| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 LAccepted-AOC RZ 1 7 167 GALI NO 6 DURGA PARK NASIRPUR SOUTH WEST DELHI DELHI 110045 | SOUTH WEST | DELHI | 110045 | ₹23.0 L Quoted ₹23.9 L | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹25.7 L+₹1.8 L (7.52%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹25.7 L+₹1.8 L (7.52%) | L2 | Rejected-Finance Being other than lowest |
| 3 | L3₹27.4 L+₹3.6 L (14.9%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | ₹27.4 L+₹3.6 L (14.9%) | L3 | Rejected-Finance Being other than lowest |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not uploaded MoU as per format given in tender documents |
| 5 | Rejected-Technical N A | NEW DELHI | DELHI | 110001 | - | - | Rejected-Technical Not uploaded MoU as per format given in tender documents |
Tender Value
₹45.1 L
EMD Value
₹90,280
Closing Date
31 Oct 2024, 6:00 pmClosed
GE (EAST) DELHI CANTT-10
GE (EAST) DELHI CANTT-10
MISC REPAIR/ REPLACEMENT TO SUMMER APPLIANCE, SPLIT ACs WINDOW ACs, TOWER ACs AND OTHER CONNECTED MISC E/M WORKS UNDER AGE E/M BHDC UNDER GE (EAST) DELHI CANTT-10
2024_MES_668397_1
GE/DE-42/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE (EAST) DELHI CANTT-10
Class D Cat c (i)
7 documents required · 7 mandatory
₹0
₹90,280
Yes
21 Dec 2024
31 Aug 2024
4 Nov 2024
31 Aug 2024
31 Oct 2024
18 Oct 2024
Amount
Attending the break down complaint of all nature for window/split AC/tower AC/ cassette AC and their electrical wiring from main DBs of any capacity and make them functional and also carry out the required repair on all days including Sunday and holidays complete all as specified and directed. Notes- (i) Adequate resoures shall be deployed by the contractor for attending complaints being an essential services with adequate Nos of AC mechanic & helpers to attend day to day as per requiremetn and as directed by Engr-in-Charge. (ii) Any parts/ accessories required to be replaced shall be measured and paid separately under respective items of this Schedule/BoQ. (iii) All refrigerator mechanic to be deployed at work should have in possesion of ITI certificate in refrigeration and air conditioning or equivalent trade with at least 03 (Three) years experience in this field. (iv) Complaint should be attend within 2 hrs. (v) If complaint not attended within 2hrs, recovery will be done as follows:- (a) For upto 12 hrs @ Rs 500. (b) for more than beyond 12 hrs @ 1000 Rs per 12 hrs.
M&L for servicing of window type AC of 1.0/1.5/2.0 TR capacity, of any type/make, at site /wall, comprising of taking down carefully, removing power connections and front PVC grills, air filters, cleaning, washing, removing dirt, servicing including chemical wash of cooling coil, indoor cooling unit and condenser coil and providing oil and grease to all moving parts including condensing motor, checking and making serviceable electrical connection of DB's, stabilizer, wiring of AC's as per site condition and tightening all electrical connection with thimble and replacing the spare parts of the AC units wherever required, testing & commissioning including refixing at the original position and connecting with the system complete all as specified and as directed. Notes:- (i) Contractor shall maintain register of servicing as per format given by Engr-in-Charge duly signed by User, where the servicing of equipment carry out and produce as & when asked by Engr-in-Charge or GE. (ii) Spare parts required for repairs shall be measured and paid separately under respective item of this Schedule/ BoQ.
M&L for servicing of split type AC of 1.5/2.0 TR capacity, of any type/make, at site /wall, including removing power connections and front PVC grills, air filters, cleaning, washing, removing dirt, servicing including chemical wash of cooling coil, cooling unit and condenser coil of outdoor unit, checking and making serviceable electrical connection of DB's, stabilizer, wiring of AC's as per site condition and tightening all electrical connection with thimble and replacing the spare parts of the AC units wherever required, testing & commissioning including refixing at the original position and connecting with the system complete all as specified and as directed. Notes:- (i) The cost of additional inlet/outlet copper pipes, drain pipe and electrical cord, if required and making good of surface as original by plastering/ whitewash/ colour/ distemper etc shall deemed to be included in quoted rate and no extra payment shall be made to contractor on this account. (ii) Contractor shall maintain register of servicing as per format given by Engr-in-Charge duly signed by User, where the servicing of equipment carry out and produce as & when asked by Engr-in-Charge or GE. (iii) Spare parts required for repairs shall be measured and paid separately under respective item of this Schedule/ BoQ.
All as per srl item No 3.00 here-in-before but Tower type split AC of any capacity complete all as specified and as directed.
Supply only of remote for window/ split type AC any type and any capacity as per existing make/ model at site cpmplete all as specified and directed.
Taking down, repairing and re-fixing PCB, suitable for inverter type type split AC/ window AC of any capacity and model complete all as specified and directed.
S&F in replacement of PCB, suitable for inverter type, split AC/ window AC of any capacity and model complete all as specified and as directed.
Taking down, repairing and re-fixing PCB, suitable for tower type AC of any capacity and model complete all as specified and directed.
S&F in replacement of PCB suitable for tower type AC of any capacity and model complete all as specified and as directed.
M&L for making necessary arrangement/alteration to make reversible system (reverse valve) to functioning as heat engine in winter i.e. cooling in summer and heating in winter, by providing necessary copper tubing, refrigerant valve, modification in remote unit (PCB) and allied work for the split/ window Air Conditioner of 1.5/2.0 TR capacity complete all as specified and as directed. Note: Charging of refrigerant gas, if required, shall be measured and paid separately.
S & F in replacement sealed compressor unit, reciprocating type/ rotary type/ Scroll type, suitable for 1.5 TR window type AC/ Split AC of existing capacity and make complete all as specified and as directed.
S & F in replacement sealed compressor unit, reciprocating type/ rotary type/ scroll type, suitable for 2.0 TR window type AC/ Split AC of existing capacity and make complete all as specified and as directed.
S & F in replacement sealed compressor unit, reciprocating type/ rotary type/ scroll type, suitable for 3.0 TR tower type AC suitable for 3 phase supply of existing capacity and make complete all as specified and as directed.
S&F in replacement sealed compressor unit, reciprocating type/ rotary type/ scroll type,, suitable for 3.5 TR Tower type AC, 3 phase power supply of existing capacity and make complete all as specified and as directed.
S&F in replacement sealed compressor unit, reciprocating type/ rotary type/ scroll type,, suitable for 4.5 TR Tower type AC, 3 phase power supply of existing capacity and make complete all as specified and as directed.
Supply & fixing in replacement window AC Kit internal wiring for 1.5 / 2.0 TR capacity AC complete all as specified and as directed.
Supply & fixing in replacement Split type AC Kit internal wiring for 1.5 / 2.0 TR capacity AC complete all as specified and as directed.
Supply & fixing in replacement drain pipe PVC medium grade size 25 mm dia including fittings complete all as specified and as directed.
Supply & fixing in replacement drain pipe PVC flexible type 15/20 mm dia including fittings complete all as specified and as directed.
Taking down, repairing and re-fixing PCB, suitable for non inverter type split AC/ window AC of any capacity and model complete all as specified and directed.
S&F in replacement of PCB, suitable for non-inverter type, split AC/ window AC of any capacity and model complete all as specified and as directed.
Supply & fixing in replacement running capacitor 50+6 MFD complete all as specified and as directed.
Supply & fixing in replacement running capacitor 45+6 MFD complete all as specified and as directed.
Supply & fixing in replacement capacitor 4 MFD complete all as specified and as directed.
Supply & fixing in replacement Capacitor 6 MFD complete all as specified and as directed.
Supply & fixing in replacement indoor unit swing motor, suitable for split AC of existing capacity and model complete all as specified and as directed.
Supply & fixing in replacement Split AC Indoor Unit blower motor, single shaft suitable for existing capacity and make complete all as specified and as directed.
Supply & fixing in replacement Indoor unit Air blower for Split type AC 1.5/2.0 TR complete all as specified and as directed.
Supply & fixing in replacement display suitable for Split type AC/ window type AC of existing make complete all as specified and as directed.
Supply & fixing in replacement Split AC outdoor unit fan motor for any capacity, Single shaft suitable for existing make and model complete all as specified and as directed.
Taking down repairing/rewinding and fixing Split AC ODU fan motor for any capacity of Single shaft suitable for existing make and model complete all as specified and directed.
Supply & fixing in replacement fan blade of Condenser motor for Split AC of capacity 1.5TR/2.0 TR complete all as specified and as directed.
Supply & fixing in replacement fan blade of motor for window AC of capacity 1.5TR/2.0 TR complete all as specified and as directed.
Supply & fixing in replacement Motor suitable for window type AC of existing capacity, double shaft complete all as specified & as directed.
Taking down repairing/rewinding and fixing Motor suitable for window type AC of existing capacity , double shaft complete all as specified & directed.
Supply & fixing in replacement Air blower for Window type AC 1.5/2.0 TR complete all as specified and as directed.
Supply & fixing in replacement cooling coil made out of copper tube & Aluminium fins of window AC 1.5/2.0 Ton complete all as specified and as directed.
Supply & fixing in replacement condenser coil made out of copper tube & Aluminium fins complete of window AC 1.5/2.0 TR as per existing system complete all as specified and as directed.
S&F in repair Evaporator Coil made out of copper tube & Aluminium fins, suitable for indoor unit of split AC of capacity 1.5/2.0 TR of existing make and model complete all as specified and as directed.
S&F in repair Condenser Coil, size 24 inch and 2 row, made out of copper tube & Aluminium fins, suitable for Outdoor Unit of split AC of capacity 1.5/2.0 TR of existing make and models complete all as specified and as directed.
S&F in repair Evaporator Coil made out of copper tube & Aluminium fins, suitable for indoor unit of Tower type AC of 3.0/4.0/4.5 TR capacity of existing make and model complete all as specified and as directed.
S&F in repair Condenser Coil, made out of copper tube & Aluminium fins, suitable for Outdoor Unit of Tower type AC of 3.0/4.0/4.5 TR capacity of existing make and models complete all as specified and as directed.
Supply & fixing in replacement starting relay suitable for window type AC/ split type AC of existing capacity and make complete all as specified and as directed.
Supply & fixing in replacement Indoor unit Air blower for tower type splt AC 3.0 TR complete all as specified and as directed.
Supply & fixing in replacement starting relay suitable for tower type AC of existing capacity and make complete all as specified and as directed.
Supply & fixing in replacement over load protector relay for tower type AC of any capacity complete all as specified and as directed.
S&F in repair contactor of suitable capacity for split type AC of any capacity complete all as specified and as directed.
Supply & fixing in replacement PVC insulated, multi stranded, 3 core, flexible, copper conductor cable, of size 2.5 sqmm complete all as specified and as directed.
Supply & fixing in replacement PVC insulated, multi stranded, 3 core, flexible, copper conductor cable, of size 4.0 sqmm complete all as specified and as directed.
Supply & fixing in replacement flexible copper conductor cable 4.0 Sqmm, 4 core, PVC insulated & PVC sheathed complete all as specified and directed.
Supply and charging R-22 refrigerant gas, including and after carrying out the pressure test with nitrogen and rectify the leakage of split AC/window AC/ water cooler/ tower AC/Cassette AC complete all as specified and as directed.
Supply and charging R-134A refrigerant gas, including and after carrying out the pressure test with nitrogen and rectify the leakage of split AC/window AC/ water cooler/ tower AC/Cassette AC complete all as specified and as directed.
Supply and charging R-410A refrigerant gas, including and after carrying out the pressure test with nitrogen and rectify the leakage of split AC/window AC/ water cooler/ tower AC/Cassette AC complete all as specified and as directed.
Supply and charging R-32 refrigerant gas, including and after carrying out the pressure test with nitrogen and rectify the leakage of split AC/window AC/ water cooler/ tower AC/Cassette AC complete all as specified and as directed.
Supply & fixing in replacement front grill as per sample, suitable for existing model of window type AC 1.5TR/ 2.0 TR capacity complete all as specified and as directed.
Supply & fixing in replacement front grill as per sample suitable for 1.5 TR/ 2.0 TR capacity Split type AC complete all as specified and as directed.
Supply & fixing in replacement copper pipe 1/2” dia, wall thickness 0.032 mm including insulation complete all as specified & as directed.
Supply & fixing in replacement copper pipe 1/4" dia, wall thickness 0.030 mm including insulation complete all as specified & as directed.
Supply & fixing in replacement copper pipe 5/8" dia, wall thickness 0.035 mm including insulation complete all as specified & as directed.
Supply & fixing in replacement copper pipe 3/8" dia, wall thickness 0.032 mm including insulation complete all as specified & as directed.
S&F in replacement copper tubing 6/8" dia & wall thickness 0.039 mm including insulation complete all as specified and directed.
S&F in replacement of Pin/service/ charging valve of size 1/2", 1/4'' for window AC and Split AC of existing model complete all as specified and as directed.
S&F in replacement of outdoor stand of floor mounted type/ Wall mounted type with fastener for split AC complete all as specified and as directed.
Supply & fixing in replacement plug top 3 pin, 15 Amp, complete all as specified & as directed.
M&L for shifting of Split type AC of any capacity, any type/make, with stabilizer including taking down carefully indoor and outdoor unit, copper piping, drain pipe and thermal sleeve, lifting angle etc and installing the same to new location using existing copper piping for suction and delivery with insulation, drain pipe and re-fixing arrangement i. e. lifting angle, fasteners, nut bolt, washer etc, testing & commissioning complete all as specified and directed. Notes: (i) The cost of making hole for passing through inlet/outlet copper pipes, drain pipe and electrical cord and making good of surface at both location as original by plastering / whitewash / colour / distemper etc shall deemed to be included in quoted rate and no extra payment shall be made to contractor on this account. (ii) The additional copper piping & Gas charging, if required shall be measured and paid separately under respective items of this Schedule.
M&L for shifting of window type AC of any capacity, any type/make, with stabilizer from one location to another complete with and including making of suitable opening in brick wall or removing aluminium grill and/or glass pane from existing window, including supply and fixing of new wooden frame of suitable size and thickness for proper fixing of outer chassis of AC at new location, making good of disturbed surface to match with the original, including testing & commissioning complete all as specified and as directed. Note: The cost of making suitable opening in brick wall or removing aluminium grill and/or glass pane from existing window and making good of surface at both location as original by plastering / white wash / colour / distemper etc shall deemed to be included in quoted rate and no extra payment shall be made to contractor on this account.
BLANK
BLANK
Supply & fixing in replacement industrial type metal clad socket only of 20 Amps complete all as specified and as directed.
Supply & fixing in replacement metal clad top 20 Amp complete all as specified and as directed.
Supply & fixing in replacement tower AC outdoor unit fan motor for any capacity, Single shaft suitable for existing make and model complete all as specified and as directed.
Taking down repairing/rewinding and fixing tower AC ODU fan motor for any capacity of Single shaft suitable for existing make and model complete all as specified and directed.
S&F in replacement of indoor unit complete set, suitable for 1.5 TR split AC, consisting of blower motor, blower, wiring kit complete with display, electronic card with remote assembly, evaporative /cooling coil, remoting system, and plastic housing with bracket frame suitable for R-32/ R-410 gases complete all as specified and as directed. Make : HItachi/ Camipro/ Carrier
S&F in replacement of indoor unit complete set, suitable for 2.0 TR split AC, consisting of blower motor, blower, wiring kit complete with display, electronic card with remote assembly, evaporative /cooling coil, remoting system, and plastic housing with bracket frame suitable for R-32/ R-410 gases complete all as specified and as directed. Make : HItachi/ Camipro/ Carrier
S&F in replacement of outdoor unit complete set, suitable for 1.5 TR split AC , including condenser coil with fins, outdoor fan motor with fan blade, chassis/ cabinet, capacitor, wiring kit, capalliary, filter, base plate complete set including compressor suitable for R-32/ R-410 gases complete all as specified & as directed. Make : HItachi/ Camipro/ Carrier
S&F in replacement of outdoor unit complete set, suitable for 2.0 TR split AC , including condenser coil with fins, outdoor fan motor with fan blade, chassis/ cabinet, capacitor, wiring kit, capalliary, filter, base plate complete set including compressor suitable for R-32/ R-410 gases complete all as specified & as directed. Make : HItachi/ Camipro/ Carrier
S&F in replacement of window AC suitable for 1.5 TR Capacity of existing make & model, including condenser and evaporative coil, dual shaft motor with blower and blade, chassis, base plate complete set except compressor complete all as specified & as directed.
S&F in replacement of window AC suitable for 2.0 TR Capacity of existing make and model, including condenser and evaporative coil, dual shaft motor with blower and blade, chassis, base plate complete set except compressor complete all as specified & as directed.
S&F in replacement of AC filter of suitable size for window type/ split type AC complete all as specified and directed.
S&F in replacement of indoor AC unit back plate for split type AC complete all as specified and directed.
S&F in replacement of indoor AC blower fan bush of suitable size for split type AC of any capacity complete all as specifed and directed.
S&F in replacement of Pin/service/ charging valve of size 3/8", 5/8'' for window AC and Split AC of existing model complete all as specified and as directed.
M&L in repair sub main wiring with 2 runs of 4.0 Sqmm single core, PVC insulated & unsheathed FR cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 25 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and one run of 4.0 Sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Two run of 4.0 Sqmm cable and one run of 4.0 Sqmm earth conductor along with 25 mm PVC conduit with accessories shall be measured as one length)
M&L in repair sub main wiring with 2 runs of 6.0 Sqmm single core, PVC insulated & unsheathed FRLS cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 32 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and one run of 6.0 Sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Two run of 6.0 Sqmm cable and one run of 6.0 Sqmm earth conductor along with 25 mm PVC conduit with accessories shall be measured as one length)
M&L in repair sub main wiring with 4 runs of 10.0 Sqmm single core, PVC insulated & unsheathed FRLS cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 40 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and 2 run of 10.0 Sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Four run of 10.0 Sqmm cable and two run of 10.0 Sqmm earth conductor along with 40 mm PVC conduit with accessories shall be measured as one length)
S&F in replacement distribution board (DB), double door type, made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, MCB DB, SPN, 8 way, with 200 Amps rated copper bus bar, neutral bar, earth bar, IP 43 protection, 240 Volts, flush to wall complete all as specified and as directed
S & F in replacement of MCB, SPN, 240 Volts, 32 to 40 Amps, C curve type complete all as specified and as directed.
S & F in replacement of MCB, SP, 240 Volts, 6 to 40 Amps complete all as specified and as directed.
S&F in replacement of sheet metal enclosure with socket plug top, single pole and neutral enclosure with a two pin earth plug and socket complete with one MCB of capacity 25 Amps, 240 Volts complete all as specified and as directed.
S & F in replacement distribution board (DB), double door (CRCA sheet) dust and vermin proof TPN 4 way with 100 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, triple pole and neutral 415 Volts, flush to wall complete all as specified and directed.
S & F in replacement MCB TPN, C curve, 415 Volts, 63 Amps complete all as specified and directed.
S & F in replacement MCB SP, C curve, 240 Volts, 63 Amps, 10KA complete all as specified and directed.
SANJEEV ENTERPRISES (BID ID -3147929)
RUCHIKA ENGG.WORKS (BID ID -3144939)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .