telecommunication cable
telecommunication cable Telecommunication Cable ( 200 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Govering Specification for telephone pair cable TEC Specification G/WIR06/02 * Conductor diameter Nominal (Range) (mm) 0.5 0.5 Number of pair (Number) 20 20 Lenght of cable in a bundle (Mtrs) 100 100 CONSTRUCTIONAL Telephone Pair cable used for Telecom data transmission
Intercome
EPBAX
FAX
Closed circuit security System. Yes * Conductor Materail Copper * Insulation PVC * Shelding Yes * 1/7 Minimum Diameter over insulation (mm) .8 * Overall diameter of cable (mm) 15.5 * CERTIFICATIONS Product Conforming to TEC Specification Yes * Distinct Color Coding system As per TEC Specification * Availability of complete and satisfactory type test Report from Central govt/NABL ILAC accredited laboratory as per Govering Specification Yes * Test certificate number KCI/06/16 * Test report date 18.06.2017 * Name of lab where test conducted INHOUSE LAB * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Kishor Goswami 781015
O/o Regional Executive Director(NER); Airports Authority of India
Regional Head Quarter
LGBI Airport
Borjhar 200 15 Telecommunication Cable ( 400 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Govering Specification for telephone pair cable TEC Specification G/WIR06/02 * Conductor diameter Nominal (Range) (mm) 0.5 0.5 Number of pair (Number) 10 10 Lenght of cable in a bundle (Mtrs) 100 100 2/7 CONSTRUCTIONAL Telephone Pair cable used for Telecom data transmission
Closed circuit security System. Yes * Conductor Materail Copper * Insulation PVC * Shelding Yes * Minimum Diameter over insulation (mm) 0.5 * Overall diameter of cable (mm) 20 * CERTIFICATIONS Product Conforming to TEC Specification Yes * Distinct Color Coding system As per TEC Specification * Availability of complete and satisfactory type test Report from Central govt/NABL ILAC accredited laboratory as per Govering Specification Yes * Test certificate number GR/CUG-10 * Test report date 03-AUGUST-2003 * Name of lab where test conducted T.E.C. Banglore * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Kishor Goswami 781015
Borjhar 400 15 Telecommunication Cable ( 600 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Govering Specification TEC Specification * 3/7 for telephone pair cable G/WIR06/02 Conductor diameter Nominal (Range) (mm) 0.5 0.5 Number of pair (Number) 4 4 Lenght of cable in a bundle (Mtrs) 100 100 CONSTRUCTIONAL Telephone Pair cable used for Telecom data transmission
Closed circuit security System. Yes * Conductor Materail Copper * Insulation PVC * Shelding Yes * Minimum Diameter over insulation (mm) 0.8 * Overall diameter of cable (mm) 15 * CERTIFICATIONS Product Conforming to TEC Specification Yes * Distinct Color Coding system As per TEC Specification * Availability of complete and satisfactory type test Report from Central govt/NABL ILAC accredited laboratory as per Govering Specification Yes * Test certificate number NC/PIJF-005A * Test report date 20.04.2018 * Name of lab where test conducted Digisol india * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Kishor Goswami 781015
Borjhar 600 15 4/7 Telecommunication Cable ( 700 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Govering Specification for telephone pair cable TEC Specification G/WIR06/02 * Conductor diameter Nominal (Range) (mm) 0.5 0.4
0.5 Number of pair (Number) 2 2 Lenght of cable in a bundle (Mtrs) 100 100
250
500 CONSTRUCTIONAL Telephone Pair cable used for Telecom data transmission
Closed circuit security System. Yes * Conductor Materail Copper * Insulation PVC * Shelding Yes * Minimum Diameter over insulation (mm) 0.9 * Overall diameter of cable (mm) 4.40 * CERTIFICATIONS Product Conforming to TEC Specification Yes * Distinct Color Coding system As per TEC Specification * Availability of complete and satisfactory type test Report from Central govt/NABL ILAC accredited laboratory as per Govering Specification Yes * Test certificate number TEC/540221 * Test report date 12/02/2018 * Name of lab where test conducted T.E.C. Delhi * * Bold specifications are the golden parameters. Consignees and Quantity 5/7 S.No. Consignee Address Quantity Delivery Days 1 Kishor Goswami 781015
Borjhar 700 15 Telecommunication Cable ( 500 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Govering Specification for telephone pair cable TEC Specification G/WIR06/02 * Conductor diameter Nominal (Range) (mm) 0.5 0.5 Number of pair (Number) 1 1 Lenght of cable in a bundle (Mtrs) 100 100 CONSTRUCTIONAL Telephone Pair cable used for Telecom data transmission
Closed circuit security System. Yes * Conductor Materail Copper * Insulation PVC * Shelding Yes * Minimum Diameter over insulation (mm) 0.5 * Overall diameter of cable (mm) 1 * CERTIFICATIONS Product Conforming to TEC Specification Yes * Distinct Color Coding system As per TEC Specification * Availability of complete and satisfactory type test Report from Central govt/NABL ILAC accredited laboratory as per Govering Specification Yes * Test certificate number 8512352487 * 6/7 Test report date 2014 * Name of lab where test conducted Finolex Survey No 26/27
Mumbai Pune Road
Pimpri
Pune * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Kishor Goswami 781015
Borjhar 500 15