Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹73.6 LAccepted-AOC B 2 46 SECTOR 18 ROHINI DELHI 110089 | NORTH WEST | DELHI | 110089 | 1 | Accepted-AOC Awarded | |
| 2 | 2₹75.3 L+₹1.7 L (2.37%)Rejected-Finance | 2 | Rejected-Finance Rejected | |
| 3 | 3₹81.0 L+₹7.4 L (10.1%)Rejected-Finance | 3 | Rejected-Finance Rejected | |
| 4 | 4₹82.8 L+₹9.2 L (12.5%)Rejected-Finance HOUSE NO 2 4 136 LINGREDDY MANSION BLOCK NO IV OPP HANUMAN TEMPLE TADBUND SECUNDERABAD 500009 | SECUNDERABAD | HYDERABAD | TELANGANA | 500009 | 4 | Rejected-Finance Rejected | |
| 5 | 5₹84.1 L+₹10.5 L (14.3%)Rejected-Finance 20 21 ETA HOUSE RAZAK GARDEN MAIN ROAD RAZAK GARDEN MAIN ROAD CHENNAI TAMIL NADU 600106 | CHENNAI | TAMIL NADU | 600106 | 5 | Rejected-Finance Rejected |
Tender Value
₹90.1 L
EMD Value
₹1.8 L
Closing Date
26 Aug 2021, 3:00 pmClosed
CCE(RND) SOUTH
Akbar Road, secunderabd
OPERATION AND MAINTENANCE OF AIR CONDITIONING SYSTEM, CLEAN ROOMS, AMC OF VRF WITH OEM, SPLIT ACS AND WATER COOLERS FOR VARIOUS FACILITIES INSIDE RCI, HYDERABAD
2021_DRDO_642178_1
83611/ONM/AC/INSIDE/CON
Limited
Support/Maintenance Service
Item Rate
330 days
Inside RCI Hyderabad
as per NIT
2 documents required · 2 mandatory
₹1,000
Yes
CCE(RND) SECUNDERABAD
₹1.8 L
Yes
1 Oct 2021
6 Aug 2021
27 Aug 2021
6 Aug 2021
26 Aug 2021
12 Aug 2021
7 Aug 2021 - 11 Aug 2021
Amount
DESCRIPTION
Operation and maintenance for the following installations as per detailed scope of work indicated at Annexures-II-V, on all days in General / Two / Three shifts mentioned in Annexure -VI of enquiry. Scope of Work (a) Operation and Maintenance for Air conditioning systems
Detailed Building Wise Manpower distribution is enclosed as per Appendix- VI of Enquiry. High Skilled (Supervisor) - 01 Person * Rate should be quoted for 01 Person for 01 Month
Detailed Building Wise Manpower distribution is enclosed as per Appendix- VI of Enquiry. Skilled - 08 Persons * Rate should be quoted for 08 Persons for 01 month
Detailed Building Wise Manpower distribution is enclosed as per Appendix- VI of Enquiry. Non Skilled - 07 persons * Rate should be quoted for 07 Persons for 01 Month
Same as mentioned in above but in Additional hours High Skilled (Supervisor)
Same as mentioned in above but in Additional hours Skilled
Same as mentioned in above but in Additional hours Non Skilled
Monthly Comprehensive Annual Maintenance contract of VRF/VRV system by deploying respective original equipment manufacturers. (Scope Of work is given in Annexure - II (Inventries of installation - Annexure - III), AMC for 11 Months
Carrier Make - 220 HP
TOSHIBA Make - 162 HP
DAIKIN Make - 248 HP
Blue Star Make - 64 HP
LG Make - 118 HP
Monthly Comprehensive Annual Maintenance contract for Split & cassette A/C of Total - 114 TR (Scope Of work is given in Annexure - II , Inventries of installation Annexure -III)
c) 1.5 TR Cassette
c) 2.0 TR Cassette
d) 3.0 TR Cassette
Monthly Comprehensive Annual Maintenance Contract of water coolers for 22 Nos, consumables will be paid on recommendations of Engineer -In Charge, mentioned in sl. No 24 to 43
Supply Installation, Testing & Commissioning of Following Spares, Consumable, Replaceable as per the instruction of Engineer incharge.
WARTER PURIFIERS SPARES & CONSUMABLES
a) 20' SEDMENT FILTERS
b) 20' CARBON FILTERS
c) 20' PRE FILTERS
d) 10' SEDMENT FILTERS
e) 10' CARBON FILTERS
f) 10' PRE FILTERS
g) 10' SPUN FILTERS
h) RO MEMRANES
i) AC-DC ADAPTOR 24V
j) AC-DC ADAPTOR 48V
k) WATER COOLER RELAYS SET
l) WATER COOLER CAPACITORS
n) BOOSTER PUMPS24V
o) BOOSTER PUMPSV48V
R-22 Refrigrant
R-410 Refrigrant
R-407 A Refrigrant
DX Units/VRF Units Spares/Materials
5 HP VRF COMPRESSOR
8HP VRF COMPRESSOR
10 HP VRF COMPRESSOR
4.5 TR DUCTABLE VRF INDOOR PCB BOARD
4.5TR DUCTABLE VRF FAN MOTOR PCB BOARD
4.5TR DUCTABLE VRF INDOOR DC FAN MOTOR
36HP, 30HP VRF LP SWITCH
30HP,36HP VRF OUTDOOR MAIN PCB BOARD
36 VRF HP SWITCH
30 HP DLT SENSORS
CASSETE AC ROOM SENSORS(1.5& 2TR)SUITABLE
GAS SENSORS(1.5&2TR&3TR)
COIL SENSORS(1.5&2TR&3TR)
VRF DRIVE BOARD (30HP)
VRF SINGLE POLE CONTACTORS(30HP)
VRF ELECTRONIC EXPANSION VALVES(36HP&30HP)
30HP & 36HP VRF OUTDOOR UNIT FAN BLADE
DUCTABLE & CASSETTE A/C DRAIN PUMP
DUCTABLE& CASSETTE A/C FOLAT SWITCH
1.6 TR (INDOOR CASSETTE& DUCTABLE) PCB
2 TR (INDOOR CASSETTE& DUCTABLE) PCB
3 TR (INDOOR CASSETTE& DUCTABLE) PCB
63 AMPS MCB & 4 POLE CONTACTOR
32 AMPS MCB ‘S & 4 POLE CONTACTORS
5.5 TR COMPRESSOR
8.5 TR COMPRESSOR
36HP, 30HP, HP& LP SWITCHES
Supply, Installation,Testing commissioning of following materials for 3TR Cassette Type AC Units
a) Fan Motor
24 V Transformer for Split AC
48 V Transformer for Split AC
SSC PROJECTS PRIVATE LIMITED
Supreme Weather Makers Pvt Ltd
omsai thermax engineers
ETA Engineering Pvt Ltd
CHARAN ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .