Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance CW 545 SANJAY GANDHI TRANSPORT NAGAR NEW DELHI 110042 | NORTH | DELHI | 110042 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance 638 GROUND FLOOR WEST GURU ANGAD NAGAR LAXMI NAGAR LAXMI NAGAR EAST DELHI DELHI 110092 UDYAM DL 02 0031392 | EAST DELHI | DELHI | 110092 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹12,900
Closing Date
13 Oct 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (EM) M-1
Chitra Vihar Booster Pumping Station Laxmi Nagar Delhi-110092
Renovation of Charging Pump with allied work at Gazipur BPS.
2023_DJB_248474_13
NIT No-12 EE (EM) M-I/ (23-24)
Open Tender
Electrical Works
Works
30 days
Chitra Vihar Booster Pumping Station Laxmi Nagar D
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
A/c.50448339804
₹12,900
6 Nov 2023
7 Oct 2023
13 Oct 2023
7 Oct 2023
13 Oct 2023
7 Oct 2023
Dismantling of existing vacuum pump, motor, starter and pipes, cable etc. As per site requirement.
Providing and fixing GI pipes 50 MM dia nominal bore complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal Work- Exposed on wall. Make: Jindal/TATA/SAIL/AS DJB Approved. DSR No. 18.10.6
Providing and fixing GI pipes 40 MM dia nominal bore complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal Work- Exposed on wall. Make : Jindal/TATA/SAIL/AS DJB Approved. DSR 18.10.5
Providing and fixing GI pipes 25 MM dia nominal bore complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal Work- Exposed on wall. Make : Jindal/TATA/SAIL/AS DJB Approved. DSR No. 18.10.3
Providing and fixing GI pipes 20 MM dia nominal bore complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal Work- Exposed on wall. Make : Jindal/TATA/SAIL/AS DJB Approved. DSR No. 18.10.2
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work): 40 mm nominal bore. DSR
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work): 50 mm nominal bore. DSR
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work): 25 mm nominal bore. DSR
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work. DSR 20 mm diameter pipe. DSR No. 18.38.2
25 mm diameter pipe DSR No. 18.38.3
40 mm diameter pipe DSR No. 18.38.5
50 mm diameter pipe DSR No. 18.38.6
Laying of PVC cable 4CX10 Sq. MM as per site condition. Clamped with 1 mM thick saddle. DSR
Supply of VACUUM PUMP type DV-50, size 50 x 50 mm, standard fitted with bronze rotor (Br. IS. 318, Gr. 2) capable of discharging maximum 2730 LPM of free air and can create maximum vacuum of 630 mm of Hg. directly coupled to 7.5 KW / 10 HP / 1440 RPM, totally enclosed fan cooled, horizontal foot mounted, continuous rated, AC 3 Phase, 415 volts ± 10%, 50 Hz. ± 5%, CV ± 10% motor, S1 duty, 40º C amb., class F Insulation, IP-55 Protection motor in frame K 132L/equivalent. Make: Kirloskar/ABB/Siemens/BHEL/Jyoti Ltd./Crompton/DJB Approved.
Supplying of coupling and coupling guard for the the above pump.
Supply of M.S. Channel base frame suitable for the above pump.
Providing of Four Pole Main Switch 63 A, 415 Volts AC, 50Hz, heavy duty double break fuse inclusive , surface mounting type, house in sheet steel enclosure with side handle operation and have front access left opening doors interlocking to prevent opening when the switch is in ON position for 10 HP Motor Starter. Make: Havells/L&T/ GE/C&S/As DJB Approved.
Providing of 7.5 KW/10 HP 415V DOL Starter with IP 65 compact plastic enclosure with double insulation. Thermal Overload relay suitable for 10 HP motor as above. Make: Havells/L&T/C&S/As DJB Approved.
Providing of PVC cable 4CX10 Sq. MM copper flexible cable. Make : Gloster/Grandlay/ICC/ICL/CCI/Universal.
Providing of copper tube heavy duty with ferrule, brass nut, nipple socket complete in all respect.
Providing and fixing Gun metal gate valve 50 MM nominal bore, Pressure class 1, with screwed end Make : Sant/Parth/As DJB Approved.
Providing and fixing Gun metal gate valve 40 MM nominal bore, Pressure class 1, with screwed end Make : Sant/Parth/As DJB Approved.
Providing and fixing Gun metal gate valve 25 MM nominal bore, Pressure class 1, with screwed end Make : Sant/Parth/As DJB Approved.
Providing and fixing Gun metal gate valve 20 MM nominal bore, Pressure class 1, with screwed end Make : Sant/Parth/As DJB Approved.
Providing and fixing of PVC water storage tank 100 Litre with MS Stand. Make : Sintex/As DJb Approved.
Providing and fixing Ball valve 20 MM nominal bore approved quality (screwed end) Make : Sant/Parth.
Providing of vacuum gauge of 760 hg to 150 mm size approx. As per site requirement. Make : H.Guru/General instrument/As DJB Approved.
Installation, testing and commissioning of vacuum pump, motor, main switch, starter, coupling and coupling guard and base frame etc. etc. At site including making of connection & foundation of charging pump tools and tackles to complete the job in all respect.
RUDRA ALLIANCE
SAI TRADING CORPORATION
Devraj Enterprises
Gupta Brothers
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .