Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.7 LAccepted-AOC FIRST FLOOR 06 NEAR JAGGI MEDICAL STORE ROPAR | L1 | Accepted-AOC L1 | |
| 2 | L2₹67.2 L+₹8.5 L (14.5%)Rejected-AOC | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | AJIT SINGH CONTRACTOR L1 | PANDHU CONTRACTOR L2 |
|---|---|---|---|---|---|
| 1.00 | Dismantling of Old Bridge (RCC Main Slab) (CSR item no. 8.6 e) | 183.23 | cum | 459.2 ₹459.2 Lowest | 487.9 ₹487.9 |
| 2.00 | Dismantling brick work tile, masonry or tile lining (CSR item no. 8.5-b) | 51.26 | cum | 13,283.8 ₹13,283.8 | 9,376.8 ₹9,376.8 Lowest |
| 3.00 | Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with excavated surplus soil. (CSR item no. 21.1-B) | 1,523.72 | cum | 24,850.28 ₹24,850.28 | 17,750.2 ₹17,750.2 Lowest |
| 4.00 | Back filling behind abutment, wing wall and return wall complete as per drawing and Technical Specification (21.36 B) | 923.25 | cum | 5,550 ₹5,550 Lowest | 6,012.5 ₹6,012.5 |
| 5.00 | Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days M-10 (CSR item No. 21.4) | 122.33 | cum | 1,292.4 ₹1,292.4 Lowest | 1,400.1 ₹1,400.1 |
| 6.00 | Rehandling of E/work (CSR chapter 6 note no.2 ) | 1,523.72 | cum | 3,107.1 ₹3,107.1 Lowest | 6,214.2 ₹6,214.2 |
| 7.00 | Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days M-10 (CSR item No. 21.4) | 122.33 | cum | 1,75,125 ₹1,75,125 Lowest | 1,84,465 ₹1,84,465 |
| 8.00 | Plain/Reinforced cement concrete in open foundatio complete as per drawing and Technical Specifications RCC grade M 25 using Concrete Mixer including centering and shuttering. (CSR
Item No. 21.7-E/i) | 151.68 | cum | 11,503.9 ₹11,503.9 Lowest | 13,534 ₹13,534 |
| 9.00 | Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC grade M 25 height upto 5 mtr using Concrete Mixer including centering and shuttering. (CSR Item No. 21.32-F/a/i) | 449.12 | cum | 5,711.64 ₹5,711.64 Lowest | 6,490.5 ₹6,490.5 |
| 10.00 | Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC grade M 30 height upto 5 mtr using Concrete Mixer including centering and shuttering. (CSR Item No. 21.32-G/a/i) | 39.26 | cum | 25,025 ₹25,025 Lowest | 26,390 ₹26,390 |
Tender Value
₹1.4 Cr
EMD Value
₹2.9 L
Closing Date
12 Jan 2026, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Executive Engineer
Sub Estimate for Head Regulator for Mehrajpur Minor, Fatuhi Khera Minor, Old Tarmala Minor offtaking at RD 10867, 25077, 37227, and 125977 Respectively of Lambi Distributory
2025_WR_156801_1
10336
Open Tender
Civil Works
Item Wise
Sri Muktsar Sahib
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Yes
₹2.9 L
Yes
23 Mar 2026
29 Dec 2025
12 Jan 2026
29 Dec 2025
12 Jan 2026
29 Dec 2025
Dismantling of Old Bridge (RCC Main Slab) (CSR item no. 8.6 e)
Dismantling brick work tile, masonry or tile lining (CSR item no. 8.5-b)
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with excavated surplus soil. (CSR item no. 21.1-B)
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical Specification (21.36 B)
Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days M-10 (CSR item No. 21.4)
Rehandling of E/work (CSR chapter 6 note no.2 )
Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days M-10 (CSR item No. 21.4)
Plain/Reinforced cement concrete in open foundatio complete as per drawing and Technical Specifications RCC grade M 25 using Concrete Mixer including centering and shuttering. (CSR Item No. 21.7-E/i)
Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC grade M 25 height upto 5 mtr using Concrete Mixer including centering and shuttering. (CSR Item No. 21.32-F/a/i)
Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC grade M 30 height upto 5 mtr using Concrete Mixer including centering and shuttering. (CSR Item No. 21.32-G/a/i)
Plain/Reinforced cement concrete in open foundation complete as per drawing and Technical Specifications RCC grade M 20 height upto 5 mtr using Concrete Mixer including centering and shuttering. (CSR Item No. 21.7)
Furnishing and placing reinforcement / prestressed cement concrete RCC M-40 in super-structure complete as per drawing Technical specifications height upto 5 mtr using Concrete Mixer for railing including centering and shuttering. (CSR Item No. 22.1-E/a/i)
Supplying, fitting and placing HYSD bar reinforcement in sub structure complete as per drawing and Technical Specifications. (CSR item no. 21.33)
Providing and fixing 160 mm dia PVC pipe for service duct single socketed (working pressure 4 kgf / cm²) (CSR item no. 13.74-ii)
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. (CSR item no:16.17 )
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface (CSR item No. 16.31 )
Providing and filling joint sealing compound with coarse sand and 6 percent bitumen by weight complete as per drawings and technical clause 2605 of MORT&H specifications (CSR Item No. 24.61 (b)]
Cautionary sign board 900x900x900mm triangular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 09 and as per IRC 67 2012 as per clause 6.9 of IRC 67-2012 for retro reflective sheeting Using high intensity Microprismatic grade retro reflective Sheeting Type XI as per ASTM D 4956 09 and as per IRC 67 2012
Informatory sign board 800 x 600 mm square as per IRC 67 - 2001 with retro reflective high intensity microprismatic gradecomplete as per technical clause 801 MORT&H specifications.
Mandatory sign board 900 mm circular as per IRC 67 - 2001 with retro reflective high intensity microprismatic grade complete as per technical clause 801 MORT&H specifications Using high intensity Microprismatic grade retro reflective Sheeting Type XI as per ASTM D 4956 09 and as per IRC 67 2012.
Advance Direction sign board 1200x1200mm rectangular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per clause 6.9 of IRC 67-2012 for retro reflective sheeting &a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67- 2012 .Using high intensity Microprismatic grade retro reflective Sheeting Type XI as per ASTM D 4956 09 and as per IRC 67 2012
Hazard Marker sign board 300x900mm rectangular as per IRC 67- 2012 with high intensity Microprismatic grade as per clause 801 of MORT&H specifications Using high intensity Microprismatic grade retro reflective Sheeting Type XI as per ASTM D 4956 09 and as per IRC 67 2012
Dressing bed and preparation of sub grade for lining.
Dressing side slopes and preparation of sub grade for lining.
Cement concrete lining 75mm. thick or less laid manually for irrigation channels, using cement concrete M- 15 with cement content 325 kg/cum mixed in an automatic computerized Batching & Mixing Plant and transported to the site in transit mixers with an average lead of 1 Km(FOR TRAPEZOIDAL SECTION AND CUP SECTION OF ALL RADII)
Providing & fixing in position of flat/wedge seal including preparation of surface complete in all respects and to entire satisfaction of Engineer in charge.(75 mm dia x 10 mm th.)
Providing of hollow bulb seal & fixing in position including preparation of surface complete in all respects and to entire satisfaction of Engineer in charge. (57/22 x 8mm)
Supply, Providing and fixing of MS Bolts & Nuts (for seals of all types) with washer of all sizes and length required as per sample / drawing / direction of Engineer-In charge complete in all respects.
Supply, Providing and fixing of CSK Screw (for seals of all types) with washer of all sizes and length required as per sample / drawing / direction of Engineer-In charge complete in all respects.
MS Housing Cover with worm and worm wheel assembly, shaft, handle, gun metal bush with triple start threading inside complete in all respects 0.75 Ton capacity
Supply of MS Spindle with Double Start Threading for Hoist Machanism including machinning complete in all respects and to entire satisfaction of Engineer in charge 43mm dia
Supply and Fixing of spindle cover
Fixing and Holding the gate with the help of 35 tonne capacity crane.
Commisioning & testing of Gates at site complete in all respects and to entire satisfaction of Engineer In charge.
Providing & Fixing Clamp Plate, complete in all respects
Painting of Gate Leaf with primer coat and two coats with Anti corrosive Bitumastic paint to give an even shade with special quality paint.
Painting two coats with ready mix synthetic enamel paints over one coat metal primer
Providing and Fixing Plates
Providing and Fixing ISMC 100 x 50 mm
Providing and Fixing of MS Square Bar 16 x 16 mm
Providing and Fixing Stainless Steel Flat
Providing and Fixing ISMB 200 x 100 mm
Providing and Fixing of Anchor
Threading of Pins complete in all respects and to entire satisfaction of Engineer-in-Charge (Upto 75mm)
Providing and Fixing SHS
Fillet welding with high strength steel rods complete in all respects (6mm)
Drilling/Boring hole including rimming complete in all respects and to entire satisfaction of engineer in charge
Supply of multi purpose Synthetic hetiv grease
Supply of Diesel
Supply of Mobil Oil
Machining of Anchor Bolt to give shape complete in all respects and to entire satisfaction of Engineer-in- Charge
Providing & Fixing of Pin in position complete in all respects and to entire satisfaction of Engineer-in - charge. (upto 75mm/above 75mm)
Any other item
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.82 MB
Tendernotice_2.pdf
PDF • 1.24 MB
Tendernotice_3.pdf
PDF • 1.90 MB
BOQ_317907.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .