Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹58.1 L
Closing Date
27 Oct 2026, 4:00 pm
Karnataka Housing Board
LOKESHBABU CG
Proposed Essential works such as Construction of RCC retaining walls, Nala development, Entrance Arch, Access road development, layout upgradation, and additional development works in Donnenahalli KHB Layout at Sy No 35/4 35/6 & Others in Donnenahalli, Tavarekere Hobli, Bengaluru South Taluk, Bengaluru Urban District
KHB/2026-27/OW/WORK_INDENT796
KHB/2026-27/OW/WORK_INDENT796
Open
Other Works
Two Tender Document System(Two Cover)
KHB Central Office Bengaluru
13 documents required · 11 mandatory · 2 optional
Scanned Copy of documentary proof for having executed similar nature of work not less than 50% of tender amount
Scanned copy of Pre-qualification letter issued by Karnataka Housing Board.
As per Tender Documents KW-4 clause 3.3 key & critical equipments available.
Executed in any one Financial year, the minimum quantities of work as mentioned in tender document
Required valid electrical license for executing similar nature of work as per tender document
The Tenderer should have executed similar water supply/sanitary engineering works as per tender document
Income Tax returns & PAN
GST Registration Certificate
To qualify for award of this contract , each tenderer in its name should have in the last five years achieved in at least two financial years a minimum financial turnover (In all classes of civil engineering construction works only)
Scanned copy of latest GST clearance certificate.
Scanned copy of Credit lines/ letter of credit /Bankers certificate for at least 20% of amount put to tender in the current financial year on the name of work put to tender.
Assessed Available Bid Capacity as per tender document
Covering letter.
₹7,500
₹58.1 L
24 Sept 2026
24 Sept 2026
29 Oct 2026
12 Oct 2026
13 Oct 2026
Proposed Essential works such as Construction of RCC retaining walls, Nala development, Entrance Arch, Access road development, layout upgradation, and additional development works in Donnenahalli KHB Layout at Sy No 35/4 35/6 & Others in Donnenahalli, Tavarekere Hobli, Bengaluru South Taluk, Bengaluru Urban District
Drain Works - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricadi...
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS...
Providing and laying in position Reinforced cement
concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50...
Suppiying, fitting and placing TMT SE 550 / 550D Steel Reinforcement Including cost of all materials, machinery labour, cleaning, straghtening, cutting, bending, hooking, laping/welding joints, tying ...
Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5...
Culvert Works - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barrica...
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS...
Providing and laying in position Reinforced cement
concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50...
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The ...
Suppiying, fitting and placing TMT SE 550 / 550D Steel Reinforcement Including cost of all materials, machinery labour, cleaning, straghtening, cutting, bending, hooking, laping/welding joints, tying ...
Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5...
UGD Works - Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construc...
UGD Works - Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construc...
Providing bedding for the pipeline trenches in black cotton and rock reaches including watering and consolidation by punners etc. complete with all lead and lift with: Murrum (BWSSB SOR CODE A1047B- 2...
Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ram ming after watering with a lead upto 50 m , and lift upto 1....
Supplying UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying tr...
Supplying UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying tr...
Supplying UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying tr...
Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying tru...
16.40 Providing and constructing of Machinehole chambers conical in shape at top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround ...
Providing and constructing of Machinehole chambers conical in shape at
top with CC 1:3:6 foundation using 40mm and down size graded metal of
approved quality and with an offset of 0.15m alround the ch...
Water Supply : Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, const...
Earth work excavation for pipeline trenches in all kinds of by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, s...
Providing bedding for the pipeline trenches in black cotton and rock reaches including watering and consolidation by punners etc. complete with all lead and lift with: Murrum (BWSSB SOR CODE A1047B- 2...
Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and ...
Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and ...
Providing house connection with excavation in all types of soils cutting with machine cutter without damaging the other utilities and supplying and laying of MDPE pipe (PE80) -PN 12.5 manufactured in ...
For connection pipe length beyond 2.0 mtrs for every 1 mtr. or part thereof for Housing Connection (Vol-5, pg-22 it-2.21.4)
ROAD WORKS Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading,...
Construction of embankment with approved material deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Table ...
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Compacting original ground supporting Embankment
Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of...
Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading,...
A.Plant mix method Construction of Granular Sub-Base of required grading as
per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers wi...
Wet Mix Macadam (Plant Mix Method)Providing, laying, spreading and compacting graded stoneaggregate to wet mix macadam specification including premixing
the Material with water at OMC in mechanical mi...
Prime Coat over WMM/WBM
Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0....
Providing and laying Dense Graded Bituminous Macadam with 120 TPH capacity HMP batch type using crushed aggregates of specified grading, premixed with bituminous binder VG-40, @ 4.5 per cent by weigh...
Tack coat on Bituminous surface
Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.20 kg/m2 on the prepared bituminous surface cleaned w...
Providing and laying Semi Dense Bituminous Concrete with 40/60 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 5% by weight ...
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ra...
Construction of M40 Grade un-reinforced, dowel jointed,
plain cement concrete pavement over a prepared sub base in
recommended proportions, coarse and fine aggregate conforming
to IS 383:2016, maximum...
Longitudinal Bars(Tie Bars) 12mm Dia 640mm C/C both LHS & RHS 18 mtrs wide road-21 Tie Bars Vol-1, pg-18 it-2.11(h)
Transverse Bars (Dowel Bars) 32mm Dia 300mm C/C both LHS & RHS 18 mtrs wide road-21 Dowel Bars
Groove sealant Vol-3, pg-163, it-17-C5 morth602.6.3
Dismantling of Flexible pavements and disposal of dismantled
materials and stacking serviceable and unserviceable material seperately S.NO-2.18(202, IIB) pgno-12 SR 23-24 VOL-3
Dismantling of Flexible pavements and disposal of dismantled
materials and stacking serviceable and unserviceable material seperately S.NO-2.18(202, IIB) pgno-12 SR 23-24 VOL-3
Cable Duct :Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricadin...
Cable Duct Across the Road
Providing and laying of a reinforced cement concrete pipe
duct, 300 mm dia, across the road (new construction),
extending from drain to drain in cuts and toe of slope to t...
Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plaster...
RCC Nala :Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, ...
Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour wit...
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS...
ReFilling available excavated earth ( excluding rock ) in sides of foundations upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with lead...
Providing and laying in position reinforced cement concrete of design Mix M30 with OPC @ 340kgs, with 20mm and down size graded granite metal coarse aggregates @0.70cum and fine aggregtes @ 0.47cum, w...
KSRB 4.9.2 : Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding ...
Bridge : Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, c...
Earth work excavation for pipeline trenches upto 600mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, danger light...
Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour wit...
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechaniqal mix plant carriage ' of mixed Mater...
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS...
Providing and laying in position reinforced cement concrete of design Mix M30 with OPC @ 340kgs, with 20mm and down size graded granite metal coarse aggregates @0.70cum and fine aggregtes @ 0.47cum, w...
Providing and laying in position reinforced cement concrete of design Mix M30 with OPC @ 340kgs, with 20mm and down size graded granite metal coarse aggregates @0.70cum and fine aggregtes @ 0.47cum, w...
Providing and laying vibrated M30 design mix for RCC works (excluding cost of reinforcement) with 20mm and down size of approved gradation, hard broken granite, trap, basalt or with any other approved...
ReFilling available excavated earth ( excluding rock ) in sides of foundations upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with lead...
KSRB 4.9.2 : Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding ...
Retaining Wall:Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricad...
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS...
Providing and laying in position reinforced cement concrete of design Mix M30 with OPC @ 340kgs, with 20mm and down size graded granite metal coarse aggregates @0.70cum and fine aggregtes @ 0.47cum, w...
Suppiying, fitting and placing TMT SE 550 / 550D Steel Reinforcement Including cost of all materials, machinery labour, cleaning, straghtening, cutting, bending, hooking, laping/welding joints, tying ...
Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5...
Pond:Earth work excavation by manual means for drains, canals, waste weir, draft,approach channels, key trenches, foundation of Buildings & bridges and such
simillar works in all kinds of soils, as pe...
Pond:Earth work excavation by manual means for drains, canals, waste weir, draft,approach channels, key trenches, foundation of Buildings & bridges and such
simillar works in all kinds of soils, as pe...
Pond:Earth work excavation by manual means for drains, canals, waste weir, draft,approach channels, key trenches, foundation of Buildings & bridges and such
simillar works in all kinds of soils, as pe...
Electrical work;Part A: Running Single Circuit 11 kV, 3 Phase Power Line On 9 Mtr Supports With An Average Span Of 40 Mtr Using RABBIT ACSR Conductor. RCC Pole - 9 Mtr Long, 1...
PSCC Pole - 9 Mtr Long, 200 Kg WL
11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL
11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for PSCC Pole - 9 Mtr Long, 200 Kg WL
DP Structure with RCC Pole - 9 Mtr Long, 145 Kg WL
11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod)
11 kV, 45 KN Polymeric Insulator
Guy Set Complete with No. 15 Strain Insulator
Rabbit ACSR Conductor
PG Clamps for Rabbit Conductor
Spiral Earth Electrode
EG Stirrups with GI wire lacingSet/2
Caution/Danger Board
Anti Climbing Device (12 Mtr GI Barbed Wire)
RCC Pole - 9 Mtr Long, 145 Kg WL
PSCC Pole - 9 Mtr Long, 200 Kg WL
11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL
11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for PSCC Pole - 9 Mtr Long, 200 Kg WL
DP Structure with RCC Pole - 9 Mtr Long, 145 Kg WL
Guy Set Complete with No. 15 Strain Insulator
Rabbit ACSR Conductor
Spiral Earth Electrode
EG Stirrups with GI wire lacing Set/2
Guy concreting with Boulders, Mud and Sand
Caution/Danger Board
Anti Climbing Device (12 Mtr GI Barbed Wire)
PART B: Running LT, 3 Phase 5 Wire for Power Line on 9 Mtr Supports Using RABBIT ACSR Conductor for Phase, Neutral and WEASEL Conductor for Street Light with an Average Spa...
PSCC Pole - 9 Mtr Long, 200 Kg WL (for Intermediate Pole)
LT 4 Pin Cross Arm with clamps, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL
LT 2 Pin Cross Arm with clamps, bolts, nuts for RCC Pole
- 9 Mtr Long, 145 Kg WL
LT 2 Pin Cross Arm with clamps, bolts, nuts for PSCC Pole - 9 Mtr Long, 200 Kg WL
1.1 kV Pin Insulator with GI Pin
No. 8 Strain Insulator
Guy Set Complete with No. 8 Strain Insulator
Rabbit ACSR Conductor
Spiral Earth Electrode
Sheet Metal/Deep Drawn Street Lighting Metering Box with Automatic Control Swith, Contactors with Single Phase 5-30 Amps Meter & 50/5A CT including wiring
PVC Pipe 40 mm Dia
(Extracted from Vol-6, PWD Ele SR Sl No. 4)
PVC Insulated wire 25 Sqmm Single Core Multi stranded
Anti Climbing Device (12 Mtr GI Barbed Wire)
RCC Pole - 9 Mtr Long, 145 Kg WL (for Deadend, Anchor points)
PSCC Pole - 9 Mtr Long, 200 Kg WL (for Intermediate Pole)
LT 4 Pin Cross Arm with clamps, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL
LT 2 Pin Cross Arm with clamps, bolts, nuts for RCC Pole
- 9 Mtr Long, 145 Kg WL
LT 2 Pin Cross Arm with clamps, bolts, nuts for PSCC Pole - 9 Mtr Long, 200 Kg WL
Guy Set Complete with No. 8 Strain Insulator
Rabbit ACSR Conductor
Spiral Earth Electrode
Guy concreting with Boulders, Mud and Sand
Sheet Metal/Deep Drawn Street Lighting Metering Box with Automatic Control Swith, Contactors with Single Phase 5-30 Amps Meter & 50/5A CT including wiring
Anti Climbing Device (12 Mtr GI Barbed Wire)
PART C:Providing 2 Pole Structrue at the Tapping Point Using RCC Pole DP Structure using RCC Pole - 9 Mtr Long, 145 Kg WL (Including Cost of Pole
11 kV, 45 KN Polymeric Insulator
Guy Set Complete with No. 15 Strain Insulator
Spiral Earth Electrode
Caution/Danger Board
Anti Climbing Device (12 Mtr GI Barbed Wire)
11 kV, 400 Amps Double Break GOS
H-Frame for mounting GOS
DOLO Cut Out Set/3
DP Structure using RCC Pole - 9 Mtr Long, 145 Kg WL (Including Cost of Pole
Guy Set Complete with No. 15 Strain Insulator
Spiral Earth Electrode
Guy concreting with Boulders, Mud and Sand
Caution/Danger Board
Anti Climbing Device (12 Mtr GI Barbed Wire)
11 kV, 400 Amps Double Break GOS
H-Frame for mounting GOS
DOLO Cut Out Set/3
PART D:Erection of 3 Phase, 11kV/433V, 250 kVA 4/5 Star Rated Distribution Transformer Centre Using 9 Mtr RCC Pole DPTC. DP Transformer Structure using RCC Pole - 9 Mtr Long, 145 ...
11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod)
11 kV, 45 KN Polymeric Insulator
Guy Set Complete with No. 15 Strain Insulator
Earthing materials pipe type for grounding (Single Electrode with accessories)
Caution/Danger Board
Anti Climbing Device (12 Mtr GI Barbed Wire)
Guy wire 7/10 SWG
11 kV Lightning Arrester, Metal Oxide 10 kV, 5 kA Polymetic Type with ground disconnector Set/3
LT Distribution box for 250 kVA with MCCB
Al Lead Wire - 240 Sqmm
Heavy Duty Long Barrel Copper Lug - 240 Sqmm
PG Clamp - Rabbit to 240 Sqmm
Spacer for DTC Wiring
Fish Plate with necessary Clamps, bolts & nuts etc complete (Galvanised)
LT Metering box with CTs and necessary wiring for housing ETV Meter (Please see CDS - 39)
LT Electronic Tri-Vector Meter 5 Amps, - 0.5/1.0 Accuracy Class
11 kV, Solid Core Type HG Fuse Unit Set/3
11 kV, 200 Amps, Single Break GOS
DP Transformer Structure using RCC Pole - 9 Mtr Long, 145 Kg WL
Guy Set Complete with No. 15 Strain Insulator
11kV/433V, 250 kVA, 3 Phase, 50 Cys Distribution Transformer BEE - 4 Star Rated with oil
11kV/433V, 250 kVA, 3 Phase, 50 Cys Distribution Transformer BEE - 5 Star Rated with oil
Earthing materials pipe type for grounding (Single Electrode with accessories)
Caution/Danger Board
Anti Climbing Device (12 Mtr GI Barbed Wire)
Guy concreting with Boulders, Mud and Sand
11 kV Lightning Arrester, Metal Oxide 10 kV, 5 kA Polymetic Type with ground disconnector Set/3
LT Distribution box for 250 kVA with MCCB
LT Wiring (From DTC to LT Line via Metering Box & LT Protection Kit) DOUBLE CIRCUIT
LT Metering box with CTs and necessary wiring for housing ETV Meter (Please see CDS - 39)
LT Electronic Tri-Vector Meter 5 Amps, - 0.5/1.0 Accuracy Class
11 kV, Solid Core Type HG Fuse Unit Set/3
11 kV, 200 Amps, Single Break GOS
PART E:Fabrication, Supplying, Erection, Testing and Commissioning of..... ms long Polygon high mast with Single/Multiple telescopic sections having, (minimum overlap distance of 1.5 times of top sect...
Supply of LED Streetlight luminaire with pressure die cast aluminiurn housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded poly...
Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete Single Arm Bracket with 2000mm Standar...
Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete Single Arm Bracket with 1500mm Standar...
PART F:Providing Compact RMU 11 kV Class SF6/VCB Type (1 OD) -RMU 1 OD, 350 MVA, 630 Amps
Bed Concreting with CC 1:2:4 [M-15] Using 20mm Nominal size graded crushed coarse aggregates
(Extracted from Item No. 2.1.6 of KPWD SR 2023-24, Volume - 1)
Foundation with CC 1:2:4 [M-15] Using 20mm Nominal size graded crushed coarse aggregates (Extracted from Item No. 2.1.6 of KPWD SR 2023-24, Volume - 1)
Providing Reinforecement TMT Fe 550/550 D
(Extracted from SL No. 69 of KPWD SR 2023-24, Volume - 1)
Providing Plinth with CC 1:2:4 on the Stone Masonary [M-15] Using 20mm Nominal size graded crushed coarse aggregates (Extracted from Item No. 2.1.6 of KPWD SR 2023-24, Volume - 1)
Construction of Stone Masonary (Extracted from Sl No. 5.4 of KPWD SR 2023-24, Volume - 3)
Supplying of Frame of MS Channel 100x50 mm and MS angle 40x40x5 mm welding etc., complete.
(Extracted from SL No. 69 of KPWD SR 2023-24, Volume - 1)
Rod type earthing with 40 mm Dia, 3 Mtr long MS rod as per specification & drawing including digging of pit & fixing
Lettering the RMU with enamel paint and also writing single line diagram of each panel, caution Board, Danger Board etc., including cost of Paint, Brush etc.,
Earth Excavation for RMU Foundation depositing of earth on bank up to a lead of 50 Mtr and with a lift up to 1.5 Mtr
Labour charges for Fixing foundation frame of MS channel 100x50 mm and MS angle 40x40x5 mm welding, fixing in concrete, aligning the RMU on foundation bed, assembly of units, connect...
PART G: 11 kV, 3.5 x240 Sqmm XLPE UG Cable Using Conventional Laying with Excavation in Soil- 11 kV, 3x400 Sqmm XLPE UG Cable
Straight Through Jointing Kits HS Type suitable for 3x400 Sqmm Cable
Cable Termination Kit Outdoor HS Type Suitable for 3x400 Sqmm Cable
Cable Termination Kit Indoor HS Type Suitable for 3x400 Sqmm Cable
Cable Covering Tiles 250x125x40 mm or 125x125x40 mm
Artificial/Manufacture Sand
(Extracted from Vol-1, PWD SR Sl No. 62)
RCC Hume Pipe, 2000mm Long, 150mm Dia
Collars for RCC Hume Pipe
GI Pipe, 150 mm Dia for drain crossing, cable raising etc.,
(Extracted from Vol-5, BWSSB SR Item No. 177)
Route and Joint indicating stones
Cable trench excavation, 1000x0.6x1=600, Ordinary soil
(Extracted from Vol-1, PWD SR Sl No. 1.17.1)
Laying of cable in trench
Refilling and consolidation
(Extracted from Vol-1, PWD SR Sl No. 1.10)
Making of straight through joint
Making of cable termination
Covering the cable with tile
Spreading Sand and forming with Sand round the cable
Laying of RCC Hume pipe
Laying of GI Pipe
Laying of Route and Joint indicating stone
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT additional development to S and S Donnenahalli.docx
Others - NIT • 1.57 MB
kw-4 Additional development to S and S Donnenahalli.docx
Tender Document • 1.66 MB
Drawings.zip
Others - DRAWINGS • 8.62 MB
Section-7-Specification.docx
Instructions to Tenderers • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .