Internal Electrification of Building no.101 and other Infrastructure Buildings at FRFCF, Kalpakkam
2023_BARC_772381_1
BARC/NRB/FRFCF/ELE/TR-030/2023
Open Tender
Electrical Works
Item Rate
365 days
FRFCF, KALPAKKAM
Please refer tender document
8 documents required · 8 mandatory
₹0
₹1.6 L
20 Oct 2023
20 Sept 2023
5 Oct 2023
20 Sept 2023
30 Sept 2023
20 Sept 2023
20 Sept 2023 - 25 Sept 2023
Amount
Supply, Open installation testing and commissioning of 8 Way TPN DB, IP 43 - IK 09, with Metal Double Door consisting of Phase, Neutral and Earth Bus and interconnecting wires (PPI Kit) and Cable End Box. (MS item will be measured separately). (Refer Sec VI, Clause No.15.2).
Supply and installation of Surface mounting Powder Coated TPN 250A,3ph,415V,50Hz, 12Way Vertical DB with 1no of I/C-4P, 250A MCCB and 12 no's of O/g's-3P, 63A MCB with all accessories as per the scope of work.
Supply, Installation, testing and commissioning of the following MCBs/RCBOs on Distribution Boards as per the detailed specification. (Refer Sec VI, Clause No.14.2).
6-32 Amps SP MCB (Type-C)
6-32 Amps DP MCB (TYPE-C)
40-63Amps, DP MCB (TYPE-C)
RCBO FP 40A sensitivity 30mA 4Module
RCBO FP 63A sensitivity 30mA 4Module
Supply and external installation of 25mm dia 1.8mm wall thickness Heavy Duty, Hot Dip Galvanised MS ERW Conduits with 50mm deep junction boxes, for Electrical & Communication System with all the required accessories like round JBs, Solid Long Bends, Check Nuts, Nipples, Couplings, Reducers, Copper Clips, Copper Conductor, GI Wire etc. as per the detailed specification. .(Refer Sec VI, Clause No.27).
Wiring for lights/fans/sensors/Timer/Power point with 1100V grade FRLS insulated copper conductor wires in existing concealed/Exposed ERW hot dip GI conduits as per the detailed scope of work, including supply of Wires, switches/sockets, termination of copper wires at both the ends by crimping, including supply of rubber bushes, PVC Sleeves/Ferrules, Copper Crimping Lugs and connecting the wires to various switches, sockets, etc. including testing and commissioning as per the detailed specification.(Refer Sec VI, Clause No.18).
Wiring for Light/Sensor/Fan Points with 2 Runs of 1.5 Sq.mm copper wires for Phase & Neutral and 1 Run of 2.5 Sq.mm copper wire for Earth from MCB Distribution Board to Primary light/sensor/fan point through Control Switch Box including 10Amps modular switch. (Average Length 23Mtrs)
Wiring for Light point with 2 Runs of 1.5 Sq.mm Copper wires for Phase & Neutral and 1 Run of 2.5 Sq.mm Copper wire for Earth from Switch box to switch box and further to Light point including 1 No 10A modular switch.(Average Length 14Mtrs)
Wiring for Light point with 2 Runs of 1.5 Sq.mm Copper wires for Phase & Neutral and 1 Run of 2.5 Sq.mm Copper wire for Earth from Switch box to Light point/Ceiling fan including 1 No 10A modular switch. (Average Length 9Mtrs)
Wiring for Light point with 2 Runs of 1.5 Sq.mm Copper wires for Phase & Neutral and 1 Run of 2.5 Sq.mm Copper wire for Earth from Light point to Light point /sensor/contactor. (Average Length 4Mtrs)
Wiring for Light point with 2 Runs of 4 Sq.mm Copper wires for Phase, Neutral and 1 Run of 2.5 Sq.mm copper wire for earth from Distribution Board to Light point through MCB Switch Box including supply of one No. of 10A SP MCB (more than 5.5 meter height). (Average Length 28Mtrs)
Wiring for Light point with 3 Runs of 2.5 Sq.mm Copper wires for Phase, Neutral and Earth from Light point to Light point (more than 5.5 meter height) (Average Length 19Mtrs)
Wiring for Power point with 3 Runs of 2.5 Sq.mm Copper wires for Phase & Neutral and Earth from MCB Distribution Board to Power point through Control Switch Box including supply of 16A modular switch, 6/16 Amps combined shuttered type Socket, 3Modular plate 1No. (Average Length 18Mtrs)
Wiring for Power point with 3 Runs of 2.5 Sq.mm Copper wires for Phase, Neutral and Earth from MCB Distribution Board to Power point through Control Switch Box including supply of modular plate, one No. of 16A modular switch & one No. of 6/16 Amps combined shuttered type Socket and Three Numbers of 10A modular switch & Three numbers of 3 pin, 6A shuttered type Socket, Modular plate. (Average Length 17Mtrs)
Wiring for Power point with 2 Runs of 1.5 Sq.mm copper wire for Phase & Neutral and 1 Run of 2.5 Sq.mm copper wire for Earth from MCB Distribution Board to Power point through Control Switch Box including 10A modular switch, 3 pin 6A shuttered type Socket, Module Plate. (Average Length 20Mtrs)
Wiring for Power point with 3 Runs of 2.5 Sq.mm Copper wires for Phase & Neutral and Earth from MCB Distribution Board to Power point through Control Switch Box including supply of 16A Starter switch, 6/16 Amps combined shuttered type Socket, 2 Modular plate 2 Nos. (Average Length 7Mtrs)
Wiring for Power point with 3 Runs of 2.5 Sq.mm Copper wires for Phase & Neutral and Earth from MCB Distribution Board to Power point through Control Switch Box including 16A modular switch, 6/16 Amps combined shuttered type Socket and 10A modular switch & 3 pin, 6A shuttered type Socket, Modular Plate. (Average Length 32Mtrs)
Wiring for Power point with 3 Runs of 2.5 Sq.mm Copper wires for Phase & Neutral and Earth from Control Switch Box to control switch box including supply of 16A modular switch, 3 pin 6/16 A combined shuttered type Socket, Modular plate. (Average Length 10Mtrs)
Wiring for Power point with 2 Runs of 1.5 Sq.mm Copper wires for Phase & Neutral and 1 Run of 2.5 Sq.mm copper wire for earth from Control Switch Box to control switch box including 10A modular switch & 3 pin 6A, shuttered type Socket, Modular plate. (Average Length 2Mtrs)
Wiring for Power point with 3 Runs of 2.5 Sq.mm Copper wires for Phase & Neutral and Earth from Control Switch Box to control switch box including 10A modular switch & 3 pin 6A, shuttered type Socket and 16A modular switch & 6/16A combined shuttered type Socket, Modular plate. (Average Length 41Mtrs)
Wiring for Exhaust fan point up to 3 Mtr height with 2 Runs of 1.5 Sq.mm Copper wires for Phase & Neutral and 1 Run of 2.5 Sq.mm Copper wire for Earth from Switch board to Power point including supply of 3 pin 6A shuttered type Socket, 2Nos. 2 Modular plate and 1 No 10A modular switch. (Average Length 7Mtrs)
Wiring for fan point with 2 Runs of 1.5 Sq.mm Copper wires for Phase & Neutral and 1 Run of 2.5 Sq.mm Copper wire for Earth from Switch box to Fan point including 1 No 10A modular switch and 1 No step type Fan regulator. (Average Length 7Mtrs)
Wiring for lights / fans /sensors/ Power point with 1100V grade FRPVC insulated copper conductor wires in existing concealed/ Exposed PVC / ERW/Flo-coated Metal conduits as per the detailed scope of work, including supply of Wires and termination of copper wires at either end by crimping including supply of PVC Sleeves/Ferrules, Copper Crimping Lugs and connecting the wires to various switches, sockets, etc. including testing and commissioning as per the detailed specification.(Refer Sec VI, Clause No.18).
Wiring with 1 Run of 1.5 Sq.mm Copper wire
Wiring with 1 Run of 2.5 Sq.mm Copper wire
Supply and Embedment of 50mm Deep, Square/Rectangular Concealed type and GI double earthed modular metal boxes of the following types and as specified in RCC/Brick/Concrete Block Masonry with finishing and making good as per the detailed specification. (Refer Sec VI, Clause No.15.12).
1/2 Module
3 Module
4 Module
6 Module
8 Module rectangular
12 Module
Supply and fixing of following front Modular cover plate on existing modular metal/plastic boxes etc. as required. (Refer Sec VI, Clause No.15.7).
1/2 Module
3 Module
4 Module
6 Module
8 Module rectangular
12 Module
1 Modular dummy plate
Supply and embedment of concealed type MS boxes of the following types and as specified in RCC/Brick/Concrete Block Masonry with finishing and making good as per the detailed specification. (Refer Sec VI, Clause No.15.10).
150(W)X150(H)X80(D)mm, 1.6mm thick sheet MS Box
200(W)X200(H)X120(D)mm,1.6mm thick sheet MS Box
300(W)X300(H)X120(D)mm,1.8mm thick sheet MS Box
Supply, transportation, installation, testing and Commissioning of the following type of Recess mounted luminaires. (Refer Sec VI, Clause No.16.1).
20W, 2*2 feet Recess Mounted LED Luminaires with CCT of 6500K, variation in CCT within 7 steps, having a minimum CRI of 80, lumen output of minimum 2500, minimum lumen efficiency of 110 lm/w, ingress protection minimum of IP20, and impact resistance of min IK-05 having THD of less than 10% in pressure die-cast aluminium housing, etc., with a suitable current control driver circuit and complete with all accessories including mounting arrangements with provision and connection for 2.5 sq.mm flexible copper conductor of PVC insulation wire, etc., as per the detailed specification and instruction of Engineer-in-Charge.
30W, 2*2 feet Recess Mounted LED Luminaires with CCT of 6500K, variation in CCT within 7 steps, having a minimum CRI of 80, lumen output of minimum 3600, minimum lumen efficiency of 110 lm/w, ingress protection minimum of IP20, and impact resistance of min IK-05 having THD of less than 10% in pressure die-cast aluminium housing, etc., with a suitable current control driver circuit and complete with all accessories including mounting arrangements with provision and connection for 2.5 sq.mm flexible copper conductor of PVC insulation wire, etc., as per the detailed specification and instruction of Engineer-in-Charge.
40W, 4 feet Recess Mounted LED Luminaires with CCT of 6500K, variation in CCT within 7 steps, having a minimum CRI of 80, lumen output of minimum 4300, minimum lumen efficiency of 110 lm/w, ingress protection minimum of IP20, and impact resistance of min IK-05 having THD of less than 10% in pressure die-cast aluminium housing, etc., with a suitable current control driver circuit and complete with all accessories including mounting arrangements with provision and connection for 2.5 sq.mm flexible copper conductor of PVC insulation wire, etc., as per the detailed specification and instruction of Engineer-in-Charge.
12W Recess Mounted LED Luminaires with CCT of 6500K, variation in CCT within 7 steps, having a minimum CRI of 80, lumen output of minimum 1200, minimum lumen efficiency of 110 lm/w, ingress protection minimum of IP20, and impact resistance of min IK-05 having THD of less than 10% in pressure die-cast aluminium housing, etc., with a suitable current control driver circuit for 110/220V DC and complete with all accessories including mounting arrangements with provision and connection for 2.5 sq.mm flexible copper conductor of PVC insulation wire, etc., as per the detailed specification and instruction of Engineer-in-Charge.
Supply, transportation, installation, testing and Commissioning of the following type of Surface mounted luminaires.(Refer Sec VI, Clause No.16.1).
40W, 4 feet Surface Mounted LED Luminaires with CCT of 6500K, variation in CCT within 7 steps, having a minimum CRI of 80, lumen output of minimum 4300, minimum lumen efficiency of 110 lm/w, ingress protection minimum of IP20, and impact resistance of min IK-05 having THD of less than 10% in pressure die-cast aluminium housing, etc., with a suitable current control driver circuit and complete with all accessories including mounting arrangements required to mount on wall/ suspended from 5 meter ceiling with provision and connection for 2.5 sq.mm flexible copper conductor of PVC insulation wire, etc., as per the detailed specification and instruction of Engineer-in-Charge.
10W, 2 feet Surface Mounted LED Luminaires with CCT of 6500K, variation in CCT within 7 steps, having a minimum CRI of 80, lumen output of minimum 1200, minimum lumen efficiency of 110 lm/w, ingress protection minimum of IP20, and impact resistance of min IK-05 having THD of less than 10% in pressure die-cast aluminium housing, etc., with a suitable current control driver circuit and complete with all accessories including mounting arrangements required to mount on wall/ suspended from 5 meter ceiling with provision and connection for 2.5 sq.mm flexible copper conductor of PVC insulation wire, etc., as per the detailed specification and instruction of Engineer-in-Charge.
SCEL 9/12W Surface Mounted, Portable non-maintained emergency LED Luminaires with CCT of 6500K, variation in CCT within 7 steps, having a minimum CRI of 80, lumen output of minimum 1200, minimum lumen efficiency of 110 lm/w, ingress protection minimum of IP20, and impact resistance of min IK-05 having THD of less than 10% in pressure die-cast aluminium housing with minimum 8hrs battery back-up, etc., with a suitable current control driver circuit and complete with all accessories including mounting arrangements required to mount on wall/ suspended from 5 meter ceiling with provision and connection for 2.5 sq.mm flexible copper conductor of PVC insulation wire, etc., as per the detailed specification and instruction of Engineer-in-Charge.
100W, Wall/Surface Mounted LED Luminaires with CCT of 6500K, variation in CCT within 7 steps, having a minimum CRI of 80, lumen output of minimum 10000, minimum lumen efficiency of 110 lm/w, ingress protection minimum of IP20, and impact resistance of min IK-05 having THD of less than 10% in pressure die-cast aluminium housing, etc., with a suitable current control driver circuit and complete with all accessories including mounting arrangements required to mount on wall/ suspended from 5 meter ceiling with provision and connection for 2.5 sq.mm flexible copper conductor of PVC insulation wire, etc., as per the detailed specification and instruction of Engineer-in-Charge.
Supply, transportation, installation, testing and Commissioning of 26W, Suspended LED Luminaires with CCT of 6500K, variation in CCT within 7 steps, having a minimum CRI of 80, lumen output of minimum 2800, minimum lumen efficiency of 110 lm/w, ingress protection minimum of IP20, and impact resistance of min IK-05 having THD of less than 10% in pressure die-cast aluminium housing, etc., with a suitable current control driver circuit and complete with all accessories including mounting arrangements required to mount on wall/ suspended from 5 meter ceiling with provision and connection for 2.5 sq.mm flexible copper conductor of PVC insulation wire, etc., as per the detailed specification and instruction of Engineer-in-Charge.(Refer Sec VI, Clause No.16.1).
Supply, transportation, installation, testing and Commissioning of 40W, LED luminaries on Metalic poles with CCT of 6500K, variation in CCT within 7 steps, having a minimum CRI of 80, lumen output of minimum 2800, minimum lumen efficiency of 110 lm/w, ingress protection minimum of IP20, and impact resistance of min IK-05 having THD of less than 10% in pressure die-cast aluminium housing, etc., with a suitable current control driver circuit and complete with all accessories including mounting arrangements requiredon Metalic poles of height from 2.5 M to 4 M with provision and connection for 2.5 sq.mm flexible copper conductor of PVC insulation wire, etc., as per the detailed specification and instruction of Engineer-in-Charge.(Refer Sec VI, Clause No.16.1).
Supply, Installation, testing and commissioning of 1200mm Sweep AC ceiling fan and safety steel rope with 3 Core, 1.5 Sq.mm (14/0.3) flexible copper cable including earth connection. Supply and fixing of regulator is not included in the scope of this item. (Refer Sec VI, Clause No.17.1).
Supply, installation, testing and commissioning of 300 mm Dia Wall Mounting Exhaust Fans including supply of Aluminium grill bracket with Stainless Steel Bolts for mounting of Exhaust Fan & Aluminium grill bracket and 3 Core, 1.5 Sq.mm (14/0.3) PVC insulated & FRLS sheathed copper flexible cable of required length as per the detailed specification. (Refer Sec VI, Clause No.17.2).
Supply, testing and commissioning of 400mm Sweep Pedestal Fans as per the detailed specification and instruction of Engineer-in-Charge. (Refer Sec VI, Clause No.17.3).
Supply and installation of following sizes of Copper Earthing Conductor in Walls, Floors, Built in Trenches including supply of GI spacer and clamps, fixing fasteners etc as per detailed specification. (Refer Sec VI, Clause No.12.5).
70 Sq.mm multi Stranded tinned copper conductor with test link
185 Sqmm multi Stranded tinned copper conductor with test link
Supply & Installation of 185 Sqmm multi Stranded tinned Copper Earthing Conductor direct in ground including excavation, and back filling the trench as per detailed specification. (Refer Sec VI, Clause No.12.5).
Supply and installation of the 8 SWG copper wire in built in trench as per the detailed specification.(Refer Sec VI, Clause No.12.8).
End Termination of the following sizes of annealed, tinned, stranded Copper conductor including supply of copper crimping lugs etc. (Refer Sec VI, Clause No.12.6).
70 Sqmm stranded tinned Copper conductor
185 Sqmm stranded tinned Copper conductor
Jointing of following size of the Copper bonded steel round conductors by Exothermic Welding (CAD Welding) joint complete with all components and accessories as per the scope of work and drawings.
Cross (+) -Type joint 70 Sq.mm conductor
T -Type joint 70 Sq.mm conductor
T -Type joint 185 Sq.mm conductor
Supply installation and testing of Maintenance free earthing system (1x10feetx5/8inch copper bonded steel rod, 22 kg Ground Enhancing Material (GEM) ) as per IS: 3043 including RCC Chamber and RCC cover slab as per Drawing No.IGC/ESD/5060/1008/1 enclosed. (Refer Sec VI, Clause No.12.12).
Supply, installation, testing and commissioning of SDFU TPN 63A, DIN FUSES with 3Nos 63A HRC fuse links, Sheet steel factory made enclosure with MS frame work as per the scope of work. (MS item will be measured separately). (Refer Sec VI, Clause No.14).
Supply Embedment Assembling testing and commissioning of following type Metra plug and socket DB and RCBO in sheet steel enclosure including chipping and finishing as per the detailed specification. (Refer Sec VI, Clause No.15.4).
16A 2P+E-DP Metra plug and socket DB and 16A DP 30mA sensistivity RCBO
32A 3P+N+E-FP Metra plug and socket DB and 32A FP 30mA sensistivity RCBO
63A 3P+N+E-FP Metra plug and socket DB and 63A FP 30mA sensistivity RCBO
Supply and installation of 150 mm Dia. 2 Mtrs Long, NP 2 Class Hume Pipes Direct in ground at a depth of 1200 mm including supply of Collars and fixing them with1:1 cement mortar and curing, including excavation in all types of soil, backfilling complete as directed by Engineer-in-Charge. (Refer Sec VI, Clause No.8.1).
Excavation of soil including refilling with excavated earth and disposing surplus earth at places as directed with in a lead of 10 Mtrs. and initial lift upto 1.5 Mtrs. including neat banking as per detailed specification. (Refer Sec VI, Clause No.2).
Supply & laying of 1 pair, 1.5 Sq.mm twisted pair stranded annealed copper conductor, PVC insulated Class-A, flexible un-armoured FRLS cable
Supply & Laying of 1 Pair, 1.5 Sq.mm Stranded annealed copper conductor, flexible un-armoured cable, FRLS PVC sheath, insulated cores, twisted pair, overall screened with Al-Mylar tape, voltage grade 1100V, and applicable standard IS 1554.
Laying of CAT-6 Cable through embedded conduit/casing-capping for Telephone system, CCTV System and LAN System
SP Enterprises
UK ELECTRICALS
THIRUMALAI ELECTRICALS
RR ENTERPRISES
EC Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .