Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-Finance GLYPTIC RAIPUR P O BHITA BURDWAN 713102 | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | 713102 | L1 | Accepted-Finance 1st lowest bidder | |
| 2 | L2₹4.9 L+₹53,559 (12.2%)Rejected-Finance BASUDEBPUR BELKHALI HOWRAH PIN 711 322 | HOWRAH | HOWRAH | WEST BENGAL | 711322 | L2 | Rejected-Finance 2nd lowest bidder | |
| 3 | L3₹9.0 L+₹4.6 L (104.5%)Rejected-Finance 334 SCHOOL DANGA BANKURA BANKURA WEST BENGAL 722101 | BANKURA | BANKURA | WEST BENGAL | 722101 | L3 | Rejected-Finance 3rd lowest bidder | |
| 4 | L4₹9.0 L+₹4.6 L (104.8%)Rejected-Finance 334 1 SCHOOLDANGA BANKURA 722101 | BANKURA | WEST BENGAL | 722101 | L4 | Rejected-Finance 4th lowest bidder | |
| 5 | L5₹9.0 L+₹4.6 L (104.8%)Rejected-Finance VILL P O JAMBEDIA DIST BANKURA PIN 722139 | JAMBEDIA | BANKURA | WEST BENGAL | 722139 | L5 | Rejected-Finance 5th lowest bidder |
Tender Value
Refer Docs
EMD Value
₹12,340
Closing Date
6 Jan 2024, 4:00 pmClosed
SUPERINTENDING ENGINEER (P.W.D)
OFFICE OF THE SUPERINTENDING ENGINEER (P.W.D) South-Western Electrical Circle PWD Compound, Midnapore, Paschim Medinipur
Supply, Installation, Testing and Commissioning of Fire Detection and Alarm system at Nursing Training School, MMC and H, Paschim Medinipur.
2023_WBPWD_603832_1
WBPWD/SE/SWEC/NIQ54/2023-24
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
PASCHIM MEDINIPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹12,340
OFFICE OF THE SUPERINTENDING ENGINEER,SWEC
23 Feb 2024
18 Nov 2023
8 Jan 2024
18 Nov 2023
6 Jan 2024
22 Nov 2023
21 Nov 2023
Amount
SITC of Microprocessor based Intelligent, addressable single Loop ( Expandable upio 2 loops ) fire alarm control panel ( VDS / UL / FM / ULC/LPCB approved ) fully networkable with each loop capable of taking 120 devices, 1/4 VGA display character alpha-numeric liquid crystal display.The panel shall be soft addressable type.The panel shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered.The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. IS / NBC. Shiuld have the provision for incorporating with BMS
The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 30 minutes during Emargency condition, with integral battery charger complete as required.
The FACP shall be capable of being networked ( future expansion ) with other similar FACP located at different part of the premises through single RS 485 bus.The FACP shall have provision for interfacing with the public address system and BMS ( RS 485 ). The panel should have modbus output & ready to communicate with remote computer. The system must be preloaded with licenced software. (Approved Make:- Honeywell-Esser /Siemens-Cerberus Pro / Bosch/ Johnson Controls/ Honeywell- Notifer / Edward /Secutron/ Securiton/ Apollo / Honeywell- Morley / System Sensor )
SITC of Analog Addressable Intelligent multisensor detector ( VDS / UL / FM / ULC/LPCB approved ) with inbuilt optical smoke sensors as well as additional heat detector sensor with decentralise intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard. (Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended IS / NBC ) without any additional cost). (Approved Make:- Esser/Cerberus Pro/ Bosch/ Johnson Controls/ Notifer / Edward /Secutron/ Securiton/ Apollo / Morley / System Sensor)
SITC of Addressable Manual Call Point ( VDS / UL / FM / ULC/LPCB approved ) soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. (Approved Make:- Honeywell-Esser /Siemens-Cerberus Pro / Bosch/ Johnson Controls/ Honeywell- Notifer / Edward /Secutron/ Securiton/ Apollo / Honeywell- Morley / System Sensor )
SITC of Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base and ( VDS / UL / FM / ULC/LPCB approved) approved. (Approved Make: Honeywell-Esser /Siemens-Cerberus Pro / Bosch/ Johnson Controls/ Honeywell- Notifer / Edward /Secutron/ Securiton/ Apollo / Honeywell- Morley / System Sensor )
SITC of LED type Response Indicator ( VDS / UL / FM / ULC/LPCB approved) having 2 Nos. red coloured LED lamps including connections etc. (Approved Make:- Honeywell-Esser /Siemens-Cerberus Pro / Bosch/ Johnson Controls/ Honeywell- Notifer / Edward /Secutron/ Securiton/ Apollo / Honeywell- Morley / System Sensor )
SITC of Power supply 230 V AC to 24V DC with all other accessories. (Make: Reputed)
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make:- Gloster/ Finolex/RR Kable/Polycab/KEI ) with 20 mm NB PVC rigid conduit pipe (Make: Precision/AKG/ATUL /VIP/ Universal /BEC/Polycab) on the surface of the wall.
TERMS & CONDITIONS
a.The Fire Alarm system shall comply with latest requirements of -- 1. National Fire Protection Association (NFPA) Standards. 2. IS 2189 3. NFPA 70 National Electric Code 4. NFPA 72 National Fire Alarm Code 5. local Statutory Regulations 6. Manufacturer Recommendation.
b. TESTS:1.The system shall be tested and commissioned by a qualified competent,trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2. Before energizing the cables and wires, check for correct connections and test for short circuits, ground faults, continuity, and insulation and other tests as per above standards must be done.
c. Auto CAD Drawing of whole FDA system & submission of 5 set hard copy of drawing and soft copy (in Auto-CAD format) is to be submitted.
d. The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
e. Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill.
f. If any refurbished material is supplied and installed, penal action will be taken as per existing rules
Computer Gallery
Swarnendu Sarkar
TAPAN KUMAR SARKAR
UJJWAL MUKHERJEE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .