Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.5 LAccepted-AOC | 1 | Accepted-AOC The lowest tenderer | |
| 2 | 1₹23.6 LRejected-Finance | 1 | Rejected-Finance Not the lowest tenderer |
Tender Value
₹23.5 L
EMD Value
₹47,000
Closing Date
27 May 2020, 3:00 pmClosed
GE NW NAVY NAGAR
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
PROVN OF FIRE ALARM SYSTEM IN MAIN BLDG POL STORE OF SHO AND SPECIAL REPAIRS TO FIRE FIGHTING SYSTEM IN BLDG NO O27 AT NAVY CHILDREN SCHOOL PRIMARY WING UNDER GE NW NAVY NAGAR COLABA MUMBAI
2020_MES_341840_1
8353/E8
Open Tender
Civil Works
Item Rate
180 days
GE NW NAVY NAGAR
As per tender diocuments
7 documents required · 7 mandatory
₹500
GE NW NAVY NAGAR
₹47,000
15 Sept 2020
30 Apr 2020
28 May 2020
30 Apr 2020
27 May 2020
14 May 2020
30 Apr 2020 - 20 May 2020
Amount
Supply and fix hose drum for hose reel of 20 mm size of 30 meter length complete with coupling branch pipe and nozzle , MS sheet 2 mm thickness. Make : Jyoti/ Arihant/ Vijay fire protection
Supply and fix hose reel of 20 mm dia and 30 meter length confirming to IS 5132. Make : Dunlop/ Cease fire/ Vijay fire protection.
Supply and fix branch pipe with nozzle of 20 mm dia for hose reel confirming to IS 8090. Make : Dunlop/ Cease fire/ Vijay fire protection.
Supply and fix 63 mm dia 15 meter long hose confirming to IS 636 complete with male and female coupling confirming to IS 903. Make : Dunlop/ Cease fire/ Vijay fire protection.
Supply an installation, testing & commissioning of Micro processor based 2 wire fault tolerant loop, required loop networkable type 5 Loop (each loop accessing maximum 99 detectors and 99 modules ) fire alarm/detection control panel. The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFF respective control module whenever any alarm is triggered. The panel shall have rectifier, Loop cards, 80 character L C D unit to indicate Fire/Fault Signal with address and analog output. The Panel shall support 24 zones Addressable 2 way Talk Back fire fighter communication, in case of emergency. The panel shall have ability to get integrated with PA System for zone wise announcements. The panel shall support both Loop Powered & conventional Notification devices for emergency responses. the Panel shall support Auto learn feature. The panel should support networking up to 99 panels with maximum distance of 12 Km between 1 & last & 1.5 KM between adjacent panels on RS485. The Panel shall support IP connectivity if required to connect on LAN or WAN network. the panel shall support BMS connectivity through Barnet/ Mod bus The Panel Shall be Sheet Steel Painted, selaed to IP30. The Panel Shall have 24 Zones with Individual Led Indicators, expandable to 80 LED Indicators. The Panel Shall have 3 Serial Ports. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 48 hours with battery charger complete as required. And as per specifications. conforming to BS5839 Standards and Duly Approved by EN54/ LPCB/ VDS/ UL/BSA complete all as specified and directed by Engineer-in-Charge, Voice Alarm controller with USB, MP3, AM/FM player )with 1000 watts Power Amplifier. Make :- Cease fire / Apollo / Hardik Engineer
Supply and fix Detectors Complying with and type certified to EN-45 Addressable type smoke detector Photoelectric / Optical with base with self built intelligence as per IS: 11360 Make :-Cease fire / Apollo
Supply and fix fire hydrant stand post with provn of single outlet confirming to IS 908. Make : Jyoti/ Cease fire/ Arihant.
Supply & fix fire hydrant landing valve type A (single head outlet) of 63 mm dia confirming to IS 5290. Make : Jyoti/ Cease fire/ Arihant.
Supply & fix sluice valve 80 mm size both ends flanged with high tensile stainless steel spindle cast iron body as per IS-14826, ISI Marked,PN-1.6 including all joints with rubber or fibre board, nuts, bolts, washers etc complete all as specified, Make:Kirloskar/Leader/ME ISI Mark
Supply and lay MS Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings of 100 mm
Supply and lay DI Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings of 100 mm.
Supply and fix in repair cast iron body as per IS-14826, ISI Marked, PN-1.0 Non Return valve Flaping type rubber of dia 100mm. Make : Normex/ Kirloskar/ Kartar
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm, 6 core, 1100 Volts grade.
Supply and Install Jockey pump horizontal end suction centrifugal type Confirming to IS- 12469: 1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for automatic operation with nonover loading power characteristics for frequent start / stop operations for 440 V, 3 phase, 50 Hz 70 m head 180 LPM discharge. Make : Kirloskar/ CG/ Cropntion greaves/ Mather and Platt.
S&F PVC water storage Tank 5000 ltr Capacity, hoisting and fixing in position at any location , provision of new tank fittings & connecting it at existing position up to 80 mm GI Pipe connection complete all as specified and directed.
Supply and fix Gun metal fire brigade inlet connection (suction collecting head) consisting of four nos 63mm dia instantaneous type male coupling with built in check valves and 150mm dia sluice valve (one no 150mm dia NRV), and 150mm dia flanged outlet complete with all accessories. Make : Jyoti/ Cease fire/ Arihant.
Supply and fix star delta starter suitable for 20 HP pump set 3-phase,Relay range 14-23 A,Coil volatage 415 V. Make : L&T/ Schnieder/ HPL
Supply and fix in repair hose box for keeping 2 Nos hose pipe of length 15 meter each, branch pipe.nozzle, coupling etc of MS sheet of Thickness 2.0 mm. Make : Jyoti/ Cease fire/ Arihant.
Supply,replacement, Installation,Testing & Commissioning of Addressable Type Manual Call Point with Mounting Base as required confirming (UL's Latest Edition Approved and NFPA compliant / VDS or LPCB tested and EN54 compliant). Make : Appolo/ Cease fire/ Arihant.
Supply & fix in repair twin outlet hydrant valve 100mm having 65mm outlet with lock pin wheel complete all as specified and directed by Engineer-in-charge. Make : Jyoti/ Cease fire/ Arihant.
S&F in repair Sluice Valve 100mm size both ends flayed with high tensile stainless steel spindle, body including all joints with rubber or fibre board, nuts, bolts, washers etc complete all as specified. Make: Kirloskar/ Leader/ L&T(Andco) ISI Mark
Disconnecting suction/delivery pipe from horizontal split casing pump set of capacity 20 HP, disconnecting cable connections and taking out Pump motor of capacity 15 KW, 2900 RPM, 3 Ph, 415 Volt, 50 Hz from Steel yard complex and shift to workshop to carryout repair, dismantle the motor cutting/removing the burnt out winding, cleaning the slots and rewinding the motor with super enamelled copper winding wire of same gauge/turns, heat varnishing, replacing the bearing (1 Pair), shaft assembly and shaft sleeves, reassemble the motor re-fixing the pump set at original position, reconnecting pipe lines and the cable and testing complete all as directed by Engineer-in-charge .
Excavation in trenches not exceeding 1.5 mtr wide not exceeding 1.5 mtr in depth and getting out in soft/loose soil all as specified.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms in any type of soil all as specified.
Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed.
shanti enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .