| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 CrAccepted-Finance NO 5 TNHB OFFICE COMPLEX R 40 A AMBATTUR ESTATE MAIN ROAD MUGAPPAIR CHENNAI 600037 | CHENNAI | TAMIL NADU | 600037 | ₹4.2 Cr | L1 | Accepted-Finance Accepted |
| 2 | L2₹4.6 Cr+₹44.8 L (10.8%)Rejected-Finance CHENNAI | ₹4.6 Cr+₹44.8 L (10.8%) | L2 | Rejected-Finance Rejected |
| 3 | Rejected-Technical | - | - | Rejected-Technical Rejected |
Tender Value
Refer Docs
EMD Value
₹2.0 L
Closing Date
10 Mar 2025, 3:00 pmClosed
Superintending Engineer II
Superintending Engineer II, CW, Koyambedu, Chennai
Providing Cold storage arrangements at Food Grain Godown, Koyambedu Wholesale Market Complex Chennai 107
2025_CMDAC_528190_1
19/2024-25 (Cold storage_KWMC)
Open Tender
Electrical Works
Lump-sum
180 days
Koyambedu
Registration of Contractor Certificate
Annual Turnover
Similar Work experience
GST Registration
Income Tax Return
Pan card
7 documents required · 7 mandatory
₹0
₹2.0 L
Yes
14 Mar 2025
26 Feb 2025
11 Mar 2025
26 Feb 2025
10 Mar 2025
3 Mar 2025
Amount
Schedule A
Dismantling and Clearing away and carefully stacking materials etc., all complete as directed by departmental officers.
Brick Masonry in cement mortar walls
Floor finish & dadooing walls in cement mortar with Mosaic Tiles / Glazed Tiles / Clay Tiles / Cuddapah Slabs
Doors and Windows including removal of frames, hinges and fastenings
Plain Cement Concrete
Supplying and filling with M-Sand well watered rammed, and consolidated complying with relevant standard specifications etc., complete and as directed by the departmental officers.
Providing and Laying PCC 1:4:8 (1 of Cement, 4 of M-Sand and 8 of graded metal) using 40mm metal including cost and conveyance of all materials mixing, laying, compacting, curing etc., complete and as directed by the dept. officers.
Providing and Laying M 25 Design Mix for all reinforced cement concrete with minimum cement content conform to IS 456-2000 using ordinary Portland cement of grade 53 from approved manufacturer, manufactured sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement. works for all structures etc..excluding necessary centering, shuttering and reinforcement which shall be measured and paid separately under relevant items. Rate to include all designing the mix, batching plant, mechanical mixing, transporting and placing at all levels, leads, lifts, tools & plants, fuels, all materials, labour charges, wastages , laying, pumping the concrete to all levels, providing sleeves / openings in RCC slabs, compaction by vibrator, curing etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
2nd Floor
Supplying, fabricating and fixing in position of steel Fe 550D grade Reinforcement for all RCC work with Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)
Supplying and erecting centering for sides and soffits including supports and strutting up to 3.30 m height with all cross bracing for plane surfaces as detailed below, using mild steel sheets of 90 X 60 cm 10 gauge stiffened with MS angle of 25 X 25 X 3mm for boarding, laid over adjustable span & jacks and supported by 50mm dia pipes for general pipes scaffolding systems @ a spacing of 1.20m c/c and vertical connected at a height of 2.0m c/c including 'C' & 'U' clamps and base receiver cup at bottom for connecting pipes etc and removable systems etc., Rate to include all materials, labour charges, wastages , placing, transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, heights, masking tape in sheet joints, consumables, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slab / beams and such other members
Reinforced cement concrete Column footing, Pilecap, plinth / grade beam, bed blocks, template surfaces, steps, piers, pile cap, raft slab / beams and such other members
Providing and Laying Brick work in CM 1:5 (one cement & five sand) using II nd class Ground moulded bricks of size 9" X 4-3/8" X 2-3/4" including finishing, curing,etc., complete complying with standard specification. Rate to include all materials, labour charges, wastages for working at all levels with necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, curing, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by the Client / Engineer-in-charge.
2nd Floor
Supply, making and fixing of well seasoned Teak wood door frame approved size and as per drawing detail. All exposed wooden surfaces are duly polished with melamine polish of required level. The rate shall be inclusive of making necessary design as per drawing, fixing holdfast in CC 1:2:4 of size 300 X 200 X 150 mm and 75 mm long 10 mm dia anchor fastener to RCC location where ever required. Finishes shall made at Factory only installation at site. Rate including all materials, labour charges, wastages, necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
Scantling shall be up to 2000mm length
Scantling shall be above 2000mm and below 3000mm
Supplying and fixing of 200mm length mild steel hold fasts horizontally twisted with pair of suitable iron screwsetc complete in all respects complying with relevant standard specification and as directed by the Departmental officers.
Providing and fixing Solid core flush shutters with Teak ply on both side with teak wood lipping alround 35 mm thick. The shutter shall be made of solid core of block board type bonded with PF synthetic resin conforming to BWP grade of IS 848 with 6mm thick teak wood lipping finished with melamine polish of approved make, colour & pattern including finishing of door shutters on both sides with 1.0 mm thick laminate of approved pattern as per drawing. The construction procedure of the shutter should be as per IS 2202. The shutter shall be shop prepared for taking mortice lock or latches suitable lock block of wood may be provided for fixing the hardware. The size of block, shall perfectly correspond to the maximum size of lock, covered in IS 2209. All the four edges of the door shutter shall be square. The shutter shall be free from twist or warp in its plane and of required size etc. complete as directed. Rate shall include for cost of hardwares (aluminium hinges 125x30mm size - 3Nos. aluminium aldrop of size - 250x16 mm - 1No. Aluminium tower bolt of size 250x12mm - 1Nos. tower bolt of size 200x12mm - 1No, D type aluminium handle of size 200mm-2No., aluminium door stopper with nylon bush - 1No) as required and fixing them all like lock, hinges, handle, tower bolts, and other accesories etc..as complete with all respects complying with relevant standard specification, as directed by the Departmental officers.
FIRE RATED STEEL DOOR Providing and fixing of 2 Hrs rating Hollow metal Un-Insulated fire rated doors (Insulated fire door with 30Mins Insulation for stability, integrity & insulation at Emergency exits/ staircase exits only.) as per IS 3614 part-1, for stability and integrity. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested to IS 3614 part 2 / ISO 834-1 Part 1 / BS476 Part 20 & 22, CBRI / Cerifire, third party certified, for maximum rating of 120mins, in latched /unlatched condition (if used with deadbolts and pull handles). Labled doors with certification shall be with vision glass as a part of complete assembly. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied shall be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory of approved manufacturer.
a) Door Frame :Door frame shall be Double rebate grooved profile of size 143 x 55mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening.
b) Door Shutter : Door leaf shall be 46mm thick fully flush double skin door, Un-insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware.
c) Infill material: The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 6mm clear borosilicate fire rated glass of relavant rating of the door.
d) Finish: Surface of the frame and shutter shall be cleaned suitably & thoroughly with solvents and as per manufacturer’s specification.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test.
Shutters shall be provided with the following : i) No visible screws or fasteners on either face and Internal reinforcement shall be provided at top, bottom and stile edges for desired fire rating. ii) Factory prepared shutter with pre-punched cutouts and reinforcement pads to receive the approved type and make of Hardware and Iron mongery. iii) Pre-drilled hinge plates with hinge guard covers and shutters with locks to have concealed lock box with lock fixing brackets with pre-tapped holes and screws. iv) Reinforcement pad at appropriate location to receive the hinge, vision panel, flush bolt ,locks, Door closer, Panic Bar, etc. as per the approved type and make of Hardware and all as per manufacturer’s design and conforming to Standards. v) Necessary provision / fixing arrangements shall be provided in the shutter as well as in the frame to receive / fix the Electro magnetic latch, Electro magnetic contact for hooter with reinforcement pads and in such a way to connect the same to the card access control system / IBMS.
e) Installation : The frame and shutter shall be installed in position as per the methodology described in the Technical specification with necessary accessories, tools & Plants etc.
f) Grouting: Frame shall be pressure grouted with cement slurry 1:3 ratio or filling the pre cast solid block core to the frame profile as approved. The surface after grouting shall be neatly cleaned and to be ensured that there is no scratch in the door frames after grouting. Back fill the frame through holes provided and insert plug in type nylon plugs after cleaning the surface and to suit the frame finish and colour.
H) Special Provision : i) Provision / fixing arrangements to be made in the shutter as well as in the frame to receive / fix the Electro magnetic latch, Electro magnetic contact for hooter with reinforcement pads and in such a way to connect the same to the card access control system / IBMS.
iii) All the Materials and hardware specifications proposed for door shall conform to the codes, technical specification and to the bills of quantities. iv) Quoted rate shall be deemed to have considered all the items covered in the specification and drawings, whether explicitly stated or not.
Frames shall be provided with the following : i) Back plates - 3 mm thick on all jambs with provision for anchor bolt fixing to wall openings. ii) Hinge plates 3 mm thick pre-drilled to receive approved type and make of hinges for screw mounted fixing. iii) Factory finish-pre-punched cut outs to receive specified type & make of hardware and iron mongery. All cut outs including hinge plates, strike plates to have mortar guard covers from inside to prevent cement, dust ingress into cut outs at the time of grouting of the frame. iv) Reinforcement pads for fixing of door closer, locks and handles at appropriate location as per manufacturer’s details. v) Plug-in type rubber silencer not less than 2 mm dia shall be provided on the strike jambs for single shutter frames and on the head jambs for double shutter frames. vi) Frames shall be in knock down form with butt joints for bolted assembly at site or as per manufacturers specification with out visible joints/welding marks in frames. vii ) Fire Rated Vision Galss - 200 x300
Single leaf of size : 1200x2400mm including vision panel 200 x 300 mm, Hinges 3090F, 5 Knl, 2 Ball bearing butt hinges size 4" x 3" x 3mm SSS - 4 Nos, Euro profile half cylinder 3005, 42mm Key x Blank, satin finish - Dorma- 1 No, External trim PHT 3905 prepared for euro profile cylinder.- 1 No, Door closer TS 73V EN 2-4 with Std. arm- 1 No, Clear fire rated glass, 6mm, 120min, of size 200 x 300mm- Schott Pyran S- 1 No, Gasket, Fire rated 4mm thick x 13mm, Black- 2 Rmt Fire rated seal for grooved frame profile C421 EPDM Black - Hormann- 6 Rm
Supply and installation of Sliding Door of size 1500 x 2400 mm having thickness of 80 mm with PCGI / PCGI both for cold rooms and ante room etc., Rate to include sliding track, lock, and other accessories etc, complete for finished item of work.
Providing and laying in panels not more than 20 sqm. in plan Granolithic flooring with cement concrete 1:1.5:3 (1 of cement : 1.5 of Manufactured sand : 3 of stone aggregate) by using coarse graded aggregate of 6 to 12 mm size laid monolithic with floor concrete and finished smooth with power trowel including preparation of concrete surface and form work. The screed shall be laid for effective separation of panels not exceeding 20 sqm in plan etc and Unevenness in floor finish shall not exceed +2mm in one squaremetre area. Including sprinkling of Nitoflor Hardtop Standard evenly a shake on a ready mixed non-metallic monolithic floor hardening compound with very hard granulates of mineral origin over concrete floor when the concrete in green and touch dry condition at the rate of 5 Kgs/Sqm. Nitoflor Hardtop Standard shall possess a compressive strength of 50N/mm² as per IS: 516-1959, Moh's hardness not less than 8, as per specification and instructions of the manufacturer. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, pumping, loading, unloading, preparation of surface, ncessary haccking in RCC surface, power trowel, smooth finishing, fixing of screed dtrips, tools and plants, fuel, curing as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
30mm thick
40mm thick
Providing and fixing of flooring with quality approved make of Double charged vitrified tiles - Polished / Matt (seamless joint) confirming to IS 13006/EN 176 Group B1a with techical specification as Mohs scratch hardness minimum 7,Water Absorption of less than 0.5%, Modulus of Rupture greater than 35 N/mm2, Deep Abrasion resistant maximum 175 mm 3 Surface flatness, Straightness of sides ± 0.25%, thickness ± 5% of size of approved colour and size & thick as specified below, set in 20mm thick C.M.1:4(1 cement and 4 manufactured sand ) and pointing with white cement to matching colour shade as per Manufacturer's Specification and as directed. Rate shall include wastages, for preparation of base surface, cleaning, acid wash, and finished surface, protection with Gypsum / Pop layer over Plastic sheet and removing the same before handing over,work at all levels and as directed. Rate shall be inclusive of forming pattern as directed by client / Engineer-in-charge. etc; as complete in all respects and complying with relevant standard specifications and as directed. Size of tiles shall be 600 x 600 x 8mm
Flooring with following antiskid ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three M Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Supply and Laying of Flooring with best quality approved Kotah stone slab not less than 20 mm thick and the size of slab in general not less than 1200 x 600 mm machine cut and machine high pre-polished, set in C.M 1:4 (1 of cement : 4 of manufactured sand ), 20 mm thick topped with white cement slurry (for surface contact of the bottom of the Kotah slab) as per approved pattern/design as per drawing by using irrespective of size and shape, including finishing the joints with white cement slurry, cutting, edge chamfering and polishing rough, medium, nice and acid wash and tin-oxide polish. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, tools and plants, fuel, curing, cleaning, acid wash over finished surface, protection with Gypsum / Pop layer over plastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
Providing and fixing of Anodized Aluminum skirting with 75mm height over partition, columns and walls with all accessories. The screws anchored should be recessed and covered with gaskets. Rate should include Covers at corners & ends, screws, wall chipping, plastering, punning., complete at all levels and heights and as directed by Engineer-in- Charge. Basic cost: Rs 175 / Rmt
Supply and Fixing Dadoing with best quality polished vitrified tile of approved make set in C.M 1:3 (1 of Cement : 3 of manufactured sand) 12 mm thick and pointing the joints with white cementt compound and matching corner tile beading. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, chasing of wall for flushing the tile inline with wall surface, preparation of surface, ncessary haccking in RCC surface, cutting of tiles to required shape, edging, tools and plants, fuel, curing, cleaning, acid wash over finished surface, protection with Gypsum / Pop layer over Plastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. Size of Tile - 300 x 600 x 10mm
Plastering of 12 mm thick for Internal walls with cement mortar 1:4 (1 of cement : 4 of four plastering sand) according to specifications. Rate shall include for providing GI chicken mesh of nominal thickness at the junctions of masonry and concrete works to a width of 100 to 125mm including tying in position with suitable clamps/screws. Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, transportation charges, loading, unloading, preparation of surface, necessary hacking in RCC surface, scaffolding, stagging, tools and plants, fuel, curing, cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
Plastering 10 mm thick for ceiling including slabs, beams and column drops and staircase waist slab, sunshade, drops, chajjas etc..with Cement Mortar 1:3 (1 of cement : 3 of fine P.sand) according to the specification. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds to any size and shape as shown in drawings tools and plants, fuel, curing, cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
Providing two legged scaffolding using 15 cm dia casuarinas post of 4 M over all length (3 M Height + 0.5 M Projection + 0.5 M into the Ground) the distance between the two rows being 1.25 M and the spacing of posts being 2.0 M in both the rows with two horizontal posts with 0.5 M. Overlap on either side and braces at 2.0 M Center to center including longitudinal and transverse middle braces to step up and providing a platform with country wood planks of 40 mm thick and 1 M width, etc. in a complete from using coil and nails.
Upto 3 M Height
For every additional height of 2.5 M Height taking into Consideration - 3 to 6m
Providing and applying two coats of Premium Acrylic Internal emulsion paint, with low VOC as per GS-11, anti fungal and washable of approved colour over a coat of water based primer including preparation of surface by thorough cleaning and applying one coats of premixed putty as per manufacturer’s specification fully to give an even shade before painting and curing as per manufacturers specifications. Rate including all brush, roller, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations, transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
Supply and painting over the existing walls and ceiling surface with 2 coats of first quality cement paint of approved make and colour over one coat of priming coat white colour water proof cement paint. Rate including all brush, ladder, scrapping, washing, materials, labour charges, wastages, cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations, transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
Supplying and painting of 2 coats of weather proof exterior emulsion with high sheen, anti algal properties over one coat wall exterior primer of approved quality and shade etc., complete. Rate including all brush, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations, transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
Supply and Installation of Dry wall partition as shown in the Architectural Drawing to the thickness and height as mentioned below. But generally the partition shall be with GI stud, flooring and ceiling channels with two layer of tapered edge gypsum board (conforming to IS 2095 Part 1 : 2011) fixed with GI studs on both sides. All drywall partitions should have the duty ratings as specified under BS 5234 part 2. The detail specifications and methodology are listed below.
Floor and ceiling channel made of GI steel to be anchored to the floor and true ceiling using HILTI HLC8x40 / HILTI X - GN20MX anchor fasteners at 600mm c/c in zigzag manner. Floor channel to be wrapped with 70μ Self Adhesive LDPE moisture barrier film to further improve corrosion resistance performance. The gaps between floor and flooring channel, true ceiling and ceiling channel should be covered with fire sealant. C stud of 0.5mm thick having one flange of 34mm and another flange of 36mm made of GI Steel to be placed at the spacing specified below, in between floor and ceiling channel. Stud and floor channel are crimped together with crimping tool. Noggin channel of suitable width and 0.5mm thick having two flanges of 40mm each has to be provided at the horizontal joints of outer layer boards screw fixed to the studs using metal to metal flat head screws. 50mm thick Mineral wool or polyester wadding of density not less than 48 kg/m3 shall be placed in metal framework. Holding clip should be used to hold polyester wadding in its position.
The gyp boards are to be fixed with Drywall Screws of 25mm and 50mm at minimum spacing of 300mm at Centre and 150mm at periphery of wall to either side of the stud. The gyp boards to be placed vertically to the framework, with joints staggered to avoid leakage through joints. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Jointing compound confirming to ASTM C 475 and fibre mesh joint tape as per the manufacturer's specifications. Joint finishing to be done for both 1st and 2nd layers of gyp board
All the GI channels and sections should be finished with minimum 120 GSM as per IS 277. Coating with AZ150 as per IS 15961 will be added advantage. All dry wall screws should be made of Carbon steel confirming to EN-ISO 7049/50 and finished with Case hardened Grey Phosphating CLASS 48 as per EN 14566. All metal to metal screws should be made of Carbon steel confirming to EN-ISO 7049/50 and finished with minimum Zinc Coating Thickness of 4.14micron.
Note: 1. The junction of the partition with masonry and all penetration through the partition has to be treated with Hilti/Pyroplex acoustic sealant. 2.Vendor has to submit detail specifications with shop drawing for approval. 3. No Deductions for the horizontal service penetrations. 4. Deductions to be considered for Doors and Windows. 5. Control Joint has to be provided at every 10 Mtr. c/c. along the length of wall. 6. Necessary GI stud backing to be provided for handing the soft board / white board panels. 7. Thickness of partition, size of stud and channel to be as listed below
Rate to include providing GI angle bead at all L-Junctions of partition, Nogging channels at the horizontal joints of each boards, GI stop beads around the door openings, providing necessary GI sections backing / Cutting for switches and sockets, additional supports near the openings, wood inserts for fixing joinery, necessary sound deadening membrane to achieve the required acoustics etc., Quoted rate to be inclusive of all the works mentioned above with standard drywall partitions accessories. Actual laid area from floor to true ceiling will be measured and paid. Working at all levels and heights and as directed by Engineer- in- Charge.
With 94mm floor and ceiling channels and 92mm C stud placed 610mm c/c to a maximum height of 5 meters Skinning - two layers of 12.5mm plain gypsum board with density not less than 640 kg/m3 on both sides. Insulation - 50mm thick Rockwool of density 48 kg/cum wrapped with 40GSM fiber glass tissue in drywall partition with holding clips
Supply and Installation of 122mm thick Two hours fire rated GI stud partition which includes two layer of tapered edge 12.5mm thick Fire rated gypsum board (conforming to IS 2095 Part 1 : 2011 ) of density not less than 750 kgs /m3 fixed with 70mm GI acoustic studs on both sides. All drywall partitions should have the duty ratings as specified under BS 5234 part 2. The detail specifications and methodology are listed below.
Floor and ceiling channel of 72mm width and 0.5mm thick have equal flanges of 32mm made of GI steel to be anchored to the floor and true ceiling using HILTI HLC8x40 / HILTI X - GN20MX anchor fasteners at 600mm c/c in zigzag manner. Floor channel to be wrapped with 70μ Self Adhesive LDPE moisture barrier film to further improve corrosion resistance performance. The gaps between floor / flooring channel, ceiling / ceiling channel should be covered with fire sealant. Acoustic C stud of 0.5mm thick having one flange of 34mm and another flange of 36mm made of GI Steel to be placed at 610mm Centre to Centre in between 72mm floor and ceiling channel. Stud and floor channel are crimped together with crimping tool. Noggin channel of 70mm width and 0.5mm thick having two flanges of 40mm each has to be provided at the horizontal joints of outer layer boards screw fixed to the studs using metal to metal flat head screws. 50mm thick polyester wadding of density not less than 50 kg/m3 shall be placed in metal framework. Holding clip should be used to hold polyester wadding in its position.
The fire line gyp boards are to be fixed with Drywall Screws of 25mm and 50mm at minimum spacing of 300mm at Centre and 150mm at periphery of wall to either side of 70mm stud. The gyp boards to be placed vertically to the framework, with joints staggered to avoid leakage through joints. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Jointing compound confirming to ASTM C 475 and fibre mesh joint tape as per the manufacturer's specifications. Joint finishing to be done for both 1st and 2nd layers of gyp board
All the GI channels and sections should be finished with minimum 120 GSM as per IS 277. Coating with AZ150 as per IS 15961 will be added advantage. All dry wall screws should be made of Carbon steel confirming to EN-ISO 7049/50 and finished with Case hardened Grey Phosphating CLASS 48 as per EN 14566. All metal to metal screws should be made of Carbon steel confirming to EN-ISO 7049/50 and finished with minimum Zinc Coating Thickness of 4.14micron.
Note: 1. The junction of the partition with masonry and all penetration through the partition has to be treated with fire sealant. 2.Vendor has to submit detail specifications with shop drawing for approval. 3.The supplier / manufacturer should inspect the site to ensure that the executed works are adhered to the specification and should submit a guarantee certificate for required fire and acoustic rating. 4. No Deductions for the horizontal service penetrations. 5. Deductions to be considered for Doors and Windows. 6. Control Joint has to be provided at every 10 Mtr. c/c. along the length of wall. 7. Necessary GI stud backing to be provided for holding the soft board / white board panels.
Rate to include providing GI angle bead at all L-Junctions of partition, Nogging channels at the horizontal joints of each boards, GI stop beads around the door openings, providing necessary GI sections backing / Cutting for switches and sockets, additional wood inserts near the openings, necessary sound deadening membrane to achieve the required acoustics etc., Quoted rate to be inclusive of all the works mentioned above with standard drywall partitions accessories. Actual laid area from floor to true ceiling will be measured and paid.
Supply and fixing PUF Panels for Walls, partition Wall - 80mm thickness PCGI / PCGI for cold rooms including all necessary accessories like internal and external Flashing, U Profile, T Suspension with hanging rods, silicon, revets, puf chemical etc., and material and labours charges etc., complete for finished item of work.
Supply and fixing PUF Panels for Flooring of 80mm thickness PCGI / PCGI for cold rooms including all necessary accessories like internal and external Flashing, U Profile, silicon, revets, puf chemical etc., and material and labours charges etc., complete for finished item of work.
Supply and fixing PUF Panels for Ceiling of 80mm thickness PCGI / PCGI for cold rooms including all necessary accessories like internal and external Flashing, U Profile, silicon, revets, puf chemical etc., and material and labours charges etc., complete for finished item of work.
LIFT WATER PROOFING COATING TREATEMENT
1) Lift Surface Preparation The damaged or weaken portion of the concrete shall be removed and the sound RCC slab and wall shall be kept exposed. All Surfaces should be dry and free from contamination such as oil,grease, loose particles,decayed matter,moss,algae growth, laitance,and all traces of mould release oils and curing compounds. Spalled and deeply disintegrated concrete should be removed to sound concrete and repaired with a Fosroc repair system using RenderocS2(or) Renderoc SP40.All the pin holes of RCC slab & wall need to treat with Renderoc FC using up to 3mm All the honeycombs area of RCC slab & wall need to treat with Renderoc S2 (or) Renderoc repairing mortar.
2)Grouting Treatment: Construction joints and other leaking spots in the concrete surface shall be drilled and fixed with 12mm dia heavy PVC pipe nozzles using Renderoc Plug at regular of 1 metre c/c or Depending on the site conditions. It needs to be ensured that the reinforcement is not damaged during drilling holes. The construction joint shall be opened to a size of 20mm x20mm and filled with Renderoc S2 (or) Renderoc S40 (or) Polymer modified comentitious repair mortar using with Nitobond SBR. Cement slurry mixed with Cebex 100 Free Flow non -shrink cementitious Grout shall be used for Grouting @ of 225gms per bag of cement shall be prepared to the required consistency.The prepared slurry shall be injected through the prefixed nozzles under pressure using grout Pump to fill all possible and gaps left within the concrete mass.When the flow of grout stops, or when the grout flows out of adjacent nozzles, mains shall be disconnected, nozzles shall be plugged and allowed to set for 24 hours.
Coving All right angle junction between wall and floors shall be coved with CM1:3 using Nitobond SBR @ 1 litre per bag of cement after priming with cement slurry in 1:1:3 Water. Tie rod Hole packing & inlet / Outlet Pipe Packing Tie rod hole / Bore packing need to be prepared to fill non-shrink grout compound Conbextra GP2 mixed with clean water in the ratio 0.16 after application of Nitobo- -nd SBR in slurry coat mixed with water and cement in ratio 1:1:3 Brushbond TGP Application Saturate the surface with water before application.Mix Brushbond TGP powder single component (15kg) to the clean water (3ltr)in a plastic or metal drum. Mixing is continued lump free slurry is obtained and should be mixed for 10to15 minutes When the concrete surface is damp apply the first coat using aminimim wet film thickness of 1mm apply minimum 24 hours drying.
Brushbond Rfx Application Saturate the surface with water before application. Mix Brushbond Rfx powder component(15kg) to the liquid polymer(5kg)in a plastic or metal drum.Mixing is continued lump free slurry is obtained and should be mixed for 3 to 5 minutes.When the concrete surface is damp,apply the first coat using a trowel a minimum wet film thickness of 1mm (approx.coverage is 1.9kg/m2). First coat should be allowed to cure for a minimum of 5 hours at 20c or 3 hours at 35c. Second coat should also be applied at a minimum wet film thickness of 1mm.Sprinkle the sieved sand on wet surface of final coating for better adhesion of plaster or screed
ELECTRICAL WORKS
CT Metering Panel - Supply, Installation, Testing and Commissioning of CPRI approved make of panel, cubicle type, Free standing, floor mounted, single front, 14 SWG CRCA sheet steel, enclosed separate compartment for each feeder, front operated, Powder coated, indoor type dust and vermin proof, hinged lockable doors, complete with electrolytic grade copper bus bars, internal wiring, colour coding, ferrules, Panel mounting MS Channels, fasteners, etc., RYB indication lamps, internal wirings, Digital voltmeter and Ammeter and other required accessories for the complete operation as per the Tangedco requirements. Necessary approval to be obtained from Tangedco before procurement including all associated control wiring. 1set of 200/5A CT with TNEB metering provision and 1 nos of 200/5A CT for APFC.. For all items in this section, the rate includes necessary supports as required at site. No extra payment will be made for the same. Rate shall inclusive of factory witness test and all accessories, breakers , control wiring, models has to be followed as per in the technical specification. The panel should be erected on Anchor fastners, bolts and nuts for mounting the Indoor Panel as directed by engineer-in charge/department superior engineers.
400A Isolator Panel - Supply, Installation, Testing and Commissioning of CPRI approved make of 400A TPN MCCB panel, cubicle type, Free standing, floor mounted, single front, 14 SWG CRCA sheet steel, enclosed separate compartment for each feeder, front operated, Powder coated, indoor type dust and vermin proof, hinged lockable doors. The rate also includes labour charges and transportation charges etc. The panel should be erected on Anchor fastners, bolts and nuts for mounting the Panel as directed by engineer-in charge/department superior engineers.
APFC PANEL
Supply, erecting, connecting and commissioning of FLOOR Mounted Cubicle type Detuned rector APFC panel with necessary foundation channels etc. INCOMER: 250A TPN MCCB with 36KA(ICS) withstanding capacity of electrically operated. OUTGOING: 200A TPN MCCB with 36KA(Ics) Withstanding capacity with 170AMPS TP Contactors, thermal overload relays. The Coil Voltage shall be 415V AC suitable for connecting 50KVAR Capacitor with ON/OFF illuminated pushbuttons…1No 100A TPN MCCB with 36KA(Ics) Withstanding capacity with 50AMPS TP Contactors, thermal overload relays. The Coil Voltage shall be 415V AC suitable for connecting 25KVAR Capacitor with ON/OFF illuminated pushbuttons…1No 63A TPN MCCB with 36KA(Ics) Withstanding capacity with 40AMPS TP Contactors, thermal overload relays. The Coil Voltage shall be 415V AC suitable for connecting 15KVAR Capacitor with ON/OFF illuminated pushbuttons…2Nos 63A TPN MCCB with 36KA(Ics) Withstanding capacity with 40AMPS TP Contactors, thermal overload relays.
The Coil Voltage shall be 415V AC suitable for connecting 10KVAR Capacitor with ON/OFF illuminated push buttons…2Nos A 12 Steps APFC relay with transducer shall be incorporated to the maintain the power factor. The panel shall also be made suitable to accommodate the following capacitor banks with all interconnections. 50KVAR – 1No 25KVAR – 1No 15KVAR – 2Nos 10KVAR – 2Nos The rate also includes labour charges and transportation charges etc. The panel should be erected on Anchor fastners, bolts and nuts for mounting the Indoor Panel as directed by engineer-in charge/department superior engineers (Make : ABB /C&S/ L&T)
Fabrication, Supply, Erection, Testing and Commissioning of whether proof CRCA sheet steel made up of 2mm powder coated MCCB Indoor Type Three Phase Changer Over Main Panel with suitable to accommodate 400A 4 pole Three phase Change Over Switch-1No. as incomer for EB Source and as incomer for DG Source 2nos of 400A 4Pole MCCB, 1nos of 200A 4Pole MCCB, 5nos of 160A 4Pole MCCB, 2nos of 125A 4Pole MCCB, 7nos of 100A 4Pole MCCB and 1no of 63A 4Pole MCCB's, compartment for as O/G supply with the provisions to accommodate Busbar chamber and cable chamber with size of 33x6mm copper busbar 4 runs having three phase Multifunction meter with line indicators and with all necessary accessories with all other connected works etc. The panel made up of 16/18 SWG CRCA sheet steel comprising of 4 sections with separate sheet steel weatherproof and shock proof safety insulation system conforming to IE Rules with IP protection, and with the panel should be painting by powder coating finishing etc.,as complete and making good of the panel with neat finishing. (Switch make : L & T / ABB) panel should be earthing confirming ISI specifications. The panel should be erected on Anchor fastners, bolts and nuts for mounting the Indoor Panel as directed by engineer-in charge/department superior engineers.
Diesel Generator set with AMF control panel
Supply, Erection, Testing and Commissioning of 320KVA Diesel Generator set with AMF control panel, Diesel Generator Set with acoustic enclosure conforming to CPCB IV+ Norms and BIS Specification comprising of Water cooled CPCB developing @ 1500 RPM and Alternator, complete with type approved canopy and all accessories. with the following technical specification: *Industries most reliable engines, proven over decades. *Low emission, High efficiency. *Compact, robust and rugged design. *Engine Dry type air cleaner *Exhaust Silencer (Residential type) Hospital Grade. *Expansion bellow *Lube oil cooler Lube oil filter (“Spin-on” type) *Fuel Filter (“Spin-on” type) *In line mono block fuel injection pump with Electronic Governor and fuel feed pump. *Dynamically balanced Flywheel with starter ring *Electronic Governor : Governing class G2 (as per ISO 8528 part V) *SAE 1 flywheel housing and flywheel suitable for SAE 14 disc coupling for close coupling of single bearing alternator.
*Exhaust gas turbocharger 24 Volt electric starter motor 24 Volt, 18 amps. Battery charging alternator *Engine instrument control panel consisting of: Engine safety module EMS (KG934) with built in On/Off Bush button. ALTERNATOR 500 KVA, Three phase 415V, 0.8 pf 4 wires 50 Hz at 1500 RPM brushless alternator. The voltage regulation will be 2 phase sensing +/¬ 1 %. The alternators shall be of Class H insulation, enclosure IP 23 and are designed built and tested to IS 4722 or any other equivalent Indian or international standards. Control Panel: 320 KVA DG Set Std Control Panel Consisting of EMS KG934 unit consisting Volt, Amps, RPM, Hz, LLOP, HWT, Low fuel level, over Speed alarm, Over Load alarm, Load imbalance safety alarm, etc. Fuel Tank: 220-275 Letters Capacity inbuilt Battery: 24V DC, 130AH Supply of AMF Control Panel Suitable for 320 KVA DG set for EB Services with byepass arrangement. Exhaust Pipe: Supply and Fixing of 25mtr height Exhaust piping with MS pipe along the wall necessary supports, Flanges, Fasteners, Gaskets, etc (including Thermal insulation with Aluminium sheet wool, mesh,etc,Charges for laying of above Exhaust pipe & Cladding included.
Bed Foundation with M30 Concrete:- Earth Work Excavation at length, width & depth of 20ft x 8ft x 8 ft (8 Cu.ft) and considate the soil at initial stage. Construction of single mat (with minimum of 6mm dia rod) and concrete the base structure at a depth of 1 feet & Height of 4feet using M30 grade concrete (for excavated length and breadth of 8 meter) in the excavated area. Along with this base mat extend with centering slabs for DG footing for 10 feet from the mat with suitable dimention (1 Cu.meter of foundation is exposed in the ground) considering the safe soil bearing capacity at site as 11 T / sq. mtr. and deposting on banks with initial lead of hard stiff clay stiff black cotton soil, hard red earth, shales, muram, gravel, stony earth and earth mixed with small boulders etc., as per SS 20B and as directed by departmental officers. Supply and fixing of foundation bolts with minimum of 1.25 Meter length manufactured from special steel along with necessary nuts, washers, anchor plates and templates with Erection of DG Set. ( Make: Kirlosker, Cummins or equvalent)
Supplying, erecting, connecting and commissioning of 63Amps 4P 30mA RCCB with DOL starter for three phase motor in MS enclosure in an angle iron frame, cable adoptor boxes, interconnections, etc.,
Supplying, erecting, connecting and commissioning of 100Amps 4P 30mA RCCB with DOL starter for three phase motor in MS enclosure in an angle iron frame, cable adoptor boxes, interconnections, etc.,
Supply and fixing of 20A DP plug and socket in sheet enclosure with 32A DP MCB in flush with wall with earth connection complete with all accessories as required as per the site condition. (For AC Plug)
Supply and laying of following XLPE LTUG aluminium armoured cable in a trench / Tray with suitable cable tie tag etc as required.
Supply and laying of 31/2 core x 240 Sq.mm PVC armoured LTUG cable in a trench on surface/ exisiting hume pipe / cable trench / cable tray including all accessories, hardware etc.,
Supply and laying of 31/2 core x 185 Sq.mm PVC armoured LTUG cable in a trench on surface/ exisiting hume pipe / cable trench / cable tray including all accessories, hardware etc.
Supply and Laying of 3 1/2C x 50 sq.mm. PVC armoured LTUG cable in a trench on surface/ exisiting hume pipe / cable trench / cable tray including all accessories, hardware etc .
Supply and Laying of 3 1/2C x 35 sq.mm. PVC armoured LTUG cable in a trench on surface/ exisiting hume pipe / cable trench / cable tray including all accessories, hardware etc.
Supply and Laying of 3 1/2C x 25 sq.mm. PVC armoured LTUG cable in a trench on surface/ exisiting hume pipe / cable trench / cable tray including all accessories, hardware etc.
Supply and Laying of 4C x 16 sq.mm. PVC armoured LTUG cable in a trench on surface/ exisiting hume pipe / cable trench / cable tray including all accessories, hardware etc.
Supply and clamping of following XLPE Aluminium armoured LTUG cable trench or on post or on wall MS-Clamps , Saddles, plugs, Screws etc., as required.
Supply and Clamping of 3 1/2 core x 240 Sq.mm PVC armoured LTUG aluminium cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable.
Supply and Clamping of 3 1/2 core x 185 Sq.mm PVC armoured LTUG aluminium cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable.
Supply and Clamping of 31/2 C x 50 Sq.mm PVC armoured LTUG aluminium cable on post or on wall with MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable.
Supply and Clamping of 31/2 C x 35 Sq.mm PVC armoured LTUG aluminium cable on post or on wall with MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable.
Supply and Clamping of 31/2 C x 25 Sq.mm PVC armoured LTUG aluminium cable on post or on wall with MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable.
Supply and Clamping of 4C x 16 sq.mm. PVC armoured LTUG aluminium cable on post or on wall with MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable.
LT CABLE GLAND
Supply and fixing of double compression brass cable gland for following Aluminium conductor XLPE insulated armoured cable of 1100 V grade with earth connection.
Supply and fixing of brass cable gland for 31/2 C x 240 Sq.mm PVC LTUG armoured cable with earth connection.
Supply and fixing of brass cable gland for 3 1/2 C x 185 Sq.mm PVC LTUG armoured cable with earth connection.
Supply and fixing of brass cable gland suitable for 31/2C x 50Sq.mm PVC armoured LTUG cable with earth connection.
Supply and fixing of brass cable gland suitable for 31/2C x 35Sq.mm PVC armoured LTUG cable with earth connection.
Supply and fixing of brass cable gland suitable for 31/2C x 25Sq.mm PVC armoured LTUG cable with earth connection.
Supply and fixing of brass cable gland suitable for 4C x 16 Sq.mm PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of the following size PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete (copper sockets for copper cables and Alu. Sockets for alum. Cable)
Supply and providing cable end termination of 3 1/2 Core x 240 Sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete.
Supply and providing cable end termination of 3 1/2 Core x 185 Sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete.
Supply and providing cable end termination of 31/2 C x 50sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping with electrical connection complete.
Supply and providing cable end termination of 31/2 C x 35sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping with electrical connection complete.
Supply and providing cable end termination of 31/2 C x 25sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping with electrical connection complete.
Supply and providing cable end termination of 4C x 16 sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping with electrical connection complete.
COPPER CONDUCTOR
Supply and Run of 4 of 6 sq.mm. (84/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe On wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour.
Supply and Run of 2 of 4 sq.mm. (56/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe On wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour.
Supply and Run of 2 Run x 2.5 sqmm PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable Pvc conduit pipe on wall and ceiling and 1R of 1.5sq sqmm continuous earth wire connection with painting of suitable colour.
Light / Fan / Staircase / Plug / Points
Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate continuous earth wire connection by 1.5 sq.mm. copper wire with painting of suitable colour for Open PVC Light point / Fan point (for electronic regulator) ( 4points / Coil) Higher End
Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate continuous earth wire connection by 1.5 sq.mm. copper wire with painting of suitable colour for Open PVC Light point / Fan point (for electronic regulator) ( 6points / Coil) Higher End
Wiring with 2Rx1.5 sq.mm. (22/0.3) PVC insulated Single core unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with suitable Module Plastic Surface mounting switch box on wall with 1no. 6A one way module switch and 1no. 6A 3/2 Pin module socket with module front plate with painting of suitable colour with continuous earth wire connection of 1 run of 1.5 Sq.mm copper wire for Open PVC Conduit Pipe 5A Plug Point ( 8 Points / Coil ) ( Higher End )
Wiring with 2Rx4sq.mm PVC insulated Single core unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module Plastic switch box in flush with wall with 1no. 16A one way module switch and 1no. 16A 3/2 Pin module socket with module front plate with continuous earth wire connection of 4.0Sq.mm copper wire and making good of the concealed portion with painting of suitable colour for Concealed PVC Pipe 15A Power Plug Point ( 8 Points / Coil ) ( Higher End )
SWITCH & SOCKETs
Supply and fixing of 1no.6A two module 5 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Scope cover wall cutting , grouting , flushing and making good on the wall. Higher End.
Supply and fixing of 1 no.6/16A two module socket, 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Scope cover wall cutting, grouting, flushing and making good on the wall. Higher End.
The cable rack shall have runners rugs of suitable size, horizontal elbow, vertical elbow 90 Deg. Up vertical elbow 90 Deg. Down, re-deep, coupler plates, materials. The cable racks shall be suspended from ceiling supported from side walls in columns etc. with adequate size supporting angles / channels with fastners, welding, anchor bolts, nuts etc. The rack shall have suitable cable clamping arrangements etc., Cable Tray /ladder should be powder quoted as match with ceiling colour as per PWD requirements. The rate shall inclusive of necessary Wedge anchors theaded rods,nuts & bolts, making clamp for rcc roof fix / perlin/Truss, cable tray clamps etc, (8 mm threaded rod supports shall be provided at not more than 2 mtr center to center and as per site requirement )
600X50mm lader type Tray
600 X 50mm Perforated type Tray
300X50mm Lader type Tray
300X50mm Perforated type Tray
Supplying and fabricating of MS structural steel supports for various applications using U channels, MS angle iron, bolts, nuts, anchor bolts etc., required for the work, cut to the size, bent to shape, welding, grouting etc., complete. Supports shall be powder coated with required colour for different system as mentioned above.
VERTICAL THREE PHASE INDOOR DISTRIBUTION BOARD WITH MCB : Supply and fixing of 4 way vertical TPMCB sheet steel TPMCB DB with IP42 Protection of surface type fitted with bus bars and neutral links with1 No. of 63A FP MCB as Incoming and 1 No.of 63A,10KA Triple Pole MCB and. 09Nos of 6A to 10A SP MCB for Outgoing in Flush with wall and making good of the concealed portion with earth connection. (TPMCB DB with IP42 Protections)
VERTICAL THREE PHASE INDOOR DISTRIBUTION BOARD WITH MCB : Supply and fixing of 8 way Vertical Indoor TPMCB sheet steel TPMCB DB with IP42 Protection of surface type fitted with bus bars and neutral links with1 No. of 63A FP MCB as Incoming and 5 Nos.of 32A,10KA Triple Pole MCB & 9nos of 6A to 32A SP MCB for O/g., in Flush with wall and making good of the concealed portion with earth connection. (TPMCB DB with IP42 Protections).
Supply and fixing of 7 segment 8 way 63 A FP MCB sheet steel Indoor distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single /three phase MCB outgoings and separate 4 way provision for accommodating one no. 4 pole incoming 63 A FP MCB, 10kA, and another separate 4 way for accommodating one no. 63 Amps 4 pole MCB/ ELCB / RCD (totally 8 ways in one segment) ( 3x6ways in each segment ) and Seperate Provision for MCB / Isolators (totally 18nos) for sub incomers in 3 segments with label holder and provision for taking up cable for size not less than 35 sq.mm. with the following in flush with wall with earth connection only. i.63A 4Pole MCB - 1no. (Incoming) ii.40A 2Pole MCB - 3nos.(Intermediate) ii.32A 2Pole MCB - 8nos (O/g.,) iii.20A SP MCB - 8nos. (O/g.,).
Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 20Amps DP MCB.1 no and 6 nos. 16A SP MCB as outgoing Concealed on wall with earth connection only. Higher End.
Indoor Lights
Supply and Fixing of 4'36w LED fitting with TW round block on wall or ceiling with LED tube with PVC unsheathed FRLS Copper leads from terminals to the fitting. ( Reputed Make like : Philips / Crompton / wipro )
Supply and fixing of 18W LED 3000 K Square type recessed light on wall or ceiling with PVC unsheathed copper leads from terminals to the fitting and to complete necessary accessories and etc to complete the work. Higher End. (Make : Philips / Bajaj / Havells / Crompton )
Supply and fixing of 1200mm (48") sweep AC Ceiling fan 5star rated complete (Higher end) with 2module 100w fan step regulator (Higher end) with 1meter down rod with fan clamp with side plates and cross arm of size 450mm (18").
Supply and Fixing of 375mm (15") sweep ( Heavy duty ) AC Exhaust fan complete with necessary wall opening and making good of the wall.,.
Supply and Fixing of louvers shutters arragements for 375mm (15") sweep ( Heavy duty ) AC Exhaust fan.
Cutting the Existing concrete Road using Diamond Hand Saw capable for cutting to a maximum depth of 250mm with out causing vibration.The rate inclusive of rent and usage charges of Diamond saw cutter machine, labour charges, necessary fuel for running the machine etc complete.
Dismantling the Plain Cement Concrete and clearing away from the same 50m away from the site and roughing the surface etc., complete complying with standard specification and as directed by the departmental officers.
Providing and Laying PCC 1:4:8 (1 of Cement, 4 of M-Sand and 8 of graded metal) using 40mm metal including cost and conveyance of all materials mixing, laying, compacting, curing etc., complete and as directed by the dept. officers.
Supply and filling in foundation and basement with M sand / filling sand in layers of not more than 15cm thick well watered, rammed and consolidated etc., complete as per standard specification.
Supply and fixing of SFRC manhole Cable Chamber of size 750 x750 mm square manhole cover only Using M30 concrete rate includes of excise duty, Transporation charges, all other materials whichever necessary and labour charges etc as directed by the departmental officers.
Supply and fixing of SFRC manhole Earth Chamber of size 450 x450 mm square manhole cover only using M30 concrete rate includes of excise duty, Transporation charges, all other materials whichever necessary and labour charges etc as directed by the departmental officers.
Providing, laying and fixing following 300mm dia RCC pipe NP3 class (Heavy Duty) conforming to IS 458/2003 in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) including cost of pipe as a finished work including all other incidental charges, testing charges including loading, unloading, transport and delivery in good condition at work site etc., complete, as directed by the Departmental Officers, as per standard specifications. and refilling etc as required. 300mm dia.
Supply and Laying in position the best quality and 120mm dia HDPE pipes of ISI mark, providing leak proof joints etc and making connectin to all sanitary fittings, including dismantling masonry / RCC works whereever necessary and making good the dismantled portions to the original condition complying with standard specification.
EARTHING SYSTEM
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 50mm and 2 mtr long earth electrode of low carbon steel rod with 100 micron bonding and 25 kgs of carbon based environment friendly backfill compound and suitable clamp and with copper earth plate of size 125mm x 50mm x 6mm with necessary funnelling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry.
Supply, fabrication, of Copper and GI earth flat & wire of following size in provided trench, clamping in wall, ceiling, with suitable Clamps/ saddles, connecting the joints through bracing / welding covering with termination in the earth pits, Panels, Distribution boards and equipments with bitumen paint including accessories wooden plugs, screws, fastener etc., all inclusive
Supply and run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection.
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection.
Supply and run of 25mm x 6mm GI flat with necessary clamps / supports on wall /floor /ground for earth connection.
Supply and Run of 1 of No.8 SWG GI wire in suitable PVC rigid pipe on wall / floor / ground for earth connection.
FIRE & SAFETY
Supply of First Aid Box complete with all First Aid Medicines.
Supply of Shock Treatment Chart fixed in glass frame.
Supply and fixing of Metallic Danger Board as required by the Electrical Authorities.
Supply of 2m x 1m Rubber Mat suitable for 11 KV installation confirming to IS.
Towards charges for disconnecting the existing Light fittings in First floor Godown and refixing the nearest place. The rate is inclusive of labour charges and all accessories etc., complete.
AC SYSTEMS
Supply, installation, Testing and commisioning of Air-Cooled Condensing Unit with Evaporator unit having cooling capacity of 11.25KW capacity (38500 Btu/hr), scroll hermetic compressor, and R407C-based refrigeration system to maintain the indoor room temperature of (+) 2 to (+) 8 degrees C for fruit and vegetable storage rooms. Complete support, Internal wiring for condender fans , Evaporator fans, Standard length of copper pipes and for finished items of work.
Supply, installation, Testing and commisioning of Air-Cooled Condensing Unit with Evaporator having 16.5KW capacity (56300 Btu/hr) with scroll hermetic compressor and R407C based refrigeration system for maintaining the indoor room temperature of (+) 2 to (+) 8 degree C for Grain storage rooms. Complete support, Internal wiring for condender fans,Evaporator fans,Standard length of copper pipes and for finished items of work.
Supply and installation of Controller for refrigeration units of 16.5 KW & 11.25 KW capacity with complete interal wiring between controller to indoor and outdoor.
Supply Installation, testing and commissioning including vaccumiazation and Nitrogen testing of the following nominal sizes of soft/hard drawn copper refrigerant pipe sizes of 11/8" suction and 5/8" Liquid line for 16.5 KW AC units with complete fittings, supports, jointing/brazing including accessories, insulated with elastomeric nitrile rubber.
Supply Installation, testing and commissioning including vaccumiazation and Nitrogen testing of the following nominal sizes of soft/hard drawn copper refrigerant pipe sizes of 7/8" suction and 1/2" Liquid line for 11.25 KW AC units with complete fittings, supports, jointing/brazing including accessories, insulated with elastomeric nitrile rubber.
Supply and laying of control cable between indoor and outdoor units
Supply,installation,testing and commissioning of UPVC 25mm drain piping complete with fittings, supports as per specifications and duly insulated with 9 mm thick closed cell elastomeric nitrile rubber
Supply of Freon for the ODU units
Supply and erection of powder coated cable tray as per IEC61537 std following sizes ladder type cable tray made out of 2.0mm thick GI sheet secured with GI clamps and brackets with adequate number of supports for pipes every 2.0 mts interval and at bends for Insulated refrigerant pipe.
150mm wide 50mm height
300mm wide 50mm height
450mm wide 50mm height
Supply and erection of powder coated cable tray as per IEC61537 std following sizes Perforated type cable tray made out of 2.0mm thick GI sheet secured with GI clamps and brackets with adequate number of supports for pipes every 2.0 mts interval and at bends for Insulated refrigerant pipe.
150mm wide 50mm height
300mm wide 50mm height
450mm wide 50mm height
Supply,Installation,testing and commissioning of 5.5TR DX-Ceiling mounted ductable split units of specified capacities with R-410A refrigerant gas filling. The indoor units shall be ceiling mounted duct type. The Indoor unit shall comprise of Fan, Cooling coil, Filter and Expansion device. The Outdoor unit shall comprise of inverter scroll / rotary Compressors, Air cooled condenser & Condenser fan. If multiple compressors are offered, they shall have independent refrigerant circuits. Also, compressors shall be cut-off automatically under part load conditions. The units shall have microprocessor controls. The outdoor unit shall be installed in the same floor /Terrace level.
Supply,Installation,testing and commissioning of 1.5 TR DX-inverter type Highwall split unit with R-410A refrigerant gas.The Indoor unit shall comprise of Fan, Cooling coil, Filter and Expansion device. The Outdoor unit shall comprise of inverter scroll / rotary Compressors, Air cooled condenser & Condenser fan. If multiple compressors are offered, they shall have independent refrigerant circuits. Also, compressors shall be cut-off automatically under part load conditions. The units shall have microprocessor controls. The outdoor unit shall be installed in the same floor /Terrace level
Supply Installation, testing and commissioning including vaccumiazation and Nitrogen testing of the following nominal sizes of soft/hard drawn copper refrigerant pipe sizes of 9.5mm suction and 15.9mm Liquid line for ductable /HWS AC unit with complete fittings, supports, jointing/brazing including accessories, insulated with elastomeric nitrile rubber.
Supply and laying of control cable between indoor and outdoor units for Ductable split / Hi wall split unit
Supply and installation of 5 KVA capacity Automatic Voltage Stabilizer with time delay relay
Supply,installation,testing and commissioning of UPVC 25mm drain piping complete with fittings, supports as per specifications and duly insulated with 9 mm thick closed cell elastomeric nitrile rubber
Supply, Fabrication and erection of fabricated ducting made up of GI Sheets of 24 Gauge thickness
Supply and fixing of Flexible Canvas Connection
Supply and providing thermal insulation of 9mm thick Nitrile rubber with Aluminium Foil
Supply and fixing of extruded aluminium powder coated, Supply and return Air Grilles / Diffusers with Volume Control Damper
Supply and fixing of MS stand for fixing outdoor unit
FIRE AND PLUMBING WORKS
HEAVY GRADE, ERW MILD STEEL PIPE : Supply, Installation, Testing & Commissioning of Heavy Class Electric Resistance Welded Mild Steel Pipe manufactured as per IS : 1239 : Part-1 :2004 for pipe size up to 150mm dia and IS : 3589 for pipes greater than 150mm dia with wall thickness of 6 mm. The scope shall include complete factory made FM approved threaded fittings (reducers, elbows, Tees) for sizes up to 50mm dia and Butt weld fittings for dia grater than 50mm. factory-made hangers (Adjustable swivel ring, wire hangers, Clevis hanger, Split ring, Riser clamp, Pipe clamp, universal beam clamps-"C-type", full threaded GI rods, GI nut & Washers, Post-installed anchors etc.), as required to firmly mount on the steel structural members like Beams/slab, concrete ceiling as required at site, miscellaneous consumables and Painting the above ground pipes with one coat of metal primer and two coat of fire red enamel paint of shade No. 536 of IS 5 : 2007. The vendor shall also consider the price for chasing / chipping walls, making bore holes in walls / floor and making them good with filler material and finished in cement mortar etc.
25mm dia
32mm dia
40mm dia
50mm dia
65mm dia
80mm dia
100mm dia
150mm dia
BUTTERFLY VALVE : Supply, Installation, Testing and Commissioning of Dia 100mm Wafer type lever operated Butterfly valve with flanged end connections, C.I disc, S.S shaft, EPDM seat and with necessary accessories, flanges and bolt & nuts. The valves to be manufactured as per standard IS 13095 : 1991. The valve shall be rated for PN1.6 pressure rating.
BALL VALVE : Supply, Installation, Testing and Commissioning of 3-piece, full port, cast iron ball valves with threaded or flanged ends featuring a bottom-loaded blowout proof stem, thrust washer, and adjustable stem packing gland, stem packing nut, cast iron ball, adapter and steel handle with necessary accessories. The valves to be manufactured as per standard IS 9890 : 1981. The valve shall be rated for PN1.6 pressure rating.
25mm DIA
50mm DIA
PENDENT SPRINKLER: Supply,Installation,testing & commissioning of FM approved fast/ Quick response pendent type sprinkler including GI collar for each sprinkler bulb, mounted in MS pipe line using suitable size MS threaded coupling, thread, shellac etc., (Sprinkler Temperature - 79°C (K=80) Fast / Quick response)
FLEXIBLE HOSE PIPE: 1500mm Long Supply, Installation, Testing & Commissioning of 25mm dia stainless steel braided flexible hose pipek, having PN 16 pressure rating and 100 deg Celsius temperature rating with bracket L & S, O-Ring, square bar and all mounting accessories. UL Listed.
ROSETTE PLATE: Supplying and installing of approved type Rosette Plates (Recessed Type in Two Pieces) for sprinklers below false ceiling area. The Rosette shall be fabricated by MS plate of 2mm thick and the finish shall be powder coated and colour, as directed by the Client/Architect/Consultant
REMOVAL AND REFIXING: Removal and Refixing of existing sprinkler pipe , Sprinklers bulb & Internal hydrant system ( 2 Nos) and the sprinkelr pipe tap-off that need to be modified based on the requirement of sprinkler provision. The scope also includes the addition of new MS pipes for Refixing. (Area of Existing sprinkler : 6500 Sq.ft)
Supply and fixing of advanced model multi purpose ABC stored pressure type fire extinguisher, as per International Standard and specifications (IS:15683), Ready to use condition. ISI Marked, Capacity:6 kgs, complete as per standard specification and as directed by the SIDCO Officers. (Five years warranty)
Supply and fixing of CO2 type fire extinguisher, as per International Standard and specifications (IS:15683), Ready to use condition. ISI Marked, Capacity: 4.5 kgs, complete as per standard specification and as directed by the SIDCO Officers. (Five years warranty)
Supply installation & Testing of Floor Mounter Water Dispenser with provision of Hot / Cold / Normal Cooling capacity 3 Ltrs / Hr
Supplying and fixing in position mirror of size 600x450mm of approved quality and brand of size with necessary plastic back, PVC frame with bottom stand of approved color with brass screws, rowel plugs etc., complete complying with standard specification and as directed by the Departmental officers. The quality of mirror should be got approved by the Executive Engineer before use on work.
Supply, Installing, testing and commissioning of 15mm CP health faucet of approved make with necessary CP flexible hose 1000mm long nozzle, CP wall flange etc., (The item rate shall include all costs towards labour, tools, tackles & machineries, all leads & lifts, work related cleaning )
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification.
110m m dia pipe
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
75mm dia PVC Pipe
110mm dia PVC Pipe
Supplying and fixing in position Indian water closet of size 580 x 440mm, glazed earthern ware of approved quality and colour with 'P' trap or 'S' trap confirming to IS:2556-part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One of Lime, Two of Sand, Five of Brick jelly) 100mm thick and by dismantling brick masonry, reinforced finishing to the required slope and including giving necessary connection to PVC soil pipes cement concrete roof / floor slab and making good the disturbed portion to origional condition without leakage etc., complete complying with standard specification and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works)
Supplying and fixing in position Cast Iron Nahini/Floor trap with Stainless steel grating /PVC nahini /Floor Trap with PVC Grating type of size 100x75/75x50 mm with best quality gratings of approved brand fixed over a bed of brick jelly lime concrete 1:2:5(One lime two sand and five aggregate) brick jelly 40mm and finishing with CM 1:3(One cement and three sand) including dismantling masonry wherever found necessary and making good to the original condition and giving connections to the cast iron pipes etc., complete complying with standard specification and as directed by the Departmental Officer
FIRE ALARM SYSTEM (FAS)
Supplying, installing, testing and commissioning of 2 - Zone Conventional Fire Alarm Control panel with 48 hours battery back up for normal operation.
Supply, installation, testing and commissioning of Conventional Smoke Detector suitably mounted on ceiling with MS juction box / false ceiling using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers.
Supply, installation, testing and commissioning of Manual Call Point (MCP) providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers.
Supply, installation, testing and commissioning of Electronic Hooter / Sounder providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers
Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc.,
Supply and fixing of 4 Nos fire bucket made out of 40 x 40 x 6mm with MS angle etc,
Providing and fixing in position the signage of " Fire Extinguisher " to be pasted above the every extinguisher. Size 6" x 8"
Providing and fixing in position the signage of " Manual Call Point " to be pasted above the every MCP. Size 6" x 8"
Providing and fixing Floor indentification signage (i.e, GROUND FLOOR… ETC.,) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5cm with contrasting colour from back ground. Size shall be 15cm * 60cm.
Providing and fixing in position the sign boad of Autoglow " EXIT " with arrow to be placed at walking pathways by hanging on ceiling to direct occupants to outside the building in an emergency. The exit sign board will be auto glow photoluminiscent type which will glow at dark. Size shall be 15cm * 60cm.
CCTV SYSTEM
NVR : Supply, Installation, Testing and commissioning of 32 channel 8 SATA NVR, with 6T Hard Disk Drive 2nos, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected, Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output HDMI1 / VGA1 outputs provided HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface for HDD connection, Support upto 10TB capacity for each HDD, Smart search for efficient playback. and smart playback to improve the playback efficiency, Supports VCA search for fire/ship/temperature/temperature difference detection triggered video files, POS information overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access Hik-Connect for easy network management, 2 Gigabit Ethernet network interfaces. (Make : Hikvision / CP Plus / Dahua / Sony)
DESKTOP: Supply, Installation, Testing & Commissioning of Workstation Intel quad core, minimum i7 series, 4.6Ghz ,8GB of RAM , 2GB Graphics card capable of 1280x1024 pixel resolution and 65K colours , 1 TB Hard disk drive , DVD ROM drive with additional HDMI cards suitable for multifunction operation for dual monitor. All software's loaded shall be genuine and shall be licensed to clients name, for life time.
MONITOR: Supply, Installation, Testing and Commissioning of 42"(107 cm) smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANR h) True colour generator i) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -4sides m) USB -3sides n) Built in LAN o) Magic remote p) Dimension 964 x 662 x 175 with stand (Make: Sony/ LG /Samsung) (Rate as per quotation enclosed)
IP BASED BULLET CAMERA Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification: ●1/2.5" Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behaviour analyses ( Line crossing detection, intrusion detection) ● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied ●On-board Storage - Built-in micro SD/SDHC/SDXC card slot, up to 128 GB, ● Shutter Speed 1/50000 s to 1/15 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 110°, vertical FOV: 59°, diagonal FOV: 131°, ●Lens Mount M16 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ●Operating Conditions: -40 to 140°F / -40 to 60°C up to 90% Humidity
●Environmental Resistance: Weather/Dust/Water-Resistant (IP67) General ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W ● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse. (Make: Hikvision / CP Plus / Dahua / Panasonic)
IP BASED VARIFOCAL LENS DOME CAMERA: Supply, Testing and Commissioning of 5MP Varifocal Motorized Dome IP Camera with following specification: Image Sensor: 1/2.7” Progressive Scan CMOS Effective Pixels: 2592 × 1944 Shutter Speed: 1 s to 1/100,000 s S/N Ratio: ≥52 dB Angle Adjustment: Pan : 0°~360°, Tilt : 0°~77°, Rotation : 0°~360° Video Compression: H.265 / H.264 / MJPEG H.264 Compression: Standard Base Line / Main Profile / High Profile H.265 Compression: Standard Main Profile @ Leve4.1 High Tier Resolution : 5MP(2592×1944), 4MP(2560×1440), 3MP(2304×1296), 1080P(1920×1080),720P (1280×720),D1,CIF, 480×240, 30m IR, MicroSD Slot, Ingress Protection: IP67, Digital Zoom: Yes Image Features: Defog, BLC, HLC, 2D/3D DNR Corridor Pattern: Yes Video Privacy : 4 zones video mask Power Supply: DC12V / PoE Power Consumption: < 9.5W (Make: Tyco /CP Plus / Dahua / Panasonic).
NETWORK SWITCH : Supply, Installation, Testing & Commissioning of 24 port layer 2 switch with 10/100/1000 POE Manage Switches, UL Listed with IP multicast snooping and data-driven IGMP support and with two 1000baseT single mode FO uplink ports, with mounting rack and all related termination accessories as per site specific System requirement.
PATCH CORD: Supply and Installation of cat 24 patch cord for panel side and camera side. Cord length as per site condition.
JACK PANEL: Supply, installation & commissioning of Jack panel loaded with 24 ports in 1U form factor, with universe A/B labelling and 110 connector terminations on rear of panel allowing for quick and easy installation of cable, inclusive of termination accessories as per site specific requirement.
FACE PLATE: Supply and Installation of Information outlet with 2 port 110 style faceplate including accessories.
Supply and fixing of 2 feet CCTV Camera Stand with attachment fittings as follows: * Weather heads and couplings * Cabinet mounting fittings, plates, brackets as needed. * Reinforced couplings for wire entrances to cabinets.
Supply and Installation for 2KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2Hours back up
Supply and Clamping of CAT 6 armoured cable in suitable PVC Pipe 1" thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem) i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal) IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-T IEEE 802.5 16 MB; ISDN; TPDDI; ATM ii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant. Fire Rating: PVC : IEC 60332-1. iii. Conductor - Bare Copper Wire iv. Insulation - Polyethylene v. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm. etc., complete.
Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point ( Point to Point ) Crimping, Testing and arrangement charges.
Supply and Fixing of Rack with Accessories -Higher end 9 U Rack with LNS unit and fan extra for the above rack.
Supply and fixing of 2Nos 6A modular (2 in one 3pin socket) wall socket with control switches and 1 No. 6A/16A 3pin switched socket (16A Switch and Socket combined) with suitable MS modular box covered with Modular 9 module white plate on wall with earth connection (For computer plug socket)
ANNUAL MAINTENANCE CONTRACT (AFTER WARRANTY) - SCHEDULE 'B'
Comprehansive Annual Maintenace (Routine & Preventive) and breakdown maintenance of high side & low side of the Air Conditioning plant and ventilation system comprising of all the machinery & equipments installed in CSB & ESB for four years subsequent to one year free maintenance warranty period as detailed in NIT of Technical Specification for HVAC System. AMC rates are not added in BOQ total value calculation.
AMC of 1st year (Rate only)
AMC of 2nd year (Rate only)
AMC of 3rd year (Rate only)
AMC of 4th year (Rate only)
AADHAVAN ENTERPRISES (BID ID -1266887)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .