitting with single side connection polycarbonate LED tube rod 18/20W 4 feet 1 x 18/20 watt box type including rotary type bipin holder and connection with PVC insulalted twin core 23/0.0076 twisted copper cable from ceiling rose to tube light fitting complete all as specified and directed.
CHINAR ENGINEERS AND BUULDERS
v k constructions co
Bharat Builder
tarlok singh contractor
Raman Electric Trading Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .