Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC 0 AJAY KUMAR 85 HASTAM HASTAM BANDA UTTAR PRADESH 210001 HASTAM BANDA UTTAR PRADESH 210001 UDYAM UP 13 0007628 | BANDA | UTTAR PRADESH | 210001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹10.6 L+₹69,186.80 (6.99%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹10.8 L+₹88,900.80 (8.98%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹11.0 L+₹1.1 L (11.0%)Rejected-AOC | L4 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
12 Sept 2020, 6:00 pmClosed
G E ROORKEE
G E ROORKEE
REPAIR MAINT OF INTERNAL WIRING INCL SUB MAIN AND CONNECTED ITEMS FOR OTM ACCN AND MD ACCN AT SAHARANPUR UNDER GE ROORKEE
2020_MES_366124_2
8391/945/E8
Open Tender
Civil Works
Item Rate
180 days
SAHARANPUR
AS PER NIT
6 documents required · 6 mandatory
₹500
G E ROORKEE
₹30,000
Yes
16 Nov 2020
24 Aug 2020
14 Sept 2020
24 Aug 2020
12 Sept 2020
28 Aug 2020
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete incl fixtures and fittings suze as swithes, ceiling rose, pendant, regulator, ssockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (Credit for above items should be as per conditions separately) and making good disturbed surfaces of walls, floors etc
M & L for Point wiring in repair with PVC insulated PVC unsheathed electric (FRLS) cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall (cutting except on ceiling for fan point only, on ceiling instead of pvc conduit surface casing caping will be used) & 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including sunk in pressed steel terminal boxes (normal and moduler type) of 1.6 mm thick (duly painted with two coats of black bituminous paint over a coat of red oxide primer in and out sides) with and including plastic laminated bakelite sheet cover of hylam board of 2.8 mm thick including cutting holes for switches, sockets, regulators etc as per requirement including fixing with machine screw, washer etc for the following and Make of wire- Grandlay/Havells /polycab, Make of the conduit : Kalings/AKG/Polycab
(a) One light point controlled by one one way switch
(b) One fan point controlled by one one way switch
(c) One bell/buzzer point controlled by one push button
(d) One 3/5 pin socket outlet 5 Amp on the same board with other swithes.
(e) One 3/5 pin 5 Amps socket outlet on indepandant board.
All as per item No 2 above here in before but wiring in existing conduit for the following :-
(a) One light point controlled by one one way switch
(b) One fan point controlled by one one way switch and fan regulator
(c) One bell/buzzer point controlled by one push button complete
(d) One 3/5 pin 5 Amp socket outlet point controlled by one switch on same board.
(e) One 3/5 pin 5 Amps socket outlet on indepandant board.
All as per item No 2 above here in but with 2.5 Sqmm (nominal area) FRLS cable PVC for the 15 Amp 3/5 pin socket power point including 1.5 Sqmm copper conductor green as colour for earth contineuity all as specified.
All as per item No 2 above here in but in existing conduit with 2.5 Sqmm (nominal area) FRLS cable PVC for the 15 Amp 3/5 pin socket power point including 1.5 Sqmm copper conductor green as colour for earth contineuity all as specified.
M&L for point wiring complete with PVC insulated and unsheathed, flame retardant low smoke (FRLS) 1100 volt grade electric cable of 1.5 sqmm (nominal area) with stranded copper conductor single core in and including rigid PVC surface conduit not less than 19 mm dia, clip, with suitable MS terminal boxes (not less than 1.0 mm thick )and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including earth dolly with 3 mm thick plastic laminated sheet top cover of approved colours including 1.50 sqmm green stranded copper conductor as continuous earth wire with all accessories including lugs required, complete all as specified and as directed and Make of Cable- Grandlay/Havells /polycab
(a) One light point controlled by one switch
(b) one fan point controlled by one switch & regulator.
(c) One 3/5 pin 5 Amp socket outlet point controlled by one switch on independent board.
(d) One 3/5 pin 5 Amp socket outlet point controlled by one switch on same board.
Description all as per item No 6 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed flame retardant low smoke (FRLS) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed and Make of Cable- Grandlay/Havells /polycab
Taking down sub main wiring and supply and fixing of Sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLS) cable of size 4.0 sqmm LT, 1100V grade, down trhough and incl adequate sizes PVC non metallic conduit of 20mm/approprite dia with accessories and fittings and one run of 2.5 sq mm single core multi stranded copper conductor cable as earth continuity conductor. Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 20mm/approprite dia shall be measured as one run length, Cable required for connection to DBs shall deemed to be incl and shall not be measured separately. Earth wire shall run inside the conduit pipe (Note :- Extra length of cable required for connection to MCBs shall deemed to be included in unit rate.) Make of Cable- Grandlay/Havells /polycab, Make of PVC conduit - Kalinga/AKG/Polycab
All as per item No-6 here in before but 6.00 Sqmm copper conductor and 4.0 Sqmm as earth continuity conductor complete all as specified.
S&F in replacement switch piano flush type polycarbonate single pole one way 5 Amps.
S&F in replacement switch piano flush type polycarbonate single pole one way 15 Amps.
S&F in replacement socket outlet polycarbonate 2 in 1, 3 pin 5 Amps flush type.
S&F in replacement socket outlet polycarbonate 2 in 1, 3 pin 5/15 Amps flush type.
S&F in replacement bell push flush type 5 Amps
S&F in replacement Ceiling rose 3 phase/PVC/polycarbonate, insulated body.
S&F in replacement steped type electrronic fan regulator flush type all as specified.
S&F in replacement Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with 9 watt LED bulb PAG series B-22 base complete all as specified and directed. Bulb Make : Syska/Crompton/Phillips, Holder Make : Cona/Anchor/Havells
S&F in replacement Modular switch 1 way 6A, 1 module complete, Make : Legrand or equivalent
S&F in replacement Modular switch 1 way 10A, 1 module complete Make : Legrand or equivalent
S&F in replacement Modular switch 1 way 16A, 1 module complete, Make : Legrand or equivalent
S&F in replacement Modular Bell push 6A 1 module complete, Make : Legrand or equivalent
S&F in replacement Socket, 6A - 2/3 pin combined 2 module complete, Make : Legrand or equivalent
S&F in replacement Socket, 6A/16A - 2/3 pin combined 2 module complete, Make : Legrand or equivalent
S&F in replacement Fan step regulator, 120W - 2 module complete, Make : Legrand or equivalent
S&F in replacement White cover plate with frame, 1 module complete, Make : Legrand or equivalent
S&F in replacement White cover plate with frame, 2 module complete, Make : Legrand or equivalent
S&F in replacement White cover plate with frame, 3 module complete, Make : Legrand or equivalent
S&F in replacement White cover plate with frame, 4 module complete, Make : Legrand or equivalent
S&F in replacement White cover plate with frame, 6 module complete, Make : Legrand or equivalent
S&F in replacement White cover plate with frame, 8 module complete, Make : Legrand or equivalent
S&F in replacement electric bell ding dong single phase, AC 230 volts complete all as specified, Make :Cona/Anchor or equivalent
Supply and fixing in repair Wall light fixture lantern made up of polycarbonate suitable for 9 watt LED bulb complete with 9 watt LED bulb including connection with all necessary accessories complete all as specified and directed by Engr-In-Charge. Make:- Havells Cat No.LHDLO2160099 or equivalant Bajaj/Philips/Havells/crompton.
S&F LED Tube light fitting 1x18/20 Watt surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser & integrated electronic driver complete with all accessories internally prewired and incl connecting up three core single wire complete all as spd and directed . Make : SYSKA, SSK-RA1801, Havells/Phillips/Crompton/Bajaj or equivalent
Taking down carefully UNSV main switchs, DBs including MCBs etc complete of any size and capacity .
S&F double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts 200 amps rated busbar 12 way complete all as specified and directed by Engr-in-charge. MAKE-LEGRAND / SCHNEIDER /SEIMENS
S&F double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts 200 amps rated busbar 8 way complete all as specified and directed by Engr-in-charge. MAKE-LEGRAND / SCHNEIDER /SEIMENS
S&F double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts 200 amps rated busbar 4 way complete all as specified and directed by Engr-in-charge. MAKE-LEGRAND / SCHNEIDER /SEIMENS
S&F for Distribution board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof TPN 4 way IP 43 (double door) with 200 Amps rated copper bus bar neutral bar ,earth bar ,triple pole and neutral 415volts ,flush to wall complete all as specified and directed. .MAKE-LEGRAND / SCHNEIDER /SEIMENS
M&L for MCB single pole,6 to 32 Amp 240 volt B curve 10 KA, IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed MAKE-LEGRAND / SCHNEIDER /HAVELLS/HPL
S&F Miniature circuit breakers ISI marked 240 Volt, 50 Hz, double pole 40 Amps, breaking capacity 10 KA. MAKE-LEGRAND / SCHNEIDER /SEIMENS
S&F single pole and neutral enclouser with a two pin and earth plug and socket complete with one single pole MCB of rating 20 Amps 240 volt grade MAKE-LEGRAND / SCHNEIDER /SEIMENS
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connecting to main switch or switch board complete and incl PCC masonry pit of 300x300x300mm interier diamentions in PCC 1:2:4 type B1 RCC cover with GI frame, charcoal dust and common salt 15cm in layers all round the earth plate, 20mm dia GI watering pipe, a funnel with wire mesh should be provided on top of watering pipe complete all as specified as per electric plate No 3of SSR 2009 including testing after completion.
Taking down carefully existing UNSV Service cable of any size and capacity
Supply and fixing 1100 volt grade heavy duty cable PVC insulated solid aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connectiuons suspended by insulating hangers not more than 1 meter apart including 4 mm dia suspension wire, one twin core cable flat or circular of size 6 Sqmm all as specified. Make:- Plaza /Havells/Grandlay
Supply and fixing 1100 volt grade heavy duty cable PVC insulated solid aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connectiuons suspended by insulating hangers not more than 1 meter apart including 4 mm dia suspension wire, one twin core cable flat or circular of size 10 Sqmm all as specified. Make:- Plaza /Havells/Grandlay
Taking out carefully existing UNSV UG cable of any size and capacity
S&L XLPE insulated armoured heavy duty electric cable with stranded aluminum conductor 1100 volt grade cross sectional area 16 Sqmm and 2 core all as specified and directed Make:- Polycab/Havells/Grandlay
S&L XLPE insulated armoured heavy duty electric cable with stranded aluminum conductor 1100 volt grade cross sectional area 25 Sqmm and 3.5 core all as specified and directed Make:- Polycab/Havells/Grandlay
S&L XLPE insulated armoured heavy duty electric cable with stranded aluminum conductor 1100 volt grade cross sectional area 35 Sqmm and 3.5 core all as specified and directed Make:- Polycab/Havells/Grandlay
Dismantling of house service bracket of an type and Supply and fixing house service bracket (hook type) complete with 3.0 mtrs long GI pipe 40 mm dia medium grade two nos 90 degree bends, MS hook and stay or guy complete all as specified
M&L for laying GI tubing light grade 40 mm dia with all fittings for cable protection including GI clamps nut bolts and washer etc all as specified.
M & L for Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete.
M & L for Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete.
M & L for Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete.
M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable all as specified and directed by Engr - in - Charge. (Note:- Punning thickness shall be measured)
Material and labour for Brick protection with sub class ‘B’ bricks old size, laid dry, flat over cable, perpendicular across the cable in trenches complete all as specified and as directed.
S&F bulk head fittings IP-65, surface mounted comprising LED luminaire 10W of high brightness Make : Havells : Cat part No. RUGBYNEONFT10WLED 860SSYMTOPC or equivalent Phillips Cat part WT202W LED6S NW PSU S2PC
Supply and fixing in replacement of building security lights with new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic driver type street light fitting 25 watt capacity LED and including all accessories duly pre-wired, fixing on existing bracket with nut, bolts & washers as required at site for fixing of street light on LT pole/ wall complete including taking old street light fitting any type and description complete all as specified and directed. Make: Havells, Cat Part No ENDURAPEARLSL25WLED757SASYTOPCMP of Havells or equivalent in C&S/Phillips/Crompton/Bajaj/Syska
S&F in replacement of Gate lights/post top light with 15 Watt LED light as light source, IP-65, made of spun aluminium landscape luminaire suitable for fixing on 40/50 mm GI pipe on the gate post including connection with all necessary accesssories complete all as specified and directed by Engr-In-Charge. Make : Havells Coral (Opal) Cat part No.CORALMINIPT15WLED757PSYMTOPC or equivalent in Phillips/cropmpton/C&S/Bajaj
S&F LED Tube light fitting 1x6 Watt surface and wall mounted LED batten, with polycarbonate housing & integrated electronic driver complete with all accessories internally prewired and incl connecting up three core single wire complete all as spd and directed . Make :SYSKA: SSK-T-5-6W or equivalent Phillips/Crompton/Havells/C&S
S&F in replacement of 2'x2', 36 Watt LED ceiling light with highly efficeint light-smoothing optics to deliver superior illumination and energy.Make : Crompton Cat type: LPCL-36-CDL(2x2)/Havells/Phillips/Sysks or equivalent
Supply and fixing in repair in and out Wall light fixture made up of polycarbonate suitable for 0.5 watt LED bulb in green and red colour, complete including connection with all necessary accessories complete all as specified and directed by Engr-In-Charge. Make:- Havells or equivalant Bajaj/Philips.
Labour only for attending and repairing day to day complaints (twice in a week) of internal electrification and repairing in situ by skilled electrician alongwith a helper and making functional all malfunctioned points i.e. fixing necessary electric fittings (switch, socket, holder, Tube light, bell, regulator etc) complete all as specified and directed at site. (Note : - Point wiring will be measured and paid separately under appropriate item.) Note :- (a) The trade men shall be equipped with all necessary Electrician tool kit. (b) The trade men shall report at complaint cell at 0930 Hrs. (c) Old Unsv items retreived against new shall be deposited to MES store yard.
NAQLI LAL SHARMA AND ARUN SHARMA
SHRI RAM ENTERPRISES
janta tradrers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .