| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | FIRST₹38.9 LAccepted-AOC 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | FIRST | Accepted-AOC BEING LOWEST | |
| 2 | SECOND₹39.4 LRejected-Finance | SECOND | Rejected-Finance BEING NOT LOWEST | |
| 3 | THIRD₹42.5 LRejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | THIRD | Rejected-Finance BEING NOT LOWEST | |
| 4 | FOURTH₹42.6 LRejected-Finance | FOURTH | Rejected-Finance BEING NOT LOWEST | |
| 5 | FIFTH₹42.8 LRejected-Finance | FIFTH | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
17 Jun 2024, 6:00 pmClosed
GE AF MARATHAHALLI
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YEMALUR POST, BANGALORE. PIN- 560037
SPECIAL REPAIR REPLACEMENT OF PCC POLES WITH STEEL TUBULAR POLES AND ALLIED WORKS AT AV CAMP OF ASTE UNDER GE AF MARATHAHALLI
2024_MES_655278_1
8692/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF MARATHAHALLI
AS PER ENIT
7 documents required · 7 mandatory
₹500
Yes
GE AF MARATHAHALLI
₹94,000
Yes
2 Sept 2024
21 May 2024
22 Jun 2024
21 May 2024
17 Jun 2024
4 Jun 2024
Amount
Taking out / down old unserviceable PCC LT pole of any size complete including removal from site all as specified and directed.
Taking down / removing existing junction box / MCBs of any type and capacity complete including removal from site all as directed by Engr-in-charge.
Taking up underground unservicable cable of any size from existing trench / wall / pole including bricks, etc and removing of materials from work site all as directed by Engr-in-charge.
Taking down / removing of existing street light with GI bracket & clamps of any size complete all as specified and directed.
Supply and fix steel tubular swaged poles Type 410SP-31(9.0 meter long) Swan Neck Type complete with CI base plate and finial and single swan neck, Including foundation and coping complete all as specified and directed. Make- India tube and Co/ Kalinga Tubes/Bombay Tubes/India Electric Poles MFG Co/ Singh Profile,Pune
Supply and fixing pole mounted junction box/bus bar chamber for loop connection of street light cable of size 295x195x100 mm with 63 amps aluminium busbar wrapped with PVC sleeves and maintained the colour code and provision of making holes with GI nuts, bolts & washers for connections and mounted on hydrograpic insulators with nuts & bolts at both ends of busbar and suitable arrangement for fixing one no MCB complete all as specified and as directed. Make: Sintex , Cat No: GSJB3020 or equivalent model of Hensel/Rittel.
S&F MCB, Single pole, 6 amps, 240 volts, ‘C’ curve, 10 KA all complete as specified and as directed. (Make : Legrand/ Hager/ABB/Siemens).
M&L for one run of 2.5 Sqmm 3 Core (Nominal Area) PVC Sheathed multi stranded unarmed copper conductor cable LT 1100 volt grade Conforming to IS 7098 FRLS (inner sheet) from pole junction box to light fitting with suitable size copper cable lugs and connector all complete as specified and directed. Make : Plaza/Polycab/Havell's.
Supply and fixing of Endura Cityliner Neo, 60 W LED Street Light fitting pressure die cast aluminium housing, heat resistance toughened glass, IP-66 protection complete all as specified and directed. Make : Bajaj /CG/Philips/Havells
Supply, erection, testing and commissioning KIOSK outdoor type LT feeder pillar box of minimum size 900mm(height) x 600mm (breath) x 500mm (depth) platform mounted, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos copper bus bar for distribution system and type tested at CPRI fabricated .The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate duly compartmentalized for each control gear and bus-bar, double door front door (02 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel angle iron legs of minimum size angle iron 25x3 mm .
The feeder pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947 and including complete internal wiring with 1.5 sqmm copper wire and copper strip/wire from busbar to MCB input and MCB to cable connector of suitable length including PCC (1:3:6) type C-2 as in foundation of suitable size (30 cm below ground level & 40 cm above ground level) including necessary excavation and earth work complete all as specified and as directed alongwith comprising of the following accessories :- NOTE: Rate of earthwork and PCC are deemed to be inclusive in this item. PCC foundation of size as required in cement mortar 1:6 and plastering the same in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed comprising of the following fitment accessories.
BUS BARS AND INTERNAL CONNECTIONS :The bus bars shall be made of Copper strip ,63 Amps rated of minimum length 450 mm wrapped with PVC sleeves and maintained the colour code and provision of making holes with copper nuts, bolts & washers for connections and mounted on hydrograpic insulators with nuts & bolts at both ends of busbar - 04 Nos
OUTGOINGS : (a) MCB TPN of rating 32 Amps having breaking capacity 10 KA - 03 Nos Make : Legrand/Siemens/L&T/ Havells. (b) MCB SPN of rating 25 Amps having breaking capacity 10 KA - 02 Nos. Make:L&T/Legrand/Siemens/Havells (c) Spare pocket for 01 Nos MCB.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables etc getting out and forming bottom surface to required gradient complete all as specified and directed
Excavating in trenches exceeding 1.5 m wide and not exceeding 3 m depth and not less than 1.5 m in width for laying of cables & foundation of poles , stay assembly and getting out in any type of soil complete all as specified and directed .
M&L for PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundations for electric poles, filling and mass concrete complete all as specified and directed.
M & L for PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in coping of the LT poles including form work complete all as specified
M & L for G.I. tubing light grade of size 40mm bore including necessary fiitings for protection of cables to be laid under roads, crossings/culverts complete all as specified and directed.
Material and labour for boring of holes under road, pavement hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe upto 150 mm dia suitable for 0.4 mpa working pressure.
Supply, laying riddled earth soil conformed IS-1255, cushioning to cables with a layer of riddle earth soil 15cm deep before laying the cable and 8 cm depth after laying of cable, complete all as specified.
Brick protection cover on cable with sub class 'B' brick,laid dry and flat adjacent to each other complete all as specified and directed.
Returning filling including spreading levelling watering and well ramming to excavated soil in layers not exc 25 cm thick each complete all as specified.
Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point in soils complete all as specified.
Supply and fixing in repair of Earthing to panel with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4.0mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2020, GI earth lead strip protected by GI pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and directed.
Supply and fixing earth continuity conductor or main galvanised earthing lead wire 4.00 mm dia fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron.
Pacific Enterprises
devan enterprises
V.R.Enterprises
B5BUILDING SOLUTIONS
M/S - KRUPA ELECTRICALS
K T ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .