Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.5 CrAccepted-AOC C 709 VARDHAMAN APARTMENT MAYUR VIHAR I DELHI 110091 INDIA | EAST | DELHI | 110091 | ₹16.5 Cr | 1 | Accepted-AOC Being L1 bidder |
| 2 | 2₹17.7 CrRejected-Finance SITANI BUILDING DINBAZAR JALPAIGURI 735101 | JALPAIGURI | JALPAIGURI | WEST BENGAL | 735101 | ₹17.7 Cr | 2 | Rejected-Finance Being other than L1 |
| 3 | 3₹19.0 CrRejected-Finance BHAGWATI BHAWAN PO HASIMARA DIST JALPAIGURI PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | ₹19.0 Cr | 3 | Rejected-Finance Being other than L1 |
| 4 | 4₹19.1 CrRejected-Finance | ₹19.1 Cr | 4 | Rejected-Finance Being other than L1 |
| 5 | 5₹19.2 CrRejected-Finance PO HASIMARA NEW MARKET DISTT ALIPURDUAR STATE WEST BENGAL PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | ₹19.2 Cr | 5 | Rejected-Finance Being other than L1 |
Tender Value
₹17.9 Cr
EMD Value
₹12.2 L
Closing Date
29 Oct 2020, 6:00 pmClosed
CE (AF) SHILLONG ZONE
HQ CE (AF) SHILLONG ZONE, ELEPHANT FALLS CAMP, PO-NONGLYER, SHILLONG-793009
PROVN OF IGLOO TYPE DBs AT AF STN HASIMARA
2020_MES_349370_1
88363/HAS/E8
Open Tender
Civil Works
760 days
HASIMARA
AS PER NIT
7 documents required · 7 mandatory
₹3,000
GE (AF) HASIMARA
₹12.2 L
Yes
5 Nov 2020
3 Jun 2020
3 Nov 2020
3 Jun 2020
29 Oct 2020
15 Oct 2020
3 Jun 2020 - 30 Jun 2020
Amount
NOTE (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
SCHEDULE "A" Part - I (BUILDING / STRUCTURES WORK ) Details of pre priced schedule is given in tender documents
SCHEDULE "A" PART-II (SITE CLEARANCE, EARTH WORK AND EXCAVATION ) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-III (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (ROAD/PATH/CULVERT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IX (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-X (LIGHTENING PROTECTION) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-XI (FENCING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XII (PELLETS FOR STORAGE OF CONTAINER) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIII (DANGER BOARD) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIV (AIR CONDITIONING) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' 5 ' signifies this fact only.
Supply, Installation, Testing and Commissioning of Chilled water Central Air-conditioning system of capacity not less than 60 TR (2x30 TR working and 1X30 TR standby ) including following items and other items as required for satisfactory performance of the plant complete in all respect for IGLOO Type DBs all as specified in respective drawings to achieve the inside design conditions as per ANNEXURE ‘A’ and details as per ANNEXURE 'A-1' enclosed here-in-before :- Note 1 :- (a) Contractor / bidder needs to check the desired inside design conditions carefully and submit the bid only after ascertaining the capacity of the AC plant required to achieve the inside design conditions. (b) Contractor / bidder should submit complete design for the Central AC plant comprising of heat load calculations, working drawings of complete AC plant supported with design/ calculations of each component duly vetted by IIT/NIT within two months of the date of commencement of work through GE for the approval of Accepting Officer before execution of the work. (c) Contractor/bidder will be responsible for performance guarantee of complete AC plant to achieve the inside design conditions round the clock throughout the year with overall COP of the system not less than 3. (d) Design, Supply, Installation, Testing and Commissioning of Chilled water Central Air-conditioning system shall be undertaken through Manufacturers/ Specialist Firms. Note 2 :- Rates quoted by the contractor shall be complete finished work including cost of all labour, material, scaffolding, finishing as required with tools, plants, cartage, lift, taxes, tollage, octroi, royalties etc. All works shall be executed as per drawings and instructions of Site-in-charge and shall include the supply and installation at site of all the equipment, ancillary materials as specified and all such items what-so-ever which may be required to fulfill the intent and purpose as laid down in the drawings. All materials shall be as per ISI specification and with IS certification marked wherever applicable. The material shall be duly approved by Site in-charge before incorporation in the actual work.
S&F of flowchart based programmable Remote Terminal Unit along with battery backup minimum 30 minutes for power fail SMS to Engineer-in-Charge complete with the following :- - Input output as per requirement in system - 3 Serial Port - Digital Inputs (Optical isolation) - Digital outputs - Isolated Analog inputs for monitoring of Temperature & humidity - Local Display, membrane key board and data storage - Compatibility with GSM Modem Make : Cimcon / Safetek/Powertek (To be installed at Central Chiller plant but outside the storage building)
S&F of MS Powder coated CRCA 1.6 mm thickness outdoor panel of minimum size 600x600x300mm for indicator and isolation transformer for RTU protection. Primary Side : Input 0-230-380-415-460 AC Secondary side : Input 0-230 AC To protect voltage fluctuation & provide isolation Make : CIMCON / BCH/Rittal/Safetek/Powertek (To be installed at Central Chiller Plant but outside the storage building)
S&F of Digital Energy Meter for the Chiller Plant Motor Energy Data Monitoring. Make : Cimcon / Enercon / Trandata / Motorola / Siemens (To be installed at Central Chiller plant for Monitoring)
S&F of wireless modem suitable for GSM/GPRS based communication system, to be mounted in RTU enclosure including GSM Sim card rental and SMS charges for the period two years - 03 Nos of SIM Card. Make : Cimcon / Siemens / Motorola (To be installed at panel & MCS)
S&F of Temp and Humidity sensor with transmitter for rooms and duct temperature and humidity measurement. Make : Baumer / Radix / Masibus / Wika (To be installed in conditioned space)
S&F of process indicator of 48 x 48 mm with retransmission output for monitoring of temperature and humidity. Make : Multispan / Radix / Masibus (To be installed at panel)
S&F 75 x 50 x 2 mm cable tray installation with material for inside the chiller plant.
S&F of 4 Core x 1.5 Sqmm PVC coated armoured Cu control cable. Make : Finolex / Polycab/ Havells / Powercab / Avocab
Supply of 10 Core x 1.5 Sqmm PVC coated armoured Cu control cable. Make : Finolex / Polycab Havells / Powercab / Avocab
Master Control Station. Supply & Installation of intel core i3 processor or equivalent at minimum 2.00 GHz (2 MB L 2 cache), Intel Server Based Motherboard with minimum 800 MHz bus speed, 2 GB DDR 2 SDRAM @ 667 MHz, 160 GB SATA HDD, DVD Writer, 2 x USB 2.0, 2 x Serial Port, Gigabyte LAN 23" TFT Dispaly Monitor with Resolution of 1440 x 900 Pixel and Support 16.2 M Color with required software. Make : HP / DELL / HCL / ACER (To be installed at MCS & Armoury Room)
Supply & Installation of License version software windows-10, MS Office 2016 and anti- virus Software. Make : Quick Heal, Mc Afee, K7, Microsoft
Supply & Installation of UPS-600 VA, 230V, AC complete with battery 15 Min backup. Make : APC / Microtek
Supply & Installation of Laser printer with scanner A4 B & W. Make : HP / Canon / Samsung. (To be installed at MCS)
Supply & Installation of SCADA Software License version with required tags for Central Monitoring and control through wireless communication for Master Control Station. Make : Cimcon / Safetek / Motorola. (To be installed at MCS & Armoury Room)
Supply & Installation of Front End Processor (FEP) ARM 9 PROCESSOR 32 bit micro controller 512 MB mermory 64 MB data memory with real time clock & 16x2 line LCD display, 2 USB, 2.0 ports IS standard, 5-300 Hz communication protocol suitable to GSM mode communication for Master Control Station. Make : Cimcon/ Safetek / Powertek. (To be installed at MCS & Armoury Room)
Supply & installation PVC insulated armoured cable with PVC outer sheathed control cable 1100 V grade copper conductor of size 3 core 1.5 Sqmm confirming to IS : 7098 (Pt-I) complete all as specified and as directed.
Ditto all as per Srl item No. 14.18 here-in-before but for next 11 calendar months after completion of 1st 11 calendar months.
Ditto all as per Srl item No. 14.18 here-in-before but for next 11 calendar months after completion of 2nd 11 calendar months.
SCHEDULE "A" PART -XV (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' 5 ' signifies this fact only.
INTERNAL ELECTRIFICATION. M&L for sub main wiring with 2 runs of 2.5 Sqmm(Nominal area) FRLS-H PVC insulated unsheathed copper conductor cable 1100Volts grade, drawn through in and including stove enameled ERW steel conduit pipe on surface with flame proof accessories such as elbow, bend etc of suitable size for eight/six light points controlled by one switch/MCB including earth continuity conductor using FRLS-H PVC insulated unsheathed copper conductor cable of size 2.5 Sqmm (Nominal area) green in colour connected to common earth dolly complete all as specified and directed. Note:- One run of conduit and three run of 2.5 sq mm copper conductor shall be measured as one unit.
S&F LED Flame proof flood light fitting 70/80W in cast aluminium alloy LM6 construction with integral reflector certified by CMRS, Dhanbad for group IIA & IIB complete with mounting arrangement on wall/pillars”
S&F LED light fitting flame proof type FLP-WP of 1x20W CMRI certified flame proof light fitting including integral reflector made of aluminium alloy LM6 with heat resistant tubular glass cover held in two aluminium cups, with bipin holders, connector block, etc. and all accessories prewired and including 1 Nos 20 Watt LED tube light of suitable size, connecting up with three core PVC insulated sheathed copper conductor cable of size not less than 0.5 sqmm complete all as specified and directed.
S&F Flame proof sheet metal enclosure for MCB DB single pole and neutral 8 way with 200 Amps rated bus bar, neutral link, dinrail suitable for mounting MCB's 240 volts double door type complete all as specified and directed. Note : MCB's are measured and paid in separate items.
S&F Flame proof sheet metal enclosure for MCB TPN Double door DB 4-way,440V, with 200Amp rated bus bar, neutral link, din rail suitable for mounting MCBs complete all as specified and as directed. (Note: MCBs shall be measured and paid under separate item).
S&F MCB TPN 63Amps (C-Curve), breaking capacity 10KA, 440V with cable connection and copper lugs all as specified and directed.
S&F MCB TPN 32Amps (C-Curve), breaking capacity 10KA, 440V with cable connection and copper lugs all as specified and directed.
S&F MCB SP 6 to 32 Amps (C-Curve), breaking capacity 10 KA, 240 volts with cable connection and copper lugs complete all as specified and directed.
S&F MCB SPN 6 to 32 Amps (C-Curve), breaking capacity 10 KA, 240 volts with cable connection and copper lugs complete all as specified and directed.
S&F LED light fitting, 20W ,230V, natural white, hanging type aluminium extruded dimension 4ft LED Battens-integrated type, with bipin holders, connector block, including suspension of 1.5mtr(02 Nos) etc. complete with all accessories pre-wired and including connecting up with three core pvc insulated sheathed copper conductor cable of size 0.5Sqmm all as specified and as directed.
S&F LED light fitting, 20W, 230V, natural white, Indoor wall mounting type, aluminium extruded dimension 4ft LED Battens-integrated type, with connector block, etc. complete with all accessories pre-wired and including connecting up with three core pvc insulated sheathed copper conductor cable of size 0.5Sqmm all as specified and as directed..
S&F LED security light fitting, 20W, 230V Powder coated pressure die cast aluminium compact high powerwith heat resistant toughned glasswith suitable outer diameter GI bracket,clamp nut bolt etc. complete with all accessories pre-wired and including connecting up with three core pvc insulated sheathed copper conductor cable of size 0.5Sqmm all as specified and as directed.
S&F 1400mm sweep ceiling fan and connecting up of cable from ceiling rose with pvc insulated sheathed three core copper conductor wire of size 23/0.0076h connector to fan complete all as specified.
Supply and Fixing exhaust fan of size 300mm sweep 1400 rpm and connecting up including provision of cable from ceiling rose or connector to fan complete with louvers all as specified and directed.
Supply and Fixing exhaust fan of size 450mm sweep 1400 rpm and connecting up including provision of cable from ceiling rose or connector to fan complete with louvers all as specified and directed.
Material and Labour for sub main wiring with 2 runs of single core 2x4 Sqmm (Nominal Area) FRLSH PVC insulated unsheathed multistranded copper conductor cable LT 1100 Volts grade, drawn through in and including PVC rigid conduit pipes of size 25 mm dia medium grade including earth continuity conductor using FRLSH PVC insulated unsheathed copper conductor cable of size 4 Sqmm (Nominal Area) green in colour connected to common earth dolly complete all as specified and as directed”. (Note :Two runs of cable and one run of earth continuity copper conductor cable with pvc conduit shall be measured as one run length)
M & L Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanised steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No 3 of SSR Part I including necessary excavation and earth work PCC 1:3:6 type C-I with 50mm thick pre-cast RCC (1:2:4) type B-I cover slab (reinforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle of 10mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15cm compacted thickness all around earth electrode, with funnel and 20mm bore galvanised iron watering pipe (light grade), wire mesh, aluminum lugs, complete in all respect, GI earth wire protected by 15mm bore (medium grade) galvanised iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work to a distance not exceeding 50 mtrs and necessary testing on completion complete all as specified and directed.
INTERNAL WATER SUPPLY. S&F 15 mm bore angle stop cock brass CP high pressure with capstan head, long shank screwed down complete all as specified and directed.
ROAD/PATH/CULVERT. Material & Labour 200 mm thick (compacted thickness) GSB-II (Granular sub base) of table 400-1 of MORTH, IRC specification, spreading in two layers n.exc. 100 mm thick each layer over compacted Sub-grade, watering, rolled and consolidated using power roller exc 8 tonne but n. exc 12 tonne as specified to required gradient and camber complete all as specified and as directed.
Material & Labour 150mm thick (compacted thickness) Wet Mix Macadam (WMM) in two layers each layer 75mm thick compacted separately with crushed stone aggregate of specified grading (63mm to 40mm size), rolled and consolidated using power roller exc 8 tonne but n. exc 12 tonne as specified to required gradient and camber complete all as specified and as directed.
SEWAGE DISPOSAL. Construction of Soakage Well for 10 users complete all as shown on drawings and as specified.
S&F On site conventional LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for 10 users all as specified and as directed. Make :- Sintex or equivalent as approved by GE.
EXTERNAL WATER SUPPLY. Construction of brick masonry valve pit of internal dimension 90 cm x 90 cm x 90 cm depth with old size Fly ash bricks in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type C1 (using 20 mm graded broken stone aggregate) as in bedding and copping, MS frame with 50x50x6 mm angle iron, 3 mm thick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft/loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and directed.
Supplying, laying in trenches, under floor, under road, connecting, jointing and testing 80 mm bore (Nominal) Ductile Iron pressure pipe centrifugally cast ISI marked, with socket and spigot ends confirming to IS 8329/2000 standard length, of K7 specification provided with internal cement mortar lining with seal coat of compatible epoxy based material and externally painted with metallic zinc with finishing layer of bituminous paint for potable water complete with and including EPDM rubber ring joints as per IS:5382 (1985) all as specified and directed by Engr-in charge.
M & L for ductile iron fitting as per IS:9523 such as Bends any type any radius, tapers, tee pieces, double branch, collar caps, plug etc upto 200 mm bore flanged end pipe complete all as specified and directed.
Supply, fixing, connection and testing sluice valves 80mm bore, PN-1, cast iron body with forged steel spindle, non rising type, and cast iron wheel head, both ends flanged, IS-14846 marked, complete with neoprene rubber gasket joint and necessary jointing material all as specified and directed.
Cutting to existing CI pipe line of 80 mm dia including taping and supply & fixing Tee for 80mm dia branch connection all as specified and directed.
EXTERNAL ELECTRIC SUPPLY. Supply, installation, commissioning and testing of 200 KVA, Silent Diesel Engine driven generating set outdoor type 415 Volts, 3 phase 4 wire, engine as per IS : 10002 and alternator as per IS : 13364(Pt-2) complete with relay panel for automatic starting on mains failure, control panel having meters, sound proof canopy and concrete foundation complete all as specified and directed comprising of following:- A. a) Fly wheel to suit flexible coupling. b) Flexile coupling with guards. c) Dry type air cleaners with filters. d) Lubricating oil filter, fuel filter, fuel pre filter. e) Anti-vibration pads-quantity and type as recommended by manufacturer. f) Fuel injection system with injector pump, nozzles, governor(electronic) of suitable capacity. g) Electric start equipment. h) Lead acid storage maintenance free battery 2x12V DC of suitable rating with charging alternator, ammeter, as recommended by manufacturers make: As per OEM standard along with copper battery lead and connector. i) Battery rack made out of MS angle iron 40mmX40mmX5mm and 150mm height. j) Standard safety device. k) Daily service fuel tank of suitable capacity for running 12 hrs non-stop on Full Load with mechanical level indicator, detachable strainer, drain cock, fuel outlet, air vent and locking arrangement etc, including fuel pipe connections. l) Exhaust silencer(Residential silencer) with exhaust piping of suitable size brought out side on top of size 76.5 mm dia and complete length of silencer and exhaust piping continuously wrapped with 12 mm dia asbestos rope and suitable anti vibration arrangement around pipe passing through wall.
Serial Item No. 15.29 (Contd....) m) LCD display type control panel as per manufacturer's instructions indicating KWH, KVA, PF, Volts, Amps, Hz, RPM, Hour, Oil pressure, Oil temprature, coolent temprature, fuel level, battery charging ammeter, battery charging lamp and incator lamp (RYB), panel duly prewired and displaying protection and safetys as under:- aa) Protection:- short circuit, overload, over speed, earth fault as standard and reverse power as optional. ab) Safeties:- Auto shut down, visual & audio alarm for low lub oil pressure, high coolant temperature, low fuel level, canopy temperature & radiator water level. (B) Alternator 200 KVA brushless type at 0.8 power factor, self regulated, self excited, screen protected 3 phase with neutral 415 volts 50 HZ, 1500 RPM, as per IS:13364/IS-4722 complete with automatic voltage regulator, having voltage regulation +/-1%, SPDP enclosure including making cable connections, insulation class-H and alternator control panel as supplied by manufacturer. C) Base frame sturdy, MS fabricated, channel iron base frame for mounting the engine & alternator with anti vibration pads. (D) Acoustics enclosure of suitable size to accommodate DG set 200 KVA, modular construction, fabricated out of 3 mm thick, cold annealed CRCA sheet duly epoxy painted doors to be provided with high quality EDPN gasket, duly epoxy painted. The canopy to be equipped with heavy duty fans of reputed manufacturer for air circulation and cooling the canopy. Rock wool of requisite density per Kg/m3 to be used for insulation. Enclosure to be provided with one light point controlled with one switch for internal lighting. Noise level at one meter to be 75 decibels @ one meter in line as per CPCB norms.
Serial Item No. 15.29 (Contd....) (E) Repair tools to be supplied as under:- (i) Ring spanner set of 10- 01 set. (ii) Screw driver 6",9", 12", 14" - 01 No Each. (iii) Adjustable spanner 12" - 01 No. (iv) Double end spanner set of 10 - 01 No. (v) Cutting pliers insulated and nose plier 10" & 12" - 01 No. (vi) Techo meter - 01 No. (vii) Tool kit box - 01 No. (F) Maint spares to be supplied as under :- (i) All type of filters - 02 Each. (ii) V-Belt - 01 Set NOTE:- (i) The engine of DG set suitably conditioned to suit the climatic condition, so as to give desire outputs including and testing up to 10% over load. (ii) Foundation of the DG set (PCC/RCC) will be provided by the contractor and will be made as per the manufacturer instruction. Cost of foundation is deemed to be included in the rate of this item. (iii) The items required for testing of DG set e.g. fuel, tripod, tools, water tank etc and panel as below shall be provided by the contractor and the rate of which is deemed to be included in the rate of item. (iv) Testing of DG set will be carried out as specified. (v) Pre-commissioning test to be carried our for DG Set >10KW.
M & L Earthing complete with copper earth plate electrode 600mm x 600mm x 3.15mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to copper strip 20 x 3 mm earth lead by means of bolts, nuts, check nuts and washers of copper, all as shown in electrical plate No 3 of SSR Part-I including necessary excavation and earth work PCC 1:3:6 type C-1 with 50mm thick pre-cast RCC (1:2:4) type B-1 cover slab (reinforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle of 10mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15cm compacted thickness all around earth electrode, with funnel and 20mm bore galvanised iron watering pipe (light grade), wire mesh, aluminum lugs, complete in all respect, Coper earth strip protected by 25mm bore (medium grade) galvanised iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work to a distance not exceeding 50 mtrs and necessary testing on completion complete all as specified and directed.
M & L Earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to GI strip 32x6 mm earth lead by means of bolts, nuts, check nuts and washers of GI or steel, all as shown in electrical plate No 3 of SSR Part I including necessary excavation and earth work PCC 1:3:6 type C-1 with 50mm thick pre-cast RCC (1:2:4) type B-I cover slab (reinforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle of 10mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15cm compacted thickness all around earth electrode, with funnel and 20mm bore galvanised iron watering pipe (light grade), wire mesh, aluminum lugs, complete in all respect, GI earth strip protected by 40mm bore (medium grade) galvanised iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work to a distance not exceeding 50 mtrs and necessary testing on completion complete all as specified and directed.
M&L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
S&F Octagonal Pole 8mtr long made of hot dipped 3mm thick GI tube having bottom dia 135mm, top dia 70mm, base flange size 225x225x16mm,single arm bracket 1000mm long, fixing nut & bolts of high tensile MS rod, template, TPN connector for loopin & out of main cable, MCB SP,6A rating , cable copper conductor 3-core 1.5Sqmm from junction box to light fitting complete including necessary PCC foundation for mounting of pole as per manufacturer’s specifications. Make :Wipro/ Bajaj/CG
M & L Chemical Earthing complete with copper earth plate electrode 900mm x 600mm x 5mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to copper strip 50x6 mm earth lead by means of bolts, nuts, check nuts and washers of copper, all as shown in electrical plate No 3 of SSR Part I including necessary excavation and earth work PCC 1:3:6 type C-1 with 50mm thick pre-cast RCC (1:2:4) type B-1 cover slab (reinforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle of 10mm dia round bar), including providing hygroscopic chemical material of good conductivity all around earth electrode, with funnel and 20mm bore galvanised iron watering pipe (light grade), wire mesh, aluminum lugs, complete in all respect, Copper earth strip protected by 80mm bore (medium grade) galvanised iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work to a distance not exceeding 50 mtrs and necessary testing on completion complete all as specified and directed.
S&F LED street light luminaire 36W with integral driver, surge protection upto 5KV, Pf not less than 0.95, system efficiency not less than 85%, suitable to work on 120-270V supply duly housed in pressure die cast aluminium housing powder coated, toughened glass, IP-66 Class-I complete all as specified and directed.
S&F cast iron cable route indicator made out of 50x50x6mm angle iron, 60cm long embedded in PCC (1:4:8) type D2 of size 30x30x30cm with letter "HT Cable" or "LT Cable" suitably inscribed on CI circular plate 8mm thick 100mm dia duly painted with brown colour for HT and blue colour for LT complete all as directed.
DANGER BOARD. S & F retro reflecting sheet written in computerised letter 50 Nos as required basis for each board complete all as specified and directed.
FENCING. S&F CONSEC-ZAL Super Razor punched barb tape (SRPBT) Aluminium base helix coil with and including necessary GI fixing clips for securing complete all as specified and directed with following specifications:- (i) Dia of coil (when unstretched) - 1000mm (ii) No of circles-51 turns per coil (iii) Weight of each coil with hessian pack - 14.50 Kg ( +0.7 ) (iv) Coverage per coil - 10 RM (v) Central core wire :- Made from 2.50 mm dia GI- H.T.S.S. wire as per IS-4454 galvanised as per IS-2629. (vi) Razor Punched Strip:- Razor punched tape is CONSEC-ZAL Steel comprising of Aluminium base with Zinc coating @ 150 gm/Sqm conforming to ASTM A-792/A-792M with additional primer treatment of Epoxy/ Polyurethane & Final Paint Top coat of Caulfield green shade(BSL 139) by Hot Dipping process. (Note:- Running length of the fencing shall be measured for payment purpose.)
EOT CRANE. Design, supply and installation of flame proof EOT crane duty class M5, double girder type having span of 9.5 m, long travel 36 m, clear hook height 3.0 m and weight lifting capacity of 5.0 Ton considering following conditions complete all as specified and directed:- (i) Internal dimension of Bldg is 36m X 19m X 5.2m with partition wall at middle. (ii) Clear hook height available from FFL is 3.0m (iii) The operation and micro speed of crane should be as following:- (a) Main Hoist:- 3-4m/min (d) Micro in cross travel - 0.5 m/min (b) Micro in main Hoist - 0.3-0.4m/min. (e) Long travel - 10-15 m/min (c) Cross travel - 5 m/min (f) Micro in long travel- 1m/min (iv) EOT crane fitted should be fire/flame proof and comply with the safety specification given in the STEC pamphlet No 7. (v) EOT crane fitted should be comply with the saftey specification such as limit swiches, alarm, guards, isolating switches, emergency stop button and interlocking, power and control cabling complete etc confirming to IS-807, IS-3177, IS-3938 specifications. (vi) Design, Supply, Installation, Testing and Commissioning of Crane shall be undertaken through Manufacturers/ Specialist Firms. (vii) Design of crane and proof checking of design from any of Government Chartered Engineers within 2 months from the date of acceptance of tender. (viii) Crane fabricator to verify the exact internal diamensions of the building physically before starting fabrication of the Crane. (ix) VVVF Drive to be provided.
Design, supply and installation of flame proof EOT crane duty class M5, double girder type having span of 7 m, long travel 19 m, clear hook height 4.20 m and weight lifting capacity of 5.0 Ton considering following conditions complete all as specified and directed:- (i) Clear hook height available above ground level of approach road should be minimum 4.20 m (ii) The operation and micro speed of crane should be as following:- (a) Main Hoist:- 3-4m/min (d) Micro in cross travel - 0.5 m/min (b) Micro in main Hoist - 0.3-0.4m/min. (e) Long travel - 10-15 m/min (c) Cross travel - 5 m/min (f) Micro in long travel- 1m/min (iii) EOT crane fitted should be fire/flame proof and comply with the safety specification given in the STEC pamphlet No 7. (iv) EOT crane fitted should be comply with the saftey specification such as limit swiches, alarm, guards, isolating switches, emergency stop button and interlocking, power and control cabling complete etc confirming to IS-807, IS-3177, IS-3938 specifications. (v) Design, Supply, Installation, Testing and Commissioning of Crane shall be undertaken through Manufacturers/ Specialist Firms. (vi) Design of crane and proof checking of design from any of Government Chartered Engineers within 2 months from the date of acceptance of tender. (vii) Crane fabricator to verify the exact diamensions of the building physically before starting fabrication of the Crane. (ix) VVVF Drive to be provided.
PRIME COST SUM. The prime cost is to used as directed by the Accepting Officer vide condition 1(v) and 5 of IAFW-2249. (a) Provide a prime cost of Rs. 6,00,000.00 for Provision four sets of Steel Roller Treadway (Each Set consists of two Nos Steel Roller) for 02 Igloo Buildings as approved by GE. (b) The contractor is to quote the amount in the money column i.e. in Col 6 adding his overhead and profit. The amount shall be adjusted proportionately to the sum actually expended against Prime Cost Sum. Notes :- (i) Item(s) covered under Prime Cost Sum shall be ordered as per condition 5 of IAFW-2249. (ii) Contractor will quote rate for this item upto maxomum of Rs. 6,90,000.00 resulting maximum percentage of 15%. If contractor quotes rate more than Rs 6,90,000.00, amount column shall automatically adapt amount of 6,90,000.00 and percentage column shall adapt percentage 15% . In case of acceptance of such quoted tender, rate quoted against this item shall be amended to 6,90,000.00 through alteration and contractor will have no claim on this account. However if contractor quotes rate less than 6,90,000.00, quoted amount and derived percentage shall be reflected as such under amount column & percentage column.
SCHEDULE "A" PART-XVI (SCHEDULE OF CREDIT) Note :- Amount of Rs. 48560.00 indicated in Tender as Schedule of Credit shall be deducted from the total quoted amount of BOQ.
M. P. Sitani and Sons
MAA BHAGWATI ASSOCIATES
SARINS
M/S Sohanlal Agarwala
VARNI BUILDERS
Phoenix Infra
DEEP NIRMAN
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Download all tender documents and submit your bid