Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAdmitted-Finance KRAL PORA BAGH I MEHTAB NEAR MANCHOWA PETROL PUMP DISTRICT BUDGAM 190019 J K | BUDGAM | BUDGAM | J K | 190019 | ₹13.8 L | L1 | Admitted-Finance |
| 2 | L2₹23.7 L+₹9.9 L (72.1%)Admitted-Finance | ₹23.7 L+₹9.9 L (72.1%) | L2 | Admitted-Finance |
| 3 | L3₹23.9 L+₹10.1 L (73.6%)Admitted-Finance DHARAM SALA SINGHAN CHADOORA DISTT BUDGAM J K | CHADOORA | BUDGAM | JAMMU AND KASHMIR | ₹23.9 L+₹10.1 L (73.6%) | L3 | Admitted-Finance |
| 4 | L4₹24.4 L+₹10.6 L (77.1%)Admitted-Finance | ₹24.4 L+₹10.6 L (77.1%) | L4 | Admitted-Finance |
| 5 | L5₹24.5 L+₹10.7 L (77.6%)Admitted-Finance | ₹24.5 L+₹10.7 L (77.6%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s Alam-i-Afroz L7 | FG CONSTRUCTION L6 | M/S LATIF AHMED MIR L2 | M/S RATHER CONSTRUCTION CO L1 | M/S M.Y Enterprises L5 | M/S NEW FAROOQ TRADERS L4 | M/s Jaipal Associates L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and erect in true vertical position 9.50m long steel tubular swaged poles, type 410 SP-37, with 300mm x 300mm x 6mm mild steel base plate continuously welded to pole, finial tapper plug, bolts, nuts and screws and making holes as per requirement all as specified including factory painted with two coats black bituminous paint internally throughout and externally for embedded portion and applying one coat of red oxide primer, making 05 Nos strips each 30 cm high with super enamel paint with alternate (Black and Yellow / White) colour scheme from ground level / coping upto 1.5m painting with two coats of aluminium paint for the remaining height including taking down old swaged pole, complete all as specified and directed.
(Note:- Excavation, earth work and PCC will be measured and paid separately in respective items.) | 9 | Each | 26,000 ₹2,34,000 | 15,000 ₹1,35,000 | 14,500 ₹1,30,500 | 6,000 ₹54,000 Lowest | 16,000 ₹1,44,000 | 15,500 ₹1,39,500 | 14,000 ₹1,26,000 |
| 2.00 | M&L for PCC, 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling / mass concrete etc., complete all as specified and directed. | 6.5 | Cubic Metre | 3,500 ₹22,750 | 2,000 ₹13,000 | 3,000 ₹19,500 | 1,500 ₹9,750 Lowest | 2,000 ₹13,000 | 2,800 ₹18,200 | 2,200 ₹14,300 |
| 3.00 | M&L for cement concrete 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate) as in coping for pole and the like, weathering, slightly rounded or chamfered angles including necessary form work, complete all as specified and directed. | 2.5 | Cubic Metre | 4,000 ₹10,000 | 2,000 ₹5,000 | 3,200 ₹8,000 | 1,580 ₹3,950 Lowest | 3,000 ₹7,500 | 3,200 ₹8,000 | 2,600 ₹6,500 |
| 4.00 | M&L for shifting of serviceable / unserviceable transformer / RMU / VCB panels from one location to another location of capacity 63 to 1000 KVA from existing PCC platform / four pole / two pole structure / MES store yard and fixing on platform / four pole / two pole structure by suitable capacity of crane including necessary disconnection and connection on both side and testing on completion, complete all as specified and directed. | 5 | Each | 10,000 ₹50,000 | 15,000 ₹75,000 | 3,500 ₹17,500 | 1,350 ₹6,750 Lowest | 2,000 ₹10,000 | 2,000 ₹10,000 | 2,500 ₹12,500 |
| 5.00 | M&L for disconnecting of supply from any capacity of panel board / RMU of any capacity and size for over hauling / repair / re-wiring works, servicing and taking out trolley. Dismantling carefully and replacing defective parts found at the time of servicing complete with decarburizing the contact points, cleaning with CRC solution etc including calibration of relays for tripping time setting over current setting, earth fault setting and testing of panel with the help of primary injection test set for protection CT after repair, complete all as specified and directed. | 4 | Each | 10,000 ₹40,000 | 20,000 ₹80,000 | 6,000 ₹24,000 | 2,250 ₹9,000 Lowest | 4,500 ₹18,000 | 5,000 ₹20,000 | 3,000 ₹12,000 |
| 6.00 | S&F 210 Watt LED flood light fitting, for operating between 110V to 230 V system efficiency not less than 120 lumen / Watt PF-0.95 minimum, IP-66 protection, 5700 CCT (K), CRI between 80-85, confirming to LM79 and LM 80 standards or as per IS-16106:2012, for estimated life span of minimum 50,000 hrs consisting of high/ low voltage cut off, maintenance free isolated electronic driver circuits, Low THD, PMMA grade high quality transmittance lens, epoxy powder coated Die cast aluminium housing with LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartement, heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws with IP-65/66 protection including taking down existing unserviceable light, complete all as specified and directed. | 25 | Each | 5,900 ₹1,47,500 | 4,500 ₹1,12,500 | 2,500 ₹62,500 Lowest | 8,000 ₹2,00,000 | 11,500 ₹2,87,500 | 9,100 ₹2,27,500 | 7,200 ₹1,80,000 |
| 7.00 | S&F in replacement PVC insulated cu stranded (FRLSH) wire 1.5 sqmm, passing through the non metallic PVC conduit from junction box to LED security light terminals. All connections should be made with proper size of thimbles, complete all as specified and directed. | 357 | Running Metre | 20 ₹7,140 | 25 ₹8,925 | 5 ₹1,785 Lowest | 12 ₹4,284 | 35 ₹12,495 | 30 ₹10,710 | 30 ₹10,710 |
| 8.00 | S&F in replacement of Rigid non-metallic PVC conduit of size 20mm dia exclusive of boxes (junction / terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc., complete all as specified and directed. | 247.5 | Running Metre | 15 ₹3,712.5 | 40 ₹9,900 | 5 ₹1,237.5 Lowest | 31 ₹7,672.5 | 45 ₹11,137.5 | 35 ₹8,662.5 | 20 ₹4,950 |
| 9.00 | S&F in replacement PVC weather proof junction boxes of size 250 x 200 x 100mm (Inside dimentions) with PVC connector heavy duty connector 4 way 16 amps ,one No MCB SP 6 Amps and making necessary cable connection, complete all as specified and directed. | 55 | Each | 1,100 ₹60,500 | 800 ₹44,000 | 750 ₹41,250 | 660 ₹36,300 | 800 ₹44,000 | 750 ₹41,250 | 550 ₹30,250 Lowest |
| 10.00 | S&F in replacement LED bollard lightlight fitting 9W, CCT 5700 K with all fixing accessories fitted on including making suitable foundation for anchoring in PCC 1:2:4, type-B-1, complete all as specified and directed. | 20 | Each | 1,400 ₹28,000 | 3,000 ₹60,000 | 2,670 ₹53,400 | 560 ₹11,200 Lowest | 4,000 ₹80,000 | 3,400 ₹68,000 | 2,800 ₹56,000 |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
24 Aug 2026, 6:00 pmClosed
GE (AF) SRINAGAR
Garrison Engineer (AF) Air Force Station Srinagar 190 007
CA NO. GE (AF)/SGR-46/2026-27 REPAIR TO CERTAIN E/M INSTALLATIONS AT NO 2 AREA UNDER GE (AF) SRINAGAR
2026_MES_780993_1
GE(AF)/SGR-46/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AOR of GE (AF) SRINAGAR
Please refer NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) Srinagar
₹76,000
Yes
27 Aug 2026
27 Jul 2026
26 Aug 2026
27 Jul 2026
24 Aug 2026
10 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and erect in true vertical position 9.50m long steel tubular swaged poles, type 410 SP-37, with 300mm x 300mm x 6mm mild steel base plate continuously welded to pole, finial tapper plug, bolts, nuts and screws and making holes as per requirement all as specified including factory painted with two coats black bituminous paint internally throughout and externally for embedded portion and applying one coat of red oxide primer, making 05 Nos strips each 30 cm high with super enamel paint with alternate (Black and Yellow / White) colour scheme from ground level / coping upto 1.5m painting with two coats of aluminium paint for the remaining height including taking down old swaged pole, complete all as specified and directed.
(Note:- Excavation, earth work and PCC will be measured and paid separately in respective items.) | 9 | Each | - | - |
| 2 | M&L for PCC, 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling / mass concrete etc., complete all as specified and directed. | 6.5 | Cubic Metre | - | - |
| 3 | M&L for cement concrete 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate) as in coping for pole and the like, weathering, slightly rounded or chamfered angles including necessary form work, complete all as specified and directed. | 2.5 | Cubic Metre | - | - |
| 4 | M&L for shifting of serviceable / unserviceable transformer / RMU / VCB panels from one location to another location of capacity 63 to 1000 KVA from existing PCC platform / four pole / two pole structure / MES store yard and fixing on platform / four pole / two pole structure by suitable capacity of crane including necessary disconnection and connection on both side and testing on completion, complete all as specified and directed. | 5 | Each | - | - |
| 5 | M&L for disconnecting of supply from any capacity of panel board / RMU of any capacity and size for over hauling / repair / re-wiring works, servicing and taking out trolley. Dismantling carefully and replacing defective parts found at the time of servicing complete with decarburizing the contact points, cleaning with CRC solution etc including calibration of relays for tripping time setting over current setting, earth fault setting and testing of panel with the help of primary injection test set for protection CT after repair, complete all as specified and directed. | 4 | Each | - | - |
| 6 | S&F 210 Watt LED flood light fitting, for operating between 110V to 230 V system efficiency not less than 120 lumen / Watt PF-0.95 minimum, IP-66 protection, 5700 CCT (K), CRI between 80-85, confirming to LM79 and LM 80 standards or as per IS-16106:2012, for estimated life span of minimum 50,000 hrs consisting of high/ low voltage cut off, maintenance free isolated electronic driver circuits, Low THD, PMMA grade high quality transmittance lens, epoxy powder coated Die cast aluminium housing with LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartement, heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws with IP-65/66 protection including taking down existing unserviceable light, complete all as specified and directed. | 25 | Each | - | - |
| 7 | S&F in replacement PVC insulated cu stranded (FRLSH) wire 1.5 sqmm, passing through the non metallic PVC conduit from junction box to LED security light terminals. All connections should be made with proper size of thimbles, complete all as specified and directed. | 357 | Running Metre | - | - |
| 8 | S&F in replacement of Rigid non-metallic PVC conduit of size 20mm dia exclusive of boxes (junction / terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc., complete all as specified and directed. | 247.5 | Running Metre | - | - |
| 9 | S&F in replacement PVC weather proof junction boxes of size 250 x 200 x 100mm (Inside dimentions) with PVC connector heavy duty connector 4 way 16 amps ,one No MCB SP 6 Amps and making necessary cable connection, complete all as specified and directed. | 55 | Each | - | - |
| 10 | S&F in replacement LED bollard lightlight fitting 9W, CCT 5700 K with all fixing accessories fitted on including making suitable foundation for anchoring in PCC 1:2:4, type-B-1, complete all as specified and directed. | 20 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.16 MB
BOQ_874881.xls
BOQ • 4.28 MB
Tender46.pdf
Tender Documents • 0.81 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .