Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹74.2 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹78.9 L+₹4.7 L (6.32%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹94.8 L+₹20.5 L (27.6%)Admitted-Finance 405 406 FF NILKANTH PALACE OPP KARMA SHRSTHAN TOWER 100 FT ROAD JODHPUR SATELLITE AHMEDABAD GUJARAT 380015 | AHMADABAD | GUJARAT | 380015 | L3 | Admitted-Finance | |
| 4 | L4₹1.0 Cr+₹27.3 L (36.7%)Admitted-Finance 10TH FLOOR UNIT 2 TECHNIPLEX 2 VEER SAVARKAR FLYOVER S V ROAD GOREGOAN WEST MUMBAI 400 062 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400062 | L4 | Admitted-Finance | |
| 5 | L5₹1.0 Cr+₹29.8 L (40.2%)Admitted-Finance A 99 SECTOR 4 AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | WEATHER COOL SALES PVT LTD L7 | PRANAM HVAC ENGINEERING PVT LTD L3 | Aqua Cool Co. Pvt.Ltd. L5 | VAV Airconditioning L4 | global air tecnix L1 | PNEUMATIC ENGINEERS PVT LTD. L6 | aselectric corporation L8 | ANSHUTECH AIRCONDITIONING PVT LTD L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Supply, installing, testing and commissioning of DX air cooled air conditioning units non Inverter type as described in specifications. The unit shall be complete with decorative type Indoor coil unit and external condensing unit, complete in all respects, inclusive of complete working charge of HFC-410a/ 32 or any eco friendly gas and oil, copper refrigerant piping, GI condensate drain piping, valves and insulation quoted price shall include cost of cooling thermostat, power wiring, control wiring and earthing. the price including of stand of Indoor units, Refrigerent charging, top up and anti corrosion epoxy resin coating on ODU units etc. The unit capacities shall be as follows:Ductables Ceiling concealed type | |||||||||||
| 1.01 | 5.5 TR | 5 | Nos | 1,27,286 ₹6,36,430 | 1,58,000 ₹7,90,000 | 1,24,284 ₹6,21,420 | 1,34,702 ₹6,73,510 | 1,09,500 ₹5,47,500 Lowest | 2,00,000 ₹10,00,000 | 1,19,505 ₹5,97,525 | 1,13,217 ₹5,66,085 |
| 2.00Hi-Wall | |||||||||||
| 2.01 | 1.0 TR | 27 | Nos | 34,671.88 ₹9,36,140.76 | 27,200 ₹7,34,400 | 27,697 ₹7,47,819 | 27,353 ₹7,38,531 | 26,331.25 ₹7,10,943.75 | 40,000 ₹10,80,000 | 34,503 ₹9,31,581 | 24,012 ₹6,48,324 Lowest |
| 2.02 | 1.5 TR | 54 | Nos | 39,367.19 ₹21,25,828.26 | 30,600 ₹16,52,400 | 33,195 ₹17,92,530 | 32,853 ₹17,74,062 | 29,456.25 ₹15,90,637.5 | 50,000 ₹27,00,000 | 38,648.94 ₹20,87,042.76 | 28,700 ₹15,49,800 Lowest |
| 3.00Cassatte Unit | |||||||||||
| 3.01 | 1.5TR | 2 | Nos | 69,814.13 ₹1,39,628.26 | 57,700 ₹1,15,400 | 68,011 ₹1,36,022 | 55,029 ₹1,10,058 | 54,181.25 ₹1,08,362.5 | 55,000 ₹1,10,000 | 64,676.85 ₹1,29,353.7 | 46,753 ₹93,506 Lowest |
| 3.03 | 2 TR | 4 | Nos | 75,685.7 ₹3,02,742.8 | 67,000 ₹2,68,000 | 68,351 ₹2,73,404 | 62,529 ₹2,50,116 | 56,915.63 ₹2,27,662.52 | 65,000 ₹2,60,000 | 69,285 ₹2,77,140 | 52,222 ₹2,08,888 Lowest |
| 3.04 | 3 TR | 3 | Nos | 95,274.83 ₹2,85,824.49 | 99,000 ₹2,97,000 | 99,658 ₹2,98,974 | 91,029 ₹2,73,087 | 75,275 ₹2,25,825 | 90,000 ₹2,70,000 | 91,605 ₹2,74,815 | 71,635 ₹2,14,905 Lowest |
| 4.00Refrigerant piping Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories,insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber with GC cloth tubular sleeves sections of specified thickness as given below for Suction and Liquidlines, all accessories as per specifications etc. Note:- individual piping will not be measured All exposed pipe should be laid in ladder/perforated type tray | |||||||||||
Tender Value
₹1.1 Cr
EMD Value
₹2.2 L
Closing Date
4 Apr 2022, 3:00 pmClosed
DIRECTOR TMC
Office of Engineering services, Second Floor,Khanolkar Shodhika , ACTREC Kharghar Node, Navi Mumbai
Supply, Installation, testing and commissioning of HVAC System at OPD Builidng, ACTREC
2022_TMC_679643_1
SITC HVAC OPD building ACTREC
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
150 days
ACTREC Kharghar
As per tender terms and condition
2 documents required · 2 mandatory
₹0
₹2.2 L
Yes
ACTREC Kharghar
24 May 2022
19 Mar 2022
5 Apr 2022
19 Mar 2022
4 Apr 2022
19 Mar 2022
19 Mar 2022 - 23 Mar 2022
24 Mar 2022
Amount
Supply, installing, testing and commissioning of DX air cooled air conditioning units non Inverter type as described in specifications. The unit shall be complete with decorative type Indoor coil unit and external condensing unit, complete in all respects, inclusive of complete working charge of HFC-410a/ 32 or any eco friendly gas and oil, copper refrigerant piping, GI condensate drain piping, valves and insulation quoted price shall include cost of cooling thermostat, power wiring, control wiring and earthing. the price including of stand of Indoor units, Refrigerent charging, top up and anti corrosion epoxy resin coating on ODU units etc. The unit capacities shall be as follows:Ductables Ceiling concealed type
Hi-Wall
Cassatte Unit
Refrigerant piping Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories,insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber with GC cloth tubular sleeves sections of specified thickness as given below for Suction and Liquidlines, all accessories as per specifications etc. Note:- individual piping will not be measured All exposed pipe should be laid in ladder/perforated type tray
1/4,3/8 with 1.2mm tube thickness and insulation as per OEM standard. Or equivelent to the unit of 1.0TR hiwall
1/4,1/2 with 1.2mm tube thickness and insulation as per OEM standard.equivelent to the unit of 1.5TR hiwall
3/8,5/8 with 1.2mm tube thickness and insulation as per OEM standard or equivelent to the cassette unit
1/2,7/8 with 1.2mm tube thickness and insulation as per OEM standard or equivelent to the ductable unit
PVC Drain Condensate Drain Water piping constructed out of PVC / HDPE hard pipes, fitting, accessories, bends, elbows, tees, flanges, tappings, wall sleeves, hangers, supports, anchors. The pipes to be duly insulated with 9 mm Nitrile rubber insulation.
Canvas connection
Supply, installation, testing and commissioning of Flexible double Canvass Connections with all necessary hardware, fitting, suppoets etc for DUCTABLE, FCU & FAN and Air washer.
Frame Work
Supply, fabrication and installation, Testing and Commissioning of MS base frame for outdoor units complete with epoxy painting, vibration isolation pads, supports, hangers, railing, brackets etc.
Supply, Installation, testing & commissioning of FactoryFabricated GSS Rectangular/round ducts of following thickness including necessary supports flexible hangers with isolators, nut bolts, neoprene rubber gasket, elbow,flanges splitter damper vanes, etc. complete as per SMACNA
24 guage Rectangular Ducting
22 guage Rectangular Ducting
Thermal Insulation
Thermal Duct Insulation with 13 mm thick , Fire rated, Closed cell type rubber insulation with 32 Kg/m3 density and metalic foil. Apply approved adhesive as per manufacturers recommendation and Anti-microbain type. All insulation joints be overlapped on each other and must be covered with self adhsive insulation tape.
Acoustic Insulation
Supply, installation, testing and commissioning of 10mm thick open cell nitrile rubber accoustic insulation from inside the ducts.
Grill
Supply & Installation of Supply air / Return air Aluminium extruded Powder Coated linear bar Grille 0 /15/45deg deflection of size 100/150 mm with end flanges.
Damper
Volume Control Dampers (Gear Operated and Low Leakage)Supplying loading, unloading at site, storing, fixing of opposed blade volume control dampers in supply air duct as per approved drawings and specifications. Damper shall be with 18G GSS body and blades shall be with aluminium airfoil construction.
Supply, Installation testing & Commissioning of Collar Damper
Fire Dampers
Supplying, Fixing,testing and commissioning of fusible link type fire dampers in supply air duct/main branch and return air path as and where required of required sizes . The damper shall also be closed in the event of fire signal complete as required and as per specifications.
Cables
Power Cable for panel to ODU panel Supply, laying, dressing, termination, testing & commissioning 1100 V grade, copper conductor, PVC insulated, steel wire/strip armoured, PVC sheathed power and control cables as per specs. Of following sizes, including clamping, as per specs. 4cX4 Sqmm Cable
Power Cable for IDU Supply, laying, dressing, termination, testing & commissioning 1100 V grade, copper conductor, PVC insulated, steel wire/strip armoured, PVC sheathed power and control cables as per specs. Of following sizes, clamping, as per specs. 3c x 2.5 sqmm cable
Control cable between ODU AND IDU Supply & Installation of All control cables between indoor and outdoor unit flexible and between ODU & ODU laid in PVC pipe and clamped . 6C x 1.5 sqmm cable
4C x 2.5 sqmm cable
LPG system
Dismatling of exting LPG bank and pipe line with all necassry supports, valves, regulator etc as per instructed and as directed by OIC-ES
CMC rates for entire system as mentioned above
CMC rates for the 2nd year
CMC rates for the 3rd year
CMC rates for the 4th year
CMC rates for the 5th year
ANSHUTECH AIRCONDITIONING PVT LTD
PRANAM HVAC ENGINEERING PVT LTD
VAV Airconditioning
Aqua Cool Co. Pvt.Ltd.
PNEUMATIC ENGINEERS PVT LTD.
WEATHER COOL SALES PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.84 MB
Tenderdocument.pdf.pdf
Tender Documents • 1.99 MB
AnnexureForm.xls
Additional Documents • 0.11 MB
OM.pdf
Additional Documents • 4.23 MB
BOQ_715213.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .