GE HADDO
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
REPAIRS / REPLACEMENT / MAINTENANCE OF STREET LIGHTS, HIGH MAST LIGHTS, HIGH BAY LIGHTS, PATHWAY LIGHTS, POST TOP LANTERNS FITTINGS, GARDEN LIGHTS, SOLAR LIGHT FITTINGS INCLUDING ALL CONNECTED ACCESSORIES / ITEMS AT COAST GUARD, TRV AREA UNDER GE HAD
2022_MES_525060_1
8640/E8
Open Tender
Civil Works
Item Rate
270 days
GE HADDO PORT BLAIR
As per tender documents
8 documents required · 8 mandatory
₹500
GE HADDO
₹70,000
Yes
16 Jul 2022
19 May 2022
22 Jun 2022
19 May 2022
15 Jun 2022
3 Jun 2022
20 May 2022 - 28 May 2022
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth, for foundation of poles, stays, struts or for laying cables/pipes etc., not exceeding 10 Sqm on plan and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each as in soils complete all as specified and as directed.
Removing excavated material (soils) to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete for poles/stays/feeder pillar boxes etc., complete all as specified and as directed.
M&L for plain cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in copings of poles/stays including necessary form work, exposed surfaces of concrete finished even and smooth without using extra cement complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 2 core, 6 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., including connecting up with suitable size of lugs, glands and jointing material etc., including taking out old unserviceable cable complete all as specified and as directed. MAKE: POLYCAB / GLOSTER / ANCHOR / HAVELLS / FINOLEX
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 2 core, 10 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., including connecting up with suitable size of lugs, glands and jointing material etc., including taking out old unserviceable cable complete all as specified and as directed. MAKE: POLYCAB / GLOSTER / ANCHOR / HAVELLS / FINOLEX
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 4 core, 16 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., including connecting up with suitable size of lugs, glands and jointing material etc., including taking out old unserviceable cable complete all as specified and as directed. MAKE: POLYCAB / GLOSTER / ANCHOR / HAVELLS / FINOLEX
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3.5 core, 25 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., including connecting up with suitable size of lugs, glands and jointing material etc., including taking out old unserviceable cable complete all as specified and as directed. MAKE: POLYCAB / GLOSTER / ANCHOR / HAVELLS / FINOLEX
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3.5 core, 35 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., including connecting up with suitable size of lugs, glands and jointing material etc., including taking out old unserviceable cable complete all as specified and as directed. MAKE: POLYCAB / GLOSTER / ANCHOR / HAVELLS / FINOLEX
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3.5 core, 50 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., including connecting up with suitable size of lugs, glands and jointing material etc., including taking out old unserviceable cable complete all as specified and as directed. MAKE: POLYCAB / GLOSTER / ANCHOR / HAVELLS / FINOLEX
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3.5 core, 70 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., including connecting up with suitable size of lugs, glands and jointing material etc., including taking out old unserviceable cable complete all as specified and as directed. MAKE: POLYCAB / GLOSTER / ANCHOR / HAVELLS / FINOLEX
M&L for HDPE DWC (Double wall corrugated) pipe of size 40mm (Outer diameter) x 32mm (Inner diameter) along with connected accessories like couplers, bends, end caps etc., laid in trenches/floors/ducts or fixed on poles/walls for as in protection of LT/ HT cable complete all as specified and as directed.
M&L for HDPE DWC (Double wall corrugated) pipe of size 50mm (Outer diameter) x 38mm (Inner diameter) along with connected accessories like couplers, bends, end caps etc., laid in trenches/floors/ducts or fixed on poles/walls for as in protection of LT/ HT cable complete all as specified and as directed.
S&F FRP pole box 140mm x 140mm x 95mm consisting of 50 Amps, 4 pole contactor - 1 No. and MCB, SP, "C" curve, 16 Amps, 10kA - 1No. including taking down the old unserviceable box complete all as specified and as directed. MAKES: FRP pole box: SINTEX Cat Part No. GS-JB-1414 or equivalent in HANSEL MCB: L&T/ HAVELLS/ LEGRAND/INDO ASIAN
S&F timer, heavy duty, 110- 230 Volts, 50Hz with built in sealed rechargeable maintenance free battery 16 Amps, 12 AH capacity having backup of 100 hours, weekly programmable including taking down the old unserviceable timer complete all as specified and as directed. MAKE: INDO ASIAN Cat Part No. TA926453 or equivalent in L&T/ LEGRAND/ HAVELLS
S&F contactor, 3 pole, 415 Volts, 40 Amps, ML-2, 2 NO+NC, heavy duty including taking down the old unserviceable contactor complete all as specified and as directed. MAKE: L&T Cat Part No. SS90701 or equivalent in HAVELLS / INDO ASIAN
LABOUR ONLY for repairing and rectification of faults in security lights / street lights / highbay lights by disconnecting the electrical connections and bringing on ground and refixing the same, back in position after carrying out repairs by checking the peanut lamps/ electrical connections/ electronic drivers etc., and testing after making it fully serviceable by checking the condition of electronic driver and replacing only if required complete all as specified and as directed. NOTES : (i) One Electrician and one helper shall be deputed daily to JE E/Ms office during office hours to ascertain the repairs to be carried out for lights under his AOR. (ii) Electronic drivers, if required to be replaced shall be measured and paid separately as under relevant items of this BOQ as SUPPLY ONLY (iii) Necessary arrangements for carrying out repairs shall be under taken by the contractor.
LABOUR ONLY for repairing and rectification of faults in High mast light fixed at a height of 16m to 32m by disconnecting the electrical connections and bringing on ground by operating existing motor and refixing the same, back in position after carrying out repairs by checking the peanut lamps/ electrical connections/ electronic drivers etc., and testing after making it fully serviceable by checking the condition of electronic driver and replacing only if required complete all as specified and as directed. NOTES : (i) Electronic drivers, if required to be replaced shall be measured and paid separately as under relevant items of this BOQ as SUPPLY ONLY (ii) Necessary arrangements for carrying out repairs shall be under taken by the contractor.
Supply only LED driver suitable for 150 watt LED fittings in High Mast lights complete all as specified and as directed. MAKE: PHILIPS/ CROMPTON GREAVES / HAVELLS / LUKER / C&S (To be provided as per the existing make only)
S&F LED flood light fittings of high power LED, IP 66 protection, toughened glass, 200 Watts capacity, 220 V, 50Hz, pressure die-cast aluminium housing and Class I protection including necessary mounting brackets of suitable size, bolts, nuts and washers as required and fixing on High Mast of 16 Mtr, including taking down old unserviceable one complete all as specified and as directed. MAKE: CROMPTON GREAVES Cart part No.LSFO-200-CDL/60-M / Philips BVP184 LED 19GC W WB 200W PSU or equivalent in / HAVELLS/ C&S/ Philips
S&F LED street light fittings of high power LED, IP 66 protection and integrated optics to ensure uniform light distribution with LED of 50 Watts capacity, 220 V, 50 Hz including necessary brackets of suitable size, bolts, nuts and washers as required and connected by 3 core 2.5 Sqmm multistranded copper conductor of suitable length including taking down the old unserviceable halogen light fitting complete all as specified and as directed. MAKE: C&S Cat Part No : LTESSI50WLED or equivalent in PHILIPS/ CROMPTON GREAVES/ HAVELLS/
S&F LED street light fittings of high power LED, IP 66 protection and unique peanut lens to ensure uniform light distribution with LED of 70 Watts capacity, 220 V, 50 Hz including necessary brackets of suitable size, bolts, nuts and washers as required and connected by 3 core 2.5 Sqmm multistranded copper conductor of suitable length including taking down old unserviceable one complete all as specified and as directed. MAKE: PHILIPS Cart part No.BRP409 LED 074 CW HE MR FG S1 PSU GR or equivalent in OSRAM/ CROMPTON GREAVES/ HAVELLS/ C&S
S&F LED flood light fittings of high power LED, IP 66 protection, toughened glass, 70 Watts capacity, 220 V, 50Hz, pressure die-cast aluminium housing and Class I protection including necessary brackets of suitable size, bolts, nuts and washers as required and connected by 3 core 2.5 Sqmm multistranded copper conductor of suitable length including taking down old unserviceable one complete all as specified and as directed. MAKE: PHILIPS Cart part No.BVP141 LED70 CW FG GR PSU or equivalent in CROMPTON GREAVES/ LUKER/ C&S/HAVELLS
S&F LED flood light fittings of high power LED, IP 66 protection, toughened glass, 50 Watts capacity, 220 V, 50Hz, pressure die-cast aluminium housing and Class I protection including necessary brackets of suitable size, bolts, nuts and washers as required and connected by 3 core 2.5 Sqmm multistranded copper conductor of suitable length including taking down old unserviceable one complete all as specified and as directed. MAKE: PHILIPS Cat No : BVP140 LED 50 CW PC WB 50W 120-270 PSU or equivalent in PHILIPS / HAVELLS/ C&S/LUKER
M&L for preparation of old painted surfaces RCC / steel tubular poles of street lights upto 10.0 metre height by scraping with emery paper and making free from rust, dust and any foreign material and applying one coat of synthetic enamel paint of tint as directed including letter writing such as pole number and source point of electric supply with black paint and fluorescent paint in circumference of poles /mast towers of various heights complete all as specified and as directed.
LABOUR ONLY for repairing and rectification of faults in garden lights/ path way lights by disconnecting the electrical connections and refixing the same, back in position after carrying out repairs by checking the chokes, bulbs etc., and testing after making it fully serviceable by checking the condition and replacing the lamps only if required complete all as specified and as directed. NOTES : (i) Lamps, if required to be replaced shall be measured and paid separately as under relevant items of this BOQ as SUPPLY ONLY (ii) Necessary arrangements for carrying out repairs shall be under taken by the contractor.
Supply only LED bulb, holder type, 7 watts capacity. MAKE: PHILIPS/ BAJAJ/ CROMPTON GREAVES/ HAVELLS
Supply only LED bulb, holder type, 9 watts capacity. MAKE: PHILIPS/ BAJAJ/ CROMPTON GREAVES/ HAVELLS
Supply only LED bulb, holder type, 12 watts capacity. MAKE: PHILIPS/ BAJAJ/ CROMPTON GREAVES/ HAVELLS
M&L for twin core 4 Sqmm stranded aluminium conductor, PVC sheathed and PVC insulated from light fitting to loop-in/ loop-out box including 15mm dia non-metallic rigid PVC conduit medium grade with conduit accessories fixed with saddles along the pole including taking out old unserviceable conductor complete all as specified and as directed. MAKE: FINOLEX/ ANCHOR/ HAVELLS/ GLOSTER/POLYCAB
S&F LED Bollard with round top 9 to 10 Watts, 220V, 50Hz with opal acrylic IP 65 protection along with necessary PCC foundation, 3 core 2.5 Sqmm multistranded copper conductor drawn through and including 25mm dia rigid PVC conduit from one light to other (approx distance 30 metres) with cable connectors including taking down old unserviceable one complete all as specified and as directed. MAKE: CROMPTON GREAVES Cat part No. LBLSN-10-CDL or equivalent in BAJAJ/ HAVELLS/PHILIPS 58167 YOB PEDESTAL / C&S Cat Part No. Canis 10W
S&F LED post top luminaire, outdoor type (Prince opera midi) of 240 Volts, 50Hz, 40 watt capacity, IP 65 protection including mounting on 63mm dia galvanised medium grade pipe of 2.0 metre height from GL with necessary PCC (1:2:4) type B1 foundation and connecting up with and including 3 core 2.5 Sq mm multistranded copper conductor cable drawn through 25 mm dia rigid PVC conduit from one light to other (Approx distance between two posts 30 metres) including taking down old unserviceable one complete all as specified and as directed. MAKE:CROMPTON GREAVES Cat part No. LPTO-40-CDL-M or equivalent in PHILIPS/ C&S Cat Part No. LTGLC40WHPLED/W
Supply only electronic drivers for illuminating 15 to 20 watt LED post top luminaire / LED light fittings operated at input AC voltage 85 to 265 Volts, 50Hz, output DC voltage 42 to 65 Volts, 300MA, P.F > 0.95 complete all as specified and as directed. MAKE: PHILIPS/ CROMPTON GREAVES/ BAJAJ/C&S
Supply only electronic drivers for illuminating 20 to 40 watt LED light fittings operated at input AC voltage 100 to 265 Volts, 50Hz, output DC voltage 36 Volts max, 350MA, P.F > 0.95 complete all as specified and as directed. MAKE: PHILIPS/ CROMPTON GREAVES/ BAJAJ/C&S
M&L for steel tubular swaged poles 410 SP-31 (9.0 metres long) conforming to IS:2713 (Part-I) 1980, welded with mild steel base plate of size 300x300x6mm thick, finial taper plug, bolts, nuts and washers including two coats of aluminium paint over a coat of red oxide primer including taking down old unserviceable pole complete all as specified and directed. Make : Kalinga Tubes / The National Tubes Co/ India Tube & Co
M&L for providing GRP poles of 5.5 meter length including foundation and all fixing arrangement & all accessories all as per OEM recommendation as per direction of Egg-in-Charge. Make : CG/ Havells/ Philips/ C&S/LUKER
Decorative type LED garden light fittings outdoor type IP-66 of size 60 Watts including all fixing arrangement & all accessories all as per OEM recommendation as per direction of Engg-in-Charge. Make : CG Model No. LPTE-60-CDL or equivalent in Havells/ Philips/ C&S/Luker
S&F MCCB, 4 pole, 125 Amps, 50Hz, 16kA rupturing capacity, 415 Volts adjustable type with thermal and magnetic release including taking down old unserviceable one complete all as specified and as directed. MAKE: INDO ASIAN Cat part No. 830243 or equivalent in L&T/ LEGRAND/ HAVELLS
S&F MCB, SP, "C" series, 240 volts, 20-32 Amps, 10kA rupturing capacity including taking down old unserviceable one complete all as specified and as directed. MAKE: INDO ASIAN /L&T/ LEGRAND/ ABB/ HAVELLS
S&F MCB, SPN, "C" series, 240 volts, 40 Amps, 10kA rupturing capacity including taking down old unserviceable one complete all as specified and as directed. MAKE: INDO ASIAN Cat part No. 811152 or equivalent in L&T/ LEGRAND/ ABB/ HAVELLS
S&F MCB, TPN, "C" series, 240 volts, 63 Amps, 10kA rupturing capacity including taking down old unserviceable one complete all as specified and as directed. MAKE: INDO ASIAN Cat part No. 811220 or equivalent in L&T/ LEGRAND/ ABB/ HAVELLS
M&L for 40mm dia or bore galvanised steel tubing, light grade, with all fittings and fixed to walls/poles or laid in floors complete as in protection of cables complete all as specified and as directed. Make: Tata / Jindal / Surya / Prakash
M&L for street light mounting bracket made up of 32mm dia galvanised steel tubing, medium grade, 1.20 metres long, bent to shape with inner angle not less than 120°, with and including necessary fixing clamps fabricated out of angle iron/flat iron of suitable size, bolts, nuts and washers as required and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Supply only LED driver for 100 watt LED fittings in High mast lights complete all as specified and as directed. Make : CG/ Havells/ Philips/ C&S
S&F solar light street fitting of 175 lumen / watt having highly safe & advanced long life, maintenance free lithium ferro phosphate (LiRePO) battery & highly efficient microcontroller with driver and luminaire, having two days battery backup with factory setting dimmer profile, PIR sensor including taking down old unserviceable one complete all as specified and as directed. MAKE: PHILIPS Cat Part No. BRP710 LED20 CW MR S1 12V LFP AIO Solar Equip IN or equivalent in CROMPTON GREAVES/ HAVELLS/C&S
Tropical Refrigeration
M/s Karbhagam Sales Agency
EVEREST COOLING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .