General Manager, INRP(K)
Office of GM, 608 Building, BARC, Kalpakkam
Supply, Installation, testing and comissioning of 690/1100 (Uo/U), 3-Phase, metal clad, indoor, Power and Motor Control centre (PMCC) switchgear control panels (4 nos.) confirming to IEC-60439-I/61439-I and II, at CWMF, INRP-K, BARC-F, Kalpakkam
2023_BARC_758418_1
BARCF/INRPK-MA/CW/TR/69/2023
Open Tender
Electrical Works
Item Rate
270 days
CWMF/INRPK/NRB/BARC/Kalpakkam
Please refer tender documents
8 documents required · 8 mandatory
₹0
₹1.6 L
4 Sept 2023
22 Jun 2023
11 Aug 2023
23 Jun 2023
4 Aug 2023
4 Jul 2023
26 Jun 2023 - 3 Jul 2023
Amount
Supply, Installation, Testing & comissioning of 690/1100 (U0/U), Panel-1 (Class-IV MCC/PCC Panel, Room No-28), as per the SLD & detailed technical specifications listed in the tender technical specification & as per the instructions of the Engineer-in-charge
Supply, Installation, Testing & comissioning of 690/1100 (U0/U), Panel-2 (Class-III MCC/PCC Panel, Room No-28), as per the SLD & detailed technical specifications listed in the tender technical specification & as per the instructions of the Engineer-in-charge
Supply, Installation, Testing & comissioning of 690/1100 (U0/U), Panel-3 (Class-III MCC/PCC Panel, Room No-70), as per the SLD & detailed technical specifications listed in the tender technical specification & as per the instructions of the Engineer-in-charge
Supply, Installation, Testing & comissioning of 690/1100 (U0/U), Panel-4 (Motor Testing Panel), as per the SLD & detailed technical specifications listed in the tender & as per the instructions of the Engineer-in-charge
Laying, testing & Comissioning of 1.1KV, 3.5C X 400 Sq.mm, Aluminium Conductor, XLPE Insulated, GI armoured, PVC sheathed cables in existing cable trenches, cable trays, building walls etc., as per the scope of the work & as per the instructions of the engineer-in-cherge (Active area)
Laying, testing & Comissioning of 1.1KV, 3.5C X 240 Sq.mm, Aluminium Conductor, XLPE Insulated, GI armoured, PVC sheathed cables in existing cable trenches, cable trays, building walls etc., as per the scope of the work & as per the instructions of the engineer-in-cherge (Active area)
Laying, testing & Comissioning of 1.1KV, 3/3.5C X 185 Sq.mm, Aluminium Conductor, XLPE Insulated, GI armoured, PVC sheathed cables in existing cable trenches, cable trays, building walls etc., as per the scope of the work & as per the instructions of the engineer-in-cherge (Active area)
Laying, testing & Comissioning of 1.1KV, 3/3.5C X 120 Sq.mm, Aluminium Conductor, XLPE Insulated, GI armoured, PVC sheathed cables in existing cable trenches, cable trays, building walls etc., as per the scope of the work & as per the instructions of the engineer-in-cherge (Active area)
Laying, testing & Comissioning of 1.1KV, 3/3.5C X 50 Sq.mm, Aluminium Conductor, XLPE Insulated, GI armoured, PVC sheathed cables in existing cable trenches, cable trays, building walls etc., as per the scope of the work & as per the instructions of the engineer-in-cherge (Active area)
Laying, testing & Comissioning of 1.1KV, 3/3.5C X 25 & below Sq.mm, Aluminium Conductor, XLPE Insulated, GI armoured, PVC sheathed cables in existing cable trenches, cable trays, building walls etc., as per the scope of the work & as per the instructions of the engineer-in-cherge (Active area)
Glanding & end termination of 3.5C X 400 Sq.mm, Aluminium Conductor, XLPE insulated, GI armoured Cable, as per the scope of work & as per the instructions of the engineer-in-charge
Glanding & end termination of 3.5C X 240 Sq.mm, Aluminium Conductor, XLPE insulated, GI armoured Cable, as per the scope of work & as per the instructions of the engineer-in-charge
Glanding & end termination of 3.5C X 185/150 Sq.mm, Aluminium Conductor, XLPE insulated, GI armoured Cable, as per the scope of work & as per the instructions of the engineer-in-charge
Glanding & end termination of 3.5C X 95/120 Sq.mm, Aluminium Conductor, XLPE insulated, GI armoured Cable, as per the scope of work & as per the instructions of the engineer-in-charge
Glanding & end termination of 3.5C X 50 Sq.mm, Aluminium Conductor, XLPE insulated, GI armoured Cable, as per the scope of work & as per the instructions of the engineer-in-charge
Glanding & end termination of 3.5C X 25 or below Sq.mm, Aluminium Conductor, XLPE insulated, GI armoured Cable, as per the scope of work & as per the instructions of the engineer-in-charge
SRS ELECTRICALS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .